“Study at your own pace with randomized flashcards and instant feedback — click the green ✓ to remove a card you’ve mastered, the red ✗ to keep it for more review, and tap any card to reveal the answer with its code section.”
Welcome this is Flashcards
Where seating provides lines of sight over heads, spectators in a wheelchair space must be afforded lines of sight over the heads of seated individuals in which row?
802.9.1.1
Knee and toe clearance complying with Section 306 shall be provided beneath which accessible elements?
902.2
In existing buildings, T-shaped turning spaces are permitted to include knee and toe clearance only at which locations?
304.3.2.2.1
Raised characters shall be duplicated in what type of braille?
703.3.1, 703.4.1
Where a visitor communication system is provided at a site, building, or floor entrance (other than the unit door), what specific capability must the public or common-use system interface support in addition to voice communication with the unit interface?
1106.6.1
What is the maximum height above the floor permitted for the front of a sink in a Type A unit kitchen, measured to the higher of the rim or counter surface?
1103.12.4.2
In new buildings, what is the minimum required length of clearance adjacent to the open face of a transfer-type shower compartment?
608.2.1.2.1
The top of a standard bench seat shall be located within what height range above the floor?
903.6
When amusement rides are at rest in the load and unload position, the vertical difference between the ride floor and load/unload area floor shall be within plus or minus:
1002.4.3
In a Type A unit with a side-hinged door oven, the adjacent countertop must be positioned on which side of the door?
1103.12.5.5.2
In Group R-2, R-3, and R-4 occupancies where recreational facilities serve a single building containing Type A or Type B units, what minimum percentage of each type of recreational facility shall be accessible?
1111.2.2
Where an escalator or stairway is added where none existed previously and major structural modifications are necessary for installation, what accessible element is required between the levels served?
IEBC 306.7.10
If wall space does not permit a 36-inch rear grab bar due to a recessed fixture, what minimum length is permitted for the centered rear grab bar?
604.5.2
Automatic teller machines (ATMs) required to be accessible must provide what in front of the machine?
707.2
All dimensions are subject to conventional industry tolerances EXCEPT where the requirement is defined as:
105.3
If vanity countertop space is provided in dwelling or sleeping units not required to be Accessible units within the same facility, what specific requirement applies to the vanity countertop space in the Accessible units?
1102.11.2.1
In Type C (Visitable) Units, where are operable parts of lighting controls and receptacle outlets required to be located?
1105.8
In Type C (Visitable) Units, where a food preparation area is provided on the entrance level, it must include a sink, a cooking appliance, and what other fixture?
1105.7
Openings providing entry to wheelchair spaces on amusement rides shall provide a clear width of what minimum dimension?
1002.4.5
What is the maximum height permitted for the spout outlet of a drinking fountain primarily for children’s use?
602.2.3
Operable parts are required to be operable with one hand and shall not require tight grasping, pinching, or what other action?
309.4
An assembly area with a total seating capacity of 501 to 1000 seats requires a minimum of how many wheelchair space locations?
802.10, Table 802.10
If a building fire alarm system is provided, where must the system wiring be extended within a unit required to have communication features?
1106.3
What is the minimum clearance required between the handrail gripping surface and adjacent surfaces?
505.5
What instructions must be provided in braille on an ATM?
707.1
In new construction, when a circular turning space includes an overlap of knee and toe clearance, what is the maximum permitted depth of this overlap?
304.3.1.1.1
A companion seat is required for each wheelchair space where the interior width of the amusement ride is greater than:
1002.4.7
Where a side-hinged door oven is provided, the adjacent accessible work surface must be positioned on which side of the oven door?
804.5.5.2
In courtrooms, where each area that is raised or depressed is provided, what is the required feature?
807.2
Openings in floor surfaces are limited in size such that they do not permit the passage of a sphere greater than what diameter?
302.3
In existing buildings and facilities, what is the minimum depth required for a wheelchair space entered from the front or rear?
802.4.2
At least what percentage, but not less than one, of the cubicles in visiting areas of judicial facilities shall be accessible on both the visitor and detainee sides?
1110.15.1
Which rooms are explicitly NOT considered employee work areas?
107.5
Public telephones required to have volume control must provide a receiver volume control that provides a gain adjustable up to what minimum gain?
704.3
Two-way communication systems required by Section 1009.8.1 must include which combination of signals?
1009.8.1
Where provided in accessible dressing, fitting, or locker rooms, a shelf shall be located within what height range above the floor?
803.5
In a Type C (Visitable) Unit, a toilet room or bathroom is not required on an entrance level if the habitable space provided on that level is less than what area?
1105.4 Exception
What minimum illuminance level is required at the center of the sign language interpreter station floor, measured at a height of 48 inches above the floor, while signing is underway?
802.11.4
Between 9 inches and 27 inches above the floor, the knee clearance depth is permitted to be reduced at what rate?
306.3.4
In an area of refuge, access to any of the required wheelchair spaces shall not be obstructed by more than how many adjoining wheelchair spaces?
1009.6.3
In Type C (Visitable) Units, which fixture is mandatory in the food preparation area (if provided)?
1105.7
In Type A units, where the lavatory overlaps the water closet clearance, reinforcement shall be provided at the rear wall for a grab bar of what minimum length?
1103.11.1 Exception
For classrooms with volumes up to and including 10,000 cubic feet (285 m3), the reverberation time (T60) for the specified octave frequency bands shall not exceed what time?
808.2.1
Ramp runs with a rise greater than what dimension must have handrails complying with Section 505?
405.8
Where an altered entrance is not required to be accessible because the facility already has an accessible entrance, what must be provided?
IEBC 306.7.5
Where doors lead to an area of refuge or exterior area for assisted rescue and reentry to the floor is possible, door maneuvering clearances shall be provided on which side(s) of the door?
1009.2.2
Where mirrors are located above lavatories complying with Section 606, the bottom edge of the reflecting surface must be mounted at what maximum height above the floor?
603.3
In Group I-1, Condition 2 occupancies, what is the minimum percentage of dwelling units and sleeping units that shall be Accessible units?
1108.5.1.2
In private residence elevators within Type B units, what are the minimum required clear floor length and clear floor width inside the elevator car?
1104.7 Exception
In a sprinklered building, the elevator required by Section 1009.2.1 is NOT required as part of the accessible means of egress if the floor or occupiable roof is provided with a ramp conforming to the provisions of which section?
1009.2.1, Exception 2
In Accessible units, what specific type of bed frame must at least one bed be provided with?
1102.15.2
In a standard adult wheelchair accessible toilet compartment, toe clearance is required on the front partition and at least one side partition, extending 8 inches beyond the face of the partition and 12 inches minimum above the floor, unless the compartment exceeds what depth for a floor-mounted water closet?
604.9.5.1
In units with accessible communication features, if visible notification appliances are provided for a building fire alarm system, when must they be activated?
1106.4.2
In play areas less than 1000 square feet, the clear width of accessible routes is permitted to be reduced to 44 inches (1120 mm) minimum, provided a turning space is present where the reduced route exceeds what maximum length?
1008.4.1.1.1
A noncircular handrail cross section shall have a maximum perimeter dimension of:
505.7.2
Which of the following spaces is defined as Habitable?
107.5
An area of refuge must be separated from the remainder of the story by a smoke barrier complying with Section 709 or which other means of egress component?
1009.6.4
In Accessible units, where are operable windows not required to comply with the general requirements of Section 506.1?
1102.13 Exceptions
For water closets designed for assisted toileting, the clearance around the water closet shall be not less than what minimum width, measured perpendicularly from the side of the clearance not less than 24 inches from the centerline?
1110.2.2.2.1
What is the minimum depth required for a wheelchair accessible toilet compartment with a wall-hung water closet?
604.9.2.1
What is the required frequency modulation for basic speech messages provided by Remote Infrared Audible Sign (RIAS) Transmitters?
703.8.3.1
In Type A units, if a lavatory measuring 24 inches (610 mm) maximum in depth overlaps the water closet clearance, what is the minimum distance required from the centerline of the water closet to the side edge of the lavatory?
1103.11.2.4.4 Exception
Where it is technically infeasible to alter existing bathing rooms to be accessible, what alternative accessible facility is permitted on the same floor and in the same area?
IEBC 306.7.13
Sites, facilities, and elements required to be accessible by the adopted scoping provisions shall comply with the applicable provisions of which chapters?
102.2
Where reinforcement for swing-up grab bars is provided at a Type B unit water closet, the reinforcement must accommodate a grab bar that is centered what distance from the centerline of the water closet?
1104.11.1.1
Where security glazing is used at counters, a method to facilitate what must be provided?
904.6
In addition to direction for use of the communication system, instructions posted in an area of refuge must include information on the planned availability of assistance in the use of stairs or supervised operation of elevators and how to do what?
1009.11
Low resolution VMS signs installed greater than 120 inches above the floor require a minimum character height of 4 inches, which must be increased by 1/5 inch per foot of viewing distance above what minimum distance?
703.7.4, Table 703.7.4
What case must be used for raised characters?
703.3.3
What type of clear floor space approach is required at a standard adult drinking fountain designed for persons using wheelchairs?
602.2.1
For closed-circuit communication systems in units required to have communication features, what specific element must the unit system interface include?
1106.7
The number of accessible elements following an alteration or addition need not exceed the quantity required for:
IEBC 306.2.1
When are separate-sex accessible dressing, fitting, or locker rooms required where technical infeasibility is cited?
IEBC 306.7.16
For water closets designed for assisted toileting, the centerline of the water closet shall be not less than 24 inches (610 mm) and not greater than what distance from one side of the required clearance?
1110.2.2.1
To ensure a nonglare finish, the glare from visual characters and their background shall not exceed how many gloss units (gu)?
703.2.10.1
Doors, gates, or adjacent sidelites containing glazing panels that permit viewing must have the bottom of at least one panel on the door, gate, or sidelite no more than what height above the floor?
404.2.10
An accessible route must consist of one or more of several components, including walking surfaces, doors, ramps, and which of the following?
402.2
Transparent security glazing is permitted to be installed above the maximum height established for vertical barriers at service windows/counters.
904.3.1 Ex.
Accessible parking spaces required by Section 1106.2 must be identified by the International Symbol of Accessibility, except where the total number of parking spaces provided is what amount or less?
1112.1
In Type B units, if an accessible route making a 180-degree turn has a clear width of 60 inches (1525 mm) minimum during the turn, what is the minimum clear width required approaching and leaving the turn?
1104.4.1 Exception
Jury boxes and witness stands must provide a clear floor space, except in alterations where wheelchair spaces are permitted to be located outside the defined area if what prevents placement within the area?
807.3 Ex.
For Accessible routes within Type A units, an accessible route is not required to which part of the unit?
1103.3.1 Exception
Where Accessible units include elevators within the unit, those elevators must comply with Section 407, 408, 409, or which other section of the code?
1102.7
What is the raised symbol required on the function key surface for “Enter or Proceed”?
707.6.1, Table 707.6.1
In Type C (Visitable) Units, the unit entrance must be on a circulation path from a public street or sidewalk, a dwelling unit driveway, or what other location?
1105.2
The requirements for Type A dwelling or sleeping units (Group R-2) apply only to the quantity of units being altered or added where more than how many units are being altered or added?
IEBC 306.7.11.2
If a sales and service counter utilizes a parallel approach, what is the minimum required length of the accessible portion of the counter surface?
904.3.2
Where induction hearing loop systems are provided, they must comply with which IEC standard?
706.3
A required accessible floor located four or more stories above or below a level of exit discharge must have at least one accessible means of egress component including which of the following?
1009.2.1
The maximum travel distance from any accessible space to an area of refuge shall not exceed what limitation?
1009.6.1
In new buildings and facilities, what is the minimum diameter required for a circular turning space?
304.3.1.1
Spacing between individual raised characters shall be what minimum distance measured at the top surface of the characters?
703.3.8
What is the prohibited use for visible notification appliances used to indicate unit smoke detection or building fire alarm activation in units with communication features?
1106.4.4
Where only one accessible route is provided, it shall not pass through which of the following spaces?
1104.5
What is the minimum depth required for a wheelchair accessible toilet compartment with a floor-mounted water closet?
604.9.2.1
The changing surface height of an adult changing station must be adjustable from 17 inches minimum to what maximum height above the floor?
613.4.3
What are the minimum required width and depth measurements for the clearance around a water closet in a Type A unit?
1103.11.2.4.2; 1103.11.2.4.3
For a Type B accessible route making a 90-degree turn, what is the minimum clear width required approaching the turn and leaving the turn?
1104.4.1 Exception
At least what percentage of holes on miniature golf courses shall be accessible?
1111.4.12.1
Operable parts of storage facilities shall comply with which section?
905.4
For a parallel approach counter, the top of the accessible counter surface shall be within what height range above the floor?
904.3.2
At pedestrian at-grade rail crossings not located within a street or highway, the edge of the detectable warning surface nearest the rail crossing shall be placed within what distance range from the centerline of the nearest rail?
705.7.5
In Type A units, what elements must at least one accessible route connect?
1103.3.1
If a closed-circuit communication system is provided for a unit with communication features, what element must the unit system interface include?
1106.7
In Type A units, where is the primary entrance not permitted to be located, unless it is the only entrance?
1103.2
According to Table 1111.4.9.1, what is the minimum number of accessible boat slips required for a facility providing 120 total boat slips?
1111.4.9.1, Table 1111.4.9.1
For a standard accessible water closet, the centerline must be located within what range from the side wall or partition?
604.2
In alterations, an existing threshold is permitted to be 3/4 inch maximum in height, provided that the height exceeding 1/4 inch has a beveled edge with a maximum slope of:
404.2.4
When elements of an existing elevator are altered, which other elevators must also have those elements altered?
IEBC 306.7.7
In new buildings, what is the minimum required clear floor area dimensions for a Private Residence Elevator?
409.4.1.1
In new buildings and facilities, what is the minimum depth required for a wheelchair space entered from the front or rear?
802.4.1
What is the required width range for an ambulatory accessible toilet compartment?
604.10.2
Carpet installed on an accessible floor surface shall have a maximum pile height of:
302.2
Boat slips and boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) minimum in width that extends for what distance?
1003.3.1
Where a swimming pool has less than 300 linear feet of swimming pool wall, what is the maximum number of accessible means of entry required?
1009.1.1
For front loading washing machines and clothes dryers, the bottom of the opening to the laundry compartment must be located within what height range above the floor?
611.4
For an accessible drinking fountain, the spout must be located what minimum distance from the vertical support?
602.2.4
Accessible parking spaces must be located on the shortest accessible route of travel from adjacent parking to where?
1106.7
Each required area of refuge shall be sized to accommodate one wheelchair space of 30 inches by 52 inches (762 mm by 1320 mm) for each increment of the occupant load served by the area of refuge. What is that occupant load increment?
1009.6.3
What sign identification is required at each door providing access to an area of refuge from an adjacent floor area?
1009.9
On accessible routes serving recreational boating facilities, where the total length of a gangway or series of gangways is 80 feet (24 m) minimum, gangways are NOT required to comply with which section?
1003.2.1
How many companion seats must be provided for each wheelchair space required in assembly areas?
1109.2.3
For historic structures, alternative accessibility requirements are permitted only when full compliance would threaten or destroy the historic significance, as determined by whom?
IEBC 306.7.18
In assembly and mercantile occupancies, where additional toilet fixtures are added, which accessible facility must be provided?
IEBC 306.7.14
In new buildings and facilities, what is the minimum depth required for a wheelchair space that is only entered from the side?
802.4.1
What title shall this document be known as?
101.1
Which sales or service counter type is explicitly exempt from complying with Section 904?
904.1 Ex.
In new buildings, one option for a 90-degree turn permits both legs to be 36 inches minimum in width, provided the interior corners are chamfered for a minimum of what dimension along both walls?
403.5.3.1
For low resolution VMS signs mounted 40 to 70 inches above the floor, and a viewing distance of less than 10 feet, what is the minimum character height?
703.7.4, Table 703.7.4
Objects located 9 inches minimum and 27 inches maximum above the floor of the wheelchair space are permitted to protrude what maximum distance along the front of the wheelchair space?
1002.4.4.3
In Type B units utilizing Option A, where a lavatory complying with Section 606 is permitted in the clearance of a parallel approach bathtub, what is the minimum length required for the remaining clearance in front of the bathtub?
1104.11.3.1.3.1
When required by Section 1009.1 of the International Building Code, how many accessible means of egress must be provided from an addition?
IEBC 306.6.1
In Type A units, all rooms served by an accessible route must provide what feature?
1103.3.2
In units with accessible communication features, is it permitted to use the same visible notification appliance to signal both unit smoke detection and building fire alarm activation?
1106.4.3
When utilizing Option A (Section 1104.11.3.1) for water closets in Type B units, the centerline of the water closet shall be located what minimum and maximum distance from one side of the required clearance?
1104.11.3.1.2.1
Where a mirror is located within the same toilet or bathing room but not over a lavatory, and is provided as an exception to the 40-inch rule, the bottom edge must be mounted at what maximum height?
603.3
In historic structures, which accessible element required by Chapter 10 of the International Building Code is specifically noted as not being required?
IEBC 306.7.18, Exception 1
An accessible route shall be provided to at least what percentage, but not less than one, of each type of bowling lane?
1111.4.3
In a Type A unit kitchen, where a clear floor space is positioned for a forward approach to a cooktop, what required clearance must be provided beneath the cooktop?
1103.12.5.4.2
In the raised position, the centerline of the pool lift seat shall be located what minimum distance from the edge of the pool?
1009.2.2
If automatic, motion sensor-type lighting switches are used to achieve the required illumination level for stairs, what is the minimum duration the illumination timers must be set for?
504.9.1
In new construction, elevator hall call buttons and keypads must be located within one of the reach ranges specified in what section?
407.2.1.1
In Accessible units, mirrors above lavatories required to comply with Section 606 shall have the bottom edge of the reflecting surface located no more than how many inches above the floor?
1102.11.2.2
For a manual swinging door in a new building, approached from the front (push side) and provided with both a closer and a latch, what is the minimum clearance required parallel to the doorway (beyond the latch side)?
404.2.3.2
What is the maximum cross slope permitted for a walking surface that is part of an accessible route?
403.3
In Type A units, what is the required height range for the top of the water closet seat above the floor?
1103.11.2.4.5
What is the maximum water temperature permitted to be delivered by bathtubs and showers?
607.8, 608.8
Which chapter’s provisions apply to general site and building elements when those elements are required to be accessible by the administrative authority’s scoping provisions?
501.1
Platform lifts shall not be attendant operated and must provide what type of operation for users?
410.1
For Type A units, reinforcement for the future installation of grab bars at shower compartments is required for grab bars and shower seats complying with Sections 608.3, 608.2.1.3, 608.2.2.3 and which other section?
1103.11.1
Which character styles are explicitly prohibited for visual characters?
703.2.3
Which of the following elements is generally required to comply with Section 309 for operable parts in Accessible units?
1102.9
In Type B units, reinforcement for two swing-up grab bars is permitted to be installed in lieu of reinforcement for rear wall and side wall grab bars at a water closet, provided what element is not available?
1104.11.1 Exception
To comply with Section 605.2, a wall-hung urinal rim must be located at what maximum height above the floor?
605.2
In nursing homes of Group I-2, Condition 1 occupancies, at least what percentage of each type of dwelling units and sleeping units shall be Accessible units?
1108.5.2.1
In Saunas and Steam Rooms, a turning space shall be provided, and where seating is provided, at least one bench must comply with which section?
612.2, 612.3
The height of the uppercase letter “I” for raised characters shall be within what minimum and maximum vertical range?
703.3.5
Where armrests are provided on seating in the immediate area of designated aisle seats, what type of armrests must be provided on the aisle side of the designated aisle seat?
802.8.1
In Type A units, thresholds at exterior sliding doors are permitted to be how high, provided they are beveled with a slope not greater than 1:2?
1103.5 Exception
In new buildings, where an accessible route makes a 90-degree turn, what is the minimum width required for both legs of the turn if the width of each leg is maintained for 28 inches minimum from the inner corner?
403.5.3.1
Hand operated flush controls for water closets primarily for children’s use must be installed at what maximum height above the floor?
604.11.6
For a top loading washing machine in a Type B unit, what type of approach must the clear floor space be positioned for?
1104.10.1
Existing elements that are not altered are permitted to have an unobstructed high side reach of what maximum height?
308.3.1
Assembly areas utilized for viewing motion picture projections with 300 seats or less are exempt from which dispersion requirement?
802.10.2 Ex. 2
In Type B units, clear floor spaces are required to be what minimum length and width?
1104.1.1
Bathtub enclosures shall not obstruct controls, faucets, shower and spray units, or obstruct what other critical function?
607.7
What must the administrative authority provide to ensure compliance with this standard?
203
Where a sign containing raised characters and braille is provided at double doors with one active leaf, where must the sign be located?
703.3.11
Vertical and inclined platform (wheelchair) lifts installed in accordance with ASME A18.1 are permitted to be used as a component of which element?
IEBC 306.7.9
In Type B units, what minimum length, measured from the wall to the end of the horizontal portion, must the reinforcement for a swing-up grab bar accommodate?
1104.11.1.1
When required, knee clearance shall be a minimum of 11 inches (280 mm) in depth at 9 inches (230 mm) above the floor, and a minimum of what depth at 27 inches (685 mm) above the floor?
306.3.3
In Accessible units, the clear floor space required at the bed must also serve what other function, complying with Section 906?
1102.15.4
For an obstructed high side reach where the reach depth exceeds 10 inches (255 mm) but is not more than 24 inches (610 mm), what is the maximum height allowed for the high side reach?
308.3.2
In Type C (Visitable) Units, if the food preparation area does not provide a cooktop or conventional range, what is the minimum permitted clearance between opposing cabinets/elements?
1105.7 Exception
For an unobstructed side reach, the clear floor space must allow a parallel approach, and the edge of the clear floor space must be what maximum distance from the element being reached?
308.3.1
What is the minimum dimension required for a ramp landing where the ramp changes direction between runs?
405.7.4
For a self-service storage facility with a total of 300 spaces, what is the minimum number of required accessible spaces?
1109.3, Table 1109.3
Handrail brackets attached to the bottom surface are permitted to obstruct what maximum percentage of the handrail length?
505.6
At least what percentage of all public entrances shall be accessible?
1105.1
What is the minimum required clear width for the circulation path within a Type C (Visitable) Unit?
1105.5.2.1
Which maneuvering clearance is explicitly NOT required in a toilet room or bathroom in Accessible units if that facility is not required to comply with Section 1102.11.2?
1102.5 Exception
Where a permanent wall is less than 10 feet behind a sign language interpreter station, it must serve as a backdrop and provide a monochromatic, low-luster finish up to what minimum height from the finish floor?
802.11.5
Knee and toe clearance is NOT required to extend beneath a drink surface provided that the depth of the drink surface does not exceed what maximum dimension?
902.2 Ex. 1
The provisions of Sections 306.1 through 306.7.16 apply to which of the following activities in existing buildings?
IEBC 306.1
Elevator doors must remain fully open in response to a car call for what minimum duration?
407.3.5
The technical criteria in this standard are based on the body sizes and functional abilities of adults and, in those sections where specifically noted, which other group?
103.1
Where a forward approach is provided to an accessible public telephone, the distance from the front edge of a counter within the enclosure to the face of the telephone shall be what maximum distance?
704.2.1.2
For classrooms with volumes between 10,000 cubic feet and 20,000 cubic feet (566 m3), the reverberation time (T60) shall not exceed what time?
808.2.1
What must be provided under the accessible counter utilizing a forward approach?
904.3.3
Visual characters must be mounted at what minimum height above the floor of the viewing position, measured to the baseline of the character?
703.2.9
In new miniature golf facilities, where golf balls rest, the area must be within what maximum distance of a clear floor space?
1007.3.2.1
Which type of alteration is exempt from the requirement to upgrade the accessible route, toilet facilities, and drinking fountains serving a primary function area?
IEBC 306.7.1, Exception 4
Speech output on an ATM must be capable of being interrupted and repeated by the user, and what control must be provided for the speech function?
707.8.1
Where more than the minimum number of drinking fountains is provided, what percentage of the total number of drinking fountains provided shall comply with the requirements for persons who use a wheelchair?
1110.7.2
In an assembly area with a seating capacity of 51 to 200, what is the required calculation for the minimum number of receivers for the assistive listening system?
1109.2.7.1, Table 1109.2.7.1
Exposed edges of carpet shall be fastened to the floor and have trim along the entire length that complies with which section?
302.2
The stroke width of a raised character, measured at the top surface, shall be what maximum percentage of the height of the uppercase letter “I”?
703.3.7.1
In on-street parallel parking where the adjacent sidewalk width exceeds 14 feet (4265 mm), what minimum width access aisle is required at street level?
502.9.1
Where an addition is constructed exclusively for an elevator, the elevator landing must have access to a horizontal exit or to a stairway with a width of not less than how many inches?
IEBC 306.6.1.1, Item 2
For water closets primarily for children’s use, what is the maximum height permitted for the top of the water closet seat above the floor?
604.11.4
Edge protection permitted at continuous clear openings on piers must be what maximum height and width?
1003.3.1
What action is required for water supply and drain pipes located under sinks in Type A units?
1103.12.4.4
Protruding objects on circulation paths within areas of sport activity are not required to comply with Section 307. Which other area is provided a similar exception, provided ground level accessible routes maintain vertical clearance?
1001.3
If the structural or operational characteristics of an amusement ride are altered to the extent that its performance differs from the original design, the amusement ride shall comply with the requirements for new construction found in which section?
IEBC 306.7.17
Where a toilet paper dispenser is located above the side grab bar, the dispenser outlet must be located within what maximum distance from the rear wall?
604.7.1
In new buildings (T-shaped turning space, Option 1), the interior corners at the intersection of each arm and the base must be chamfered for a minimum of what dimension along both the arm and the base?
304.3.2.1
The depth of an accessible bench seat shall be within what size range?
903.3
The terms “floor” or “floor surface” refer to which surfaces?
105.5
What is the maximum depth permitted for a removable in-tub seat?
610.2
An elevator car door reopening device shall be activated by sensing an obstruction passing through the opening at what two nominal heights above the floor?
407.3.3.1
Directional signage indicating the location of accessible means of egress must be provided at which location?
1009.1
In accessible stairs, what is the maximum permitted height for risers?
504.2
Where guards, barriers, or rails are provided, exterior accessible routes serving golf facilities shall be what minimum clear width?
1006.2
In assembly areas with spectator seating, wheelchair spaces shall comply with which section?
802.1
Where parking spaces are marked with lines, the width measurements of parking spaces and adjacent access aisles shall be made from which point?
502.3
What is the minimum height required for the raised characters used for floor designations at elevator hoistway entrances?
407.2.3.1
The minimum clear width requirement of 48 inches (1219 mm) between handrails is NOT required for accessible means of egress stairways if the stairway is accessed from a refuge area in conjunction with what other means of egress component?
1009.3.2, Exception 2
According to the accessible route requirements within Accessible units, an accessible route is NOT required to which area that is part of the unit?
1102.3.1 Exception
The exterior walls separating an exterior area for assisted rescue from the interior of the building must extend horizontally not less than how far beyond the landing on either side?
1009.7.2
Unless a clear or correct key is provided on an ATM/fare machine, how must each operable part be differentiated?
707.3
For a stairway to be considered part of an accessible means of egress, what is the minimum clear width required between handrails?
1009.3.2
In an assembly area with stepped or ramped aisles, one accessible means of egress is permitted if the common path of egress travel meets the requirements in which section?
1009.1, Exception 2
In Type B units utilizing Option A, what is the minimum clear floor length and width required in front of bathtubs with a forward approach?
1104.11.3.1.3.2
Spacing between the baselines of separate lines of visual characters shall be what minimum and maximum percentage of the character height?
703.2.8
Handrails are required on both sides of stairs and ramps, with an exception provided for which areas?
505.2
In Accessible units, maneuvering clearances are generally required by Section 404 at doorways. For which existing area is the existing door to a hospital patient sleeping room exempt from the requirement for space at the latch side?
1102.5 Exception
If an accessible single-user toilet room is provided due to technical infeasibility of altering existing toilet rooms, in addition to the International Symbol of Accessibility, the sign characters must meet the visual character requirements in accordance with which standard?
IEBC 306.7.12
The calculation for the Prescriptive Method for acoustics in a classroom with a volume less than or equal to 10,000 cubic feet requires the sum of the NRC x S products to be greater than or equal to what ratio of the room volume?
808.2.2
In existing buildings, if the clear width of an accessible route is reduced to 32 inches (815 mm) maximum for a segment of 24 inches maximum, what is the minimum length required to separate these reduced-width segments?
403.5.1
Where self-service shelves are provided in food service lines, at least what percentage, but not less than one, of each type provided shall be accessible?
1110.16.3
In Type B units, where exterior deck, patio, or balcony surface materials are impervious, what is the maximum distance the finished exterior impervious surface shall be below the floor level of the adjacent interior spaces?
1104.4.2 Exception
At the top and bottom of ramp runs, handrails shall extend horizontally above the landing for what minimum distance?
505.10.1
Where separate raised and visual characters are provided for the same information, what is the minimum permitted height for the raised uppercase letter “I”?
703.3.5 Ex.
Where the public use area is under 5,000 square feet, not more than how many accessible checkout aisles shall be required?
1110.16.1
Which of the following is an exception where accessible routes passing through parking facilities are NOT required to be physically separated from vehicular traffic?
507.1
In a Group R-2 occupancy, the alteration to Type A individually owned dwelling units shall be permitted to meet the provision for what other type of unit?
IEBC 306.7.3
Thresholds at doorways shall be what maximum height?
404.2.4
What is the required height range for at least one bed provided in an Accessible unit, measured from the floor to the top of the uncompressed mattress?
1102.15.3
A hand shower hose shall be what minimum length?
607.6, 608.5
In accessible stairs, what is the minimum required depth for treads?
504.2
What must the unit system interface include in a closed-circuit communication system?
1106.7
What is the minimum depth required for a urinal, measured from the outer face of the rim to the finished wall surface?
605.2
At least what minimum percentage of care recipient and visitor parking spaces serving outpatient physical therapy facilities that specialize in treating conditions that affect mobility shall be accessible?
1106.5
In a historic structure, if an entrance cannot be made accessible, a locked accessible entrance is permitted if it provides which feature?
IEBC 306.7.18.3
What is the minimum required clear width between the two handrails provided on a sloped entry?
1009.3.3
Which type of public telephone is explicitly exempt from providing a clear floor space?
704.2 Ex.
Where fixed or built-in storage elements such as cabinets, coat hooks, or lockers are provided in required accessible spaces, at least what percentage, but not less than one, of each type shall be accessible?
1110.12
What is the minimum clear width required for an interior accessible route in a new building or facility?
403.5.1
In Type A units, for fixtures not required to comply with Section 1103.11.2, reinforcement for grab bars may comply with Section 1104.11.1. In which specific location is reinforcement for the water closet side wall vertical grab bar component NOT required?
1103.11.1 Exception
Raised characters shall be separated from raised borders and decorative elements by what minimum distance?
703.3.8
In Type C (Visitable) Units, what is the maximum permissible height for thresholds at exterior sliding doors?
1105.5.3.2 Exception
A clear floor space must be positioned for which approach(es) to an element, unless otherwise specified?
305.5
For an addition constructed exclusively to accommodate an elevator to improve accessibility, what system must be provided at all elevator landings that are part of the addition?
IEBC 306.6.1.1, Item 1
All portions of counters required to be accessible shall be located adjacent to what element?
904.2
What is the minimum required length for the fixed rear-wall grab bar at an accessible water closet?
604.5.2
In Type B units, for a refrigerator/freezer where the clear floor space is positioned for a forward approach, what is the maximum offset permitted from the centerline of the appliance to the centerline of the clear floor space?
1104.12.2.5.2
The baseline of the lowest raised character shall be mounted at what minimum height above the floor?
703.3.10
Characters or braille shall NOT be located where on a pictogram sign?
703.5.2
Buildings and facilities designed and constructed to be accessible shall be in accordance with this code and which standard?
IEBC 306.3
A standard roll-in shower compartment (60 inches wide) must have a clearance adjacent to the open face that is 30 inches minimum in depth and what minimum length?
608.2.2.2
If vision lites are more than 66 inches (1675 mm) above the floor, are they required to comply with the 43-inch maximum bottom height rule?
404.2.10
Objects with leading edges between 27 inches (685 mm) and 80 inches (2030 mm) above the floor may protrude horizontally into a circulation path by what maximum distance?
307.2
What is the maximum operating force permitted for window types other than vertical or horizontal sliding windows?
506.2
Where additional toilet facilities are being added in occupancies requiring adult changing stations, which room must contain the adult changing station?
IEBC 306.7.15
When elongated openings exist in floor surfaces, how must the long dimension be placed relative to the predominant direction of travel?
302.3
For on-street parallel parking, if the adjacent sidewalk width is 14 feet (4265 mm) or less, an access aisle is not required, provided the parking spaces are located where?
502.9.1.2
Audible and visible alarms must be powered by a commercial light and power source and be permanently connected to which system?
702.1
In Type A units, which operable windows are required to comply with Sections 309.2 and 309.3?
1103.13.1
In recreational facilities, where additional bathing rooms are being added, which accessible facility must be provided?
IEBC 306.7.14
Type B dwelling or sleeping units required by Section 1108 of the International Building Code are required to be provided in historic buildings. (True/False)
IEBC 306.7.18.7
Where a facility provides direct access for pedestrians from a pedestrian tunnel to a building, how many entrances to the building from that tunnel must be accessible?
1105.1.3
The height of transfer steps in a transfer system shall be what maximum dimension?
1009.5.4
In a Type A kitchen, an adjustable height counter providing a work surface is permitted within what height range above the floor?
1103.12.3.2 Exception
The running slope of a ramp run shall be greater than 1:20 and not steeper than:
405.2
For Type B units, which area is specifically not required to be on an accessible route?
1104.3.1 Exceptions
Where drinking fountains for persons using wheelchairs and drinking fountains for standing persons are not located adjacent to each other, what must be provided?
1112.3
Where criteria in this standard differ from those of a document referenced in Section 106.2, which criteria shall prevail?
106.1
Where provided, one accessible passenger loading zone shall be provided in every continuous maximum of how many linear feet of loading zone space?
1106.9.1
What is the maximum distance permitted for the separation between corresponding dots in adjacent braille cells (measured center to center)?
703.4.3, Table 703.4.3
In Type B accessible routes, where the clear width is less than 60 inches (1525 mm), passing spaces must be provided at intervals of what maximum length?
1104.4.1 Exception
What is the maximum slope permitted in all directions for rail platforms?
805.5.1
A horizontal side-wall grab bar must extend what minimum distance from the rear wall?
604.5.1.1
For ambulatory accessible toilet compartments, grab bars shall be provided on which sides of the compartment?
604.10.4
When a TTY is in use, the touch surface of the keypads must be what minimum height above the floor?
704.5
In Type C (Visitable) Units, where must reinforcement be provided?
1105.6
Sloped entries for swimming pools shall extend to a depth of 24 inches minimum and what maximum depth below the stationary water level?
1009.3.2.1
Washing machines and clothes dryers provided in Accessible units must comply with which Section?
1102.1
At the top of a stair flight, handrails must extend horizontally above the landing for a minimum of 12 inches (305 mm), beginning directly above which point?
505.10.2
What is the minimum size required for elevator hall call buttons in the smallest dimension?
407.2.1.2
The spout on a wheelchair accessible drinking fountain shall be located what maximum distance from the front edge of the fixture, including bumpers?
602.2.4
When utilizing Option A (Section 1104.11.3.1) for water closets in Type B units, what is the minimum required clearance width around the water closet, measured perpendicular from the side of the clearance?
1104.11.3.1.2.2.1
In Type C (Visitable) Units, what are the minimum fixtures required in the toilet room or bathroom on the entrance level?
1105.6
What type of doors are required for elevators along accessible routes?
407.3.1
Raised characters shall be raised what minimum distance above their background?
703.3.2
In spaces utilized primarily for viewing motion picture projections, where tiered seating is provided, wheelchair space locations must be integrated into the tiered seating area on a riser or what alternative?
802.10.4.1
According to Table 1106.2, how many accessible parking spaces are required for a facility providing a total of 78 parking spaces?
1106.2, Table 1106.2
In existing buildings and facilities, what is the minimum diameter required for a circular turning space?
304.3.1.2
Platform boarding edges not protected by platform screens or guards must have what safety feature?
805.5.2
In Type A units, what are the clearance depth requirements around the water closet measured perpendicular from the rear wall?
1103.11.2.4.3
Where a forward reach is unobstructed, what is the maximum height permitted for the high forward reach?
308.2.1
In Accessible units, the clear floor space required at the bed (Section 1102.15.1) is also required to serve as what area?
1102.15.4
Wheelchair storage spaces provided for transfer devices must comply with Section 305 and shall not overlap what two critical areas?
1002.5.4
For a visual sign mounted greater than 70 inches and up to 120 inches above the floor, what is the minimum character height required if the horizontal viewing distance is 15 feet (4570 mm) or greater?
703.2.4, Table 703.2.4
A parking facility providing a total of 550 parking spaces must provide a minimum of how many accessible parking spaces?
1106.2, Table 1106.2
What is the maximum height permitted for the top of the counter or wall at a shooting facility firing position if shooting over it is required?
1010.3
In historic structures, an altered element or space is not required to be on an accessible route, unless required by which sections?
IEBC 306.7.18, Exception 2
What is the maximum force permitted for pushing or pulling open an interior hinged door?
404.2.8
Where elevator service is not provided in a structure, and the slopes of the planned finished grade measured between the entrance and all vehicular or pedestrian arrival points within 50 feet of the entrance are 10 percent or less, all units on that story shall be required to be Type B units. What percentage refers to the slope?
1108.7.1.2
Telephone entry systems shall comply with which ANSI/DASMA standard?
708.4
What is the maximum width permitted between the two required handrails on pool stairs?
1009.6.2
A jurisdictional body that adopts or enforces regulations and standards for the design, construction or operation of buildings and facilities is known as the:
107.5
A facility that is constructed or altered to be accessible shall be maintained accessible during what period?
IEBC 306.2
In Type B units, reinforcement for the rear wall grab bar at a water closet is required to be 24 inches (610 mm) minimum in length, centered on the water closet, only when which condition applies?
1104.11.1 Exception
The running slope of a walking surface that is part of an accessible route shall not be steeper than what ratio?
403.3
Where reinforcement for swing-up grab bars is provided at a water closet in a Type B unit, the reinforcement must accommodate a grab bar centered how far from the centerline of the water closet?
1104.11.1.1
A turning space is required within a toilet or bathing room. Where shall this turning space NOT be provided?
603.2.1
Where a folding seat is provided in a standard roll-in shower, on which wall must it be located?
608.2.2.3
The counter slope of the gutter or street at the foot of a curb ramp run shall be what maximum ratio?
406.5.4
Where benches are provided in wet locations, the seat surface shall be slip resistant and must not allow what condition?
903.7
Which occupancy group is explicitly exempt from the requirement for areas of refuge at stairways that are part of an accessible means of egress?
1009.3.3, Exception 5
For terms not specifically defined in this standard or in a referenced document, where shall their meaning be sought?
107.3
Spaces accessed only by ladders, catwalks, freight elevators, or very narrow passageways are exempt from compliance with Chapter 11. Which other means of access grants this exemption?
1103.2.7
In Type C (Visitable) Units, which interior spaces must be included on the entrance level and connected by a circulation path?
1105.4
Shoulder alignment between the companion seat and the wheelchair space occupant is considered to be 36 inches or more from the front and what distance or more from the rear of the wheelchair space?
802.7.2
The tops of tray slides in food service lines shall be located within what height range above the floor?
904.5.2
If provided, what is the minimum required length for handset cords in a two-way communication system?
708.3
In Accessible units, where are windows explicitly not required to comply with the operable window requirements of Section 506.1?
1102.13 Exceptions
A clear floor space positioned for which type of approach is generally required at accessible dining surfaces and work surfaces?
902.2
What is the minimum clear opening required for doorways intended for user passage in Type B units?
1104.5.2.1
Which element, complying with Section 903, must be provided within an accessible dressing, fitting, or locker room?
803.4
If a doorway without a door is more than 24 inches (610 mm) in depth, what is the minimum required clear opening width?
404.2.2
In the exception allowing a reduced clear pier width of 36 inches minimum and 24 inches maximum length, these segments must be separated by segments that are 60 inches minimum in width and what minimum length?
1003.3.1
Where dining surfaces for the consumption of food or drink are provided, at least what percentage of the dining surfaces for the seating and standing spaces shall be accessible?
1109.2.9.1
Signage required for areas of refuge and exterior areas for assisted rescue must include the International Symbol of Accessibility and comply with ICC A117.1 requirements for which types of characters?
1009.9
What method is permitted in lieu of speech output for visible output that is not displayed for security purposes (e.g., asterisks representing PINs)?
707.8 Ex. 1
For Group R-2 Type B dwelling or sleeping units, when the work area is greater than 50 percent of the aggregate area of the building, the Type B unit requirements apply only to what quantity?
IEBC 306.7.11.3
In a building, room, or space used for assembly purposes with fixed seating, an accessible route is NOT required to serve levels where:
1104.3
The top of the counter edge protection on the aisle side of a checkout counter shall be what maximum height above the top of the counter surface?
904.4.2
Which element is explicitly prohibited from being part of an accessible route?
402.3
In Type B kitchens, where a parallel approach is provided to the cooktop, the clear floor space must be centered on which element?
1104.12.2.3.3
In Type A unit kitchens, when is a space NOT required to provide an accessible work surface?
1103.12.3 Exception
Accessible dining surfaces and work surfaces shall comply with Section 902, with the exception of surfaces primarily for which user group?
902.1
In Type A units, a turning space is not required within closets or pantries, provided they are what maximum depth?
1103.3.2 Exception
Which type of stairway is NOT permitted as part of an accessible means of egress between stories, except when serving a mezzanine?
1009.3.1
Audible and visible alarms that are part of a building fire alarm system must be installed in accordance with which referenced standard?
702.1
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area, what is the minimum number of drinking fountains that shall be provided?
1110.7.1
The water stream flow from an accessible drinking fountain spout shall provide a minimum height of:
602.2.5
What is the maximum vertical height permitted for the top of the gripping surfaces of handrails above stair nosings or ramp surfaces?
505.4
At a wheelchair-accessible drinking fountain primarily for children’s use, what type of approach is permitted for the clear floor space?
602.2.1
In existing and new buildings, unless otherwise specified, what is permitted regarding door swing and turning spaces?
304.4
Each 10 feet of linear pier edge serving boat slips or boarding piers must contain at least one continuous clear opening of what minimum width?
1003.3.1
In units with accessible communication features, if visible doorbell signals are located in sleeping areas, what must be provided?
1106.5.1
In load or unload areas of amusement rides, where complying with Section 405.2 (ramp slope) is not structurally or operationally feasible, what is the maximum permitted ramp slope?
1002.2
What is the maximum horizontal gap permitted between the floor of the amusement ride and the floor of the load/unload area?
1002.4.3
What is the minimum required depth for the clearance around an accessible water closet, measured perpendicular from the rear wall?
604.3.2
Signs that provide direction to or information about interior spaces and facilities of the site shall comply with which section?
703.1.2
Where storage facilities are provided in Accessible units, at least one of each type must comply with Section 905. Which element is specifically exempt from this storage facility requirement?
1102.14 Exception
In Group R-2, R-3, and R-4 occupancies required to have Accessible, Type A, or Type B units, what minimum percentage of each type of parking space provided shall be accessible (but not less than one)?
1106.3
Receivers for assistive listening systems shall include what size standard monaural jack?
706.2
In Type A units, accessible routes shall consist of walking surfaces with a slope not steeper than:
1103.3.3
In which occupancy groups are two-way communication systems NOT required at elevator landings serving each accessible floor, according to an exception in Section 1009.8?
1009.8, Exception 6
At the bottom of a stair flight, the handrail extension must continue at the slope of the stair for a horizontal distance equal to what measurement beyond the bottom tread nosing?
505.10.3
In Type B units utilizing Option A (Section 1104.11.3.1), if multiple lavatories are provided in a single toilet and bathing area, how many lavatories are required to comply with Section 1104.11.3.1?
1104.11.3.1 Exceptions
Limited-use/limited-application elevators installed in accordance with ASME A17.1 are permitted to be used as a component of which element?
IEBC 306.7.8
In Accessible units, which specific element is NOT required to comply with Section 404.2.5 regarding maneuvering space between doors in a series?
1102.5 Exception
According to Table 1109.2.2.1, what is the minimum required number of wheelchair spaces for an assembly area with a seating capacity of 85?
1109.2.2.1, Table 1109.2.2.1
In alterations, when providing a counter complying with Section 904.3 would reduce the number of existing work stations, what minimum length is permitted for the accessible counter portion using a parallel approach?
904.3 Ex.
In assembly and mercantile occupancies, an accessible family or assisted-use toilet room shall be provided where an aggregate of how many or more male and female water closets is required?
1110.2.1
The tops of dining surfaces and work surfaces primarily for children’s use shall be located within what height range above the floor?
902.5.2
Where assembly seating has multiple distinct seating areas with amenities that differ from other areas, where must wheelchair space locations be provided?
802.10.3
Where multiple single-user toilet rooms or bathing rooms are clustered at a single location, at least what percentage, but not less than one room for each use at each cluster, shall be accessible?
1110.2
In units with accessible communication features, if a hard-wired electric doorbell is provided, where must the button or switch be located?
1106.5.1
What is the maximum force required to activate operable parts?
309.4
In Type A units, if a lavatory measuring 24 inches maximum in depth overlaps the water closet clearance, what is the minimum distance required from the centerline of the water closet to the side edge of the lavatory?
1103.11.2.4.4 Exception
In row seating, the companion seat must be located to provide shoulder alignment with the wheelchair space occupant, and the floor surface for the companion seat must be at what elevation?
802.7.2
The bottom tread surface of transfer steps in a transfer system must extend to a water depth of what minimum dimension below the stationary water level?
1009.5.4
What is the minimum length required for the horizontal fixed side-wall grab bar at an accessible water closet?
604.5.1.1
In a courtroom, the vertical access to elevated employee work stations is NOT required at initial construction, provided a ramp, lift, or elevator can be installed without requiring reconfiguration or extension of the courtroom or what else?
1109.4.1.4
At cut-through pedestrian refuge islands, detectable warning surfaces must be separated by a minimum length of surface without warnings, what is this minimum separation distance?
705.7.4
In a Type A U-Shaped kitchen, where counters, appliances, or cabinets are on three contiguous sides, what is the minimum required clearance between opposing elements?
1103.12.1.2
In Accessible units, what minimum Section must elevators within the unit comply with?
1102.7
The back support of a bench shall extend from a point 2 inches maximum above the seat surface to a point what minimum height above the seat surface?
903.4
What is the maximum height above the floor required for a work surface in a Type A unit kitchen?
1103.12.3.2
If a building fire alarm system is provided, where must the system wiring be extended within a unit required to have communication features?
1106.3
Which seating arrangement is NOT required to comply with the companion seat shoulder alignment requirement?
802.7.2 Ex.
When reinforcement is provided for grab bars and shower seats in Accessible units’ toilet facilities that do not comply with 1102.11.2, which condition allows this reinforcement to be omitted?
1102.11.1 Exception
An alteration of an existing building shall not impose a requirement for greater accessibility than that which would be required for:
IEBC 306.4
If it is technically infeasible to provide accessible dressing, fitting or locker rooms at the same location as similar types of rooms, where must the accessible room be provided?
IEBC 306.7.16
If a service entrance is the only entrance to a tenant space in a facility, that entrance shall be:
1105.1.6
What is the minimum required width for a standard accessible car parking space?
502.2
In historic structures, what is the minimum required width for the exterior accessible route, including curb ramps, from a site arrival point to an accessible entrance?
IEBC 306.7.18.1
What are the minimum required length and width for the clearance area provided in front of bathtubs in Type B units utilizing Option B (Section 1104.11.3.2)?
1104.11.3.2.3.1
Where visible notification appliances are provided in a unit with accessible communication features, they must comply with which section of the general code chapters?
1106.4.1
If edge protection on a fishing pier is provided by a curb or barrier, what is the minimum required height of the curb or barrier above the deck surface?
1005.4.1
For water closets in Type A units, what is the specific requirement for hand-operated flush controls?
1103.11.2.4.6
What is the definition of a “ramp” in this standard?
107.5
What does the definition of “accessible” describe?
107.5
In Type A units, what is the maximum permissible height for a threshold at exterior sliding doors, provided they are beveled with a slope not greater than 1:2?
1103.5 Exception
The accessible route to an accessible adult changing station shall not require travel through which specific area, in passenger transportation facilities and airports?
1110.4.3
In Type B units, what is the required approach for the clear floor space at the kitchen sink?
1104.12.2.1
In assembly areas with 300 or fewer seats, horizontal dispersion is not required if the wheelchair space locations are located within which quartile range of the row length?
802.10.1 Ex.
What is the minimum lighting level required for a public visual relay service booth?
704.7
For a clear floor space positioned for a parallel approach to a Type A refrigerator/freezer, what is the maximum permissible offset of the clear floor space centerline from the centerline of the appliance?
1103.12.5.6
When utilizing Option A (Section 1104.11.3.1) for water closets in Type B units, if a forward approach is provided, what is the minimum required clearance depth, measured perpendicular from the rear wall?
1104.11.3.1.2.2.3
What is the minimum required space between the grab bar and projecting objects located above the grab bar?
609.3
When required as part of a clear floor space, what is the minimum required depth for toe clearance beneath an element?
306.2.3
What are the minimum clear inside dimensions required for a transfer-type shower compartment?
608.2.1.1
In units with communication features, if a hard-wired electric doorbell is provided, activation of the button or switch must initiate what within the unit?
1106.5.1
What is the minimum clear width and length required for wheelchair spaces in amusement rides?
1002.4.4.1
Within animal containment areas not otherwise exempted, which requirement shall not be required?
1001.4
In Type A units, if a lavatory overlaps the water closet clearance, what is the minimum required length for the reinforcement of the rear wall grab bar, centered on the water closet?
1103.11.1 Exception
In dining and drinking areas, an accessible route is not required to a mezzanine provided the mezzanine contains less than 25 percent of the total combined area for dining and drinking and what other condition is met?
1109.2.9
The cumulative costs of providing the accessible route, toilet facilities and drinking fountains for an alteration affecting a primary function area are not required to exceed what percentage of the costs of the alterations affecting the area of primary function?
IEBC 306.7.1, Exception 1
In Accessible Units, what section dictates the requirements for walking surfaces that are part of the accessible route?
1102.4
Unless specifically stated, figures included in this document are considered what?
105.4
Unless otherwise specified, which of the following element clearances are permitted to overlap?
301.2
A clear floor space of 60 inches minimum by 96 inches minimum shall be provided within what golf course element?
1006.2.4
A pool lift shall be designed so that the seat will submerge to a water depth of what minimum dimension below the stationary water level?
1009.2.8
For a sliding door approached from the front, what is the minimum maneuvering clearance required perpendicular to the doorway in a new building?
404.2.3.3
In a Type B unit shower compartment, where the shower is the only bathing facility and has dimensions of 30 inches minimum depth and 44 inches minimum width, what is the minimum required length of clearance measured perpendicular from the control wall?
1104.11.3.1.3.3 Exception
Which chapter’s provisions apply to communication elements and features required to be accessible by the administrative authority’s scoping provisions?
701.1
Where a visitor communication system is provided at a location other than the unit entry door, the public or common-use interface must include the capability of supporting voice communication and what other communication type with the unit interface?
1106.6.1
Telephones provided within holding or housing cells must have what specific feature?
806.3.2
The stroke width of visual characters shall be what minimum and maximum percentage of the height of the uppercase letter “I” of the font?
703.2.6
In a kitchen space where a cooktop or conventional range is NOT provided, what is the minimum required clearance between all opposing base cabinets, countertops, appliances, and walls?
804.2.3
According to Table 802.9.2.2, for rows with 33 to 44 inches of row spacing and a riser height of 12 inches, what is the minimum required height of the wheelchair space location (P) over standing spectators?
802.9.2.2, Table 802.9.2.2
What is the raised symbol required on the function key surface for “Cancel”?
707.6.1, Table 707.6.1
Altered elements of existing elevators shall comply with which ASME standard?
IEBC 306.7.7
In Type B U-Shaped kitchens, where counters, appliances, or cabinets are on three contiguous sides, what is the minimum required clearance between opposing elements?
1104.12.1.2
Door hardware operated by a rotational motion (e.g., knob) shall require a maximum force of:
404.2.6
What is the maximum permitted protrusion for handrails into a circulation path?
307.2
In a pass-through kitchen, what is the minimum number of entries required?
804.2.1
Dwelling units and sleeping units are required to comply with Chapter 11 if they are designated as Accessible units, Type A units, Type B units, Type C (Visitable) units, or what other type of unit?
1101.1
For the maneuvering clearance at the primary entrance swinging door to a Type B unit, what is the minimum dimension required perpendicular to the door for the front approach direction on the push side?
1104.5.1 Exception
Bus route identification numbers on signs shall be visual characters complying with which section?
805.4
Where curbs or other constructed barriers prevent golf cars from entering a fairway, openings 60 inches minimum in width shall be provided at intervals not to exceed:
1006.3.2
Low resolution VMS characters must be in which case?
703.7.2
Where an addition is constructed exclusively for an elevator, the elevator may not serve a required accessible floor or occupied roof more than how many stories above or below the level of exit discharge?
IEBC 306.6.1.1, Item 3
On accessible routes located on miniature golf playing surfaces, what is the minimum required length for ramp landings?
1007.2
If a clear floor space is confined in an alcove and positioned for a parallel approach, the alcove shall be 60 inches (1525 mm) minimum in width where the depth exceeds what dimension?
305.7.1
Signs that identify permanent rooms and spaces must contain both raised characters and what other feature?
703.1
Where rail station sign space is limited, characters identifying routes and destinations shall not be required to exceed what maximum height?
805.6.2 Ex.
Which pictogram is NOT required to have text descriptors?
703.1.3 Ex.
In Type A unit kitchens, a clear floor space positioned for a forward approach to a sink is required, providing knee and toe clearance. Under what condition is a clear floor space providing a parallel approach permitted?
1103.12.4.1 Exceptions
Where stadiums, arenas, and grandstands have 15,000 fixed seats or more and provide audible public announcements, what must also be provided?
1109.2.7.3
Where an accessible means of egress serving an addition is within the existing building, the accessible means of egress in the existing building shall comply with which section?
IEBC 306.6.1, Item 2
A LULA elevator car shall provide a clear floor width of 42 inches (1065 mm) minimum. What is the minimum required clear floor area?
408.4.1
Two-way communication systems must provide which types of signals?
708.2
Detectable warning surfaces are required at pedestrian refuge islands, except when those islands are cut-through at street level and are less than what length in the direction of pedestrian travel?
406.6.2
In a pass-through kitchen, where counters or appliances are on two opposing sides, what is the minimum required clearance between them within kitchen work areas?
804.2.1
What type of communication must the public or common-use system interface support, in addition to voice, where a visitor communication system is provided?
1106.6.1
For an Accessible unit, the primary entrance door and all other doorways intended for user passage must comply with which Section?
1102.5
What is the standard minimum required width for a van parking space?
502.2
The operable parts of exercise machines and equipment shall not be required to comply with which section?
1004.3
The required clearance around the water closet is permitted to overlap which of the following fixtures/elements?
604.3.3
Chapter 11 contains criteria for which specific unit types?
202
What are the minimum required length and width for clear floor spaces in Type B units?
1104.1.1
Which of the following is NOT an element explicitly exempted from complying with the height and clear floor space requirements of Section 1104.9 for operable parts in Type B units?
1104.9 Exceptions
What is the minimum clear width required for the toe clearance that must be provided beyond the railing when utilizing an extended ground or deck surface for edge protection?
1005.4.2
Which of the following elements is explicitly excepted from complying with the height and operation requirements of Section 309?
309.1
In existing buildings and facilities, what is the minimum required width for an access aisle serving a passenger loading zone vehicle pull-up space?
503.3.2.2
In at least one sleeping area of Accessible units, what minimum percentage of the beds provided must comply with the accessible bed requirements of Section 1102.15?
1102.15
Changes in level within a required turning space are generally prohibited, with what exception?
304.2
A charging station, as defined in this chapter, shall consist of a grounded:
906.1
For an ambulatory accessible toilet compartment (Section 604.10), the water closet centerline must be located within what range from the side wall?
604.2
Where more than one means of egress is required from an accessible space, what is the minimum number of accessible means of egress required to serve each accessible portion of that space?
1009.1
Where specific criteria of this standard differ from the general criteria of this standard, which criteria shall apply?
105.1
In Type A unit kitchens, a clear floor space positioned for a forward approach to a work surface must provide what clearance requirement?
1103.12.3.1
In multilevel assembly seating areas, wheelchair spaces shall be provided on the main floor level and on one of each how many additional floor or mezzanine levels?
1109.2.4
In Type B units using Option A (Section 1104.11.3.1), what is the minimum width required for the clear floor space for a parallel approach lavatory, centered on the lavatory?
1104.11.3.1.1
In Type B units, what is the required location range for the reinforcement for a sidewall grab bar (24 inches minimum in length) if a 42-inch (1065 mm) grab bar (Section 604.5.1) is not possible?
1104.11.1 Exception
Which specific exception is listed regarding the force required for activation of operable parts?
309.4
A facility that is altered shall comply with the applicable provisions in Chapter 11 of the International Building Code, ICC A117.1 and Sections 306.7.1 through 306.7.18, unless which condition applies?
IEBC 306.7
According to Table 1108.6.1.1, how many total required Accessible units must be provided for a Group R-1 facility with 175 total units?
1108.6.1.1, Table 1108.6.1.1
What is the maximum running slope permitted for ramp runs connecting ground level play components?
1008.4.1.2.1
In Type A units, clearance for a bathtub may permit countertops and cabinetry at one end, provided the countertop and cabinetry can be removed, the floor finish extends under the cabinetry, and what other criteria is met?
1103.11.2.5.1 Exception
In units with accessible communication features, visible notification appliances used for smoke detection must be activated when?
1106.4.2
The distance between two hinged or pivoted doors or gates in series must be 48 inches (1220 mm) minimum plus:
404.2.5
Where additions contain dwelling or sleeping units, to what quantity of units shall the accessibility requirements apply?
IEBC 306.6
For water closets designed for assisted toileting, the length of the swing-up grab bar must be not less than what length, measured from the rear wall to the end of the grab bar?
1110.2.2.4
What is the minimum height required for the top of transfer platforms in play areas above the floor?
1008.4.2.1.2
In Type C (Visitable) Units, what is the minimum clear width required for doorways?
1105.5.3.1
Operable parts of door hardware shall be located within what height range above the floor?
404.2.6.1
Plumbing elements and facilities required to be accessible by scoping provisions adopted by the administrative authority shall comply with which chapter?
601.1
What is the minimum required width for exterior accessible routes, including curb ramps, in an existing building?
IEBC 306.7.6
What is the minimum clear width required for curb ramp runs, excluding any flared sides, and for blended transitions?
406.5.1
Which alterations are exempt from the requirement to upgrade the accessible route and facilities serving a primary function area, when limited solely to windows, hardware, operating controls, electrical outlets and signs?
IEBC 306.7.1, Exception 2
Where an alteration includes alterations to a non-accessible entrance, and the facility has an accessible entrance, the altered entrance is not required to be accessible unless required by which section?
IEBC 306.7.5
Which element is explicitly excepted from complying with the requirements of Section 905 (Storage Facilities)?
905.1 Ex.
Every required area of refuge shall have direct access to a stairway complying with Section 1009.3 and 1023, or access to which other component complying with Section 1009.4?
1009.6.2
For fixtures not required to comply with Section 1103.11.2 in Type A units, when is reinforcement for future installation of grab bars not required in a room containing only a lavatory and water closet?
1103.11.1 Exception
In a Group B facility, when the building occupant load is greater than 500, each public entrance required to be accessible shall have a minimum of one door that is what type of door?
1105.1.1, Table 1105.1.1
The scoping provisions provided by the administrative authority shall address the application of this standard to which conditions?
201
In Type A units, storage facilities must comply with Section 905, but which specific type of storage is exempted from this requirement?
1103.14 Exception
In assembly and mercantile occupancies, an adult changing station is required where family or assisted-use toilet or bathing rooms are required to comply with which section?
1110.4.1
In a standard roll-in-type shower, the seat must extend from the control wall to a point within what maximum distance of the compartment entry?
610.3
Which of the following elements in an Accessible unit must comply with Section 309 for operable parts?
1102.9
If a visual sign is mounted 40 to 70 inches above the floor and the viewing distance is less than 6 feet (1830 mm), what is the minimum character height required?
703.2.4, Table 703.2.4
Knee clearance is defined as the space beneath an element between 9 inches (230 mm) and what maximum height above the floor?
306.3.1
The companion seat provided next to a wheelchair space must be equivalent in size, quality, comfort, and amenities to the seats in the immediate area and must also be what?
802.7.1
In existing buildings, if space limitations necessitate a steeper ramp slope, what is the maximum rise permitted for a ramp with a slope steeper than 1:10 but not steeper than 1:8?
405.2
Emergency control buttons within an elevator car shall have their centerlines located at what minimum height above the floor?
407.4.6.4.1
Where a high forward reach is over an obstruction, and the reach depth over that obstruction is 20 inches (510 mm) maximum, what is the maximum height permitted for the high forward reach?
308.2.2
What is the primary purpose the clear floor space at the bed in an Accessible unit must also serve?
1102.15.4
What is the primary requirement for doors in dressing, fitting, and locker rooms regarding their swing?
803.3
What feature must the number Five key have on an accessible ATM numeric keypad?
707.5
What is the minimum width required for a single wheelchair space in an assembly area?
802.3
In units with accessible communication features, which standard must the audible notification component of unit smoke detection comply with?
1106.2
If compliance with Section 306.7 during an alteration is technically infeasible, what level of access must still be provided?
IEBC 306.7
Truncated domes must have a base diameter within what size range?
705.5.1
In play areas, where accessible routes serve ground level play components, what is the minimum required height for vertical clearance?
1008.4.1
What is the minimum clear length required for a ramp landing?
405.7.3
Where a curb is provided for edge protection on a ramp or landing, what is the minimum required height of the curb?
405.9.2.1
If a Type C (Visitable) unit includes a food preparation area, what is the minimum required clearance between all opposing base cabinets, counter tops, appliances, or walls within that area?
1105.7
Where reinforcement for swing-up grab bars is provided at a water closet in a Type B unit, what is the minimum clearance required from the centerline of the water closet to any side wall or obstruction?
1104.11.1.1
In Type B units, clear opening of swinging doors intended for user passage shall be measured between the face of the door and stop, with the door open how many degrees?
1104.5.2.1
In existing buildings and facilities, the clear deck space for a pool lift shall extend forward what minimum distance from a line located 12 inches behind the rear edge of the seat?
1009.2.3.2
In a toilet or bathing room, what is the maximum height permitted for shelves?
603.4
At service windows or counters, any vertical barrier between service personnel and customers shall be located at what maximum height above the floor?
904.3.1
An alteration or addition that decreases the accessibility of a building, facility or element thereof, below the requirements for new construction, is prohibited at what time?
IEBC 306.2.1
For recreational boating facilities, where the number of boat slips is not identified, each how many feet of boat slip edge provided along the perimeter of the pier shall be counted as one boat slip?
1111.4.9.1
Where an existing building undergoes a change of occupancy that includes alterations, such alterations shall comply with which section?
IEBC 306.5
Signs identifying van parking spaces must contain the designation “van accessible.” Where required, signs shall be located at what minimum height above the floor of the parking space, measured to the bottom of the sign?
502.7
In Type A units, which type of operable window is required to comply with Section 309.2 but is NOT required to comply with Section 309.3?
1103.13.2
Where an automatic door or gate is required at a public entrance, it must be either a full powered automatic door or gate or a:
404.3.1
Classrooms not exceeding 20,000 cubic feet and required to provide enhanced acoustics shall comply with which section?
808.1
Visual characters (not VMS or combined with raised) shall use which combination of character case?
703.2.2
What type of bed frame is required for at least one bed in an Accessible unit?
1102.15.2
In new buildings, a doorway without doors or gates that is less than 36 inches (915 mm) in width, approached from the front, must have what minimum maneuvering clearance perpendicular to the doorway?
404.2.3.4
Rail station signs identifying a station or station entrance must provide at least one sign with raised characters and braille complying with which two sections?
805.6.1
In a new building, reduced width segments (32 inches minimum) on an accessible route must be separated by segments of what minimum length and width?
403.5.1
For bathtubs with permanent seats, two horizontal grab bars are required on the back wall. The upper bar must extend to within what maximum distance from the control end wall?
607.4.1.1
Grab bars on a transfer wall must be perpendicular to the pool wall and their gripping surface must be located within what height range above the transfer wall?
1009.4.5
Where required, which space within an Accessible unit is NOT required to provide a turning space?
1102.3.2 Exception 2
In Accessible units, at least one toilet and bathing facility must comply with Section 603, and the fixtures (lavatory, water closet, tub/shower) must comply with Sections 604 through 610. Where must these fixtures be located?
1102.11.2
Where central holding cells are provided and are not separated by age or sex, what is the minimum number of accessible cells required?
1109.4.2.1
Where railings, guards, or handrails are provided along the perimeter of fishing piers or platforms, what minimum percentage of these must be 34 inches (865 mm) maximum in height above the ground or deck surface?
1005.3.1
In existing buildings, what is the minimum maneuvering clearance perpendicular to the door required for a manual swinging door approached from the front (push side)?
404.2.3.2
What is the minimum clear width required for a ramp run?
405.5
If public address systems convey audible information to the public in transportation facilities, the same or equivalent information must be provided in what format?
805.7
In new construction, if the inside car dimension from side to side is 60 inches (1525 mm) minimum, what is the minimum required depth from back wall to inside face of door?
407.4.1
The permitted projection of the nosing beyond the riser shall be what maximum dimension?
504.5
A door closer must be adjusted so that from an open position of 90 degrees, the time required to move the door to an open position of 12 degrees shall be at least how long?
404.2.7.1
A public pay telephone designed to accommodate a portable TTY must be equipped with a shelf having a vertical clearance of what minimum height above the area where the TTY is placed?
704.6
For a manual swinging door in a new building, approached from the front (pull side), what is the minimum maneuvering clearance required perpendicular to the doorway?
404.2.3.2
For an elevator to be considered part of an accessible means of egress, standby power must be provided in accordance with Chapter 27 and which other section?
1009.4.1
What is the minimum number of accessible means of egress required from an accessible mezzanine level?
1009.1, Exception 1
In Type A units, what is the maximum permissible height for the front of a sink, measured to the higher of the rim or counter surface?
1103.12.4.2
Directions for the use of the two-way communication system, instructions for summoning assistance, and written identification of the location must be posted adjacent to the system and comply with ICC A117.1 requirements for:
1009.8.2
Where pictograms are provided as permanent room or space designations, they must comply with Section 703.5 and have text descriptors complying with Sections 703.2 and 703.3 located where?
703.1.3
In new buildings and facilities, what is the minimum clear length required for a bus stop boarding and alighting area, measured perpendicular to the curb or vehicle roadway edge?
805.2.2.1
In Accessible units, where are doors permitted to be exempt from the maneuvering clearance required at the latch side of the door?
1102.5 Exception
What minimum percentage of the total number of aisle seats provided shall be designated aisle seats?
1109.2.5
A continuous passage on which a motorized golf car can operate is defined as a:
107.5
Where the elevator emergency communication system is altered or replaced, that system shall comply with which section of the International Building Code?
IEBC 306.7.7
Back support for benches must be located what maximum distance from the rear edge of the seat, measured horizontally?
903.4
Which referenced document listed in Section 106.2 addresses criteria for Transportation Vehicles?
106.2.1
If the central control point for the two-way communication system is not constantly attended, the system must have timed, automatic telephone dial-out capability to an approved supervising station or what other entity?
1009.8.1
For bus stop boarding and alighting areas, what is the maximum slope permitted perpendicular to the vehicle roadway?
805.2.3
Access aisles serving parking spaces shall extend for what distance?
502.4.3
Furnishings and equipment required to be accessible shall comply with which chapter?
901.1
Which organization publishes the referenced document dealing with Magnetic Field Strength in Audio-Frequency Induction Loops for Hearing Aids?
106.2.2
In a standard roll-in-type shower compartment, what is the minimum required width?
608.2.2.1
Open risers are permitted in accessible stairs under which condition?
504.3
What is the maximum slope permitted for flared sides of a perpendicular curb ramp where a pedestrian circulation path crosses the ramp?
406.2.3
When edge protection is provided by an extended floor surface, the floor surface must extend at least what distance beyond the inside face of the railing?
405.9.1
A side maneuvering clearance provided at the open long side of the adult changing surface must be what minimum depth?
613.4.4.1
In Type A units, what is the required maximum vertical height of thresholds at exterior sliding doors, provided they are properly beveled?
1103.5 Exception
When utilizing Option A for water closets in Type B units, a vanity or obstruction is permitted to overlap the required clearance provided the obstruction is what maximum depth, and the remaining clearance width is what minimum measurement?
1104.11.3.1.2.2.4
Pool lifts must be located where the water level does not exceed what maximum depth?
1009.2.1
Where two adjacent wheelchair spaces are provided in an assembly area, what is the minimum required width for each wheelchair space?
802.3
A van parking space is permitted to be reduced to 96 inches (2440 mm) minimum in width, provided the adjacent access aisle has what minimum width?
502.2
Interior and exterior signs identifying permanent rooms and spaces shall comply with which three sections?
703.1.1
For bottom-hinged door ovens, the required accessible work surface must be positioned adjacent to which location?
804.5.5.3
The vertical grab bar on the side wall shall be 18 inches minimum in length and mounted with its bottom edge located within what height range above the floor?
604.5.1.2
Changes in level in floor surfaces that are 1/4 inch (6.4 mm) maximum in height are permitted to be installed in what manner?
303.2
For ramps that are part of the circulation path in Type C (Visitable) Units, when are handrails, intermediate landings, and edge protection NOT required?
1105.5.4 Exception
What is the maximum cross slope permitted for ramp runs?
405.3
Accessible units must comply with all requirements in which section?
1102.1
In Type B units, which type of operable part is specifically exempted from complying with Sections 309.3 and 1104.1.1?
1104.9 Exception
When calculating required size or dimension involving ratios or percentages, rounding down for values less than what fraction shall be permitted?
105.2
Where unit smoke detection is provided in a unit with accessible communication features, what element must be included for notification?
1106.2
The technical criteria intended to make sites, facilities, and buildings accessible are primarily found in which section range of this standard?
102.1
For the maneuvering clearance at Type B unit primary entrance doors, for a front approach sliding or folding door, what minimum dimension is required perpendicular to the door?
1104.5.1 Exception
In Type C (Visitable) Units, what are the minimum and maximum heights above the floor for receptacle outlets and operable parts of lighting controls?
1105.8
In a Type A unit combination refrigerator/freezer, what percentage and height requirement applies to the freezer compartment shelves?
1103.12.5.6
In existing buildings and facilities, what is the minimum clear length required for a bus stop boarding and alighting area, measured perpendicular to the curb or vehicle roadway edge?
805.2.2.2
What is the minimum required vertical clearance for vehicle pull-up spaces and their access aisles at passenger loading zones?
503.5
For hand-operated flush controls in Type A water closets, where must the control be located?
1103.11.2.4.6
Where adult changing stations are provided in a single-user toilet room, which component must be provided in the room?
613.2.1
If a permanent seat is provided at the head end of an accessible bathtub, the required clearance in front of the tub must extend what minimum distance beyond the wall at the head end?
607.2
If a Type C (Visitable) Unit entrance is provided via a circulation path, that path must lead from a public street or sidewalk, a dwelling unit driveway, or what other location?
1105.2
Type A dwelling units shall comply with which section of the code?
1103.1
The width of the uppercase letter “O” for visual characters shall be what percentage range of the height of the uppercase “I” of the font?
703.2.5
What is the minimum illumination level required for interior stairways during conditions of stair use?
504.9.1
In standard roll-in showers, the back-wall grab bar must extend within what maximum distance from the adjacent side wall opposite the seat?
608.3.2.1
In Type B units, lighting controls and receptacle outlets located over cabinets with countertops are permitted, provided the countertop is what maximum height and maximum depth?
1104.9 Exception
If it is technically infeasible to alter existing toilet rooms to be accessible, what alternative accessible facility is permitted on the same floor and in the same area?
IEBC 306.7.12
If a shower compartment is the only bathing facility in a Type B unit (Option A), and has minimum dimensions of 36 inches by 36 inches, what is the minimum length and depth required for the clearance area measured from the control wall?
1104.11.3.1.3.3
Seating treads less than 33 inches (840 mm) in depth shall not be permitted with risers greater than what height?
802.9.2.2, Note 3
Detectable warning surfaces shall extend what minimum distance in the direction of pedestrian travel?
705.6
What is the minimum clear opening width required for a doorway?
404.2.2
What is the minimum required length for an accessible bench seat?
903.3
For a swinging door, the clear opening width shall be measured between the face of the door and the stop with the door open to what degree?
404.2.2
Which referenced document addresses performance criteria for Accessible Communications Entry Systems?
106.2.5
In existing buildings and facilities, what is the minimum depth required for a wheelchair space that is only entered from the side?
802.4.2
Changes in level greater than 1/4 inch (6.4 mm) and not more than 1/2 inch (13 mm) maximum shall be beveled with a slope not steeper than what ratio?
303.3
Dwelling units and sleeping units shall comply with the applicable provisions of which chapter of this standard?
102.2
The requirements for Accessible dwelling or sleeping units (Group I-1, I-2, I-3, R-1, R-2, or R-4) being altered or added apply only to:
IEBC 306.7.11.1
What is the specific description of a “blended transition”?
107.5
If stair nosings are rounded, what is the maximum permitted radius of curvature at the leading edge of the tread?
504.5
If platform lifts are installed within an Accessible unit, they must comply with which section?
1102.8
What is the minimum height and depth of knee clearance required at accessible play tables?
1008.4.3.3
For audible car position indicators, the verbal announcement indicating the floor shall be completed prior to what action?
407.4.9.2.1
How many van-accessible parking spaces must be provided for every 10 accessible parking spaces?
1106.6
In Type C (Visitable) Units, the water closet must comply with clearances specified in which section?
1105.6
What is the maximum height permitted for thresholds in roll-in-type shower compartments?
608.6
What is the maximum permitted height for the top of an accessible water closet seat above the floor?
604.4
A clear floor space positioned for a parallel approach to a refrigerator/freezer shall have its centerline offset what maximum distance from the centerline of the appliance?
804.5.6
In new buildings and facilities, what is the minimum required length and width for a clear floor space?
305.3.1
In Type B units utilizing Option A, if a shower compartment is the only bathing facility, and has minimum dimensions of 36 inches by 36 inches, how wide is the clearance required from the face of the shower compartment?
1104.11.3.1.3.3
Classroom ambient sound levels shall not exceed what maximum sound level due to intruding noise from sources outside of the classroom?
808.3.1
In historic structures where toilet rooms are provided, the requirement is for not fewer than one accessible single-user toilet room or:
IEBC 306.7.18.4
The floor surface of wheelchair spaces in amusement rides shall have a slope not steeper than what ratio when in the load and unload position?
1002.4.2
Charging stations shall comply with at least one of the reach ranges specified in which section?
906.3
Platform lifts used as part of an accessible means of egress must be provided with standby power in accordance with which chapter?
1009.5
What is the maximum height permitted for the spout outlet of a drinking fountain designed for persons using wheelchairs?
602.2.3
In existing buildings, where an accessible route makes a 180-degree turn around an object less than 48 inches in width, what are the minimum widths approaching, during, and leaving the turn?
403.5.2.2
If vertical clearance is reduced below the minimum required, a rail or barrier must be provided, and the leading edge of this barrier must be located at what maximum height above the floor?
307.4
The administrative authority shall specify the extent to which the dwelling and sleeping unit criteria apply using what method?
202
What is the minimum required height for a pictogram field?
703.5.2
Where check writing surfaces are provided, they must comply with which section?
904.4.3
At least one section of accessible counter/work surface in a Type A unit must be provided with a minimum length of:
1103.12.3
In Group I-1, Condition 1 occupancies, what is the minimum percentage of dwelling units and sleeping units that shall be Accessible units?
1108.5.1.1
Seating within an arc measured from the sign language interpreter station must be provided with sight lines viewing the station from a horizontal distance of what maximum length?
802.11.3
In Type C (Visitable) Units, which item is explicitly NOT required to comply with the height requirements of Section 1105.8?
1105.8 Exception
What is the maximum rise permitted for any single ramp run?
405.6
Wheelchair space locations in assembly areas must be provided with a companion seat complying with Section 802.7 located where?
802.7
In general-purpose hospitals, psychiatric facilities, and detoxification facilities of Group I-2 occupancies, what is the minimum percentage of dwelling units and sleeping units that shall be Accessible units?
1108.5.3.1
At least two percent of the total, but not fewer than one, of each gaming machine type and gaming table type shall be accessible. What other requirement applies when multiple gaming areas occur?
1110.19
What is the minimum required length for the changing surface of an adult changing station?
613.4.1
For historic structures, the alteration to Type A individually owned dwelling units within a Group R-2 occupancy is permitted to meet the provision for which type of unit?
IEBC 306.7.18.6
Where side rails are provided at the changing surface, they shall be a minimum of what fraction of the length of the changing surface?
613.4.5.1
Which alterations are exempt from the requirement to upgrade the accessible route, toilet facilities, and drinking fountains serving an area of primary function?
IEBC 306.7.1, Exception 3
If edge protection on a fishing pier is provided by an extended deck surface, the deck surface must extend what minimum distance beyond the inside face of the railing?
1005.4.2
In Type A units, where is a countertop required to be positioned relative to a side-hinged door oven?
1103.12.5.5.2
Within areas of sport activity exempted in this chapter, which requirement for floor and ground surfaces is not required to be met?
1001.2.2
Where one grab bar is provided on a transfer wall, what minimum clearance must be maintained on both sides of the grab bar?
1009.4.5
What is the minimum required length for the telephone handset cord for a public telephone?
704.2.4
Stair level identification signs in enclosed stairways must be located where?
504.1
Spacing between individual visual characters (excluding word spaces) shall be measured between the two closest points of adjacent characters and be within what percentage range of the character height?
703.2.7
The uppercase letter “I” on an ATM display screen shall be what minimum height?
707.7.2
What is the minimum clear width required for an exterior accessible route?
403.5.1
Where provided in an Accessible unit, kitchens shall comply with which section of the code?
1102.12
In a U-shaped kitchen (enclosed on three contiguous sides), what is the minimum required clearance between opposing base cabinets, countertops, appliances, or walls within the kitchen work area?
804.2.2
When determining the minimum character height for visual characters, what letter is used to determine the allowable height of all characters of a font?
703.2.4
Braille shall be 48 inches (1220 mm) minimum and what maximum height above the floor, measured to the baseline of the braille cells?
703.4.5
In a Type B kitchen, if two or more receptacle outlets are provided above a length of countertop that is uninterrupted by a sink or appliance, how many receptacle outlets must comply with the operable parts requirements (Section 1104.9)?
1104.9 Exception
Accessible pedestrian signals must comply with which section of the Manual on Uniform Traffic Control Devices?
703.9
What is the maximum size for interior common use circulation paths within employee work areas that are defined by permanently installed partitions, counters, casework or furnishings, to be exempt from being required accessible routes?
1104.3.1
Grab bars provided on each transfer step in a transfer system must have their gripping surface located within what height range above each step?
1009.5.7
In Group R-2 occupancies containing more than 20 dwelling units or sleeping units, what is the minimum percentage of the units that shall be a Type A unit?
1108.6.2.2.1
The provisions of Chapter 3 (Building Blocks) apply where required by the administrative authority’s scoping provisions or by which subsequent chapters?
301.1
In Accessible units, if doors leading to a balcony have exterior space dimensions less than the required maneuvering clearance, what is the exemption applied to the exterior side of the door?
1102.5 Exception
Where a high side reach is over an obstruction, what is the maximum height permitted for that obstruction?
308.3.2
Which raised structure, used solely for a sports activity, is generally NOT required to comply with this standard?
1001.2.1
The front of accessible lavatories and sinks shall be located at what maximum height above the floor, measured to the higher of the rim or counter surface?
606.3
Accessible van parking spaces and their access aisles must be provided with what minimum vertical clearance?
502.6
Within a clear floor space, changes in level shall not be permitted, with the exception of slopes not steeper than what ratio?
305.2
What is the minimum vertical clearance required for circulation paths?
307.4
One option for a required passing space in a new building is a 60-inch minimum by 60-inch minimum space. What is the alternative option?
403.5.4.1
What is the minimum number of sloped entries required for a wading pool?
1009.1.2
Signs complying with IBC Section 1112 must be provided at the public entrances and which other entrance in a historic structure?
IEBC 306.7.18.3
Raised characters must be of which style?
703.3.4
For an exterior area for assisted rescue, the sides other than the separation walls shall be open to the outside air by a minimum percentage of:
1009.7.3
Accessible routes within Accessible units may consist of walking surfaces, ramps, elevators, platform lifts, and which other component?
1102.3.3
For Accessible units, clear floor space is required on both sides of the bed, positioned for a parallel approach. What is permitted as an exception to this rule?
1102.15.1 Exception
Objects located more than 27 inches above the floor of the wheelchair space are permitted to protrude what maximum distance along the front of the wheelchair space?
1002.4.4.3
What is the minimum required range of view for peepholes, where used, as a means for visually identifying a visitor at the unit primary entrance in units with communication features?
1106.5.2
What kind of space must be provided in load and unload areas of amusement rides?
1002.3
What is the maximum slope permitted for the floor surface of wheelchair space locations in assembly areas?
802.2
In a Type A unit bathroom complying with Section 1103.11.2.2, if cabinetry is permitted under the lavatory, what specific finishing requirement must be met for the walls?
1103.11.2.2 Exception
Clear floor spaces required at accessible gaming machines and tables shall be permitted to do what?
907.1
In Type B units, mailboxes serving the unit are permitted an unobstructed side reach range at what maximum height above the floor?
1104.1.2
What is the exception to the 80-inch minimum vertical clearance requirement?
307.4
Accessible benches must be able to support a vertical or horizontal force of what minimum weight applied at any point on the seat?
903.6
Existing means of egress need not be maintained during construction where what alternative condition is met?
IEBC 306.2, Exception
What is the maximum age defining “children’s use” spaces and elements?
107.5
For visible hall signal fixtures, the center shall be located at what minimum height above the floor?
407.2.2.2
For a Type A refrigerator/freezer where a parallel approach is provided, what is the maximum offset permitted between the centerline of the clear floor space and the centerline of the appliance?
1103.12.5.6
Stairways that are part of an accessible means of egress must either incorporate an area of refuge within an enlarged floor-level landing or be accessed from an area of refuge complying with which section?
1009.3.3
Where play components require transfer to entry points or seats, the entry point or seat height shall be what maximum dimension from the clear floor space?
1008.4.3.4
A clear floor space 48 inches minimum by 60 inches minimum with slopes not steeper than 1:48 shall be provided at which location in miniature golf facilities?
1007.3.1
Where benches are provided, the clear floor space must be positioned at the end of the bench seat and parallel to which axis of the bench?
903.2
Special rooms and spaces required to be accessible shall comply with the applicable provisions of which chapter?
801.1
What is the minimum vertical force required to be structurally supported by grab bars?
609.8
What is the minimum required base-to-base spacing for adjacent truncated domes on the grid?
705.5.3
Which term describes a space for a single wheelchair and its occupant?
107.5
Signage identifying access to an exterior area for assisted rescue must state:
1009.9
Where a high forward reach is over an obstruction, and the reach depth over the obstruction is greater than 20 inches (510 mm) and not more than 25 inches (635 mm) maximum, what is the maximum height permitted for the high forward reach?
308.2.2
If a VMS message can be displayed in its entirety on a single screen, it must remain motionless on the screen for a minimum of 3 seconds or a minimum of one second for every how many characters, whichever is longer?
703.7.14
What is the minimum diameter required for the base of a single braille dot?
703.4.3, Table 703.4.3
Cabinetry is permitted under a lavatory in a Type A unit bathroom complying with Section 1103.11.2.2, provided the cabinetry can be removed without removal or replacement of the lavatory, the walls behind are finished, and what other criterion is met?
1103.11.2.2 Exception
Hand-operated metering faucets must remain open for what minimum duration?
606.4
For line of sight over standing spectators, the front of the wheelchair space shall be located what maximum distance from the back of the chair or bench in front?
802.9.2.1
Where more than three clothes dryers are provided in spaces required to be accessible, what is the minimum number that must be accessible?
1110.6.2
The display screen of an ATM must be visible from a point located at what height above the center of the clear floor space in front of the machine?
707.7.1
What is the stated intent of the technical criteria in Chapters 3 through 10?
102.1
For an Accessible unit, the primary entrance is required to be on an accessible route from public and common areas. Under what condition is the primary entrance permitted to be located to a bedroom?
1102.2
For a parallel approach counter, what is the minimum required space between the accessible counter surface and any projecting objects above it?
904.3.2
Wheelchair accessible toilet compartment doors shall be self-closing, and where shall a door pull complying with Section 404.2.6 be placed?
604.9.3
For drinking fountains for persons who are standing, what is the minimum height required for the spout outlet above the floor?
602.3.2
What is the minimum elevated height above grade required for shooting facilities on freestanding platforms to be exempt from this standard, provided the aggregate area is 500 square feet maximum?
1001.2.1
Built-in storage facilities shall comply with at least one of the reach ranges specified in which section?
905.3
Raised areas used primarily for purposes of security, life safety, or fire safety, such as observation galleries and prison guard towers, are exempt from Chapter 11 requirements, except when the area is what size?
1103.2.6
In Group I-3 occupancies, what minimum percentage of the total number of sleeping units in the facility shall be Accessible units?
1108.5.5.1
What must identify assistive listening systems?
703.6.3.3
Assistive listening systems must be capable of providing a sound pressure level within what range?
706.5
What is the maximum horizontal distance that a beveled nosing shall extend at the leading edge of a stair tread?
504.5
The nonglare finish requirement for symbols of accessibility and their backgrounds shall not exceed how many gloss units (gu)?
703.6.2.1
Dwelling units and sleeping units required to have communication features shall comply with which section?
1106.1
What element is NOT listed as a component that an accessible route may consist of in Accessible Units?
1102.3.3
What is the minimum size of the level and clear floor area required for a sign language interpreter station?
802.11.2
For Type B units, the clear width of an accessible route is generally required to comply with Section 403.5, but is permitted to be reduced to 32 inches minimum for what maximum length?
1104.4.1 Exception 1
For a water closet required to comply with Section 1103.11.2.4 in a Type A unit, what is the required minimum and maximum measurement for the centerline of the water closet from the sidewall?
1103.11.2.4.1
In a Type A toilet/bathing facility required to comply with Section 1103.11.2, doors are permitted to swing into the clear floor space or clearance for a fixture under which condition?
1103.11.2.1 Exception
According to Table 1110.16.1, what is the minimum number of accessible checkout aisles required for a facility providing 12 total checkout aisles of the same function?
1110.16.1, Table 1110.16.1
When measuring the width of visual characters, which uppercase letter is used to determine the allowable width?
703.2.5
Where more than one accessible means of egress is required, what is the minimum fire-resistance rating required for exterior walls separating an exterior area for assisted rescue from the interior of the building?
1009.7.2
The height of a transfer wall shall be 16 inches minimum and what maximum height measured from the deck?
1009.4.2
For bathtubs with removable seats, a horizontal grab bar 12 inches minimum in length must be provided on which wall?
607.4.2.3
In cells required to have communication features, where audible emergency alarm systems are provided, visible alarms must comply with Section 702, except in cells where inmates or detainees are not allowed what?
806.3.1 Ex.
Instructions posted in areas of refuge or exterior areas for assisted rescue must include that persons able to use the exit stairway should do so as soon as possible, unless they are engaged in what activity?
1009.11
In a transfer system, what is the minimum clear depth required for the transfer platform?
1009.5.1
A two-way communication system is required at elevator landings on each accessible floor that is how far above or below the level of exit discharge?
1009.8
Toe clearance is defined as the space beneath an element between the floor and what minimum height above the floor?
306.2.1
Which of the following Group U occupancies is required to comply with Chapter 11?
1103.2.4
In a transfer-type shower, controls and hand shower shall be located on the control wall opposite the seat, at a height of 38 inches minimum and what maximum height above the shower floor?
608.4.1
During construction, demolition, remodeling, or alterations and additions to any occupied building, which elements must be maintained?
IEBC 306.2
Changes in level greater than 1/2 inch (13 mm) in height shall be accomplished by which means?
303.4
Accessible floor surfaces must be stable, firm, and what other characteristic?
302.1
Stair treads must have visual contrast provided by a solid color contrasting marking. This marking must cover what minimum and maximum horizontal distance, measured from the leading edge of the nosing?
504.6
An adult changing station and its support structure must be able to support a user weight of not less than what minimum amount?
613.4.2
What is the minimum clear width required for an escalator provided in a transportation facility?
805.9
Dining surfaces and work surfaces that are 15 inches minimum and 24 inches maximum in height are permitted to have a clear floor space positioned for which type of approach?
902.2 Ex. 2
Which specific sections provide criteria for Type B units, intended to be consistent with HUD Fair Housing Accessibility Guidelines?
1104
What is the required height of truncated domes?
705.5.2
What is the minimum required width and length for a vehicular pull-up space at a passenger loading zone?
503.2
A noncircular handrail cross section shall have a maximum cross-section dimension of:
505.7.2
In Type B units, which area is NOT required to be on an accessible route?
1104.3.1 Exception
In structures without elevator service located in flood hazard areas, Type A and Type B units are not required where the difference in elevation between the minimum required floor elevation at the primary entrances and arrival points within 50 feet exceeds what amount?
1108.7.5
In general, horizontal grab bars must be installed within what height range above the floor, measured to the top of the gripping surface?
609.4.1
What is the maximum depth that toe clearance is permitted to extend under an element?
306.2.2
In new buildings, platform lifts with doors on adjacent sides must provide what minimum clear floor dimensions?
410.5.2.1
For bottle filling stations, what types of clear floor space approach are permitted?
602.4.1
Accessible unit mirrors above lavatories complying with Section 606 must have the bottom edge of the reflecting surface located what maximum height above the floor?
1102.11.2.2
If a clear floor space is positioned for a forward approach at a cooktop, what protection must be provided for the underside of the cooktop?
804.5.4.2
In a building equipped throughout with an automatic sprinkler system, the elevator required by Section 1009.2.1 is NOT required as part of the accessible means of egress if the floor is located at or above the level of exit discharge and provided with which component?
1009.2.1, Exception 1
Under what condition must an exterior area for assisted rescue (EAAR) be provided on the exterior landing?
1009.7
Alternatives to the designs, products, or technologies prescribed by this standard are permitted provided they result in equivalent or greater accessibility AND:
104.1
A wheelchair space shall not overlap the required width of an aisle, except that in new buildings, the depth of a wheelchair space shall be permitted to overlap the required aisle width by what maximum dimension?
802.5.1
For historic buildings with multiple levels, an accessible route must be provided from an accessible entrance to which public spaces?
IEBC 306.7.18.2
An accessible route shall not be required between site arrival points and the building or facility entrance if the only means of access is a vehicular way not providing for pedestrian access, EXCEPT in which case?
1104.1
For a standard accessible water closet, grab bars shall be provided on which two walls?
604.5
If tiered seating in assembly areas includes dining surfaces or work surfaces, wheelchair spaces shall comply with Sections 802.6, 802.7, 802.9, 802.10, and which other section?
802.1
What is the maximum permitted height for thresholds at exterior sliding doors in Type B units?
1104.5.2.2 Exception
At least one toilet and bathing facility in an Accessible unit must comply with Section 1102.11.2. How must the required accessible lavatory, water closet, and bathtub or shower be configured?
1102.11.2
At least 5 percent, but not fewer than 1, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges must be designed so that what can enter and exit?
1006.2.4
What is the minimum required length for the accessible work surface in an accessible kitchen?
804.3
What is the minimum required width for the clearance around an accessible water closet, measured perpendicular from the sidewall?
604.3.1
For Accessible Units, ramps must comply with which section?
1102.6
If an addition affects the accessibility to, or contains an area of, a primary function, it shall comply with the requirements in which section?
IEBC 306.6
Accessible means of egress required by Chapter 10 of the International Building Code are required to be added in existing facilities undergoing alterations. (True/False)
IEBC 306.7.2
Power-operated swinging doors serving a LULA elevator must remain open for what minimum duration when activated?
408.3.2.2
What is the maximum outside diameter permitted for a handrail with a circular cross section?
505.7.1
A sign containing raised characters and braille must have a clear floor area centered on the raised characters of what minimum dimension?
703.3.11
Objects on multiple posts or pylons, where the clear distance between posts is greater than 12 inches (305 mm), must have the lowest edge at what height range?
307.3
What is the minimum required space between the grab bar gripping surface and the adjacent wall?
609.3
In Type B units, for the maneuvering clearance at swinging doors for the front approach direction on the push side, what is the minimum required dimension perpendicular to the door?
1104.5.1 Exception
What is the minimum required width for an access aisle serving car and van parking spaces?
502.4.2
Where clocks are provided for public use and installed overhead, the numerals and digits must be visual characters complying with which section?
805.8
In Type B units utilizing Option A, where a vanity overlaps the required water closet clearance, what is the maximum permissible depth of the vanity, measured perpendicular from the rear wall?
1104.11.3.1.2.2.4
For on-street perpendicular or angled accessible parking spaces, what is the minimum required width for the access aisle?
502.9.2
Benches primarily for children’s use are permitted to have a seat height within what range above the floor?
903.6 Ex.
In an elevator, the raised character and braille floor designations must be placed immediately to the left of the control button, and the number zero (0) shall designate which floor?
407.4.7.1.2, 407.4.7.1.3
The minimum width required for both toe clearance and knee clearance is:
306.2.5, 306.3.5
If a clear floor space is confined in an alcove and positioned for a forward approach, the alcove must be 36 inches (915 mm) minimum in width where the depth exceeds what dimension?
305.7.2
In existing buildings and facilities, what is the minimum required length and width for a clear floor space?
305.3.2
For an LULA (Limited-Use/Limited-Application) elevator utilizing swinging hoistway doors, what operation is required, and which standard must they comply with?
408.3.2.1
Where Accessible, Type A or Type B units are being altered or added within an existing building, the number of required units shall be determined in accordance with which sections?
IEBC 306.7.11
Incremental volume controls on volume-controlled telephones shall provide at least one intermediate step of gain of what minimum value?
704.3
In Type A kitchen work areas, what is the minimum required clearance between opposing base cabinets, countertops, appliances, or walls?
1103.12.1.1
For dining surfaces and work surfaces primarily for children’s use, what minimum knee clearance height above the floor is permitted as an exception to Section 306?
902.5.1 Ex.
In interior locations, detectable warning surfaces must differ from adjoining walking surfaces in resiliency or what other characteristic?
705.4
Handrails shall be continuous within the full length of each stair flight or ramp run. Which type of handrail must be continuous between flights or runs?
505.3
The audio output from an internal speaker of an Infrared Audible Sign Receiver shall be what minimum sound level at 18 inches (455 mm)?
703.8.3.3
Altered areas limited to which type of unit are exempt from the requirement to upgrade the accessible route, toilet facilities, and drinking fountains serving an area of primary function?
IEBC 306.7.1, Exception 5
Where a parallel approach is provided to a wheelchair accessible public telephone, what is the maximum distance permitted from the edge of the telephone enclosure to the face of the telephone?
704.2.1.1
The height of the pool lift seat, when in the raised position, shall be designed to allow a stop within what deck-to-seat height range?
1009.2.4
On a golf hole with three or more teeing grounds, which teeing ground, in addition to the second required teeing ground, must be designed for golf car entry and exit?
1006.2.1
If a sales and service counter utilizes a forward approach, what is the minimum required length of the accessible portion of the counter surface?
904.3.3
For a Type B refrigerator/freezer where the clear floor space is positioned for a parallel approach, what is the maximum offset permitted from the centerline of the appliance to the centerline of the clear floor space?
1104.12.2.5.3
Accessible vehicle spaces serving electrical vehicle charging stations must have an adjoining access aisle that is what minimum width?
1107.2.2
Where spas, cold baths, or hot tubs are clustered at a single location, at least 5 percent, but not less than one of each type in each cluster, shall be accessible. Which specific recreational features are included in this clustering requirement?
1111.4.14
What is the maximum reach height permitted for hand operated controls on hand dryers serving lavatories, where the reach depth is 5 inches (125 mm)?
603.6
In motion picture viewing spaces, wheelchair space locations shall be located within the area of an auditorium in which the vertical viewing angles, as measured to the top of the screen, are from the 40th percentile to what maximum percentile of vertical viewing angles for all seats?
802.10.4.2
In a Type A unit, if a bottom-hinged oven door is provided, where must a countertop be positioned?
1103.12.5.5.3
On accessible routes located on the playing surfaces of miniature golf holes, what is the maximum slope permitted for a curb where the route intersects the playing surface?
1007.2
For a required accessible means of egress, which component is explicitly NOT listed as a component of the continuous accessible route?
1009.2
In Type A kitchens, where a side-hinged door oven is provided, where must a countertop be positioned?
1103.12.5.5.2
Displays and information on accessible parking meters and pay stations must be visible from a point located what maximum height above the center of the clear space in front of the station?
502.10.2
If an elevator car has a centered door location, what is the minimum required door clear opening width?
407.4.1
In detention and correctional facilities, signs identifying permanent rooms and spaces are not required to comply with visual characters, raised characters, and braille provisions if they are located where?
1112.6
If spectators in front of the wheelchair space locations are expected to stand at their seats for purposes of viewing events, the line of sight must comply with which section?
802.9
In structures intended to be occupied as a residence, how many dwelling units or sleeping units must be present in a single structure before every unit is required to be a Type B unit?
1108.6.2.2.2
In Type B units, for an accessible route making a 180-degree turn around an object less than 48 inches (1220 mm) wide, what is the minimum clear width required during the turn?
1104.4.1 Exception
What is prohibited under the exposed portions of dining surfaces and work surfaces?
902.3
Walking surfaces that are part of an accessible route within Accessible units shall comply with which section of the code?
1102.4
In Type B units using Option A, where a forward approach is provided to the water closet, what is the minimum required clearance depth from the rear wall?
1104.11.3.1.2.2.3
The accessible route from any separate-sex toilet room to a family or assisted-use toilet room shall not exceed what maximum travel distance?
1110.2.1.4
What is the minimum and maximum height range for amusement ride transfer devices and seats designed for transfer, measured from the surface of the load and unload area?
1002.5.2
For an assembly area with 5,001 seats, what is the minimum required number of wheelchair space locations?
802.10, Table 802.10
Where accessible routes pass through parking facilities, what measure must be taken unless an exception applies?
507.1
In general, doors shall not swing into the clear floor space or clearance for any fixture in a toilet or bathing room. Which situation is NOT an exception to this rule?
603.2.2
For a standard accessible lavatory, what type of approach must be provided for the clear floor space?
606.2
Grab bars with a circular cross section shall have an outside diameter within what size range?
609.2.1
What protection must be provided for water supply and drainpipes exposed beneath lavatories and sinks?
606.6
In Accessible units, what compliance requirement applies to user controls for security or intercom systems?
1102.9
In new buildings (T-shaped turning space, Option 1), the required T-space must fit within an area that is 68 inches wide and what minimum depth?
304.3.2.1
Braille provided on elevator car controls shall be separated what minimum distance from the corresponding raised characters or symbols?
703.4.4
In Type B units utilizing Option A, a bathtub with a parallel approach requires a clearance of 60 inches minimum in length and 30 inches minimum in width. What fixture is specifically permitted to be located in this clearance area?
1104.11.3.1.3.1
For gangways, floating piers, and transition plates that are part of accessible routes, how shall the cross slope specified in Sections 403.3 and 405.3 be measured?
1003.2.1
The tops of standard accessible dining surfaces and work surfaces shall be located within what height range above the floor?
902.4
Where the bottom grade break of a perpendicular curb ramp is behind the back of curb by more than 60 inches (1525 mm), where shall the detectable warning surface be placed?
705.7.1
In new buildings, what is the maximum interval at which passing spaces must be provided if the accessible route has a clear width less than 60 inches (1525 mm)?
403.5.4.1
In Accessible units, if toilet and bathing facilities are not required to comply with Section 1102.11.2, reinforcement for future installation of grab bars and shower seats shall be provided in accordance with which section?
1102.11.1
The signal-to-noise ratio for internally generated noise in assistive listening systems shall be what minimum value?
706.6
On the push side, door surfaces must be smooth for the full width of the door or gate and extend up from the floor for a minimum of what distance?
404.2.9
What is the maximum height permitted for the checkout counter surface above the floor?
904.4.2
Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with the variable message sign requirements of ICC A117.1, unless what is provided?
1112.5.2
At least what minimum percentage of care recipient and visitor parking spaces provided to serve hospital outpatient facilities shall be accessible?
1106.4
Self-service shelves and dispensing devices in food service lines shall comply with which section governing reach ranges?
904.5.1
Parking spaces and access aisles must have floor surfaces that comply with Section 302 and have surface slopes not steeper than what ratio?
502.5
Accessible dining surfaces and work surfaces primarily for children ages 5 and younger are exempt from complying with Section 902.5, provided they have a clear floor space positioned for which approach?
902.5 Ex.
The top of handrail gripping surfaces on ramps connecting elevated play components shall be what maximum height above the ramp surface?
1008.4.1.2.3.2
Stairways that are part of the means of egress for an exterior area for assisted rescue must provide a minimum clear width between handrails of:
1009.7.4
Per Figure 105.4, what does a dashed line of short dashes represent?
105.4
What must the administrative authority provide to specify the extent to which the technical criteria of this standard apply?
201
If an alternative accessible bathing room is provided due to technical infeasibility, it must be located:
IEBC 306.7.13
Where receipts are provided by an ATM, the speech output devices must provide audible information for which items?
707.8.2
What is the maximum operating force permitted for a horizontal or vertical sliding operable window?
506.2
In new buildings and facilities, what is the minimum required width for an access aisle serving a passenger loading zone vehicle pull-up space?
503.3.2.1
In Type A units, if an accessible work surface is adjustable, what is the maximum height above the floor permitted?
1103.12.3.2 Exception
If vanity countertop space is provided in Accessible units, what measurement criteria must it meet relative to the lavatory?
1102.11.2.1
Where an alteration affects the accessibility to, or contains an area of, primary function, which element is required to be made accessible, in addition to the route to the primary function area?
IEBC 306.7.1
In units with accessible communication features, if unit smoke detection is provided, it must include what type of notification complying with NFPA 72?
1106.2
Spaces and elements within employee work areas are required to comply with Sections 907.5.2.3.1, 1009, 1104.3.1, and what additional requirement?
1103.2.2
In a new building, if the clear width of an interior accessible route is reduced to 32 inches (815 mm) minimum, what is the maximum length of this reduced-width segment?
403.5.1
In new buildings, where an accessible route makes a 180-degree turn around an object less than 52 inches wide, what is the minimum required width during the turn if the approaching and leaving widths are 36 inches minimum?
403.5.2.1
Type B dwelling or sleeping units are NOT required in existing buildings undergoing alterations where the work area is what percentage or less of the aggregate area of the building?
IEBC 306.7.4
What is the minimum clear opening required for doorways in Type C (Visitable) Units?
1105.5.3.1
What is the minimum length required for a transfer wall?
1009.4.3
In historic buildings where bathing rooms are provided, what is the minimum required accessible facility?
IEBC 306.7.18.5
Projections into the clear opening width of a doorway between 34 inches and 80 inches above the floor shall not exceed what maximum dimension?
404.2.2
For a forward approach counter, what is the maximum height permitted for the accessible counter surface above the floor?
904.3.3
An accessible route is not required to connect stories, mezzanines, and occupiable roofs that have an aggregate area of not more than 3,000 square feet and are located above and below accessible levels. This exception does NOT apply to which occupancy?
1104.4
An area of refuge is NOT required at an elevator that is part of an accessible means of egress if the elevator is serving which specific facility type?
1009.4.2, Exception 1
In existing buildings, a T-shaped turning space shall fit within what minimum square dimension?
304.3.2.2
What is the minimum required clear space that must be provided beyond the bottom grade break of a curb ramp, located within the pedestrian street crossing and outside the parallel vehicle travel lane?
406.5.5
According to Table 1109.2.2.1, an assembly area with 3,000 fixed seats requires how many minimum required wheelchair spaces?
1109.2.2.1, Table 1109.2.2.1