“Study at your own pace with randomized flashcards and instant feedback — click the green ✓ to remove a card you’ve mastered, the red ✗ to keep it for more review, and tap any card to reveal the answer with its code section.”

Welcome this is Flashcards

Where seating provides lines of sight over heads, spectators in a wheelchair space must be afforded lines of sight over the heads of seated individuals in which row?

The first row in front of the wheelchair space location

802.9.1.1

Knee and toe clearance complying with Section 306 shall be provided beneath which accessible elements?

Dining surfaces and work surfaces

902.2

In existing buildings, T-shaped turning spaces are permitted to include knee and toe clearance only at which locations?

The end of either the base or one arm

304.3.2.2.1

Raised characters shall be duplicated in what type of braille?

Contracted (Grade 2) braille

703.3.1, 703.4.1

Where a visitor communication system is provided at a site, building, or floor entrance (other than the unit door), what specific capability must the public or common-use system interface support in addition to voice communication with the unit interface?

TTY communication

1106.6.1

What is the maximum height above the floor permitted for the front of a sink in a Type A unit kitchen, measured to the higher of the rim or counter surface?

34 inches (865 mm)

1103.12.4.2

In new buildings, what is the minimum required length of clearance adjacent to the open face of a transfer-type shower compartment?

52 inches (1320 mm)

608.2.1.2.1

The top of a standard bench seat shall be located within what height range above the floor?

17 inches (430 mm) minimum and 19 inches (485 mm) maximum

903.6

When amusement rides are at rest in the load and unload position, the vertical difference between the ride floor and load/unload area floor shall be within plus or minus:

5/8 inch (16 mm)

1002.4.3

In a Type A unit with a side-hinged door oven, the adjacent countertop must be positioned on which side of the door?

The latch side

1103.12.5.5.2

In Group R-2, R-3, and R-4 occupancies where recreational facilities serve a single building containing Type A or Type B units, what minimum percentage of each type of recreational facility shall be accessible?

25 percent

1111.2.2

Where an escalator or stairway is added where none existed previously and major structural modifications are necessary for installation, what accessible element is required between the levels served?

An accessible route complying with Section 1104.4 of the International Building Code.

IEBC 306.7.10

If wall space does not permit a 36-inch rear grab bar due to a recessed fixture, what minimum length is permitted for the centered rear grab bar?

24 inches (610 mm)

604.5.2

Automatic teller machines (ATMs) required to be accessible must provide what in front of the machine?

A clear floor space

707.2

All dimensions are subject to conventional industry tolerances EXCEPT where the requirement is defined as:

A range with stated minimum and maximum end points

105.3

If vanity countertop space is provided in dwelling or sleeping units not required to be Accessible units within the same facility, what specific requirement applies to the vanity countertop space in the Accessible units?

Equivalent vanity countertop space, in terms of size and proximity to the lavatory, shall also be provided

1102.11.2.1

In Type C (Visitable) Units, where are operable parts of lighting controls and receptacle outlets required to be located?

15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the floor

1105.8

In Type C (Visitable) Units, where a food preparation area is provided on the entrance level, it must include a sink, a cooking appliance, and what other fixture?

A refrigerator

1105.7

Openings providing entry to wheelchair spaces on amusement rides shall provide a clear width of what minimum dimension?

32 inches (815 mm)

1002.4.5

What is the maximum height permitted for the spout outlet of a drinking fountain primarily for children’s use?

30 inches (760 mm)

602.2.3

Operable parts are required to be operable with one hand and shall not require tight grasping, pinching, or what other action?

Twisting of the wrist

309.4

An assembly area with a total seating capacity of 501 to 1000 seats requires a minimum of how many wheelchair space locations?

3

802.10, Table 802.10

If a building fire alarm system is provided, where must the system wiring be extended within a unit required to have communication features?

To a point within the unit in the vicinity of the unit smoke detection system

1106.3

What is the minimum clearance required between the handrail gripping surface and adjacent surfaces?

1 1/2 inches (38 mm)

505.5

What instructions must be provided in braille on an ATM?

Instructions for initiating the speech mode

707.1

In new construction, when a circular turning space includes an overlap of knee and toe clearance, what is the maximum permitted depth of this overlap?

10 inches (255 mm)

304.3.1.1.1

A companion seat is required for each wheelchair space where the interior width of the amusement ride is greater than:

53 inches (1345 mm)

1002.4.7

Where a side-hinged door oven is provided, the adjacent accessible work surface must be positioned on which side of the oven door?

Latch side

804.5.5.2

In courtrooms, where each area that is raised or depressed is provided, what is the required feature?

A turning space

807.2

Openings in floor surfaces are limited in size such that they do not permit the passage of a sphere greater than what diameter?

1/2 inch (13 mm)

302.3

In existing buildings and facilities, what is the minimum depth required for a wheelchair space entered from the front or rear?

48 inches (1220 mm)

802.4.2

At least what percentage, but not less than one, of the cubicles in visiting areas of judicial facilities shall be accessible on both the visitor and detainee sides?

5 percent

1110.15.1

Which rooms are explicitly NOT considered employee work areas?

Corridors, toilet rooms, kitchenettes and break rooms

107.5

Public telephones required to have volume control must provide a receiver volume control that provides a gain adjustable up to what minimum gain?

20 dB

704.3

Two-way communication systems required by Section 1009.8.1 must include which combination of signals?

Audible and visible signals

1009.8.1

Where provided in accessible dressing, fitting, or locker rooms, a shelf shall be located within what height range above the floor?

40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum

803.5

In a Type C (Visitable) Unit, a toilet room or bathroom is not required on an entrance level if the habitable space provided on that level is less than what area?

120 square feet (11.2 m2)

1105.4 Exception

What minimum illuminance level is required at the center of the sign language interpreter station floor, measured at a height of 48 inches above the floor, while signing is underway?

10 footcandles (108 lux)

802.11.4

Between 9 inches and 27 inches above the floor, the knee clearance depth is permitted to be reduced at what rate?

1 inch in depth for each 6 inches in height

306.3.4

In an area of refuge, access to any of the required wheelchair spaces shall not be obstructed by more than how many adjoining wheelchair spaces?

One

1009.6.3

In Type C (Visitable) Units, which fixture is mandatory in the food preparation area (if provided)?

A sink

1105.7

In Type A units, where the lavatory overlaps the water closet clearance, reinforcement shall be provided at the rear wall for a grab bar of what minimum length?

24 inches (610 mm)

1103.11.1 Exception

For classrooms with volumes up to and including 10,000 cubic feet (285 m3), the reverberation time (T60) for the specified octave frequency bands shall not exceed what time?

0.6 seconds

808.2.1

Ramp runs with a rise greater than what dimension must have handrails complying with Section 505?

6 inches (150 mm)

405.8

Where an altered entrance is not required to be accessible because the facility already has an accessible entrance, what must be provided?

Signs complying with Section 1112 of the International Building Code.

IEBC 306.7.5

Where doors lead to an area of refuge or exterior area for assisted rescue and reentry to the floor is possible, door maneuvering clearances shall be provided on which side(s) of the door?

Both sides of the door

1009.2.2

Where mirrors are located above lavatories complying with Section 606, the bottom edge of the reflecting surface must be mounted at what maximum height above the floor?

40 inches (1015 mm)

603.3

In Group I-1, Condition 2 occupancies, what is the minimum percentage of dwelling units and sleeping units that shall be Accessible units?

10 percent

1108.5.1.2

In private residence elevators within Type B units, what are the minimum required clear floor length and clear floor width inside the elevator car?

48 inches (1220 mm) minimum length and 36 inches (760 mm) minimum width

1104.7 Exception

In a sprinklered building, the elevator required by Section 1009.2.1 is NOT required as part of the accessible means of egress if the floor or occupiable roof is provided with a ramp conforming to the provisions of which section?

Section 1012

1009.2.1, Exception 2

In Accessible units, what specific type of bed frame must at least one bed be provided with?

Open bed frame

1102.15.2

In a standard adult wheelchair accessible toilet compartment, toe clearance is required on the front partition and at least one side partition, extending 8 inches beyond the face of the partition and 12 inches minimum above the floor, unless the compartment exceeds what depth for a floor-mounted water closet?

67 inches (1700 mm)

604.9.5.1

In units with accessible communication features, if visible notification appliances are provided for a building fire alarm system, when must they be activated?

Upon activation of the building fire alarm in the portion of the building containing the unit

1106.4.2

In play areas less than 1000 square feet, the clear width of accessible routes is permitted to be reduced to 44 inches (1120 mm) minimum, provided a turning space is present where the reduced route exceeds what maximum length?

30 feet (9145 mm)

1008.4.1.1.1

A noncircular handrail cross section shall have a maximum perimeter dimension of:

6 1/4 inches (160 mm)

505.7.2

Which of the following spaces is defined as Habitable?

A space in a building for cooking

107.5

An area of refuge must be separated from the remainder of the story by a smoke barrier complying with Section 709 or which other means of egress component?

A horizontal exit complying with Section 1026

1009.6.4

In Accessible units, where are operable windows not required to comply with the general requirements of Section 506.1?

Kitchens and bathrooms

1102.13 Exceptions

For water closets designed for assisted toileting, the clearance around the water closet shall be not less than what minimum width, measured perpendicularly from the side of the clearance not less than 24 inches from the centerline?

66 inches (1675 mm)

1110.2.2.2.1

What is the minimum depth required for a wheelchair accessible toilet compartment with a wall-hung water closet?

56 inches (1420 mm)

604.9.2.1

What is the required frequency modulation for basic speech messages provided by Remote Infrared Audible Sign (RIAS) Transmitters?

25 kHz

703.8.3.1

In Type A units, if a lavatory measuring 24 inches (610 mm) maximum in depth overlaps the water closet clearance, what is the minimum distance required from the centerline of the water closet to the side edge of the lavatory?

18 inches (455 mm) minimum

1103.11.2.4.4 Exception

Where it is technically infeasible to alter existing bathing rooms to be accessible, what alternative accessible facility is permitted on the same floor and in the same area?

One accessible single-user bathing room or one accessible family or assisted-use bathing room.

IEBC 306.7.13

Sites, facilities, and elements required to be accessible by the adopted scoping provisions shall comply with the applicable provisions of which chapters?

Chapters 3 through 10

102.2

Where reinforcement for swing-up grab bars is provided at a Type B unit water closet, the reinforcement must accommodate a grab bar that is centered what distance from the centerline of the water closet?

15 3/4 inches (400 mm)

1104.11.1.1

Where security glazing is used at counters, a method to facilitate what must be provided?

Voice communication

904.6

In addition to direction for use of the communication system, instructions posted in an area of refuge must include information on the planned availability of assistance in the use of stairs or supervised operation of elevators and how to do what?

Summon such assistance

1009.11

Low resolution VMS signs installed greater than 120 inches above the floor require a minimum character height of 4 inches, which must be increased by 1/5 inch per foot of viewing distance above what minimum distance?

20 feet (6095 mm)

703.7.4, Table 703.7.4

What case must be used for raised characters?

Uppercase

703.3.3

What type of clear floor space approach is required at a standard adult drinking fountain designed for persons using wheelchairs?

Forward approach

602.2.1

For closed-circuit communication systems in units required to have communication features, what specific element must the unit system interface include?

A telephone jack capable of supporting voice and TTY communication

1106.7

The number of accessible elements following an alteration or addition need not exceed the quantity required for:

New construction at the time of alteration or addition.

IEBC 306.2.1

When are separate-sex accessible dressing, fitting, or locker rooms required where technical infeasibility is cited?

Where separate-sex facilities are provided.

IEBC 306.7.16

For water closets designed for assisted toileting, the centerline of the water closet shall be not less than 24 inches (610 mm) and not greater than what distance from one side of the required clearance?

26 inches (660 mm)

1110.2.2.1

To ensure a nonglare finish, the glare from visual characters and their background shall not exceed how many gloss units (gu)?

19 gloss units (gu)

703.2.10.1

Doors, gates, or adjacent sidelites containing glazing panels that permit viewing must have the bottom of at least one panel on the door, gate, or sidelite no more than what height above the floor?

43 inches (1090 mm)

404.2.10

An accessible route must consist of one or more of several components, including walking surfaces, doors, ramps, and which of the following?

Curb ramps excluding the flared sides

402.2

Transparent security glazing is permitted to be installed above the maximum height established for vertical barriers at service windows/counters.

True

904.3.1 Ex.

Accessible parking spaces required by Section 1106.2 must be identified by the International Symbol of Accessibility, except where the total number of parking spaces provided is what amount or less?

4

1112.1

In Type B units, if an accessible route making a 180-degree turn has a clear width of 60 inches (1525 mm) minimum during the turn, what is the minimum clear width required approaching and leaving the turn?

36 inches (915 mm)

1104.4.1 Exception

Jury boxes and witness stands must provide a clear floor space, except in alterations where wheelchair spaces are permitted to be located outside the defined area if what prevents placement within the area?

Ramps or platform lifts restrict or project into the means of egress

807.3 Ex.

For Accessible routes within Type A units, an accessible route is not required to which part of the unit?

Unfinished attics and unfinished basements

1103.3.1 Exception

Where Accessible units include elevators within the unit, those elevators must comply with Section 407, 408, 409, or which other section of the code?

Section 409

1102.7

What is the raised symbol required on the function key surface for “Enter or Proceed”?

CIRCLE (O)

707.6.1, Table 707.6.1

In Type C (Visitable) Units, the unit entrance must be on a circulation path from a public street or sidewalk, a dwelling unit driveway, or what other location?

A garage

1105.2

The requirements for Type A dwelling or sleeping units (Group R-2) apply only to the quantity of units being altered or added where more than how many units are being altered or added?

20

IEBC 306.7.11.2

If a sales and service counter utilizes a parallel approach, what is the minimum required length of the accessible portion of the counter surface?

36 inches (915 mm)

904.3.2

Where induction hearing loop systems are provided, they must comply with which IEC standard?

IEC-60118-4

706.3

A required accessible floor located four or more stories above or below a level of exit discharge must have at least one accessible means of egress component including which of the following?

An elevator complying with Section 1009.4

1009.2.1

The maximum travel distance from any accessible space to an area of refuge shall not exceed what limitation?

The exit access travel distance permitted for the occupancy

1009.6.1

In new buildings and facilities, what is the minimum diameter required for a circular turning space?

67 inches (1700 mm)

304.3.1.1

Spacing between individual raised characters shall be what minimum distance measured at the top surface of the characters?

1/8 inch (3.2 mm)

703.3.8

What is the prohibited use for visible notification appliances used to indicate unit smoke detection or building fire alarm activation in units with communication features?

Shall not be used for any other purpose within the unit

1106.4.4

Where only one accessible route is provided, it shall not pass through which of the following spaces?

Kitchens, storage rooms, restrooms, or closets

1104.5

What is the minimum depth required for a wheelchair accessible toilet compartment with a floor-mounted water closet?

59 inches (1500 mm)

604.9.2.1

The changing surface height of an adult changing station must be adjustable from 17 inches minimum to what maximum height above the floor?

38 inches (965 mm)

613.4.3

What are the minimum required width and depth measurements for the clearance around a water closet in a Type A unit?

60 inches (1525 mm) minimum width and 56 inches (1420 mm) minimum depth

1103.11.2.4.2; 1103.11.2.4.3

For a Type B accessible route making a 90-degree turn, what is the minimum clear width required approaching the turn and leaving the turn?

36 inches (915 mm)

1104.4.1 Exception

At least what percentage of holes on miniature golf courses shall be accessible?

50 percent

1111.4.12.1

Operable parts of storage facilities shall comply with which section?

Section 309

905.4

For a parallel approach counter, the top of the accessible counter surface shall be within what height range above the floor?

26 inches (660 mm) minimum to 36 inches (915 mm) maximum

904.3.2

At pedestrian at-grade rail crossings not located within a street or highway, the edge of the detectable warning surface nearest the rail crossing shall be placed within what distance range from the centerline of the nearest rail?

6 feet (1830 mm) minimum and 15 feet (4680 mm) maximum

705.7.5

In Type A units, what elements must at least one accessible route connect?

All spaces and elements that are a part of the unit

1103.3.1

If a closed-circuit communication system is provided for a unit with communication features, what element must the unit system interface include?

A telephone jack capable of supporting voice and TTY communication

1106.7

In Type A units, where is the primary entrance not permitted to be located, unless it is the only entrance?

To a bedroom

1103.2

According to Table 1111.4.9.1, what is the minimum number of accessible boat slips required for a facility providing 120 total boat slips?

4

1111.4.9.1, Table 1111.4.9.1

For a standard accessible water closet, the centerline must be located within what range from the side wall or partition?

16 inches (405 mm) minimum and 18 inches (455 mm) maximum

604.2

In alterations, an existing threshold is permitted to be 3/4 inch maximum in height, provided that the height exceeding 1/4 inch has a beveled edge with a maximum slope of:

1:2

404.2.4

When elements of an existing elevator are altered, which other elevators must also have those elements altered?

Elevators programmed to respond to the same hall call control as the altered elevator.

IEBC 306.7.7

In new buildings, what is the minimum required clear floor area dimensions for a Private Residence Elevator?

36 inches (915 mm) wide and 52 inches (1320 mm) deep

409.4.1.1

In new buildings and facilities, what is the minimum depth required for a wheelchair space entered from the front or rear?

52 inches (1320 mm)

802.4.1

What is the required width range for an ambulatory accessible toilet compartment?

35 inches (890 mm) minimum and 37 inches (940 mm) maximum

604.10.2

Carpet installed on an accessible floor surface shall have a maximum pile height of:

1/2 inch (13 mm)

302.2

Boat slips and boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) minimum in width that extends for what distance?

The full length of the boat slips or boarding piers

1003.3.1

Where a swimming pool has less than 300 linear feet of swimming pool wall, what is the maximum number of accessible means of entry required?

No more than one

1009.1.1

For front loading washing machines and clothes dryers, the bottom of the opening to the laundry compartment must be located within what height range above the floor?

15 inches (380 mm) minimum and 36 inches (915 mm) maximum

611.4

For an accessible drinking fountain, the spout must be located what minimum distance from the vertical support?

15 inches (380 mm)

602.2.4

Accessible parking spaces must be located on the shortest accessible route of travel from adjacent parking to where?

An accessible building entrance

1106.7

Each required area of refuge shall be sized to accommodate one wheelchair space of 30 inches by 52 inches (762 mm by 1320 mm) for each increment of the occupant load served by the area of refuge. What is that occupant load increment?

200 occupants

1009.6.3

What sign identification is required at each door providing access to an area of refuge from an adjacent floor area?

"AREA OF REFUGE"

1009.9

On accessible routes serving recreational boating facilities, where the total length of a gangway or series of gangways is 80 feet (24 m) minimum, gangways are NOT required to comply with which section?

Section 405.2 (running slope)

1003.2.1

How many companion seats must be provided for each wheelchair space required in assembly areas?

At least one

1109.2.3

For historic structures, alternative accessibility requirements are permitted only when full compliance would threaten or destroy the historic significance, as determined by whom?

The authority having jurisdiction.

IEBC 306.7.18

In assembly and mercantile occupancies, where additional toilet fixtures are added, which accessible facility must be provided?

Not fewer than one accessible family or assisted-use toilet room.

IEBC 306.7.14

In new buildings and facilities, what is the minimum depth required for a wheelchair space that is only entered from the side?

60 inches (1525 mm)

802.4.1

What title shall this document be known as?

The standard for Accessible and Usable Buildings and Facilities

101.1

Which sales or service counter type is explicitly exempt from complying with Section 904?

Drive-up only sales or service counters and windows

904.1 Ex.

In new buildings, one option for a 90-degree turn permits both legs to be 36 inches minimum in width, provided the interior corners are chamfered for a minimum of what dimension along both walls?

8 inches (205 mm)

403.5.3.1

For low resolution VMS signs mounted 40 to 70 inches above the floor, and a viewing distance of less than 10 feet, what is the minimum character height?

2 inches (51 mm)

703.7.4, Table 703.7.4

Objects located 9 inches minimum and 27 inches maximum above the floor of the wheelchair space are permitted to protrude what maximum distance along the front of the wheelchair space?

6 inches (150 mm)

1002.4.4.3

In Type B units utilizing Option A, where a lavatory complying with Section 606 is permitted in the clearance of a parallel approach bathtub, what is the minimum length required for the remaining clearance in front of the bathtub?

60 inches (1525 mm)

1104.11.3.1.3.1

When required by Section 1009.1 of the International Building Code, how many accessible means of egress must be provided from an addition?

Not fewer than one.

IEBC 306.6.1

In Type A units, all rooms served by an accessible route must provide what feature?

A turning space

1103.3.2

In units with accessible communication features, is it permitted to use the same visible notification appliance to signal both unit smoke detection and building fire alarm activation?

Yes, the same visible notification appliances are permitted

1106.4.3

When utilizing Option A (Section 1104.11.3.1) for water closets in Type B units, the centerline of the water closet shall be located what minimum and maximum distance from one side of the required clearance?

16 inches (405 mm) minimum and 18 inches (455 mm) maximum

1104.11.3.1.2.1

Where a mirror is located within the same toilet or bathing room but not over a lavatory, and is provided as an exception to the 40-inch rule, the bottom edge must be mounted at what maximum height?

35 inches (890 mm)

603.3

In historic structures, which accessible element required by Chapter 10 of the International Building Code is specifically noted as not being required?

Accessible means of egress.

IEBC 306.7.18, Exception 1

An accessible route shall be provided to at least what percentage, but not less than one, of each type of bowling lane?

5 percent

1111.4.3

In a Type A unit kitchen, where a clear floor space is positioned for a forward approach to a cooktop, what required clearance must be provided beneath the cooktop?

Knee and toe clearance complying with Section 306

1103.12.5.4.2

In the raised position, the centerline of the pool lift seat shall be located what minimum distance from the edge of the pool?

16 inches (405 mm)

1009.2.2

If automatic, motion sensor-type lighting switches are used to achieve the required illumination level for stairs, what is the minimum duration the illumination timers must be set for?

15 minutes

504.9.1

In new construction, elevator hall call buttons and keypads must be located within one of the reach ranges specified in what section?

Section 308

407.2.1.1

In Accessible units, mirrors above lavatories required to comply with Section 606 shall have the bottom edge of the reflecting surface located no more than how many inches above the floor?

40 inches (1015 mm)

1102.11.2.2

For a manual swinging door in a new building, approached from the front (push side) and provided with both a closer and a latch, what is the minimum clearance required parallel to the doorway (beyond the latch side)?

12 inches (305 mm)

404.2.3.2

What is the maximum cross slope permitted for a walking surface that is part of an accessible route?

1:48

403.3

In Type A units, what is the required height range for the top of the water closet seat above the floor?

15 inches (380 mm) minimum and 19 inches (485 mm) maximum

1103.11.2.4.5

What is the maximum water temperature permitted to be delivered by bathtubs and showers?

120°F (49°C)

607.8, 608.8

Which chapter’s provisions apply to general site and building elements when those elements are required to be accessible by the administrative authority’s scoping provisions?

Chapter 5

501.1

Platform lifts shall not be attendant operated and must provide what type of operation for users?

Unassisted entry and exit from the lift

410.1

For Type A units, reinforcement for the future installation of grab bars at shower compartments is required for grab bars and shower seats complying with Sections 608.3, 608.2.1.3, 608.2.2.3 and which other section?

Section 608.2.3.2

1103.11.1

Which character styles are explicitly prohibited for visual characters?

Italic, oblique, script, or highly decorative forms

703.2.3

Which of the following elements is generally required to comply with Section 309 for operable parts in Accessible units?

Electrical switches

1102.9

In Type B units, reinforcement for two swing-up grab bars is permitted to be installed in lieu of reinforcement for rear wall and side wall grab bars at a water closet, provided what element is not available?

A side wall is not available for a 42-inch (1065 mm) grab bar complying with Section 604.5.1

1104.11.1 Exception

To comply with Section 605.2, a wall-hung urinal rim must be located at what maximum height above the floor?

17 inches (430 mm)

605.2

In nursing homes of Group I-2, Condition 1 occupancies, at least what percentage of each type of dwelling units and sleeping units shall be Accessible units?

50 percent

1108.5.2.1

In Saunas and Steam Rooms, a turning space shall be provided, and where seating is provided, at least one bench must comply with which section?

Section 903

612.2, 612.3

The height of the uppercase letter “I” for raised characters shall be within what minimum and maximum vertical range?

5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum

703.3.5

Where armrests are provided on seating in the immediate area of designated aisle seats, what type of armrests must be provided on the aisle side of the designated aisle seat?

Folding or retractable armrests

802.8.1

In Type A units, thresholds at exterior sliding doors are permitted to be how high, provided they are beveled with a slope not greater than 1:2?

3/4 inch (19 mm) maximum

1103.5 Exception

In new buildings, where an accessible route makes a 90-degree turn, what is the minimum width required for both legs of the turn if the width of each leg is maintained for 28 inches minimum from the inner corner?

40 inches (1015 mm)

403.5.3.1

Hand operated flush controls for water closets primarily for children’s use must be installed at what maximum height above the floor?

36 inches (915 mm)

604.11.6

For a top loading washing machine in a Type B unit, what type of approach must the clear floor space be positioned for?

Parallel approach

1104.10.1

Existing elements that are not altered are permitted to have an unobstructed high side reach of what maximum height?

54 inches (1370 mm)

308.3.1

Assembly areas utilized for viewing motion picture projections with 300 seats or less are exempt from which dispersion requirement?

Dispersion for Variety of Distances from the Event (802.10.2)

802.10.2 Ex. 2

In Type B units, clear floor spaces are required to be what minimum length and width?

48 inches (1220 mm) length and 30 inches (760 mm) width

1104.1.1

Bathtub enclosures shall not obstruct controls, faucets, shower and spray units, or obstruct what other critical function?

Transfer from wheelchairs onto bathtub seats or into bathtubs

607.7

What must the administrative authority provide to ensure compliance with this standard?

An appropriate review and approval process

203

Where a sign containing raised characters and braille is provided at double doors with one active leaf, where must the sign be located?

On the inactive leaf

703.3.11

Vertical and inclined platform (wheelchair) lifts installed in accordance with ASME A18.1 are permitted to be used as a component of which element?

An accessible route.

IEBC 306.7.9

In Type B units, what minimum length, measured from the wall to the end of the horizontal portion, must the reinforcement for a swing-up grab bar accommodate?

28 inches (710 mm)

1104.11.1.1

When required, knee clearance shall be a minimum of 11 inches (280 mm) in depth at 9 inches (230 mm) above the floor, and a minimum of what depth at 27 inches (685 mm) above the floor?

8 inches (205 mm)

306.3.3

In Accessible units, the clear floor space required at the bed must also serve what other function, complying with Section 906?

Wheelchair charging area

1102.15.4

For an obstructed high side reach where the reach depth exceeds 10 inches (255 mm) but is not more than 24 inches (610 mm), what is the maximum height allowed for the high side reach?

46 inches (1170 mm)

308.3.2

In Type C (Visitable) Units, if the food preparation area does not provide a cooktop or conventional range, what is the minimum permitted clearance between opposing cabinets/elements?

36 inches (915 mm)

1105.7 Exception

For an unobstructed side reach, the clear floor space must allow a parallel approach, and the edge of the clear floor space must be what maximum distance from the element being reached?

10 inches (255 mm)

308.3.1

What is the minimum dimension required for a ramp landing where the ramp changes direction between runs?

60 inches (1525 mm) by 60 inches (1525 mm)

405.7.4

For a self-service storage facility with a total of 300 spaces, what is the minimum number of required accessible spaces?

12

1109.3, Table 1109.3

Handrail brackets attached to the bottom surface are permitted to obstruct what maximum percentage of the handrail length?

20 percent

505.6

At least what percentage of all public entrances shall be accessible?

60 percent

1105.1

What is the minimum required clear width for the circulation path within a Type C (Visitable) Unit?

36 inches (915 mm)

1105.5.2.1

Which maneuvering clearance is explicitly NOT required in a toilet room or bathroom in Accessible units if that facility is not required to comply with Section 1102.11.2?

Maneuvering clearances required by Section 404.2.3 on the room side of the door

1102.5 Exception

Where a permanent wall is less than 10 feet behind a sign language interpreter station, it must serve as a backdrop and provide a monochromatic, low-luster finish up to what minimum height from the finish floor?

96 inches (2440 mm)

802.11.5

Knee and toe clearance is NOT required to extend beneath a drink surface provided that the depth of the drink surface does not exceed what maximum dimension?

12 inches (305 mm)

902.2 Ex. 1

The provisions of Sections 306.1 through 306.7.16 apply to which of the following activities in existing buildings?

All of the above (repair, alteration, change of occupancy, addition, or relocation).

IEBC 306.1

Elevator doors must remain fully open in response to a car call for what minimum duration?

3 seconds

407.3.5

The technical criteria in this standard are based on the body sizes and functional abilities of adults and, in those sections where specifically noted, which other group?

Children

103.1

Where a forward approach is provided to an accessible public telephone, the distance from the front edge of a counter within the enclosure to the face of the telephone shall be what maximum distance?

20 inches (510 mm)

704.2.1.2

For classrooms with volumes between 10,000 cubic feet and 20,000 cubic feet (566 m3), the reverberation time (T60) shall not exceed what time?

0.7 seconds

808.2.1

What must be provided under the accessible counter utilizing a forward approach?

Knee and toe clearance complying with Section 306

904.3.3

Visual characters must be mounted at what minimum height above the floor of the viewing position, measured to the baseline of the character?

40 inches (1015 mm)

703.2.9

In new miniature golf facilities, where golf balls rest, the area must be within what maximum distance of a clear floor space?

36 inches (915 mm)

1007.3.2.1

Which type of alteration is exempt from the requirement to upgrade the accessible route, toilet facilities, and drinking fountains serving a primary function area?

Alterations undertaken for the primary purpose of increasing the accessibility of a facility.

IEBC 306.7.1, Exception 4

Speech output on an ATM must be capable of being interrupted and repeated by the user, and what control must be provided for the speech function?

Volume control

707.8.1

Where more than the minimum number of drinking fountains is provided, what percentage of the total number of drinking fountains provided shall comply with the requirements for persons who use a wheelchair?

50 percent

1110.7.2

In an assembly area with a seating capacity of 51 to 200, what is the required calculation for the minimum number of receivers for the assistive listening system?

2, plus 1 per 25 seats over 50 seats

1109.2.7.1, Table 1109.2.7.1

Exposed edges of carpet shall be fastened to the floor and have trim along the entire length that complies with which section?

Section 303

302.2

The stroke width of a raised character, measured at the top surface, shall be what maximum percentage of the height of the uppercase letter “I”?

15 percent

703.3.7.1

In on-street parallel parking where the adjacent sidewalk width exceeds 14 feet (4265 mm), what minimum width access aisle is required at street level?

60 inches (1525 mm)

502.9.1

Where an addition is constructed exclusively for an elevator, the elevator landing must have access to a horizontal exit or to a stairway with a width of not less than how many inches?

36 inches (914 mm).

IEBC 306.6.1.1, Item 2

For water closets primarily for children’s use, what is the maximum height permitted for the top of the water closet seat above the floor?

17 inches (430 mm)

604.11.4

Edge protection permitted at continuous clear openings on piers must be what maximum height and width?

4 inches max height, 2 inches max width

1003.3.1

What action is required for water supply and drain pipes located under sinks in Type A units?

They shall be insulated or otherwise configured to protect against contact

1103.12.4.4

Protruding objects on circulation paths within areas of sport activity are not required to comply with Section 307. Which other area is provided a similar exception, provided ground level accessible routes maintain vertical clearance?

Play areas

1001.3

If the structural or operational characteristics of an amusement ride are altered to the extent that its performance differs from the original design, the amusement ride shall comply with the requirements for new construction found in which section?

Section 1111.4.8 of the International Building Code.

IEBC 306.7.17

Where a toilet paper dispenser is located above the side grab bar, the dispenser outlet must be located within what maximum distance from the rear wall?

36 inches (915 mm)

604.7.1

In new buildings (T-shaped turning space, Option 1), the interior corners at the intersection of each arm and the base must be chamfered for a minimum of what dimension along both the arm and the base?

8 inches (205 mm)

304.3.2.1

The depth of an accessible bench seat shall be within what size range?

20 inches (510 mm) minimum and 24 inches (610 mm) maximum

903.3

The terms “floor” or “floor surface” refer to which surfaces?

The finish floor surface or ground surface, as applicable

105.5

What is the maximum depth permitted for a removable in-tub seat?

16 inches (405 mm)

610.2

An elevator car door reopening device shall be activated by sensing an obstruction passing through the opening at what two nominal heights above the floor?

5 inches and 29 inches

407.3.3.1

Directional signage indicating the location of accessible means of egress must be provided at which location?

At exits serving a required accessible space but not providing an approved accessible means of egress

1009.1

In accessible stairs, what is the maximum permitted height for risers?

7 inches (180 mm)

504.2

Where guards, barriers, or rails are provided, exterior accessible routes serving golf facilities shall be what minimum clear width?

60 inches (1525 mm)

1006.2

In assembly areas with spectator seating, wheelchair spaces shall comply with which section?

Section 802

802.1

Where parking spaces are marked with lines, the width measurements of parking spaces and adjacent access aisles shall be made from which point?

The centerline of the markings

502.3

What is the minimum height required for the raised characters used for floor designations at elevator hoistway entrances?

2 inches (51 mm)

407.2.3.1

The minimum clear width requirement of 48 inches (1219 mm) between handrails is NOT required for accessible means of egress stairways if the stairway is accessed from a refuge area in conjunction with what other means of egress component?

A horizontal exit

1009.3.2, Exception 2

According to the accessible route requirements within Accessible units, an accessible route is NOT required to which area that is part of the unit?

Unfinished attics and unfinished basements

1102.3.1 Exception

The exterior walls separating an exterior area for assisted rescue from the interior of the building must extend horizontally not less than how far beyond the landing on either side?

10 feet (3048 mm)

1009.7.2

Unless a clear or correct key is provided on an ATM/fare machine, how must each operable part be differentiated?

By sound or touch, without activation

707.3

For a stairway to be considered part of an accessible means of egress, what is the minimum clear width required between handrails?

48 inches (1219 mm)

1009.3.2

In an assembly area with stepped or ramped aisles, one accessible means of egress is permitted if the common path of egress travel meets the requirements in which section?

Section 1030.8

1009.1, Exception 2

In Type B units utilizing Option A, what is the minimum clear floor length and width required in front of bathtubs with a forward approach?

60 inches (1525 mm) minimum length and 48 inches (1220 mm) minimum width

1104.11.3.1.3.2

Spacing between the baselines of separate lines of visual characters shall be what minimum and maximum percentage of the character height?

135 percent minimum and 170 percent maximum

703.2.8

Handrails are required on both sides of stairs and ramps, with an exception provided for which areas?

Assembly seating areas

505.2

In Accessible units, maneuvering clearances are generally required by Section 404 at doorways. For which existing area is the existing door to a hospital patient sleeping room exempt from the requirement for space at the latch side?

If the door is 44 inches (1120 mm) minimum in width

1102.5 Exception

If an accessible single-user toilet room is provided due to technical infeasibility of altering existing toilet rooms, in addition to the International Symbol of Accessibility, the sign characters must meet the visual character requirements in accordance with which standard?

ICC A117.1.

IEBC 306.7.12

The calculation for the Prescriptive Method for acoustics in a classroom with a volume less than or equal to 10,000 cubic feet requires the sum of the NRC x S products to be greater than or equal to what ratio of the room volume?

Volume/12

808.2.2

In existing buildings, if the clear width of an accessible route is reduced to 32 inches (815 mm) maximum for a segment of 24 inches maximum, what is the minimum length required to separate these reduced-width segments?

48 inches (1220 mm)

403.5.1

Where self-service shelves are provided in food service lines, at least what percentage, but not less than one, of each type provided shall be accessible?

50 percent

1110.16.3

In Type B units, where exterior deck, patio, or balcony surface materials are impervious, what is the maximum distance the finished exterior impervious surface shall be below the floor level of the adjacent interior spaces?

4 inches (100 mm)

1104.4.2 Exception

At the top and bottom of ramp runs, handrails shall extend horizontally above the landing for what minimum distance?

12 inches (305 mm)

505.10.1

Where separate raised and visual characters are provided for the same information, what is the minimum permitted height for the raised uppercase letter “I”?

1/2 inch (13 mm)

703.3.5 Ex.

Where the public use area is under 5,000 square feet, not more than how many accessible checkout aisles shall be required?

One

1110.16.1

Which of the following is an exception where accessible routes passing through parking facilities are NOT required to be physically separated from vehicular traffic?

Accessible routes crossing drive aisles

507.1

In a Group R-2 occupancy, the alteration to Type A individually owned dwelling units shall be permitted to meet the provision for what other type of unit?

Type B dwelling unit.

IEBC 306.7.3

Thresholds at doorways shall be what maximum height?

1/2 inch (13 mm)

404.2.4

What is the required height range for at least one bed provided in an Accessible unit, measured from the floor to the top of the uncompressed mattress?

17 to 23 inches (430 to 585 mm)

1102.15.3

A hand shower hose shall be what minimum length?

59 inches (1500 mm)

607.6, 608.5

In accessible stairs, what is the minimum required depth for treads?

11 inches (280 mm)

504.2

What must the unit system interface include in a closed-circuit communication system?

A telephone jack capable of supporting voice and TTY communication

1106.7

What is the minimum depth required for a urinal, measured from the outer face of the rim to the finished wall surface?

13 1/2 inches (345 mm)

605.2

At least what minimum percentage of care recipient and visitor parking spaces serving outpatient physical therapy facilities that specialize in treating conditions that affect mobility shall be accessible?

20 percent

1106.5

In a historic structure, if an entrance cannot be made accessible, a locked accessible entrance is permitted if it provides which feature?

A notification system or remote monitoring.

IEBC 306.7.18.3

What is the minimum required clear width between the two handrails provided on a sloped entry?

33 inches (840 mm)

1009.3.3

Which type of public telephone is explicitly exempt from providing a clear floor space?

Drive-up only public telephones

704.2 Ex.

Where fixed or built-in storage elements such as cabinets, coat hooks, or lockers are provided in required accessible spaces, at least what percentage, but not less than one, of each type shall be accessible?

5 percent

1110.12

What is the minimum clear width required for an interior accessible route in a new building or facility?

36 inches (915 mm)

403.5.1

In Type A units, for fixtures not required to comply with Section 1103.11.2, reinforcement for grab bars may comply with Section 1104.11.1. In which specific location is reinforcement for the water closet side wall vertical grab bar component NOT required?

At the water closet

1103.11.1 Exception

Raised characters shall be separated from raised borders and decorative elements by what minimum distance?

3/8 inch (9.5 mm)

703.3.8

In Type C (Visitable) Units, what is the maximum permissible height for thresholds at exterior sliding doors?

3/4 inch (19 mm)

1105.5.3.2 Exception

A clear floor space must be positioned for which approach(es) to an element, unless otherwise specified?

Either forward or parallel approach

305.5

For an addition constructed exclusively to accommodate an elevator to improve accessibility, what system must be provided at all elevator landings that are part of the addition?

Two-way communication in accordance with IBC 1009.8.

IEBC 306.6.1.1, Item 1

All portions of counters required to be accessible shall be located adjacent to what element?

A walking surface complying with Section 403

904.2

What is the minimum required length for the fixed rear-wall grab bar at an accessible water closet?

36 inches (915 mm)

604.5.2

In Type B units, for a refrigerator/freezer where the clear floor space is positioned for a forward approach, what is the maximum offset permitted from the centerline of the appliance to the centerline of the clear floor space?

15 inches (380 mm)

1104.12.2.5.2

The baseline of the lowest raised character shall be mounted at what minimum height above the floor?

48 inches (1220 mm)

703.3.10

Characters or braille shall NOT be located where on a pictogram sign?

In the pictogram field

703.5.2

Buildings and facilities designed and constructed to be accessible shall be in accordance with this code and which standard?

ICC A117.1, as applicable.

IEBC 306.3

A standard roll-in shower compartment (60 inches wide) must have a clearance adjacent to the open face that is 30 inches minimum in depth and what minimum length?

60 inches (1525 mm)

608.2.2.2

If vision lites are more than 66 inches (1675 mm) above the floor, are they required to comply with the 43-inch maximum bottom height rule?

No, vision lites above 66 inches are exempt

404.2.10

Objects with leading edges between 27 inches (685 mm) and 80 inches (2030 mm) above the floor may protrude horizontally into a circulation path by what maximum distance?

4 inches (100 mm)

307.2

What is the maximum operating force permitted for window types other than vertical or horizontal sliding windows?

5 pounds (22.2 N)

506.2

Where additional toilet facilities are being added in occupancies requiring adult changing stations, which room must contain the adult changing station?

Not fewer than one accessible family or assisted-use toilet room.

IEBC 306.7.15

When elongated openings exist in floor surfaces, how must the long dimension be placed relative to the predominant direction of travel?

Perpendicular

302.3

For on-street parallel parking, if the adjacent sidewalk width is 14 feet (4265 mm) or less, an access aisle is not required, provided the parking spaces are located where?

At the end of the block face

502.9.1.2

Audible and visible alarms must be powered by a commercial light and power source and be permanently connected to which system?

The premises electric system

702.1

In Type A units, which operable windows are required to comply with Sections 309.2 and 309.3?

Operable windows required to provide natural ventilation

1103.13.1

In recreational facilities, where additional bathing rooms are being added, which accessible facility must be provided?

Not fewer than one family or assisted-use bathing room.

IEBC 306.7.14

Type B dwelling or sleeping units required by Section 1108 of the International Building Code are required to be provided in historic buildings. (True/False)

False.

IEBC 306.7.18.7

Where a facility provides direct access for pedestrians from a pedestrian tunnel to a building, how many entrances to the building from that tunnel must be accessible?

At least one entrance

1105.1.3

The height of transfer steps in a transfer system shall be what maximum dimension?

8 inches (205 mm)

1009.5.4

In a Type A kitchen, an adjustable height counter providing a work surface is permitted within what height range above the floor?

29 inches (735 mm) minimum and 36 inches (915 mm) maximum

1103.12.3.2 Exception

The running slope of a ramp run shall be greater than 1:20 and not steeper than:

1:12

405.2

For Type B units, which area is specifically not required to be on an accessible route?

A mezzanine that does not have plumbing fixtures or an enclosed habitable space

1104.3.1 Exceptions

Where drinking fountains for persons using wheelchairs and drinking fountains for standing persons are not located adjacent to each other, what must be provided?

Directional signage indicating the route to the nearest like accessible element

1112.3

Where criteria in this standard differ from those of a document referenced in Section 106.2, which criteria shall prevail?

The criteria of this standard shall apply

106.1

Where provided, one accessible passenger loading zone shall be provided in every continuous maximum of how many linear feet of loading zone space?

100 linear feet (30.4 m)

1106.9.1

What is the maximum distance permitted for the separation between corresponding dots in adjacent braille cells (measured center to center)?

0.300 inch (7.6 mm)

703.4.3, Table 703.4.3

In Type B accessible routes, where the clear width is less than 60 inches (1525 mm), passing spaces must be provided at intervals of what maximum length?

200 feet (61 m)

1104.4.1 Exception

What is the maximum slope permitted in all directions for rail platforms?

1:48

805.5.1

A horizontal side-wall grab bar must extend what minimum distance from the rear wall?

54 inches (1370 mm)

604.5.1.1

For ambulatory accessible toilet compartments, grab bars shall be provided on which sides of the compartment?

Both sides of the compartment

604.10.4

When a TTY is in use, the touch surface of the keypads must be what minimum height above the floor?

34 inches (865 mm)

704.5

In Type C (Visitable) Units, where must reinforcement be provided?

For the future installation of grab bars at water closets

1105.6

Sloped entries for swimming pools shall extend to a depth of 24 inches minimum and what maximum depth below the stationary water level?

30 inches (760 mm)

1009.3.2.1

Washing machines and clothes dryers provided in Accessible units must comply with which Section?

Section 611

1102.1

At the top of a stair flight, handrails must extend horizontally above the landing for a minimum of 12 inches (305 mm), beginning directly above which point?

The landing nosing

505.10.2

What is the minimum size required for elevator hall call buttons in the smallest dimension?

3/4 inch (19 mm)

407.2.1.2

The spout on a wheelchair accessible drinking fountain shall be located what maximum distance from the front edge of the fixture, including bumpers?

5 inches (125 mm)

602.2.4

When utilizing Option A (Section 1104.11.3.1) for water closets in Type B units, what is the minimum required clearance width around the water closet, measured perpendicular from the side of the clearance?

48 inches (1220 mm)

1104.11.3.1.2.2.1

In Type C (Visitable) Units, what are the minimum fixtures required in the toilet room or bathroom on the entrance level?

A lavatory and a water closet

1105.6

What type of doors are required for elevators along accessible routes?

Horizontal sliding type

407.3.1

Raised characters shall be raised what minimum distance above their background?

1/32 inch (0.8 mm)

703.3.2

In spaces utilized primarily for viewing motion picture projections, where tiered seating is provided, wheelchair space locations must be integrated into the tiered seating area on a riser or what alternative?

A cross-aisle

802.10.4.1

According to Table 1106.2, how many accessible parking spaces are required for a facility providing a total of 78 parking spaces?

4

1106.2, Table 1106.2

In existing buildings and facilities, what is the minimum diameter required for a circular turning space?

60 inches (1525 mm)

304.3.1.2

Platform boarding edges not protected by platform screens or guards must have what safety feature?

Detectable warning complying with Section 705

805.5.2

In Type A units, what are the clearance depth requirements around the water closet measured perpendicular from the rear wall?

56 inches (1420 mm) minimum

1103.11.2.4.3

Where a forward reach is unobstructed, what is the maximum height permitted for the high forward reach?

48 inches (1220 mm)

308.2.1

In Accessible units, the clear floor space required at the bed (Section 1102.15.1) is also required to serve as what area?

Wheelchair charging area complying with Section 906

1102.15.4

Wheelchair storage spaces provided for transfer devices must comply with Section 305 and shall not overlap what two critical areas?

Required means of egress or accessible route

1002.5.4

For a visual sign mounted greater than 70 inches and up to 120 inches above the floor, what is the minimum character height required if the horizontal viewing distance is 15 feet (4570 mm) or greater?

2 inches (51 mm) plus 1/8 inch (3.2 mm) per foot above 15 feet

703.2.4, Table 703.2.4

A parking facility providing a total of 550 parking spaces must provide a minimum of how many accessible parking spaces?

11

1106.2, Table 1106.2

What is the maximum height permitted for the top of the counter or wall at a shooting facility firing position if shooting over it is required?

34 inches (865 mm)

1010.3

In historic structures, an altered element or space is not required to be on an accessible route, unless required by which sections?

Section 306.7.18.1 or 306.7.18.2.

IEBC 306.7.18, Exception 2

What is the maximum force permitted for pushing or pulling open an interior hinged door?

5.0 pounds (22.2 N)

404.2.8

Where elevator service is not provided in a structure, and the slopes of the planned finished grade measured between the entrance and all vehicular or pedestrian arrival points within 50 feet of the entrance are 10 percent or less, all units on that story shall be required to be Type B units. What percentage refers to the slope?

10 percent

1108.7.1.2

Telephone entry systems shall comply with which ANSI/DASMA standard?

303-2006

708.4

What is the maximum width permitted between the two required handrails on pool stairs?

24 inches (610 mm)

1009.6.2

A jurisdictional body that adopts or enforces regulations and standards for the design, construction or operation of buildings and facilities is known as the:

Administrative authority

107.5

A facility that is constructed or altered to be accessible shall be maintained accessible during what period?

Occupancy.

IEBC 306.2

In Type B units, reinforcement for the rear wall grab bar at a water closet is required to be 24 inches (610 mm) minimum in length, centered on the water closet, only when which condition applies?

Wall space will not permit a grab bar complying with Section 604.5.2

1104.11.1 Exception

The running slope of a walking surface that is part of an accessible route shall not be steeper than what ratio?

1:20

403.3

Where reinforcement for swing-up grab bars is provided at a water closet in a Type B unit, the reinforcement must accommodate a grab bar centered how far from the centerline of the water closet?

15 3/4 inches (400 mm)

1104.11.1.1

A turning space is required within a toilet or bathing room. Where shall this turning space NOT be provided?

Within a toilet compartment

603.2.1

Where a folding seat is provided in a standard roll-in shower, on which wall must it be located?

End wall

608.2.2.3

The counter slope of the gutter or street at the foot of a curb ramp run shall be what maximum ratio?

1:20

406.5.4

Where benches are provided in wet locations, the seat surface shall be slip resistant and must not allow what condition?

Accumulation of water

903.7

Which occupancy group is explicitly exempt from the requirement for areas of refuge at stairways that are part of an accessible means of egress?

Group R-2

1009.3.3, Exception 5

For terms not specifically defined in this standard or in a referenced document, where shall their meaning be sought?

Collegiate dictionaries in the sense that the context implies

107.3

Spaces accessed only by ladders, catwalks, freight elevators, or very narrow passageways are exempt from compliance with Chapter 11. Which other means of access grants this exemption?

Crawl spaces

1103.2.7

In Type C (Visitable) Units, which interior spaces must be included on the entrance level and connected by a circulation path?

A toilet room or bathroom complying with 1105.6 and one habitable space with an area 70 square feet (6.5 m2) minimum

1105.4

Shoulder alignment between the companion seat and the wheelchair space occupant is considered to be 36 inches or more from the front and what distance or more from the rear of the wheelchair space?

12 inches (305 mm)

802.7.2

The tops of tray slides in food service lines shall be located within what height range above the floor?

28 inches (710 mm) minimum and 34 inches (865 mm) maximum

904.5.2

If provided, what is the minimum required length for handset cords in a two-way communication system?

29 inches (735 mm)

708.3

In Accessible units, where are windows explicitly not required to comply with the operable window requirements of Section 506.1?

Kitchens and bathrooms

1102.13 Exceptions

A clear floor space positioned for which type of approach is generally required at accessible dining surfaces and work surfaces?

Forward approach

902.2

What is the minimum clear opening required for doorways intended for user passage in Type B units?

31 3/4 inches (805 mm)

1104.5.2.1

Which element, complying with Section 903, must be provided within an accessible dressing, fitting, or locker room?

A bench

803.4

If a doorway without a door is more than 24 inches (610 mm) in depth, what is the minimum required clear opening width?

36 inches (915 mm)

404.2.2

In the exception allowing a reduced clear pier width of 36 inches minimum and 24 inches maximum length, these segments must be separated by segments that are 60 inches minimum in width and what minimum length?

60 inches (1525 mm)

1003.3.1

Where dining surfaces for the consumption of food or drink are provided, at least what percentage of the dining surfaces for the seating and standing spaces shall be accessible?

5 percent

1109.2.9.1

Signage required for areas of refuge and exterior areas for assisted rescue must include the International Symbol of Accessibility and comply with ICC A117.1 requirements for which types of characters?

Visual characters, raised characters and braille

1009.9

What method is permitted in lieu of speech output for visible output that is not displayed for security purposes (e.g., asterisks representing PINs)?

Audible tones

707.8 Ex. 1

For Group R-2 Type B dwelling or sleeping units, when the work area is greater than 50 percent of the aggregate area of the building, the Type B unit requirements apply only to what quantity?

The quantity of the dwelling or sleeping units being altered or added.

IEBC 306.7.11.3

In a building, room, or space used for assembly purposes with fixed seating, an accessible route is NOT required to serve levels where:

Wheelchair spaces are not provided.

1104.3

The top of the counter edge protection on the aisle side of a checkout counter shall be what maximum height above the top of the counter surface?

2 inches (51 mm)

904.4.2

Which element is explicitly prohibited from being part of an accessible route?

Revolving doors

402.3

In Type B kitchens, where a parallel approach is provided to the cooktop, the clear floor space must be centered on which element?

The appliance

1104.12.2.3.3

In Type A unit kitchens, when is a space NOT required to provide an accessible work surface?

Spaces that do not provide a cooktop or conventional range

1103.12.3 Exception

Accessible dining surfaces and work surfaces shall comply with Section 902, with the exception of surfaces primarily for which user group?

Children's use

902.1

In Type A units, a turning space is not required within closets or pantries, provided they are what maximum depth?

48 inches (1220 mm)

1103.3.2 Exception

Which type of stairway is NOT permitted as part of an accessible means of egress between stories, except when serving a mezzanine?

Exit access stairways connecting levels in the same story

1009.3.1

Audible and visible alarms that are part of a building fire alarm system must be installed in accordance with which referenced standard?

NFPA-72

702.1

Where drinking fountains are provided on an exterior site, on a floor, or within a secured area, what is the minimum number of drinking fountains that shall be provided?

Two

1110.7.1

The water stream flow from an accessible drinking fountain spout shall provide a minimum height of:

4 inches (100 mm)

602.2.5

What is the maximum vertical height permitted for the top of the gripping surfaces of handrails above stair nosings or ramp surfaces?

38 inches (965 mm)

505.4

At a wheelchair-accessible drinking fountain primarily for children’s use, what type of approach is permitted for the clear floor space?

Parallel approach

602.2.1

In existing and new buildings, unless otherwise specified, what is permitted regarding door swing and turning spaces?

Doors shall be permitted to swing into turning spaces

304.4

Each 10 feet of linear pier edge serving boat slips or boarding piers must contain at least one continuous clear opening of what minimum width?

60 inches (1525 mm)

1003.3.1

In units with accessible communication features, if visible doorbell signals are located in sleeping areas, what must be provided?

Controls shall be provided to deactivate the signal

1106.5.1

In load or unload areas of amusement rides, where complying with Section 405.2 (ramp slope) is not structurally or operationally feasible, what is the maximum permitted ramp slope?

1:8

1002.2

What is the maximum horizontal gap permitted between the floor of the amusement ride and the floor of the load/unload area?

3 inches (75 mm)

1002.4.3

What is the minimum required depth for the clearance around an accessible water closet, measured perpendicular from the rear wall?

56 inches (1420 mm)

604.3.2

Signs that provide direction to or information about interior spaces and facilities of the site shall comply with which section?

703.2

703.1.2

Where storage facilities are provided in Accessible units, at least one of each type must comply with Section 905. Which element is specifically exempt from this storage facility requirement?

Kitchen cabinets

1102.14 Exception

In Group R-2, R-3, and R-4 occupancies required to have Accessible, Type A, or Type B units, what minimum percentage of each type of parking space provided shall be accessible (but not less than one)?

2 percent

1106.3

Receivers for assistive listening systems shall include what size standard monaural jack?

1/8 inch (3.2 mm)

706.2

In Type A units, accessible routes shall consist of walking surfaces with a slope not steeper than:

1:20

1103.3.3

In which occupancy groups are two-way communication systems NOT required at elevator landings serving each accessible floor, according to an exception in Section 1009.8?

Group I-2 or I-3 facilities

1009.8, Exception 6

At the bottom of a stair flight, the handrail extension must continue at the slope of the stair for a horizontal distance equal to what measurement beyond the bottom tread nosing?

One tread depth

505.10.3

In Type B units utilizing Option A (Section 1104.11.3.1), if multiple lavatories are provided in a single toilet and bathing area, how many lavatories are required to comply with Section 1104.11.3.1?

Not more than one

1104.11.3.1 Exceptions

Limited-use/limited-application elevators installed in accordance with ASME A17.1 are permitted to be used as a component of which element?

An accessible route.

IEBC 306.7.8

In Accessible units, which specific element is NOT required to comply with Section 404.2.5 regarding maneuvering space between doors in a series?

Storm and screen doors

1102.5 Exception

According to Table 1109.2.2.1, what is the minimum required number of wheelchair spaces for an assembly area with a seating capacity of 85?

4

1109.2.2.1, Table 1109.2.2.1

In alterations, when providing a counter complying with Section 904.3 would reduce the number of existing work stations, what minimum length is permitted for the accessible counter portion using a parallel approach?

24 inches (610 mm)

904.3 Ex.

In assembly and mercantile occupancies, an accessible family or assisted-use toilet room shall be provided where an aggregate of how many or more male and female water closets is required?

Six

1110.2.1

The tops of dining surfaces and work surfaces primarily for children’s use shall be located within what height range above the floor?

26 inches (660 mm) minimum and 30 inches (760 mm) maximum

902.5.2

Where assembly seating has multiple distinct seating areas with amenities that differ from other areas, where must wheelchair space locations be provided?

Within each distinct seating area

802.10.3

Where multiple single-user toilet rooms or bathing rooms are clustered at a single location, at least what percentage, but not less than one room for each use at each cluster, shall be accessible?

50 percent

1110.2

In units with accessible communication features, if a hard-wired electric doorbell is provided, where must the button or switch be located?

On the public side of the unit primary entrance

1106.5.1

What is the maximum force required to activate operable parts?

5.0 pounds (22.2 N)

309.4

In Type A units, if a lavatory measuring 24 inches maximum in depth overlaps the water closet clearance, what is the minimum distance required from the centerline of the water closet to the side edge of the lavatory?

18 inches (455 mm)

1103.11.2.4.4 Exception

In row seating, the companion seat must be located to provide shoulder alignment with the wheelchair space occupant, and the floor surface for the companion seat must be at what elevation?

The same elevation as the wheelchair space floor surface

802.7.2

The bottom tread surface of transfer steps in a transfer system must extend to a water depth of what minimum dimension below the stationary water level?

18 inches (455 mm)

1009.5.4

What is the minimum length required for the horizontal fixed side-wall grab bar at an accessible water closet?

42 inches (1065 mm)

604.5.1.1

In a courtroom, the vertical access to elevated employee work stations is NOT required at initial construction, provided a ramp, lift, or elevator can be installed without requiring reconfiguration or extension of the courtroom or what else?

Extension of the electrical system.

1109.4.1.4

At cut-through pedestrian refuge islands, detectable warning surfaces must be separated by a minimum length of surface without warnings, what is this minimum separation distance?

24 inches (610 mm)

705.7.4

In a Type A U-Shaped kitchen, where counters, appliances, or cabinets are on three contiguous sides, what is the minimum required clearance between opposing elements?

60 inches (1525 mm)

1103.12.1.2

In Accessible units, what minimum Section must elevators within the unit comply with?

Section 407, 408, or 409

1102.7

The back support of a bench shall extend from a point 2 inches maximum above the seat surface to a point what minimum height above the seat surface?

18 inches (455 mm)

903.4

What is the maximum height above the floor required for a work surface in a Type A unit kitchen?

34 inches (865 mm)

1103.12.3.2

If a building fire alarm system is provided, where must the system wiring be extended within a unit required to have communication features?

To a point within the unit in the vicinity of the unit smoke detection system

1106.3

Which seating arrangement is NOT required to comply with the companion seat shoulder alignment requirement?

Tiered seating that includes dining surfaces or work surfaces

802.7.2 Ex.

When reinforcement is provided for grab bars and shower seats in Accessible units’ toilet facilities that do not comply with 1102.11.2, which condition allows this reinforcement to be omitted?

Where Type B units are not provided in the structure

1102.11.1 Exception

An alteration of an existing building shall not impose a requirement for greater accessibility than that which would be required for:

New construction.

IEBC 306.4

If it is technically infeasible to provide accessible dressing, fitting or locker rooms at the same location as similar types of rooms, where must the accessible room be provided?

On the same level.

IEBC 306.7.16

If a service entrance is the only entrance to a tenant space in a facility, that entrance shall be:

Accessible

1105.1.6

What is the minimum required width for a standard accessible car parking space?

96 inches (2440 mm)

502.2

In historic structures, what is the minimum required width for the exterior accessible route, including curb ramps, from a site arrival point to an accessible entrance?

36 inches (914 mm).

IEBC 306.7.18.1

What are the minimum required length and width for the clearance area provided in front of bathtubs in Type B units utilizing Option B (Section 1104.11.3.2)?

48 inches (1220 mm) minimum length and 30 inches (760 mm) minimum width

1104.11.3.2.3.1

Where visible notification appliances are provided in a unit with accessible communication features, they must comply with which section of the general code chapters?

Section 702

1106.4.1

If edge protection on a fishing pier is provided by a curb or barrier, what is the minimum required height of the curb or barrier above the deck surface?

2 inches (51 mm)

1005.4.1

For water closets in Type A units, what is the specific requirement for hand-operated flush controls?

They shall be located on the open side of the water closet

1103.11.2.4.6

What is the definition of a “ramp” in this standard?

A walking surface that has a running slope steeper than 1:20

107.5

What does the definition of “accessible” describe?

A site, building, facility or portion thereof that complies with this standard

107.5

In Type A units, what is the maximum permissible height for a threshold at exterior sliding doors, provided they are beveled with a slope not greater than 1:2?

3/4 inch (19 mm)

1103.5 Exception

The accessible route to an accessible adult changing station shall not require travel through which specific area, in passenger transportation facilities and airports?

Security checkpoints

1110.4.3

In Type B units, what is the required approach for the clear floor space at the kitchen sink?

Parallel approach, centered on the sink bowl

1104.12.2.1

In assembly areas with 300 or fewer seats, horizontal dispersion is not required if the wheelchair space locations are located within which quartile range of the row length?

2nd and 3rd

802.10.1 Ex.

What is the minimum lighting level required for a public visual relay service booth?

20 foot candles (215 lux)

704.7

For a clear floor space positioned for a parallel approach to a Type A refrigerator/freezer, what is the maximum permissible offset of the clear floor space centerline from the centerline of the appliance?

24 inches (610 mm)

1103.12.5.6

When utilizing Option A (Section 1104.11.3.1) for water closets in Type B units, if a forward approach is provided, what is the minimum required clearance depth, measured perpendicular from the rear wall?

66 inches (1675 mm)

1104.11.3.1.2.2.3

What is the minimum required space between the grab bar and projecting objects located above the grab bar?

12 inches (305 mm)

609.3

When required as part of a clear floor space, what is the minimum required depth for toe clearance beneath an element?

17 inches (430 mm)

306.2.3

What are the minimum clear inside dimensions required for a transfer-type shower compartment?

36 inches (915 mm) wide and 36 inches (915 mm) deep

608.2.1.1

In units with communication features, if a hard-wired electric doorbell is provided, activation of the button or switch must initiate what within the unit?

An audible tone

1106.5.1

What is the minimum clear width and length required for wheelchair spaces in amusement rides?

30 inches wide and 48 inches long

1002.4.4.1

Within animal containment areas not otherwise exempted, which requirement shall not be required?

Compliance with Section 303 (changes in level)

1001.4

In Type A units, if a lavatory overlaps the water closet clearance, what is the minimum required length for the reinforcement of the rear wall grab bar, centered on the water closet?

24 inches (610 mm)

1103.11.1 Exception

In dining and drinking areas, an accessible route is not required to a mezzanine provided the mezzanine contains less than 25 percent of the total combined area for dining and drinking and what other condition is met?

The same services and decor are provided in the accessible area.

1109.2.9

The cumulative costs of providing the accessible route, toilet facilities and drinking fountains for an alteration affecting a primary function area are not required to exceed what percentage of the costs of the alterations affecting the area of primary function?

20 percent.

IEBC 306.7.1, Exception 1

In Accessible Units, what section dictates the requirements for walking surfaces that are part of the accessible route?

Section 403

1102.4

Unless specifically stated, figures included in this document are considered what?

Provided for informational purposes only

105.4

Unless otherwise specified, which of the following element clearances are permitted to overlap?

All of the above

301.2

A clear floor space of 60 inches minimum by 96 inches minimum shall be provided within what golf course element?

Course weather shelters

1006.2.4

A pool lift shall be designed so that the seat will submerge to a water depth of what minimum dimension below the stationary water level?

18 inches (455 mm)

1009.2.8

For a sliding door approached from the front, what is the minimum maneuvering clearance required perpendicular to the doorway in a new building?

52 inches (1320 mm)

404.2.3.3

In a Type B unit shower compartment, where the shower is the only bathing facility and has dimensions of 30 inches minimum depth and 44 inches minimum width, what is the minimum required length of clearance measured perpendicular from the control wall?

48 inches (1220 mm)

1104.11.3.1.3.3 Exception

Which chapter’s provisions apply to communication elements and features required to be accessible by the administrative authority’s scoping provisions?

Chapter 7

701.1

Where a visitor communication system is provided at a location other than the unit entry door, the public or common-use interface must include the capability of supporting voice communication and what other communication type with the unit interface?

TTY communication

1106.6.1

Telephones provided within holding or housing cells must have what specific feature?

Volume controls complying with Section 704.3

806.3.2

The stroke width of visual characters shall be what minimum and maximum percentage of the height of the uppercase letter “I” of the font?

10 percent minimum and 30 percent maximum

703.2.6

In a kitchen space where a cooktop or conventional range is NOT provided, what is the minimum required clearance between all opposing base cabinets, countertops, appliances, and walls?

40 inches (1015 mm)

804.2.3

According to Table 802.9.2.2, for rows with 33 to 44 inches of row spacing and a riser height of 12 inches, what is the minimum required height of the wheelchair space location (P) over standing spectators?

37 inches (940 mm)

802.9.2.2, Table 802.9.2.2

What is the raised symbol required on the function key surface for “Cancel”?

"X"

707.6.1, Table 707.6.1

Altered elements of existing elevators shall comply with which ASME standard?

ASME A17.1.

IEBC 306.7.7

In Type B U-Shaped kitchens, where counters, appliances, or cabinets are on three contiguous sides, what is the minimum required clearance between opposing elements?

60 inches (1525 mm)

1104.12.1.2

Door hardware operated by a rotational motion (e.g., knob) shall require a maximum force of:

28 inch-pounds (315 N•cm)

404.2.6

What is the maximum permitted protrusion for handrails into a circulation path?

4 1/2 inches (115 mm)

307.2

In a pass-through kitchen, what is the minimum number of entries required?

Two

804.2.1

Dwelling units and sleeping units are required to comply with Chapter 11 if they are designated as Accessible units, Type A units, Type B units, Type C (Visitable) units, or what other type of unit?

Units with accessible communication features

1101.1

For the maneuvering clearance at the primary entrance swinging door to a Type B unit, what is the minimum dimension required perpendicular to the door for the front approach direction on the push side?

48 inches (1220 mm)

1104.5.1 Exception

Bus route identification numbers on signs shall be visual characters complying with which section?

Section 703.2.4

805.4

Where curbs or other constructed barriers prevent golf cars from entering a fairway, openings 60 inches minimum in width shall be provided at intervals not to exceed:

75 yards (69 m)

1006.3.2

Low resolution VMS characters must be in which case?

Uppercase

703.7.2

Where an addition is constructed exclusively for an elevator, the elevator may not serve a required accessible floor or occupied roof more than how many stories above or below the level of exit discharge?

Four stories.

IEBC 306.6.1.1, Item 3

On accessible routes located on miniature golf playing surfaces, what is the minimum required length for ramp landings?

48 inches (1220 mm)

1007.2

If a clear floor space is confined in an alcove and positioned for a parallel approach, the alcove shall be 60 inches (1525 mm) minimum in width where the depth exceeds what dimension?

15 inches (380 mm)

305.7.1

Signs that identify permanent rooms and spaces must contain both raised characters and what other feature?

Braille

703.1

Where rail station sign space is limited, characters identifying routes and destinations shall not be required to exceed what maximum height?

3 inches (75 mm)

805.6.2 Ex.

Which pictogram is NOT required to have text descriptors?

All of the above

703.1.3 Ex.

In Type A unit kitchens, a clear floor space positioned for a forward approach to a sink is required, providing knee and toe clearance. Under what condition is a clear floor space providing a parallel approach permitted?

If the sink is mounted in an island countertop

1103.12.4.1 Exceptions

Where stadiums, arenas, and grandstands have 15,000 fixed seats or more and provide audible public announcements, what must also be provided?

Captions of those audible public announcements

1109.2.7.3

Where an accessible means of egress serving an addition is within the existing building, the accessible means of egress in the existing building shall comply with which section?

Section 306.7.1.

IEBC 306.6.1, Item 2

A LULA elevator car shall provide a clear floor width of 42 inches (1065 mm) minimum. What is the minimum required clear floor area?

15.75 square feet (1.46 m2)

408.4.1

Two-way communication systems must provide which types of signals?

Both visual and audible signals

708.2

Detectable warning surfaces are required at pedestrian refuge islands, except when those islands are cut-through at street level and are less than what length in the direction of pedestrian travel?

6 feet (1830 mm)

406.6.2

In a pass-through kitchen, where counters or appliances are on two opposing sides, what is the minimum required clearance between them within kitchen work areas?

40 inches (1015 mm)

804.2.1

What type of communication must the public or common-use system interface support, in addition to voice, where a visitor communication system is provided?

TTY communication

1106.6.1

For an Accessible unit, the primary entrance door and all other doorways intended for user passage must comply with which Section?

Section 404

1102.5

What is the standard minimum required width for a van parking space?

132 inches (3355 mm)

502.2

The operable parts of exercise machines and equipment shall not be required to comply with which section?

Section 309

1004.3

The required clearance around the water closet is permitted to overlap which of the following fixtures/elements?

Associated grab bars and the turning space

604.3.3

Chapter 11 contains criteria for which specific unit types?

Accessible units, Type A units, Type B units, Type C (Visitable) dwelling units and units with communication features

202

What are the minimum required length and width for clear floor spaces in Type B units?

48 inches (1220 mm) minimum length and 30 inches (760 mm) minimum width

1104.1.1

Which of the following is NOT an element explicitly exempted from complying with the height and clear floor space requirements of Section 1104.9 for operable parts in Type B units?

Appliance controls

1104.9 Exceptions

What is the minimum clear width required for the toe clearance that must be provided beyond the railing when utilizing an extended ground or deck surface for edge protection?

30 inches (760 mm)

1005.4.2

Which of the following elements is explicitly excepted from complying with the height and operation requirements of Section 309?

Electrical panelboards

309.1

In existing buildings and facilities, what is the minimum required width for an access aisle serving a passenger loading zone vehicle pull-up space?

60 inches (1525 mm)

503.3.2.2

In at least one sleeping area of Accessible units, what minimum percentage of the beds provided must comply with the accessible bed requirements of Section 1102.15?

5 percent, but not less than one bed

1102.15

Changes in level within a required turning space are generally prohibited, with what exception?

Slopes not steeper than 1:48

304.2

A charging station, as defined in this chapter, shall consist of a grounded:

Duplex outlet

906.1

For an ambulatory accessible toilet compartment (Section 604.10), the water closet centerline must be located within what range from the side wall?

17 inches (430 mm) minimum and 19 inches (485 mm) maximum

604.2

Where more than one means of egress is required from an accessible space, what is the minimum number of accessible means of egress required to serve each accessible portion of that space?

Two

1009.1

Where specific criteria of this standard differ from the general criteria of this standard, which criteria shall apply?

The specific criteria shall apply

105.1

In Type A unit kitchens, a clear floor space positioned for a forward approach to a work surface must provide what clearance requirement?

Knee and toe clearance complying with Section 306

1103.12.3.1

In multilevel assembly seating areas, wheelchair spaces shall be provided on the main floor level and on one of each how many additional floor or mezzanine levels?

Two

1109.2.4

In Type B units using Option A (Section 1104.11.3.1), what is the minimum width required for the clear floor space for a parallel approach lavatory, centered on the lavatory?

24 inches (610 mm)

1104.11.3.1.1

In Type B units, what is the required location range for the reinforcement for a sidewall grab bar (24 inches minimum in length) if a 42-inch (1065 mm) grab bar (Section 604.5.1) is not possible?

12 inches (305 mm) maximum from the rear wall

1104.11.1 Exception

Which specific exception is listed regarding the force required for activation of operable parts?

Gas pump nozzles

309.4

A facility that is altered shall comply with the applicable provisions in Chapter 11 of the International Building Code, ICC A117.1 and Sections 306.7.1 through 306.7.18, unless which condition applies?

Technically infeasible.

IEBC 306.7

According to Table 1108.6.1.1, how many total required Accessible units must be provided for a Group R-1 facility with 175 total units?

8

1108.6.1.1, Table 1108.6.1.1

What is the maximum running slope permitted for ramp runs connecting ground level play components?

1:16

1008.4.1.2.1

In Type A units, clearance for a bathtub may permit countertops and cabinetry at one end, provided the countertop and cabinetry can be removed, the floor finish extends under the cabinetry, and what other criteria is met?

The walls behind and surrounding the countertop and cabinetry are finished

1103.11.2.5.1 Exception

In units with accessible communication features, visible notification appliances used for smoke detection must be activated when?

Upon smoke detection

1106.4.2

The distance between two hinged or pivoted doors or gates in series must be 48 inches (1220 mm) minimum plus:

The width of any door or gate swinging into the space

404.2.5

Where additions contain dwelling or sleeping units, to what quantity of units shall the accessibility requirements apply?

Only the quantity of the dwelling or sleeping units in the addition.

IEBC 306.6

For water closets designed for assisted toileting, the length of the swing-up grab bar must be not less than what length, measured from the rear wall to the end of the grab bar?

36 inches (915 mm)

1110.2.2.4

What is the minimum height required for the top of transfer platforms in play areas above the floor?

11 inches (280 mm)

1008.4.2.1.2

In Type C (Visitable) Units, what is the minimum clear width required for doorways?

31 3/4 inches (805 mm)

1105.5.3.1

Operable parts of door hardware shall be located within what height range above the floor?

34 inches (865 mm) minimum and 48 inches (1220 mm) maximum

404.2.6.1

Plumbing elements and facilities required to be accessible by scoping provisions adopted by the administrative authority shall comply with which chapter?

Chapter 6

601.1

What is the minimum required width for exterior accessible routes, including curb ramps, in an existing building?

36 inches (914 mm).

IEBC 306.7.6

What is the minimum clear width required for curb ramp runs, excluding any flared sides, and for blended transitions?

48 inches (1220 mm)

406.5.1

Which alterations are exempt from the requirement to upgrade the accessible route and facilities serving a primary function area, when limited solely to windows, hardware, operating controls, electrical outlets and signs?

Alterations limited solely to the listed elements.

IEBC 306.7.1, Exception 2

Where an alteration includes alterations to a non-accessible entrance, and the facility has an accessible entrance, the altered entrance is not required to be accessible unless required by which section?

Section 306.7.1.

IEBC 306.7.5

Which element is explicitly excepted from complying with the requirements of Section 905 (Storage Facilities)?

Kitchen cabinets

905.1 Ex.

Every required area of refuge shall have direct access to a stairway complying with Section 1009.3 and 1023, or access to which other component complying with Section 1009.4?

An elevator

1009.6.2

For fixtures not required to comply with Section 1103.11.2 in Type A units, when is reinforcement for future installation of grab bars not required in a room containing only a lavatory and water closet?

Provided the room does not contain the only lavatory or water closet on the accessible level of the dwelling unit

1103.11.1 Exception

In a Group B facility, when the building occupant load is greater than 500, each public entrance required to be accessible shall have a minimum of one door that is what type of door?

Power-operated door or a low-energy power-operated door

1105.1.1, Table 1105.1.1

The scoping provisions provided by the administrative authority shall address the application of this standard to which conditions?

New construction, alterations, temporary facilities, and existing buildings

201

In Type A units, storage facilities must comply with Section 905, but which specific type of storage is exempted from this requirement?

Kitchen cabinets

1103.14 Exception

In assembly and mercantile occupancies, an adult changing station is required where family or assisted-use toilet or bathing rooms are required to comply with which section?

Section 1110.2.1

1110.4.1

In a standard roll-in-type shower, the seat must extend from the control wall to a point within what maximum distance of the compartment entry?

3 inches (75 mm)

610.3

Which of the following elements in an Accessible unit must comply with Section 309 for operable parts?

Plumbing fixture controls

1102.9

If a visual sign is mounted 40 to 70 inches above the floor and the viewing distance is less than 6 feet (1830 mm), what is the minimum character height required?

5/8 inch (16 mm)

703.2.4, Table 703.2.4

Knee clearance is defined as the space beneath an element between 9 inches (230 mm) and what maximum height above the floor?

27 inches (685 mm)

306.3.1

The companion seat provided next to a wheelchair space must be equivalent in size, quality, comfort, and amenities to the seats in the immediate area and must also be what?

Permitted to be moveable

802.7.1

In existing buildings, if space limitations necessitate a steeper ramp slope, what is the maximum rise permitted for a ramp with a slope steeper than 1:10 but not steeper than 1:8?

3 inches (75 mm)

405.2

Emergency control buttons within an elevator car shall have their centerlines located at what minimum height above the floor?

35 inches (890 mm)

407.4.6.4.1

Where a high forward reach is over an obstruction, and the reach depth over that obstruction is 20 inches (510 mm) maximum, what is the maximum height permitted for the high forward reach?

48 inches (1220 mm)

308.2.2

What is the primary purpose the clear floor space at the bed in an Accessible unit must also serve?

Wheelchair charging area complying with Section 906

1102.15.4

What is the primary requirement for doors in dressing, fitting, and locker rooms regarding their swing?

Doors shall not swing into the room unless sufficient clear floor space is provided beyond the arc

803.3

What feature must the number Five key have on an accessible ATM numeric keypad?

A single raised dot

707.5

What is the minimum width required for a single wheelchair space in an assembly area?

36 inches (915 mm)

802.3

In units with accessible communication features, which standard must the audible notification component of unit smoke detection comply with?

NFPA 72

1106.2

If compliance with Section 306.7 during an alteration is technically infeasible, what level of access must still be provided?

Access to the maximum extent technically feasible.

IEBC 306.7

Truncated domes must have a base diameter within what size range?

0.9 inch (23 mm) minimum and 1.4 inch (36 mm) maximum

705.5.1

In play areas, where accessible routes serve ground level play components, what is the minimum required height for vertical clearance?

80 inches (2030 mm)

1008.4.1

What is the minimum clear length required for a ramp landing?

60 inches (1525 mm)

405.7.3

Where a curb is provided for edge protection on a ramp or landing, what is the minimum required height of the curb?

4 inches (100 mm)

405.9.2.1

If a Type C (Visitable) unit includes a food preparation area, what is the minimum required clearance between all opposing base cabinets, counter tops, appliances, or walls within that area?

40 inches (1015 mm)

1105.7

Where reinforcement for swing-up grab bars is provided at a water closet in a Type B unit, what is the minimum clearance required from the centerline of the water closet to any side wall or obstruction?

18 inches (455 mm)

1104.11.1.1

In Type B units, clear opening of swinging doors intended for user passage shall be measured between the face of the door and stop, with the door open how many degrees?

90 degrees

1104.5.2.1

In existing buildings and facilities, the clear deck space for a pool lift shall extend forward what minimum distance from a line located 12 inches behind the rear edge of the seat?

48 inches (1220 mm)

1009.2.3.2

In a toilet or bathing room, what is the maximum height permitted for shelves?

48 inches (1220 mm)

603.4

At service windows or counters, any vertical barrier between service personnel and customers shall be located at what maximum height above the floor?

43 inches (1090 mm)

904.3.1

An alteration or addition that decreases the accessibility of a building, facility or element thereof, below the requirements for new construction, is prohibited at what time?

At the time of the alteration or addition.

IEBC 306.2.1

For recreational boating facilities, where the number of boat slips is not identified, each how many feet of boat slip edge provided along the perimeter of the pier shall be counted as one boat slip?

40 feet (12 m)

1111.4.9.1

Where an existing building undergoes a change of occupancy that includes alterations, such alterations shall comply with which section?

Section 306.7.

IEBC 306.5

Signs identifying van parking spaces must contain the designation “van accessible.” Where required, signs shall be located at what minimum height above the floor of the parking space, measured to the bottom of the sign?

60 inches (1525 mm)

502.7

In Type A units, which type of operable window is required to comply with Section 309.2 but is NOT required to comply with Section 309.3?

Operable windows required to provide an emergency escape and rescue opening

1103.13.2

Where an automatic door or gate is required at a public entrance, it must be either a full powered automatic door or gate or a:

Low-energy automatic door or gate

404.3.1

Classrooms not exceeding 20,000 cubic feet and required to provide enhanced acoustics shall comply with which section?

Section 808

808.1

Visual characters (not VMS or combined with raised) shall use which combination of character case?

Uppercase, lowercase, or a combination of both

703.2.2

What type of bed frame is required for at least one bed in an Accessible unit?

Open bed frame

1102.15.2

In new buildings, a doorway without doors or gates that is less than 36 inches (915 mm) in width, approached from the front, must have what minimum maneuvering clearance perpendicular to the doorway?

52 inches (1320 mm)

404.2.3.4

Rail station signs identifying a station or station entrance must provide at least one sign with raised characters and braille complying with which two sections?

Sections 703.3 and 703.4

805.6.1

In a new building, reduced width segments (32 inches minimum) on an accessible route must be separated by segments of what minimum length and width?

52 inches (1320 mm) long and 36 inches (915 mm) wide

403.5.1

For bathtubs with permanent seats, two horizontal grab bars are required on the back wall. The upper bar must extend to within what maximum distance from the control end wall?

12 inches (305 mm)

607.4.1.1

Grab bars on a transfer wall must be perpendicular to the pool wall and their gripping surface must be located within what height range above the transfer wall?

4 inches (100 mm) minimum and 6 inches (150 mm) maximum

1009.4.5

Where required, which space within an Accessible unit is NOT required to provide a turning space?

Closets or pantries that are 48 inches (1220 mm) maximum in depth

1102.3.2 Exception 2

In Accessible units, at least one toilet and bathing facility must comply with Section 603, and the fixtures (lavatory, water closet, tub/shower) must comply with Sections 604 through 610. Where must these fixtures be located?

In a single toilet/bathing area, preventing travel through other parts of the unit

1102.11.2

Where central holding cells are provided and are not separated by age or sex, what is the minimum number of accessible cells required?

At least one accessible cell

1109.4.2.1

Where railings, guards, or handrails are provided along the perimeter of fishing piers or platforms, what minimum percentage of these must be 34 inches (865 mm) maximum in height above the ground or deck surface?

25 percent

1005.3.1

In existing buildings, what is the minimum maneuvering clearance perpendicular to the door required for a manual swinging door approached from the front (push side)?

48 inches (1220 mm)

404.2.3.2

What is the minimum clear width required for a ramp run?

36 inches (915 mm)

405.5

If public address systems convey audible information to the public in transportation facilities, the same or equivalent information must be provided in what format?

Visual format

805.7

In new construction, if the inside car dimension from side to side is 60 inches (1525 mm) minimum, what is the minimum required depth from back wall to inside face of door?

60 inches (1525 mm)

407.4.1

The permitted projection of the nosing beyond the riser shall be what maximum dimension?

1 1/2 inches (38 mm)

504.5

A door closer must be adjusted so that from an open position of 90 degrees, the time required to move the door to an open position of 12 degrees shall be at least how long?

5 seconds

404.2.7.1

A public pay telephone designed to accommodate a portable TTY must be equipped with a shelf having a vertical clearance of what minimum height above the area where the TTY is placed?

6 inches (150 mm)

704.6

For a manual swinging door in a new building, approached from the front (pull side), what is the minimum maneuvering clearance required perpendicular to the doorway?

60 inches (1525 mm)

404.2.3.2

For an elevator to be considered part of an accessible means of egress, standby power must be provided in accordance with Chapter 27 and which other section?

Section 3003

1009.4.1

What is the minimum number of accessible means of egress required from an accessible mezzanine level?

One

1009.1, Exception 1

In Type A units, what is the maximum permissible height for the front of a sink, measured to the higher of the rim or counter surface?

34 inches (865 mm)

1103.12.4.2

Directions for the use of the two-way communication system, instructions for summoning assistance, and written identification of the location must be posted adjacent to the system and comply with ICC A117.1 requirements for:

Visual characters

1009.8.2

Where pictograms are provided as permanent room or space designations, they must comply with Section 703.5 and have text descriptors complying with Sections 703.2 and 703.3 located where?

Directly below the pictogram field

703.1.3

In new buildings and facilities, what is the minimum clear length required for a bus stop boarding and alighting area, measured perpendicular to the curb or vehicle roadway edge?

100 inches (2540 mm)

805.2.2.1

In Accessible units, where are doors permitted to be exempt from the maneuvering clearance required at the latch side of the door?

In existing doors to hospital patient sleeping rooms that are 44 inches (1120 mm) minimum in width

1102.5 Exception

What minimum percentage of the total number of aisle seats provided shall be designated aisle seats?

5 percent

1109.2.5

A continuous passage on which a motorized golf car can operate is defined as a:

Golf car passage

107.5

Where the elevator emergency communication system is altered or replaced, that system shall comply with which section of the International Building Code?

Section 3001.2.

IEBC 306.7.7

Back support for benches must be located what maximum distance from the rear edge of the seat, measured horizontally?

2 1/2 inches (64 mm)

903.4

Which referenced document listed in Section 106.2 addresses criteria for Transportation Vehicles?

Americans With Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles

106.2.1

If the central control point for the two-way communication system is not constantly attended, the system must have timed, automatic telephone dial-out capability to an approved supervising station or what other entity?

Emergency services

1009.8.1

For bus stop boarding and alighting areas, what is the maximum slope permitted perpendicular to the vehicle roadway?

1:48

805.2.3

Access aisles serving parking spaces shall extend for what distance?

The full length of the parking spaces they serve

502.4.3

Furnishings and equipment required to be accessible shall comply with which chapter?

Chapter 9

901.1

Which organization publishes the referenced document dealing with Magnetic Field Strength in Audio-Frequency Induction Loops for Hearing Aids?

International Electrotechnical Commission (IEC)

106.2.2

In a standard roll-in-type shower compartment, what is the minimum required width?

60 inches (1525 mm)

608.2.2.1

Open risers are permitted in accessible stairs under which condition?

Open risers shall not be permitted

504.3

What is the maximum slope permitted for flared sides of a perpendicular curb ramp where a pedestrian circulation path crosses the ramp?

10 percent (1:10)

406.2.3

When edge protection is provided by an extended floor surface, the floor surface must extend at least what distance beyond the inside face of the railing?

12 inches (305 mm)

405.9.1

A side maneuvering clearance provided at the open long side of the adult changing surface must be what minimum depth?

36 inches (914 mm)

613.4.4.1

In Type A units, what is the required maximum vertical height of thresholds at exterior sliding doors, provided they are properly beveled?

3/4 inch (19 mm)

1103.5 Exception

When utilizing Option A for water closets in Type B units, a vanity or obstruction is permitted to overlap the required clearance provided the obstruction is what maximum depth, and the remaining clearance width is what minimum measurement?

24 inches (610 mm) maximum depth and 33 inches (840 mm) minimum remaining clearance

1104.11.3.1.2.2.4

Pool lifts must be located where the water level does not exceed what maximum depth?

48 inches (1220 mm)

1009.2.1

Where two adjacent wheelchair spaces are provided in an assembly area, what is the minimum required width for each wheelchair space?

33 inches (840 mm)

802.3

A van parking space is permitted to be reduced to 96 inches (2440 mm) minimum in width, provided the adjacent access aisle has what minimum width?

96 inches (2440 mm)

502.2

Interior and exterior signs identifying permanent rooms and spaces shall comply with which three sections?

703.1, 703.2, and 703.3

703.1.1

For bottom-hinged door ovens, the required accessible work surface must be positioned adjacent to which location?

One side of the door

804.5.5.3

The vertical grab bar on the side wall shall be 18 inches minimum in length and mounted with its bottom edge located within what height range above the floor?

39 inches (990 mm) minimum and 41 inches (1040 mm) maximum

604.5.1.2

Changes in level in floor surfaces that are 1/4 inch (6.4 mm) maximum in height are permitted to be installed in what manner?

Vertical

303.2

For ramps that are part of the circulation path in Type C (Visitable) Units, when are handrails, intermediate landings, and edge protection NOT required?

Where the sides of ramp runs have a vertical drop off of 1/2 inch (13 mm) maximum within 10 inches (255 mm) horizontally of the ramp run

1105.5.4 Exception

What is the maximum cross slope permitted for ramp runs?

1:48

405.3

Accessible units must comply with all requirements in which section?

Section 1102

1102.1

In Type B units, which type of operable part is specifically exempted from complying with Sections 309.3 and 1104.1.1?

Plumbing fixture controls

1104.9 Exception

When calculating required size or dimension involving ratios or percentages, rounding down for values less than what fraction shall be permitted?

One half

105.2

Where unit smoke detection is provided in a unit with accessible communication features, what element must be included for notification?

Audible notification complying with NFPA 72

1106.2

The technical criteria intended to make sites, facilities, and buildings accessible are primarily found in which section range of this standard?

Chapters 3 through 10, Sections 1102, 1103 and 1106

102.1

For the maneuvering clearance at Type B unit primary entrance doors, for a front approach sliding or folding door, what minimum dimension is required perpendicular to the door?

48 inches (1220 mm)

1104.5.1 Exception

In Type C (Visitable) Units, what are the minimum and maximum heights above the floor for receptacle outlets and operable parts of lighting controls?

15 inches (380 mm) minimum and 48 inches (1220 mm) maximum

1105.8

In a Type A unit combination refrigerator/freezer, what percentage and height requirement applies to the freezer compartment shelves?

At least 50 percent of the freezer compartment shelves shall be 54 inches (1370 mm) maximum above the floor

1103.12.5.6

In existing buildings and facilities, what is the minimum clear length required for a bus stop boarding and alighting area, measured perpendicular to the curb or vehicle roadway edge?

96 inches (2440 mm)

805.2.2.2

What is the minimum required vertical clearance for vehicle pull-up spaces and their access aisles at passenger loading zones?

114 inches (2895 mm)

503.5

For hand-operated flush controls in Type A water closets, where must the control be located?

On the open side of the water closet

1103.11.2.4.6

Where adult changing stations are provided in a single-user toilet room, which component must be provided in the room?

Coat hook

613.2.1

If a permanent seat is provided at the head end of an accessible bathtub, the required clearance in front of the tub must extend what minimum distance beyond the wall at the head end?

12 inches (305 mm)

607.2

If a Type C (Visitable) Unit entrance is provided via a circulation path, that path must lead from a public street or sidewalk, a dwelling unit driveway, or what other location?

A garage

1105.2

Type A dwelling units shall comply with which section of the code?

Section 1103

1103.1

The width of the uppercase letter “O” for visual characters shall be what percentage range of the height of the uppercase “I” of the font?

55 percent minimum and 110 percent maximum

703.2.5

What is the minimum illumination level required for interior stairways during conditions of stair use?

10 foot-candles (108 lux)

504.9.1

In standard roll-in showers, the back-wall grab bar must extend within what maximum distance from the adjacent side wall opposite the seat?

6 inches (150 mm)

608.3.2.1

In Type B units, lighting controls and receptacle outlets located over cabinets with countertops are permitted, provided the countertop is what maximum height and maximum depth?

36 inches (915 mm) maximum height and 25 1/2 inches (650 mm) maximum depth

1104.9 Exception

If it is technically infeasible to alter existing toilet rooms to be accessible, what alternative accessible facility is permitted on the same floor and in the same area?

One accessible single-user toilet room or one accessible family or assisted-use toilet room.

IEBC 306.7.12

If a shower compartment is the only bathing facility in a Type B unit (Option A), and has minimum dimensions of 36 inches by 36 inches, what is the minimum length and depth required for the clearance area measured from the control wall?

48 inches (1220 mm) minimum length and 30 inches (760 mm) minimum depth

1104.11.3.1.3.3

Seating treads less than 33 inches (840 mm) in depth shall not be permitted with risers greater than what height?

18 inches (455 mm)

802.9.2.2, Note 3

Detectable warning surfaces shall extend what minimum distance in the direction of pedestrian travel?

24 inches (610 mm)

705.6

What is the minimum clear opening width required for a doorway?

32 inches (815 mm)

404.2.2

What is the minimum required length for an accessible bench seat?

42 inches (1065 mm)

903.3

For a swinging door, the clear opening width shall be measured between the face of the door and the stop with the door open to what degree?

90 degrees

404.2.2

Which referenced document addresses performance criteria for Accessible Communications Entry Systems?

ANSI/DASMA 303-2006

106.2.5

In existing buildings and facilities, what is the minimum depth required for a wheelchair space that is only entered from the side?

60 inches (1525 mm)

802.4.2

Changes in level greater than 1/4 inch (6.4 mm) and not more than 1/2 inch (13 mm) maximum shall be beveled with a slope not steeper than what ratio?

1:2

303.3

Dwelling units and sleeping units shall comply with the applicable provisions of which chapter of this standard?

Chapter 11

102.2

The requirements for Accessible dwelling or sleeping units (Group I-1, I-2, I-3, R-1, R-2, or R-4) being altered or added apply only to:

The quantity of dwelling or sleeping units being altered or added.

IEBC 306.7.11.1

What is the specific description of a “blended transition”?

A raised pedestrian street crossing, depressed corner or similar connection between the pedestrian access route and the street crossing that has a grade of 1:20 or less

107.5

If stair nosings are rounded, what is the maximum permitted radius of curvature at the leading edge of the tread?

1/2 inch (13 mm)

504.5

If platform lifts are installed within an Accessible unit, they must comply with which section?

Section 410

1102.8

What is the minimum height and depth of knee clearance required at accessible play tables?

24 inches high, 17 inches deep

1008.4.3.3

For audible car position indicators, the verbal announcement indicating the floor shall be completed prior to what action?

The initiation of the door opening

407.4.9.2.1

How many van-accessible parking spaces must be provided for every 10 accessible parking spaces?

2

1106.6

In Type C (Visitable) Units, the water closet must comply with clearances specified in which section?

Section 1104.11.3.1.2

1105.6

What is the maximum height permitted for thresholds in roll-in-type shower compartments?

1/2 inch (13 mm)

608.6

What is the maximum permitted height for the top of an accessible water closet seat above the floor?

19 inches (485 mm)

604.4

A clear floor space positioned for a parallel approach to a refrigerator/freezer shall have its centerline offset what maximum distance from the centerline of the appliance?

24 inches (610 mm)

804.5.6

In new buildings and facilities, what is the minimum required length and width for a clear floor space?

52 inches long and 30 inches wide

305.3.1

In Type B units utilizing Option A, if a shower compartment is the only bathing facility, and has minimum dimensions of 36 inches by 36 inches, how wide is the clearance required from the face of the shower compartment?

30 inches (760 mm) minimum

1104.11.3.1.3.3

Classroom ambient sound levels shall not exceed what maximum sound level due to intruding noise from sources outside of the classroom?

35 dBA and 55 dBC

808.3.1

In historic structures where toilet rooms are provided, the requirement is for not fewer than one accessible single-user toilet room or:

One accessible family or assisted-use toilet room complying with IBC 1110.2.1.

IEBC 306.7.18.4

The floor surface of wheelchair spaces in amusement rides shall have a slope not steeper than what ratio when in the load and unload position?

1:48

1002.4.2

Charging stations shall comply with at least one of the reach ranges specified in which section?

Section 308

906.3

Platform lifts used as part of an accessible means of egress must be provided with standby power in accordance with which chapter?

Chapter 27

1009.5

What is the maximum height permitted for the spout outlet of a drinking fountain designed for persons using wheelchairs?

36 inches (915 mm)

602.2.3

In existing buildings, where an accessible route makes a 180-degree turn around an object less than 48 inches in width, what are the minimum widths approaching, during, and leaving the turn?

42 inches (1065 mm) approaching, 48 inches (1220 mm) during, 42 inches (1065 mm) leaving

403.5.2.2

If vertical clearance is reduced below the minimum required, a rail or barrier must be provided, and the leading edge of this barrier must be located at what maximum height above the floor?

27 inches (685 mm)

307.4

The administrative authority shall specify the extent to which the dwelling and sleeping unit criteria apply using what method?

Separate scoping provisions

202

What is the minimum required height for a pictogram field?

6 inches (150 mm)

703.5.2

Where check writing surfaces are provided, they must comply with which section?

Section 902.4

904.4.3

At least one section of accessible counter/work surface in a Type A unit must be provided with a minimum length of:

30 inches (760 mm)

1103.12.3

In Group I-1, Condition 1 occupancies, what is the minimum percentage of dwelling units and sleeping units that shall be Accessible units?

4 percent

1108.5.1.1

Seating within an arc measured from the sign language interpreter station must be provided with sight lines viewing the station from a horizontal distance of what maximum length?

65 feet (19.8 m)

802.11.3

In Type C (Visitable) Units, which item is explicitly NOT required to comply with the height requirements of Section 1105.8?

Lighting controls and receptacle outlets over countertops

1105.8 Exception

What is the maximum rise permitted for any single ramp run?

30 inches (760 mm)

405.6

Wheelchair space locations in assembly areas must be provided with a companion seat complying with Section 802.7 located where?

Beside each wheelchair space

802.7

In general-purpose hospitals, psychiatric facilities, and detoxification facilities of Group I-2 occupancies, what is the minimum percentage of dwelling units and sleeping units that shall be Accessible units?

10 percent

1108.5.3.1

At least two percent of the total, but not fewer than one, of each gaming machine type and gaming table type shall be accessible. What other requirement applies when multiple gaming areas occur?

Accessible gaming machines and gaming tables shall be distributed throughout.

1110.19

What is the minimum required length for the changing surface of an adult changing station?

70 inches (1778 mm)

613.4.1

For historic structures, the alteration to Type A individually owned dwelling units within a Group R-2 occupancy is permitted to meet the provision for which type of unit?

Type B dwelling unit.

IEBC 306.7.18.6

Where side rails are provided at the changing surface, they shall be a minimum of what fraction of the length of the changing surface?

2/3

613.4.5.1

Which alterations are exempt from the requirement to upgrade the accessible route, toilet facilities, and drinking fountains serving an area of primary function?

Alterations limited solely to mechanical systems, electrical systems, installation or alteration of fire protection systems and abatement of hazardous materials.

IEBC 306.7.1, Exception 3

If edge protection on a fishing pier is provided by an extended deck surface, the deck surface must extend what minimum distance beyond the inside face of the railing?

12 inches (305 mm)

1005.4.2

In Type A units, where is a countertop required to be positioned relative to a side-hinged door oven?

Adjacent to the latch side of the oven door

1103.12.5.5.2

Within areas of sport activity exempted in this chapter, which requirement for floor and ground surfaces is not required to be met?

Stable, firm and slip resistant surface (Section 302)

1001.2.2

Where one grab bar is provided on a transfer wall, what minimum clearance must be maintained on both sides of the grab bar?

24 inches (610 mm)

1009.4.5

What is the minimum required length for the telephone handset cord for a public telephone?

29 inches (735 mm)

704.2.4

Stair level identification signs in enclosed stairways must be located where?

At each floor level landing adjacent to the door leading from the stairwell into the corridor

504.1

Spacing between individual visual characters (excluding word spaces) shall be measured between the two closest points of adjacent characters and be within what percentage range of the character height?

10 percent minimum and 35 percent maximum

703.2.7

The uppercase letter “I” on an ATM display screen shall be what minimum height?

1/4 inch (6.4 mm)

707.7.2

What is the minimum clear width required for an exterior accessible route?

48 inches (1220 mm)

403.5.1

Where provided in an Accessible unit, kitchens shall comply with which section of the code?

Section 804

1102.12

In a U-shaped kitchen (enclosed on three contiguous sides), what is the minimum required clearance between opposing base cabinets, countertops, appliances, or walls within the kitchen work area?

60 inches (1525 mm)

804.2.2

When determining the minimum character height for visual characters, what letter is used to determine the allowable height of all characters of a font?

The uppercase letter "I"

703.2.4

Braille shall be 48 inches (1220 mm) minimum and what maximum height above the floor, measured to the baseline of the braille cells?

60 inches (1525 mm)

703.4.5

In a Type B kitchen, if two or more receptacle outlets are provided above a length of countertop that is uninterrupted by a sink or appliance, how many receptacle outlets must comply with the operable parts requirements (Section 1104.9)?

Only one

1104.9 Exception

Accessible pedestrian signals must comply with which section of the Manual on Uniform Traffic Control Devices?

Section 4E.09 through 4E.13

703.9

What is the maximum size for interior common use circulation paths within employee work areas that are defined by permanently installed partitions, counters, casework or furnishings, to be exempt from being required accessible routes?

1,000 square feet (93 m2)

1104.3.1

Grab bars provided on each transfer step in a transfer system must have their gripping surface located within what height range above each step?

4 inches (100 mm) minimum and 6 inches (150 mm) maximum

1009.5.7

In Group R-2 occupancies containing more than 20 dwelling units or sleeping units, what is the minimum percentage of the units that shall be a Type A unit?

2 percent

1108.6.2.2.1

The provisions of Chapter 3 (Building Blocks) apply where required by the administrative authority’s scoping provisions or by which subsequent chapters?

Chapters 4 through 11

301.1

In Accessible units, if doors leading to a balcony have exterior space dimensions less than the required maneuvering clearance, what is the exemption applied to the exterior side of the door?

Door maneuvering clearance is not required on the exterior side

1102.5 Exception

Where a high side reach is over an obstruction, what is the maximum height permitted for that obstruction?

34 inches (865 mm)

308.3.2

Which raised structure, used solely for a sports activity, is generally NOT required to comply with this standard?

Raised structures used solely for refereeing, judging, or scoring a sport

1001.2.1

The front of accessible lavatories and sinks shall be located at what maximum height above the floor, measured to the higher of the rim or counter surface?

34 inches (865 mm)

606.3

Accessible van parking spaces and their access aisles must be provided with what minimum vertical clearance?

98 inches (2490 mm)

502.6

Within a clear floor space, changes in level shall not be permitted, with the exception of slopes not steeper than what ratio?

1:48

305.2

What is the minimum vertical clearance required for circulation paths?

80 inches (2030 mm)

307.4

One option for a required passing space in a new building is a 60-inch minimum by 60-inch minimum space. What is the alternative option?

An intersection providing a T-shaped turning space, where the base and arms extend 52 inches minimum beyond the intersection

403.5.4.1

What is the minimum number of sloped entries required for a wading pool?

At least one

1009.1.2

Signs complying with IBC Section 1112 must be provided at the public entrances and which other entrance in a historic structure?

The accessible entrance.

IEBC 306.7.18.3

Raised characters must be of which style?

Sans serif

703.3.4

For an exterior area for assisted rescue, the sides other than the separation walls shall be open to the outside air by a minimum percentage of:

50 percent

1009.7.3

Accessible routes within Accessible units may consist of walking surfaces, ramps, elevators, platform lifts, and which other component?

Doors and doorways

1102.3.3

For Accessible units, clear floor space is required on both sides of the bed, positioned for a parallel approach. What is permitted as an exception to this rule?

Where a single clear floor space positioned for parallel approach is provided between two beds, a clear floor space shall not be required on both sides of the bed

1102.15.1 Exception

Objects located more than 27 inches above the floor of the wheelchair space are permitted to protrude what maximum distance along the front of the wheelchair space?

25 inches (635 mm)

1002.4.4.3

What is the minimum required range of view for peepholes, where used, as a means for visually identifying a visitor at the unit primary entrance in units with communication features?

180-degree range of view

1106.5.2

What kind of space must be provided in load and unload areas of amusement rides?

A turning space complying with Sections 304.2 and 304.3

1002.3

What is the maximum slope permitted for the floor surface of wheelchair space locations in assembly areas?

1:48

802.2

In a Type A unit bathroom complying with Section 1103.11.2.2, if cabinetry is permitted under the lavatory, what specific finishing requirement must be met for the walls?

The walls behind and surrounding the cabinetry must be finished

1103.11.2.2 Exception

Clear floor spaces required at accessible gaming machines and tables shall be permitted to do what?

Overlap

907.1

In Type B units, mailboxes serving the unit are permitted an unobstructed side reach range at what maximum height above the floor?

54 inches (1370 mm)

1104.1.2

What is the exception to the 80-inch minimum vertical clearance requirement?

Suspended piping

307.4

Accessible benches must be able to support a vertical or horizontal force of what minimum weight applied at any point on the seat?

250 pounds (1112 N)

903.6

Existing means of egress need not be maintained during construction where what alternative condition is met?

Approved temporary means of egress and accessible means of egress systems and facilities are provided.

IEBC 306.2, Exception

What is the maximum age defining “children’s use” spaces and elements?

12 years old and younger

107.5

For visible hall signal fixtures, the center shall be located at what minimum height above the floor?

72 inches (1830 mm)

407.2.2.2

For a Type A refrigerator/freezer where a parallel approach is provided, what is the maximum offset permitted between the centerline of the clear floor space and the centerline of the appliance?

24 inches (610 mm)

1103.12.5.6

Stairways that are part of an accessible means of egress must either incorporate an area of refuge within an enlarged floor-level landing or be accessed from an area of refuge complying with which section?

Section 1009.6

1009.3.3

Where play components require transfer to entry points or seats, the entry point or seat height shall be what maximum dimension from the clear floor space?

24 inches (610 mm)

1008.4.3.4

A clear floor space 48 inches minimum by 60 inches minimum with slopes not steeper than 1:48 shall be provided at which location in miniature golf facilities?

The start of play

1007.3.1

Where benches are provided, the clear floor space must be positioned at the end of the bench seat and parallel to which axis of the bench?

The short axis

903.2

Special rooms and spaces required to be accessible shall comply with the applicable provisions of which chapter?

Chapter 8

801.1

What is the minimum vertical force required to be structurally supported by grab bars?

250 pounds (1112 N)

609.8

What is the minimum required base-to-base spacing for adjacent truncated domes on the grid?

0.65 inch (16.5 mm)

705.5.3

Which term describes a space for a single wheelchair and its occupant?

Wheelchair space

107.5

Signage identifying access to an exterior area for assisted rescue must state:

"EXTERIOR AREA FOR ASSISTED RESCUE"

1009.9

Where a high forward reach is over an obstruction, and the reach depth over the obstruction is greater than 20 inches (510 mm) and not more than 25 inches (635 mm) maximum, what is the maximum height permitted for the high forward reach?

44 inches (1120 mm)

308.2.2

If a VMS message can be displayed in its entirety on a single screen, it must remain motionless on the screen for a minimum of 3 seconds or a minimum of one second for every how many characters, whichever is longer?

7 characters

703.7.14

What is the minimum diameter required for the base of a single braille dot?

0.059 inch (1.5 mm)

703.4.3, Table 703.4.3

Cabinetry is permitted under a lavatory in a Type A unit bathroom complying with Section 1103.11.2.2, provided the cabinetry can be removed without removal or replacement of the lavatory, the walls behind are finished, and what other criterion is met?

The floor finish extends under the cabinetry

1103.11.2.2 Exception

Hand-operated metering faucets must remain open for what minimum duration?

10 seconds

606.4

For line of sight over standing spectators, the front of the wheelchair space shall be located what maximum distance from the back of the chair or bench in front?

12 inches (305 mm)

802.9.2.1

Where more than three clothes dryers are provided in spaces required to be accessible, what is the minimum number that must be accessible?

Not less than two

1110.6.2

The display screen of an ATM must be visible from a point located at what height above the center of the clear floor space in front of the machine?

40 inches (1015 mm)

707.7.1

What is the stated intent of the technical criteria in Chapters 3 through 10?

To allow a person with a physical disability to independently get to, enter, and use a site, facility, building or element

102.1

For an Accessible unit, the primary entrance is required to be on an accessible route from public and common areas. Under what condition is the primary entrance permitted to be located to a bedroom?

If it is the only entrance

1102.2

For a parallel approach counter, what is the minimum required space between the accessible counter surface and any projecting objects above it?

12 inches (305 mm)

904.3.2

Wheelchair accessible toilet compartment doors shall be self-closing, and where shall a door pull complying with Section 404.2.6 be placed?

On both sides of the door near the latch

604.9.3

For drinking fountains for persons who are standing, what is the minimum height required for the spout outlet above the floor?

38 inches (965 mm)

602.3.2

What is the minimum elevated height above grade required for shooting facilities on freestanding platforms to be exempt from this standard, provided the aggregate area is 500 square feet maximum?

12 feet (3660 mm)

1001.2.1

Built-in storage facilities shall comply with at least one of the reach ranges specified in which section?

Section 308

905.3

Raised areas used primarily for purposes of security, life safety, or fire safety, such as observation galleries and prison guard towers, are exempt from Chapter 11 requirements, except when the area is what size?

Not specified in the exemption; they are entirely exempt.

1103.2.6

In Group I-3 occupancies, what minimum percentage of the total number of sleeping units in the facility shall be Accessible units?

3 percent

1108.5.5.1

What must identify assistive listening systems?

The International Symbol of Access for Hearing Loss

703.6.3.3

Assistive listening systems must be capable of providing a sound pressure level within what range?

110 dB minimum and 118 dB maximum

706.5

What is the maximum horizontal distance that a beveled nosing shall extend at the leading edge of a stair tread?

1/2 inch (13 mm)

504.5

The nonglare finish requirement for symbols of accessibility and their backgrounds shall not exceed how many gloss units (gu)?

19 gloss units (gu)

703.6.2.1

Dwelling units and sleeping units required to have communication features shall comply with which section?

Section 1106

1106.1

What element is NOT listed as a component that an accessible route may consist of in Accessible Units?

Stairs

1102.3.3

What is the minimum size of the level and clear floor area required for a sign language interpreter station?

24 inches (610 mm) deep and 36 inches (915 mm) wide

802.11.2

For Type B units, the clear width of an accessible route is generally required to comply with Section 403.5, but is permitted to be reduced to 32 inches minimum for what maximum length?

24 inches (610 mm)

1104.4.1 Exception 1

For a water closet required to comply with Section 1103.11.2.4 in a Type A unit, what is the required minimum and maximum measurement for the centerline of the water closet from the sidewall?

16 inches minimum and 18 inches maximum (405 mm to 455 mm)

1103.11.2.4.1

In a Type A toilet/bathing facility required to comply with Section 1103.11.2, doors are permitted to swing into the clear floor space or clearance for a fixture under which condition?

Where a clear floor space is provided within the room beyond the arc of the door swing

1103.11.2.1 Exception

According to Table 1110.16.1, what is the minimum number of accessible checkout aisles required for a facility providing 12 total checkout aisles of the same function?

3

1110.16.1, Table 1110.16.1

When measuring the width of visual characters, which uppercase letter is used to determine the allowable width?

"O"

703.2.5

Where more than one accessible means of egress is required, what is the minimum fire-resistance rating required for exterior walls separating an exterior area for assisted rescue from the interior of the building?

1 hour

1009.7.2

The height of a transfer wall shall be 16 inches minimum and what maximum height measured from the deck?

19 inches (485 mm)

1009.4.2

For bathtubs with removable seats, a horizontal grab bar 12 inches minimum in length must be provided on which wall?

Head end wall at the front edge of the bathtub

607.4.2.3

In cells required to have communication features, where audible emergency alarm systems are provided, visible alarms must comply with Section 702, except in cells where inmates or detainees are not allowed what?

Independent means of egress

806.3.1 Ex.

Instructions posted in areas of refuge or exterior areas for assisted rescue must include that persons able to use the exit stairway should do so as soon as possible, unless they are engaged in what activity?

Assisting others

1009.11

In a transfer system, what is the minimum clear depth required for the transfer platform?

19 inches (485 mm)

1009.5.1

A two-way communication system is required at elevator landings on each accessible floor that is how far above or below the level of exit discharge?

One or more stories

1009.8

Toe clearance is defined as the space beneath an element between the floor and what minimum height above the floor?

9 inches (230 mm)

306.2.1

Which of the following Group U occupancies is required to comply with Chapter 11?

Private garages or carports that contain required accessible parking.

1103.2.4

In a transfer-type shower, controls and hand shower shall be located on the control wall opposite the seat, at a height of 38 inches minimum and what maximum height above the shower floor?

48 inches (1220 mm)

608.4.1

During construction, demolition, remodeling, or alterations and additions to any occupied building, which elements must be maintained?

Required accessible means of egress.

IEBC 306.2

Changes in level greater than 1/2 inch (13 mm) in height shall be accomplished by which means?

A ramp complying with Section 405 or curb ramp complying with Section 406

303.4

Accessible floor surfaces must be stable, firm, and what other characteristic?

Slip resistant

302.1

Stair treads must have visual contrast provided by a solid color contrasting marking. This marking must cover what minimum and maximum horizontal distance, measured from the leading edge of the nosing?

1 to 2 inches (25 to 51 mm)

504.6

An adult changing station and its support structure must be able to support a user weight of not less than what minimum amount?

400 pounds (182 kg)

613.4.2

What is the minimum clear width required for an escalator provided in a transportation facility?

32 inches (815 mm)

805.9

Dining surfaces and work surfaces that are 15 inches minimum and 24 inches maximum in height are permitted to have a clear floor space positioned for which type of approach?

Parallel approach

902.2 Ex. 2

Which specific sections provide criteria for Type B units, intended to be consistent with HUD Fair Housing Accessibility Guidelines?

Section 1104

1104

What is the required height of truncated domes?

0.2 inch (5.1 mm)

705.5.2

What is the minimum required width and length for a vehicular pull-up space at a passenger loading zone?

96 inches (2440 mm) wide and 20 feet (6095 mm) long

503.2

A noncircular handrail cross section shall have a maximum cross-section dimension of:

2 1/4 inches (57 mm)

505.7.2

In Type B units, which area is NOT required to be on an accessible route?

A mezzanine that does not have plumbing fixtures or an enclosed habitable space

1104.3.1 Exception

In structures without elevator service located in flood hazard areas, Type A and Type B units are not required where the difference in elevation between the minimum required floor elevation at the primary entrances and arrival points within 50 feet exceeds what amount?

30 inches (762 mm)

1108.7.5

In general, horizontal grab bars must be installed within what height range above the floor, measured to the top of the gripping surface?

33 inches (840 mm) minimum and 36 inches (915 mm) maximum

609.4.1

What is the maximum depth that toe clearance is permitted to extend under an element?

25 inches (635 mm)

306.2.2

In new buildings, platform lifts with doors on adjacent sides must provide what minimum clear floor dimensions?

42 inches (1065 mm) wide and 60 inches (1525 mm) deep

410.5.2.1

For bottle filling stations, what types of clear floor space approach are permitted?

Forward or side approach

602.4.1

Accessible unit mirrors above lavatories complying with Section 606 must have the bottom edge of the reflecting surface located what maximum height above the floor?

40 inches (1015 mm)

1102.11.2.2

If a clear floor space is positioned for a forward approach at a cooktop, what protection must be provided for the underside of the cooktop?

Must be insulated or otherwise configured to prevent burns, abrasions, or electrical shock

804.5.4.2

In a building equipped throughout with an automatic sprinkler system, the elevator required by Section 1009.2.1 is NOT required as part of the accessible means of egress if the floor is located at or above the level of exit discharge and provided with which component?

A horizontal exit

1009.2.1, Exception 1

Under what condition must an exterior area for assisted rescue (EAAR) be provided on the exterior landing?

If the exit discharge does not include an accessible route from the exit to a public way.

1009.7

Alternatives to the designs, products, or technologies prescribed by this standard are permitted provided they result in equivalent or greater accessibility AND:

Such equivalency is approved by the administrative authority adopting this standard

104.1

A wheelchair space shall not overlap the required width of an aisle, except that in new buildings, the depth of a wheelchair space shall be permitted to overlap the required aisle width by what maximum dimension?

4 inches (100 mm)

802.5.1

For historic buildings with multiple levels, an accessible route must be provided from an accessible entrance to which public spaces?

Public spaces on the level of the accessible entrance.

IEBC 306.7.18.2

An accessible route shall not be required between site arrival points and the building or facility entrance if the only means of access is a vehicular way not providing for pedestrian access, EXCEPT in which case?

In buildings or facilities containing or serving Type B units.

1104.1

For a standard accessible water closet, grab bars shall be provided on which two walls?

Rear wall and side wall closest to the water closet

604.5

If tiered seating in assembly areas includes dining surfaces or work surfaces, wheelchair spaces shall comply with Sections 802.6, 802.7, 802.9, 802.10, and which other section?

Section 902

802.1

What is the maximum permitted height for thresholds at exterior sliding doors in Type B units?

3/4 inch (19 mm)

1104.5.2.2 Exception

At least one toilet and bathing facility in an Accessible unit must comply with Section 1102.11.2. How must the required accessible lavatory, water closet, and bathtub or shower be configured?

They must be in a single toilet/bathing area, such that travel between fixtures does not require travel through other parts of the unit

1102.11.2

At least 5 percent, but not fewer than 1, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges must be designed so that what can enter and exit?

A person in a wheelchair

1006.2.4

What is the minimum required length for the accessible work surface in an accessible kitchen?

30 inches (760 mm)

804.3

What is the minimum required width for the clearance around an accessible water closet, measured perpendicular from the sidewall?

60 inches (1525 mm)

604.3.1

For Accessible Units, ramps must comply with which section?

Section 405

1102.6

If an addition affects the accessibility to, or contains an area of, a primary function, it shall comply with the requirements in which section?

Section 306.7.1.

IEBC 306.6

Accessible means of egress required by Chapter 10 of the International Building Code are required to be added in existing facilities undergoing alterations. (True/False)

False.

IEBC 306.7.2

Power-operated swinging doors serving a LULA elevator must remain open for what minimum duration when activated?

20 seconds

408.3.2.2

What is the maximum outside diameter permitted for a handrail with a circular cross section?

2 inches (51 mm)

505.7.1

A sign containing raised characters and braille must have a clear floor area centered on the raised characters of what minimum dimension?

18 inches (455 mm) by 18 inches (455 mm)

703.3.11

Objects on multiple posts or pylons, where the clear distance between posts is greater than 12 inches (305 mm), must have the lowest edge at what height range?

27 inches maximum or 80 inches minimum above the floor

307.3

What is the minimum required space between the grab bar gripping surface and the adjacent wall?

1 1/2 inches (38 mm)

609.3

In Type B units, for the maneuvering clearance at swinging doors for the front approach direction on the push side, what is the minimum required dimension perpendicular to the door?

48 inches (1220 mm)

1104.5.1 Exception

What is the minimum required width for an access aisle serving car and van parking spaces?

60 inches (1525 mm)

502.4.2

Where clocks are provided for public use and installed overhead, the numerals and digits must be visual characters complying with which section?

Section 703.2

805.8

In Type B units utilizing Option A, where a vanity overlaps the required water closet clearance, what is the maximum permissible depth of the vanity, measured perpendicular from the rear wall?

24 inches (610 mm)

1104.11.3.1.2.2.4

For on-street perpendicular or angled accessible parking spaces, what is the minimum required width for the access aisle?

96 inches (2440 mm)

502.9.2

Benches primarily for children’s use are permitted to have a seat height within what range above the floor?

11 inches (280 mm) minimum and 17 inches (430 mm) maximum

903.6 Ex.

In an elevator, the raised character and braille floor designations must be placed immediately to the left of the control button, and the number zero (0) shall designate which floor?

The main entry floor

407.4.7.1.2, 407.4.7.1.3

The minimum width required for both toe clearance and knee clearance is:

30 inches (760 mm)

306.2.5, 306.3.5

If a clear floor space is confined in an alcove and positioned for a forward approach, the alcove must be 36 inches (915 mm) minimum in width where the depth exceeds what dimension?

24 inches (610 mm)

305.7.2

In existing buildings and facilities, what is the minimum required length and width for a clear floor space?

48 inches long and 30 inches wide

305.3.2

For an LULA (Limited-Use/Limited-Application) elevator utilizing swinging hoistway doors, what operation is required, and which standard must they comply with?

Power-operated, complying with ANSI/BHMA A156.19

408.3.2.1

Where Accessible, Type A or Type B units are being altered or added within an existing building, the number of required units shall be determined in accordance with which sections?

Sections 306.7.11.1 through 306.7.11.3.

IEBC 306.7.11

Incremental volume controls on volume-controlled telephones shall provide at least one intermediate step of gain of what minimum value?

12 dB

704.3

In Type A kitchen work areas, what is the minimum required clearance between opposing base cabinets, countertops, appliances, or walls?

40 inches (1015 mm)

1103.12.1.1

For dining surfaces and work surfaces primarily for children’s use, what minimum knee clearance height above the floor is permitted as an exception to Section 306?

24 inches (610 mm)

902.5.1 Ex.

In interior locations, detectable warning surfaces must differ from adjoining walking surfaces in resiliency or what other characteristic?

Sound-on-cane contact

705.4

Handrails shall be continuous within the full length of each stair flight or ramp run. Which type of handrail must be continuous between flights or runs?

Inside handrails on switchback or dogleg stairs or ramps

505.3

The audio output from an internal speaker of an Infrared Audible Sign Receiver shall be what minimum sound level at 18 inches (455 mm)?

75 dBA

703.8.3.3

Altered areas limited to which type of unit are exempt from the requirement to upgrade the accessible route, toilet facilities, and drinking fountains serving an area of primary function?

Type B dwelling and sleeping units.

IEBC 306.7.1, Exception 5

Where a parallel approach is provided to a wheelchair accessible public telephone, what is the maximum distance permitted from the edge of the telephone enclosure to the face of the telephone?

10 inches (255 mm)

704.2.1.1

The height of the pool lift seat, when in the raised position, shall be designed to allow a stop within what deck-to-seat height range?

16 inches (405 mm) minimum and 19 inches (485 mm) maximum

1009.2.4

On a golf hole with three or more teeing grounds, which teeing ground, in addition to the second required teeing ground, must be designed for golf car entry and exit?

The teeing ground closest to the hole

1006.2.1

If a sales and service counter utilizes a forward approach, what is the minimum required length of the accessible portion of the counter surface?

30 inches (760 mm)

904.3.3

For a Type B refrigerator/freezer where the clear floor space is positioned for a parallel approach, what is the maximum offset permitted from the centerline of the appliance to the centerline of the clear floor space?

24 inches (610 mm)

1104.12.2.5.3

Accessible vehicle spaces serving electrical vehicle charging stations must have an adjoining access aisle that is what minimum width?

60 inches (1525 mm)

1107.2.2

Where spas, cold baths, or hot tubs are clustered at a single location, at least 5 percent, but not less than one of each type in each cluster, shall be accessible. Which specific recreational features are included in this clustering requirement?

Spas, cold baths, or hot tubs

1111.4.14

What is the maximum reach height permitted for hand operated controls on hand dryers serving lavatories, where the reach depth is 5 inches (125 mm)?

42 inches (1065 mm)

603.6

In motion picture viewing spaces, wheelchair space locations shall be located within the area of an auditorium in which the vertical viewing angles, as measured to the top of the screen, are from the 40th percentile to what maximum percentile of vertical viewing angles for all seats?

100th percentile

802.10.4.2

In a Type A unit, if a bottom-hinged oven door is provided, where must a countertop be positioned?

Adjacent to one side of the door

1103.12.5.5.3

On accessible routes located on the playing surfaces of miniature golf holes, what is the maximum slope permitted for a curb where the route intersects the playing surface?

1 inch (25 mm) maximum height

1007.2

For a required accessible means of egress, which component is explicitly NOT listed as a component of the continuous accessible route?

Escalators or Moving Walks

1009.2

In Type A kitchens, where a side-hinged door oven is provided, where must a countertop be positioned?

Adjacent to the latch side of the oven door

1103.12.5.5.2

Displays and information on accessible parking meters and pay stations must be visible from a point located what maximum height above the center of the clear space in front of the station?

40 inches (1015 mm)

502.10.2

If an elevator car has a centered door location, what is the minimum required door clear opening width?

42 inches (1065 mm)

407.4.1

In detention and correctional facilities, signs identifying permanent rooms and spaces are not required to comply with visual characters, raised characters, and braille provisions if they are located where?

Not located in public areas

1112.6

If spectators in front of the wheelchair space locations are expected to stand at their seats for purposes of viewing events, the line of sight must comply with which section?

Section 802.9.2

802.9

In structures intended to be occupied as a residence, how many dwelling units or sleeping units must be present in a single structure before every unit is required to be a Type B unit?

Four or more

1108.6.2.2.2

In Type B units, for an accessible route making a 180-degree turn around an object less than 48 inches (1220 mm) wide, what is the minimum clear width required during the turn?

48 inches (1220 mm)

1104.4.1 Exception

What is prohibited under the exposed portions of dining surfaces and work surfaces?

Sharp or abrasive surfaces

902.3

Walking surfaces that are part of an accessible route within Accessible units shall comply with which section of the code?

Section 403

1102.4

In Type B units using Option A, where a forward approach is provided to the water closet, what is the minimum required clearance depth from the rear wall?

66 inches (1675 mm)

1104.11.3.1.2.2.3

The accessible route from any separate-sex toilet room to a family or assisted-use toilet room shall not exceed what maximum travel distance?

500 feet (152 m)

1110.2.1.4

What is the minimum and maximum height range for amusement ride transfer devices and seats designed for transfer, measured from the surface of the load and unload area?

14 inches (355 mm) minimum and 24 inches (610 mm) maximum

1002.5.2

For an assembly area with 5,001 seats, what is the minimum required number of wheelchair space locations?

7

802.10, Table 802.10

Where accessible routes pass through parking facilities, what measure must be taken unless an exception applies?

They shall be physically separated from vehicular traffic

507.1

In general, doors shall not swing into the clear floor space or clearance for any fixture in a toilet or bathing room. Which situation is NOT an exception to this rule?

Multiuser toilet room with three or more fixtures

603.2.2

For a standard accessible lavatory, what type of approach must be provided for the clear floor space?

Forward approach

606.2

Grab bars with a circular cross section shall have an outside diameter within what size range?

1 1/4 inch (32 mm) minimum and 2 inches (51 mm) maximum

609.2.1

What protection must be provided for water supply and drainpipes exposed beneath lavatories and sinks?

Insulated or otherwise configured to protect against contact

606.6

In Accessible units, what compliance requirement applies to user controls for security or intercom systems?

Shall comply with Section 309

1102.9

In new buildings (T-shaped turning space, Option 1), the required T-space must fit within an area that is 68 inches wide and what minimum depth?

60 inches (1525 mm)

304.3.2.1

Braille provided on elevator car controls shall be separated what minimum distance from the corresponding raised characters or symbols?

3/16 inch (4.8 mm)

703.4.4

In Type B units utilizing Option A, a bathtub with a parallel approach requires a clearance of 60 inches minimum in length and 30 inches minimum in width. What fixture is specifically permitted to be located in this clearance area?

A lavatory complying with Section 606

1104.11.3.1.3.1

For gangways, floating piers, and transition plates that are part of accessible routes, how shall the cross slope specified in Sections 403.3 and 405.3 be measured?

In the static position

1003.2.1

The tops of standard accessible dining surfaces and work surfaces shall be located within what height range above the floor?

28 inches (710 mm) minimum and 34 inches (865 mm) maximum

902.4

Where the bottom grade break of a perpendicular curb ramp is behind the back of curb by more than 60 inches (1525 mm), where shall the detectable warning surface be placed?

On the lower landing at the back of curb

705.7.1

In new buildings, what is the maximum interval at which passing spaces must be provided if the accessible route has a clear width less than 60 inches (1525 mm)?

200 feet (61 m)

403.5.4.1

In Accessible units, if toilet and bathing facilities are not required to comply with Section 1102.11.2, reinforcement for future installation of grab bars and shower seats shall be provided in accordance with which section?

Section 1104.11.1

1102.11.1

The signal-to-noise ratio for internally generated noise in assistive listening systems shall be what minimum value?

18 dB

706.6

On the push side, door surfaces must be smooth for the full width of the door or gate and extend up from the floor for a minimum of what distance?

10 inches (255 mm)

404.2.9

What is the maximum height permitted for the checkout counter surface above the floor?

38 inches (965 mm)

904.4.2

Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with the variable message sign requirements of ICC A117.1, unless what is provided?

Equivalent information in an audible manner

1112.5.2

At least what minimum percentage of care recipient and visitor parking spaces provided to serve hospital outpatient facilities shall be accessible?

10 percent

1106.4

Self-service shelves and dispensing devices in food service lines shall comply with which section governing reach ranges?

Section 308

904.5.1

Parking spaces and access aisles must have floor surfaces that comply with Section 302 and have surface slopes not steeper than what ratio?

1:48

502.5

Accessible dining surfaces and work surfaces primarily for children ages 5 and younger are exempt from complying with Section 902.5, provided they have a clear floor space positioned for which approach?

Parallel approach

902.5 Ex.

The top of handrail gripping surfaces on ramps connecting elevated play components shall be what maximum height above the ramp surface?

28 inches (710 mm)

1008.4.1.2.3.2

Stairways that are part of the means of egress for an exterior area for assisted rescue must provide a minimum clear width between handrails of:

48 inches (1219 mm)

1009.7.4

Per Figure 105.4, what does a dashed line of short dashes represent?

Boundary of clear floor space or maneuvering clearance

105.4

What must the administrative authority provide to specify the extent to which the technical criteria of this standard apply?

Scoping provisions

201

If an alternative accessible bathing room is provided due to technical infeasibility, it must be located:

On the same floor and in the same area as the existing bathing rooms.

IEBC 306.7.13

Where receipts are provided by an ATM, the speech output devices must provide audible information for which items?

Audible balance inquiry information, error messages, and all other information necessary to complete or verify the transaction

707.8.2

What is the maximum operating force permitted for a horizontal or vertical sliding operable window?

8.5 pounds (37.7 N)

506.2

In new buildings and facilities, what is the minimum required width for an access aisle serving a passenger loading zone vehicle pull-up space?

67 inches (1700 mm)

503.3.2.1

In Type A units, if an accessible work surface is adjustable, what is the maximum height above the floor permitted?

36 inches (915 mm)

1103.12.3.2 Exception

If vanity countertop space is provided in Accessible units, what measurement criteria must it meet relative to the lavatory?

It must be equivalent in size and proximity to the lavatory as provided in non-Accessible units

1102.11.2.1

Where an alteration affects the accessibility to, or contains an area of, primary function, which element is required to be made accessible, in addition to the route to the primary function area?

Toilet facilities and drinking fountains serving the area of primary function.

IEBC 306.7.1

In units with accessible communication features, if unit smoke detection is provided, it must include what type of notification complying with NFPA 72?

Audible

1106.2

Spaces and elements within employee work areas are required to comply with Sections 907.5.2.3.1, 1009, 1104.3.1, and what additional requirement?

Be designed so individuals with disabilities can approach, enter, and exit the work area.

1103.2.2

In a new building, if the clear width of an interior accessible route is reduced to 32 inches (815 mm) minimum, what is the maximum length of this reduced-width segment?

24 inches (610 mm)

403.5.1

In new buildings, where an accessible route makes a 180-degree turn around an object less than 52 inches wide, what is the minimum required width during the turn if the approaching and leaving widths are 36 inches minimum?

60 inches (1525 mm)

403.5.2.1

Type B dwelling or sleeping units are NOT required in existing buildings undergoing alterations where the work area is what percentage or less of the aggregate area of the building?

50 percent.

IEBC 306.7.4

What is the minimum clear opening required for doorways in Type C (Visitable) Units?

31 3/4 inches (805 mm)

1105.5.3.1

What is the minimum length required for a transfer wall?

60 inches (1525 mm)

1009.4.3

In historic buildings where bathing rooms are provided, what is the minimum required accessible facility?

Not fewer than one accessible single-user bathing room or one accessible family or assisted-use bathing room.

IEBC 306.7.18.5

Projections into the clear opening width of a doorway between 34 inches and 80 inches above the floor shall not exceed what maximum dimension?

4 inches (100 mm)

404.2.2

For a forward approach counter, what is the maximum height permitted for the accessible counter surface above the floor?

36 inches (915 mm)

904.3.3

An accessible route is not required to connect stories, mezzanines, and occupiable roofs that have an aggregate area of not more than 3,000 square feet and are located above and below accessible levels. This exception does NOT apply to which occupancy?

Passenger transportation facilities and airports (Group A-3 or B).

1104.4

An area of refuge is NOT required at an elevator that is part of an accessible means of egress if the elevator is serving which specific facility type?

Open parking garages

1009.4.2, Exception 1

In existing buildings, a T-shaped turning space shall fit within what minimum square dimension?

60 inches (1525 mm)

304.3.2.2

What is the minimum required clear space that must be provided beyond the bottom grade break of a curb ramp, located within the pedestrian street crossing and outside the parallel vehicle travel lane?

48 inches (1220 mm) by 48 inches (1220 mm)

406.5.5

According to Table 1109.2.2.1, an assembly area with 3,000 fixed seats requires how many minimum required wheelchair spaces?

22

1109.2.2.1, Table 1109.2.2.1

1 / 870