For foam plastic interior trim, the flame spread index shall not exceed 75, and the smoke-developed index shall not be limited, unless the material is tested in accordance with which alternative standard?

NFPA 286

2604.2.4 Exception

What is the required minimum thickness for an Artificial Barricade designed to shield from explosive materials?

3 feet (914 mm)

202 [F] Artificial Barricade

Any person who commences work before obtaining necessary permits shall be subject to a fee established by the building official that shall be:

In addition to the required permit fees

109.4

What is the maximum encroachment permitted for vestibules and storm enclosures?

Not encroach more than 3 feet (914 mm).

3202.4

For soils to be considered expansive, they must have a Plasticity Index (PI) of 15 or greater, and more than what minimum percentage of the soil particles must pass a No. 200 sieve (75 µm)?

10 percent

1803.5.3 Item 2

For structures assigned to Seismic Design Category B or C, if a response modification coefficient, R, in accordance with ASCE 7, Table 12.2-1, is used, the structures must be designed and detailed in accordance with the requirements of which standard?

AISC 341

2202.2.1.1

The building official is authorized to grant extensions of time for a permit application abandonment period for additional periods not exceeding:

90 days each

105.3.2

In addition to the primary inflation system, an auxiliary inflation system must be provided in air-supported and air-inflated structures larger than what minimum area?

1,500 square feet (140 m2).

3102.8.1.1

The screen or chimney cap of a spark arrestor must be removable to allow for:

cleaning of the chimney flue

2113.9.2 Item 4

Engineering analysis to determine fire protection time for connections in fire-resistance-rated members must demonstrate that the average temperature rise at any portion of the connection is limited to what maximum value?

250°F (139°C)

2304.10.1

Construction materials and equipment shall not be placed or stored so as to obstruct access to fire hydrants, standpipes, or within what maximum distance of a street intersection?

20 feet (6096 mm)

3308.1.1

For glazing in windows to be a hazardous location (Section 2406.4.3), one or more walking surface(s) must be within what maximum horizontal distance of the plane of the glazing?

36 inches (914 mm).

2406.4.3

Where an elevator is installed in a single blind hoistway or on the outside of a building, what must be installed in the blind portion of the hoistway or blank face of the building?

An emergency door in accordance with ASME A17.1/CSA B44

3002.5

Gypsum wallboard or gypsum plaster shall not be used in any exterior surface where such gypsum construction will be exposed directly to the weather, nor shall gypsum wallboard be used where there will be direct exposure to water or continuous:

high humidity conditions.

2508.2

Rectangular chimney flues serving fireplaces with an aspect ratio of 2 to 1 or more shall have a minimum net cross-sectional area of not less than what minimum fraction of the fireplace opening?

1/8

2113.16.1

If walls and partitions separating sleeping units are field tested for airborne noise in accordance with ASTM E336, they must have a Normalized Noise Isolation Class (NNIC) rating of not less than:

45

1206.2

Where a covered or open mall building utilizes the reduced open space exception (40 feet), for what maximum percentage of the perimeter is the reduction allowed?

75 percent

402.2 Exception

The exterior air outlet for a masonry fireplace is permitted to be located in the back or sides of the firebox chamber or within what maximum distance of the firebox opening on or near the floor?

24 inches (610 mm)

2111.14.6

The identification signs or stenciling for fire walls in accessible concealed spaces must be located within 15 feet (4572 mm) of the end of each wall and at intervals not exceeding what maximum distance measured horizontally along the wall?

30 feet (9144 mm)

703.5

In buildings required to have standpipes by Section 905.3.1, when must they be installed prior to construction?

Prior to construction exceeding 40 feet (12 192 mm) in height

3311.1

In Group R-3 occupancies (and R-2 dwelling units not required to be accessible), the maximum stair riser height shall be:

7 3/4 inches (197 mm)

1011.5.2 Exception 3

According to Table 1807.1.6.2, for a 7-foot maximum wall height, 7-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft, what is the minimum vertical reinforcement required for a 7.5-inch minimum wall thickness?

#6 at 48 inches

1807.1.6.2

Exterior Insulation and Finish Systems (EIFS) with drainage is required on framed walls of Type V construction serving which occupancy groups?

Group R1, R2, R3, and R4

1407.4.1

Masonry chimney walls shall be constructed of concrete, solid masonry units, or hollow masonry units grouted solid with not less than what nominal thickness?

4 inches (102 mm)

2113.1

Doors opening onto a ramp landing shall not reduce the clear width to less than:

42 inches (1067 mm)

1012.5.3

In buildings of Type I or II construction, thermal and acoustical insulation, other than foam plastics, must have a maximum flame spread index of:

25

603.1

Fabric partitions that exceed 6 feet in height shall resist a concentrated load of 40 pounds applied to an 8-inch-diameter area at a height of:

54 inches (1372 mm)

1607.16.1

Steel fireplace units incorporating a steel firebox lining must be constructed with steel not less than what minimum thickness?

1/4 inch (6.4 mm)

2111.6.1

For fire-resistant joint systems protecting joints in smoke barriers, the L rating of the system must not exceed what value per linear foot of joint at 0.30 inch of water (74.7 Pa) for both ambient and elevated temperature tests?

5 cubic feet per minute

715.9

For detailed plain concrete structural walls, continuous vertical reinforcement must be provided at each corner, at each side of each opening, and at the ends of walls, with a cross-sectional area of not less than:

0.20 square inch (129 mm2)

1905.5.1

Beam-to-column moment connections in structural steel special moment frames and intermediate moment frames must be prequalified in accordance with AISC 341, Section K1, qualified by testing in accordance with AISC 341, Section K2, or shall be prequalified in accordance with which standard?

AISC 358

2202.2.1.1, 2202.2.1.2

Which of the following is listed as a special consideration that must be indicated on the construction documents for steel joists?

Oversized or other nonstandard web openings

2207.2 Item 2.2

Swimming pools, wading pools, cold baths, hot tubs and spas shall be accessible and be on an accessible route, EXCEPT that where spas, cold baths or hot tubs are clustered at a single location, at least 5 percent, but not less than one of each type in each cluster, shall be:

accessible and be on an accessible route

1111.4.14 Exception 2

A passenger loading zone shall be provided at an accessible entrance to licensed medical and long-term care facilities where the period of stay exceeds:

24 hours

1106.9.2

Where accessible parking is provided for a parking facility providing 1,500 total parking spaces, how many accessible spaces are required?

25

Table 1106.2

In corridors and smoke barriers, a 20-minute fire door assembly required to have a minimum fire protection rating of 20 minutes shall be tested in accordance with NFPA 252 or UL 10C without which test?

Hose stream test

716.2.2.1

Lightning protection systems must be installed in accordance with NFPA 780 or which UL standard?

UL 96A

2703.2

Plaster applied to adobe masonry must be not less than 7/8 inch (22 mm) and not greater than what maximum thickness?

2 inches (51 mm)

2109.2.4.8.3

In exterior walls requiring a 2-hour fire-resistance rating, what is the minimum required fire window assembly rating?

1 1/2 hours

Table 716.1(3)

Which two occupancy types are generally exempt from Chapter 11 requirements for detached dwellings and their accessory structures?

One- and two-family dwellings (R-3)

1103.2.3

According to Table 1705.3, inspecting the erection of precast concrete members requires which type of inspection?

Periodic special inspection.

Table 1705.3 Item 10

Portland cement grouts used for ceramic tile installation must comply with which ANSI standard?

ANSI A118.6

2103.2.3.7

Where uplift is due to wind or seismic loading, the minimum factor of safety is permitted to be reduced to one and one-half where capacity is determined by:

load tests

1810.3.3.1.5 Exception

Freestanding parking garages not providing means of egress for buildings or structures assigned to a higher risk category shall be assigned to which risk category?

Risk Category II

1604.5 Exception 2

An attached top rail is not required for guards with structural glass balusters if the baluster panels are laminated glass meeting certain conditions and tested to remain in place as a barrier following impact or glass breakage in accordance with which ASTM standard?

ASTM E2353.

2407.1.2

The reference plane representing the average of finished ground level adjoining the building at exterior walls is the:

Grade Plane

202 [BG] Grade Plane

In conventional light-frame construction, foundation sill plates must be bolted or anchored to the foundation with bolts spaced not more than what maximum distance on center?

6 feet (1829 mm)

2308.7.1

Fractional numbers resulting from applying the fixture ratios of Table 2902.1 shall be handled by rounding how?

Rounded up to the next whole number

2902.1.1

What is the minimum corridor width (in inches) required in Group I-2 in areas where required for bed movement?

96

Table 1020.2

According to Table 2103.2.3, what is the composition requirement for the scratchcoat mortar used for ceramic tile walls?

1 cement; 1/5 hydrated lime; 4 dry or 5 damp sand

2103.2.3

Which concrete element is exempt from special inspections and tests if the effective prestress in the concrete is less than 150 psi (1.03 MPa)?

Nonstructural concrete slabs supported directly on the ground.

1705.3 Exception 3

Where drinking fountains are provided, one drinking fountain shall comply with the requirements for people who use a wheelchair and one shall comply with the requirements for:

standing persons

1110.7.1

The aggregate floor area of Group H occupancies located in an unlimited area building shall not exceed what maximum percentage of the area of the building?

10 percent

507.8.1

For delayed egress systems (Section 1010.2.12), an attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds, EXCEPT where approved, a delay of not more than what maximum duration is permitted?

30 seconds

1010.2.12.1 Item 4 Exception

For Type VB construction, openings in exterior walls not required to be protected by Section 705 may be glazed with light-transmitting plastic provided it complies with which section?

Section 2606

2608.1

The landing length for means of egress ramps shall be what minimum distance?

60 inches (1525 mm)

1012.6.3

Foam plastic up to 10 inches thick in cooler and freezer walls must be covered by corrosion-resistant steel having a minimum base metal thickness of not less than:

0.0160 inch (0.4 mm)

2603.4.1.2

On a site with multiple nonelevator buildings, the required number of Type B units may be reduced to a percentage equal to the percentage of the entire site having grades, prior to development, that are less than 10 percent, provided that not less than what percentage of the required Type B units on the site are still provided?

20 percent

1108.7.4 Item 1

Where anchored terra cotta or ceramic veneer units are tied to the backing wall, the space between the facing and the backing wall must be set with not less than a 2-inch space and the space must be filled solidly with:

Portland cement grout and pea gravel

1404.1

For shakes and taper sawn shakes of naturally durable wood, the spacing between shakes in the same course shall be what maximum distance?

5/8 inch (15.9 mm)

1507.9.8

Continuous special inspections must be performed during the installation of helical pile foundations, and the information recorded must include installation equipment used, pile dimensions, tip elevations, final depth, and:

final installation torque.

1705.9

The building area of a covered mall building shall not be limited provided that the construction type is Type I, II, III, or IV and the building does not exceed:

Three stories above grade plane

402.4.1.1

The minimum nominal tensile strength for vertical ties within a bearing wall shall be equal to the weight of the wall within that story plus the weight of the diaphragm tributary to the wall in which story?

the story below

1616.3.2.4

Where provided, fire pump rooms and automatic sprinkler system riser rooms must be designed with sufficient working room to allow inspection, service, repair or replacement without removing:

Elements of permanent construction

902.1

Fire partitions serving as a corridor wall are permitted to terminate above the lower membrane of a corridor ceiling, provided the corridor ceiling membrane is equivalent to the corridor wall membrane and the building is equipped throughout with an automatic sprinkler system and sprinklers are installed in the space:

Between the top of the fire partition and underside of the floor or roof sheathing

708.4 Exception 2

Except for tempered spandrel glass, the permanent identification mark on tempered glass shall be of a type that, once applied, cannot be removed without being:

destroyed.

2403.1

What term is used for wood products that exhibit reduced surface-burning characteristics and resist propagation of fire after being impregnated with chemicals by a pressure process or other means?

Fire-Retardant-Treated Wood

202 [BS] Fire-Retardant-Treated Wood

According to Table 722.2.2.1, what is the minimum required slab thickness in inches for a 2-hour fire-resistance rating when using siliceous aggregate concrete?

5

Table 722.2.2.1

Underpinning must be installed in a sequential manner that protects the neighboring structure and the working construction site, and the sequence of installation must be identified in the:

approved construction documents

1804.2.1

The Building Area is the area included within surrounding exterior walls, or exterior walls and fire walls, exclusive of vent shafts and:

Courts

202 [BG] Area, Building

Soil classification for geotechnical investigations must be based on observation and any necessary tests of materials disclosed by borings, test pits, or other subsurface exploration, and rock must be classified in accordance with which ASTM standard?

ASTM D5878

1803.3

For vinyl siding attached to wood construction, nails used to fasten the siding and accessories must be corrosion resistant, and penetration into nailable substrate shall be not less than:

1 1/4 inches (32 mm)

1404.15.1.1

The minimum thickness of hearth extensions shall be:

2 inches (51 mm)

2111.10.2

In Climate Zones 6, 7, and 8, upper ventilators that provide the reduced net free cross-ventilation area must be located not more than what distance below the ridge?

3 feet (914 mm)

1202.2.1 Exception

In Group E occupancies, an adult changing station is required where a room or space used for assembly purposes requires an aggregate of how many or more male and female water closets for that room or space?

six

1110.4.1 Item 3

For library stack rooms designed using the load specified in Table 1607.1, the nominal shelf depth shall not exceed what maximum dimension for each face?

12 inches (305 mm)

1607.17

Mineral-surfaced roll roofing shall not be applied on roof slopes below what minimum units vertical in 12 units horizontal?

1 unit

1507.6.2

Emergency escape and rescue openings shall be provided in basements and sleeping rooms below which story above grade plane?

the fourth story above grade plane

1031.2

Compliance with drainage requirements is not necessary for an exterior wall assembly tested to resist wind-driven rain if the test is conducted in accordance with ASTM E331 at a minimum differential pressure of:

6.24 pounds per square foot

1402.2

For high-rise buildings not greater than 420 feet (128 m) in height, the fire-resistance rating of columns supporting floors in Type IA construction shall be reduced to:

Not permitted to be reduced

403.2.1.1 Exception

What is the maximum height or thickness of a marquee if it projects more than two-thirds of the distance from the lot line to the curb line?

Not greater than 3 feet (914 mm).

3106.2

Unit skylights and tubular daylighting devices must be tested and labeled as complying with which standard?

AAMA/WDMA/CSA 101/I.S./A440.

2405.5

The walls of one-story adobe buildings must be laterally supported at intervals not exceeding:

24 feet (7315 mm)

2109.2.4.4

What is the minimum critical radiant flux classification required for interior floor finish materials in corridors in a Group I-2 occupancy?

Class I

804.4.2

In Group R-2 dormitories, within sleeping units and dwelling units that are equipped throughout with an automatic sprinkler system, the permissible amount of combustible decorative materials suspended from walls shall not exceed what percentage of the aggregate wall areas?

50 percent

806.2 Exception 2

Structures assigned to Seismic Design Category D, E or F must be designed and detailed in accordance with which standard, except as permitted in ASCE 7, Table 15.4-1?

AISC 341

2202.2.1.2

Class B materials shall be permitted as wainscotting extending not more than what distance above the finished floor in corridors and exit access stairways and ramps?

48 inches (1220 mm)

Table 803.13 Note j

For clay and concrete tile valley flashing, the valley flashing shall extend not less than what minimum distance from the centerline each way?

11 inches (279 mm)

1507.3.9

For public-occupancy temporary structures, where controlled occupancy procedures are implemented due to expected snow, the ground snow load reduction factor is permitted to be modified to what value?

0.65.

3103.6.1.1 Exception

The minimum width for exit passageways serving an occupant load of less than 50 shall be not less than:

36 inches (914 mm)

1024.2

At least what percentage of holes on miniature golf courses shall be accessible?

50 percent

1111.4.12.1

For structures with a maximum plan dimension not more than 50 feet, continuous foundations are required at which locations?

Exterior walls only

2308.10.8.1

Glass in vision panels in elevator hoistway doors must be any transparent glazing material not less than what minimum thickness?

1/4 inch (6.4 mm).

2409.3

In vehicle and pedestrian traffic areas of motor-vehicle-related occupancies, the clear height of each floor level shall be not less than:

7 feet (2134 mm)

406.2.2

Wood walls and bearing partitions shall not support more than two floors and a roof unless an analysis satisfactory to the building official demonstrates that the resulting wood shrinkage will not have adverse effects on the structure or associated systems.

Two floors and a roof

2304.3.3

Where a lining is not provided in a masonry firebox, the total minimum thickness of back and sidewalls shall be:

10 inches (254 mm) of solid masonry

2111.6

Where required, an ice barrier shall extend from the lowest edges of all roof surfaces to a point not less than what minimum distance inside the exterior wall line of the building?

24 inches (610 mm)

1507.1.2

Emergency and standby power systems must be maintained and tested in accordance with which code?

International Fire Code

2702.4

As an option for smoke removal in high-rise buildings, mechanical air-handling equipment must provide one exhaust air change every:

15 minutes

403.4.7

Built-up, modified bitumen, single-ply roof systems, metal panel roof systems applied to a solid deck, and other membrane roof coverings shall be tested in accordance with FM 4474, UL 580 or:

UL 1897

1504.4.1

The aggregate clear egress width of the mall in a covered or open mall building shall be not less than:

20 feet (6096 mm)

402.8.1.1

According to Table 3306.1, if the construction height is 8 feet or less and the distance to the lot line is 5 feet or more, what type of protection is required?

None

Table 3306.1

Gypsum panel products shall not be used in diaphragm ceilings to resist lateral forces imposed by which types of construction?

Masonry or concrete construction

2508.6.5

Walls and partitions within 2 feet (610 mm) of service sinks, urinals and water closets must have a smooth, hard, nonabsorbent surface to a height of not less than what minimum distance above the floor?

4 feet (1219 mm)

1210.2.2

Equipment platforms shall NOT serve as part of the means of egress from the building, and their area shall NOT be included in determining the:

Fire area in accordance with Section 903

505.3

If a room in a building has a sloped ceiling, any portion of the room measuring less than what distance from the finished floor to the ceiling shall not be included in any computation of the minimum area?

5 feet (1524 mm)

1208.2 Exception 2

The board of appeals shall not have the authority to:

Waive requirements of this code

113.2

For compliance with Tables 1404.3(3) and 1404.3(4), spray foam with a maximum permeance of 1.5 perms at the installed thickness is deemed to meet the continuous insulation moisture control requirement if the spray foam R-value meets or exceeds the specified continuous insulation R-value, OR if the combined R-value of the spray foam and continuous insulation is equal to or greater than the specified:

continuous insulation R-value

1404.3.1

Screens used for broken glass retention shall be constructed of a noncombustible material not thinner than No. 12 B&S gage (0.0808 inch) with mesh not larger than:

1 inch by 1 inch (25 mm by 25 mm).

2405.3

For posts embedded in earth and not embedded in poured footings, backfill in the annular space is permitted to be clean sand, thoroughly compacted by tamping in layers not more than what maximum depth?

8 inches (203 mm)

1807.3.3 Item 2

For a through penetration firestop system in a fire-resistance-rated wall, the system must have an F rating of not less than:

The required fire-resistance rating of the wall penetrated

714.4.1.2

Reports of mill tests are required for reinforcing bars complying with ASTM A615 and used to resist earthquake-induced forces in seismic force-resisting systems in structures assigned to which Seismic Design Categories?

B, C, D, E or F.

1704.5 Item 7

For statically loaded components where load test procedures are not specified, the test load shall be left in place for a period of:

24 hours.

1708.2.2

Where elevator hoistway door protection is required, what is the height measurement requirement for a high rise hoistway?

From the lowest floor to the highest floor of the floors served by the hoistway

3006.2

Unlimited unprotected openings are permitted in the first story above grade plane where the exterior wall faces an unoccupied space that is not less than what minimum width?

30 feet (9144 mm)

705.9.1 Exception 1

What is the minimum required fire-resistance rating in hours for a fire wall separating Group H-1 and H-2 occupancies?

4 hours

Table 706.4

Basements need not be included in the total allowable floor area of a building, provided the total area of such basements does not exceed the area permitted for a building with a maximum of:

One story above grade plane

506.1.3

Escalators and moving walks must be constructed of which materials, with exceptions for certain components?

Approved noncombustible and fire-retardant materials

3004.2

What type of communication system is required in each elevator car?

An emergency two-way communication system with both visual and audible modes

3001.2

For structures under construction, alteration or demolition, what is the minimum hazard classification required for the sizing of portable fire extinguishers?

Ordinary hazard

3309.1

What two types of notification appliances must be installed within each occupant evacuation elevator lobby?

One audible and one visible notification appliance

3008.9.1

Educational occupancies for students above the 12th grade, including higher education laboratories, are classified as which occupancy group?

Group B

304.1

An accessible route is not required to press boxes in bleachers that have a single point of entry from the bleachers, provided that the aggregate area of all press boxes for each playing field is not more than:

500 square feet (46 m2)

1104.3.2 Exception 1

The maximum allowable quantity for use in closed systems of Flammable Solid (solid) per control area is:

125 pounds (NA)

Table 307.1(1)

Any fire protection or life safety system installed but not required by this code must still meet the requirements of this code, provided that such system is installed for:

Partial or complete protection

901.2 Exception

The maximum allowable quantity for storage of Cryogenic Flammable (liquid) per control area is:

45 gallons

Table 307.1(1)

Dampproofing materials for walls must be installed on the exterior surface of the wall, and shall extend from the top of the footing to:

above ground level.

1805.2.2

Round chimney flues serving fireplaces must have a minimum net cross-sectional area of not less than what minimum fraction of the fireplace opening?

1/12

2113.16.1

Specific information, such as test reports conducted by an approved agency, must be provided for the building official to determine that the product, material or assembly meets the applicable:

code requirements.

1703.4

The approved agency shall periodically perform an inspection (in-plant if necessary) to verify that the labeled product, material or assembly is representative of the:

product, material or assembly tested.

1703.5.2

A masonry heater must be designed to route exhaust gases through internal heat exchange channels where the flow path downstream of the firebox includes flow in either a horizontal or downward direction before entering the:

chimney

2112.1

Where separate central holding cells are provided for adult males, juvenile males, adult females or juvenile females, how many of each type shall be accessible?

one of each type

1109.4.2.1

For polypropylene siding fasteners, where the nail fully penetrates the sheathing or nailable substrate, the end of the fastener shall extend not less than what minimum distance beyond the opposite face?

1/4 inch (6.4 mm)

1404.18.2

For rows of seating served by aisles or doorways at both ends, where seats have backrests, the row length limit for a minimum 12-inch clear width aisle accessway shall be increased by 0.3 inch (7.6 mm) for every additional seat beyond how many seats?

14 seats

1030.13.2.1

Power-operated conveyors, belts, and other material-moving devices must be equipped with what automatic mechanism?

Automatic limit switches to shut off power and stop operation

3004.3.2

What is the minimum required fire-resistance rating in hours for exterior bearing walls in Type IV-C construction?

2

Table 601

Where two or more exits or access to exits are required, not more than what fraction of the exits or exit access doorways shall be equipped with horizontal sliding or vertical security grilles?

one-half

1010.3.4

The design and installation of stairs, ladders, and guarding serving steel storage racks and industrial steel work platforms must be in accordance with which standard?

ANSI/MH 32.1

2213.1

Interior adhered masonry veneers shall have a maximum weight of 20 pounds per square foot, and where supported by wood construction, the supporting members shall be designed to limit deflection to what maximum fraction of the span?

1/600

1404.11.3

Wood shakes shall only be used on slopes of not less than what minimum units vertical in 12 units horizontal?

4 units

1507.9.2

The truss design drawings for cold-formed steel trusses must conform to the requirements of Section I1 of which standard?

AISI S202

2206.1.3.1

The capacity, in inches, of means of egress components other than stairways shall be calculated by multiplying the occupant load served by a capacity factor of 0.2 inch (5.1 mm) per occupant, EXCEPT that in sprinklered buildings (other than Group H and I-2), the factor is reduced to:

0.15 inch (3.8 mm) per occupant

1005.3.2 Exception 1

For roof live load reduction factor, the value is 1 for a tributary area less than or equal to:

200 square feet (18.58 m2)

1607.14.1

The combustion air passageway for masonry fireplaces shall be not less than 6 square inches (3870 mm2) and not more than what maximum area?

55 square inches (0.035 m2)

2111.14.5

Projections extending to 5 feet (1524 mm) or less from the line used to determine the fire separation distance shall be constructed of combustible materials of not less than:

1-hour fire-resistance-rated construction

705.2.3

Steel storage racks 8 feet in height or greater assigned to Seismic Design Category D, E or F require what type of inspection for storage rack anchorage installation?

Periodic inspection.

Table 1705.13.7 Item 3

Structures and tenant spaces intended for public utilization must provide public toilet facilities for which users?

Customers, patrons and visitors

2902.3

What is the minimum number of exits or access to exits required for a story or occupiable roof with an occupant load of 501 to 1,000?

3

Table 1006.3.3

Where Section 1705.12 specifies special inspection for wind resistance, the statement of special inspections must identify the wind-resisting components and the:

main windforce-resisting systems.

1704.3.3

A stairway considered part of an accessible means of egress must have a clear width of what minimum distance between handrails?

48 inches (1219 mm)

1009.3.2

The lettering size for permanent identification signs of fire barriers in concealed spaces must be not less than 3 inches (76 mm) in height with a minimum stroke of:

3/8 inch (9.5 mm)

703.5

Where exterior wall openings are required to be protected in accordance with Section 705, a light-transmitting plastic skylight shall not be installed within what maximum distance of such exterior wall?

6 feet (1829 mm)

2610.7

For vegetative and landscaped roofs, the weight of landscaping and hardscaping materials shall be computed considering both fully saturated soil and drainage layer materials and fully dry soil and drainage layer materials in order to determine the:

most severe load effects

1606.5

What is the maximum exit access travel distance permitted on a pedestrian walkway that is constructed with both sides not less than 50 percent open, and equipped throughout with an automatic sprinkler system?

400 feet (122 m) or less.

3104.9 Exception 3

In Group M occupancies, egress through stockrooms is permitted provided there is a demarcated, minimum 44-inch-wide (1118 mm) aisle defined by full- or partial-height fixed walls that leads directly from the retail area to the exit without:

Obstructions

1016.2 Item 2.4

Tanks having a capacity of more than what maximum volume located on the roof deck of a building shall be supported on masonry, reinforced concrete, steel or heavy timber construction?

500 gallons (1893 L)

1511.3

For buildings located in whole or in part in flood hazard areas, the flood documentation must include the elevation of the proposed lowest floor, referenced to the datum on the community’s Flood Insurance Rate Map (FIRM), for which areas?

Flood hazard areas other than coastal high hazard areas or coastal A zones

1603.1.7

Which standard governs the material for Nonasbestos fiber-cement backer board?

ASTM C1288 or ISO 8336, Category C

Table 2509.2

For pier and curtain wall foundations, the unsupported height of the masonry piers shall not exceed what maximum factor multiplied by their least dimension?

10 times

1809.10 Item 3.1

What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) Group H-1 occupancy of Type I A construction?

1

Table 504.4

The design and construction of buildings and structures located in flood hazard areas shall be in accordance with Chapter 5 of ASCE 7 and which other standard?

ASCE 24

1612.2

Elements or structures enclosing occupiable roof areas shall not extend more than what maximum distance above the surface of the occupiable roof?

48 inches (1220 mm)

503.1.4.1

Exterior decks, patios or balconies that are part of Type B units are exempt from accessible requirements if they have impervious surfaces and are not more than what maximum distance below the finished floor level of the adjacent interior space of the unit?

4 inches (102 mm)

1108.3 Exception 3

Where controlled occupancy procedures are implemented, the emergency action plan must document the criteria for initiating occupant evacuation procedures for which environmental events, where applicable?

Flood and tsunami events.

3103.8

Which professionals are permitted to act as special inspectors for the work designed by them, provided they qualify as special inspectors?

The registered design professional in responsible charge and engineers of record involved in the design.

1704.2.1

Unless otherwise indicated, foam plastic insulation must have a flame spread index of not more than 75 and a smoke-developed index of not more than what maximum value when tested in accordance with ASTM E84 or UL 723?

450

2603.3

The aggregate area limitations for light-transmitting plastic skylights can be increased by 100 percent if the building is equipped throughout with an automatic sprinkler system or if the building is equipped with what other life safety system?

smoke and heat vents in accordance with Section 910

2610.5 Exception

The concentrated live load given in Table 1607.1 shall be assumed to be uniformly distributed over an area of:

2 1/2 feet by 2 1/2 feet (762 mm by 762 mm)

1607.4

Flat or corrugated light-transmitting plastic skylights must slope not less than what minimum slope?

Four units vertical in 12 units horizontal (4:12)

2610.3

Installation of a skylight without a curb is permitted on roofs with a minimum slope of 14 degrees (three units vertical in 12 units horizontal) in which specific occupancy group?

Group R-3 occupancies.

2405.4

Foundation walls of rough or random rubble stone must be not less than what minimum thickness?

16 inches (406 mm)

1807.1.3

A Low Explosive material is characterized by a rate of reaction that is less than the speed of:

Fire spread

202 [F] Low Explosive

Where shallow foundations will bear on controlled low-strength material (CLSM), the geotechnical investigation must include specifications for the preparation of the site prior to placement of the CLSM and test methods to determine the compressive strength or:

bearing capacity of the CLSM.

1803.5.9

Public toilet facilities are not required for structures and tenant spaces intended for quick transactions (takeout, pickup, drop-off), provided the public access area is less than or equal to what maximum size?

300 square feet (28 m2)

2902.3 Exception

The inside height of the smoke chamber from the fireplace throat to the beginning of the flue shall be not greater than the:

inside width of the fireplace opening

2111.9.1

Where four or more elevator cars serve the same portion of a building, into how many separate fire-resistance-rated hoistways must the elevators be located?

Not fewer than two

3002.2

According to Table 1607.1, what is the minimum uniformly distributed live load required for a library reading room?

60 psf

1607.1

In Group H-2 and H-3 occupancies, not less than what percentage of the perimeter wall of the occupancy shall be an exterior wall?

25 percent

415.6

Ground-mounted photovoltaic panel systems are required to be designed and installed in accordance with Chapter 16 and which other code?

The International Fire Code.

3111.3.6

Loads and load combinations on storm shelters shall be determined in accordance with which standard?

ICC 500

1604.1

Rectangular tread depths shall be what minimum distance measured horizontally between the vertical planes of the foremost projection of adjacent treads?

11 inches (279 mm)

1011.5.2

Copies of necessary test and special inspection records must be filed with the:

building official.

1703.6.2

Mastic cement used to set thin exterior structural glass veneer shall be in sufficient quantity so that not less than 50 percent of the area of each glass unit is directly bonded by mastic not less than 1/4 inch thick and not more than what maximum thickness?

5/8 inch (15.9 mm)

1404.13.3

A child day care facility providing care for more than five but not more than 100 children 2½ years or less of age, where rooms have an exit door directly to the exterior, shall be classified as which group?

Group E

308.5.1

The airspace between a masonry chimney and combustibles must not be filled, except to provide fireblocking in accordance with:

Section 2113.20

2113.19

Glass fiber-reinforced concrete (GFRC) and its materials must be in accordance with which standard?

PCI 128

1903.2

According to Table 1507.9.8, what is the maximum weather exposure (in inches) permitted for 24-inch, Grade No. 1 taper sawn shakes of naturally durable wood installed on a 4:12 pitch or steeper?

10

1507.9.8

Where required for aggregate-surfaced roofs, the minimum parapet height shall be determined based on each roof surface elevation, and at no point shall the parapet height be less than that required by:

Table 1504.8

1504.8

Anchors designed to resist wall out-of-plane forces with design strengths equal to or greater than the force determined in accordance with ASCE/SEI 7 Equation 12.11-1 or 12.14-10 shall be deemed to satisfy which section of ACI 318?

Section 17.10.5.3(d)

1905.7.1 Exception

If unidentified reinforcement is approved for use, not less than how many tension tests must be made on representative specimens from each shipment and grade of reinforcing steel proposed for use?

three

2103.4

For special purpose roofs, an underlayment of 5/8-inch Type X water-resistant gypsum backing board or gypsum sheathing shall be placed under minimum nominal 1/2-inch-thick wood structural panel solid sheathing or:

1-inch nominal spaced sheathing

1505.7

High-hazard Group H occupancy is required when the quantities of hazardous materials exceed those allowed in control areas complying with:

Section 414

307.1

In each story of a separated occupancy building, the building area shall be such that the sum of the ratios of the actual building area of each separated occupancy divided by the allowable building area of each separated occupancy shall not exceed:

1

508.4.2

The first coat of exterior cement plaster must be moist cured for a minimum period of how long?

48 hours

Table 2512.6

Broken glass retention screens must be installed within what maximum distance of the glass?

4 inches (102 mm).

2405.3

The response modification coefficient, R, designated for “Steel systems not specifically detailed for seismic resistance, excluding cantilever column systems” shall be permitted for cold-formed steel systems designed and detailed in accordance with AISI S100, and such systems need not be designed and detailed in accordance with which other standard?

AISI S400

2204.2.2

The aggregate area of penthouses and other enclosed rooftop structures shall not exceed what fraction of the area of the supporting roof deck?

one-third

1511.1.1

A building intended for unlimited area use (Section 507) has 90 percent of its perimeter fronting on an open space between 40 feet and less than 45 feet. What is the allowable Frontage Increase Factor?

1.13

Table 506.3.3.1

Where an airport traffic control tower is provided with only one exit stairway, interior wall and ceiling finishes shall be Class A or:

Class B

412.2.2.3.1

What is the minimum required fire-resistance rating in hours for exterior bearing walls in a Type IIIA building?

2

Table 601

Each light-transmitting plastic skylight must have a maximum area within the curb of:

100 square feet (9.3 m2)

2610.4

Seismic anchorage for masonry fireplaces is not required where the masonry fireplace is constructed completely within the:

exterior walls

2111.5 Exception

Where a standpipe is required in accordance with Section 3311, what is the maximum distance allowed between the fire hydrant used for the water supply and the fire department connection supplying the standpipe?

100 feet (30 480 mm)

3313.4

For individual dwelling units in Groups R-2, R-3, and R-4, fully tempered glass used as single or multiple glazing does not require screening if each pane is 16 square feet (1.5 m2) or less, and the glass thickness is what maximum thickness?

3/16 inch (4.8 mm) or less.

2405.3.3

Which criterion must be met for an existing structure to continue its legal occupancy after the adoption date of this code?

As otherwise specifically provided in the code, the International Existing Building Code, the International Fire Code, or the International Property Maintenance Code

202 [A] Approved

Flammable Vapors or Fumes are defined by a concentration of flammable constituents in air that exceeds what percentage of their lower flammable limit (LFL)?

25 percent

202 [F] Flammable Vapors or Fumes

If a mass timber building element requires a 2-hour fire-resistance rating, what is the minimum protection time required from the noncombustible protection in minutes?

80 minutes

Table 722.7.1(1)

Gypsum wallboard, gypsum lath, or gypsum plaster shall not be installed until what condition is met?

Weather protection for the installation is provided.

2508.2.1

Special inspections and qualification of welding special inspectors for cold-formed steel floor and roof deck must be in accordance with the quality assurance inspection requirements of:

SDI QA/QC.

1705.2.3

The thickness of SFRM applied to floor, roof and wall assemblies must be determined in accordance with ASTM E605, making not less than four measurements for each what size area?

1,000 square feet (93 m2) of the sprayed area.

1705.15.4.2

To qualify for an area factor increase based on frontage, the public way or open space must have a minimum distance of 20 feet (6096 mm) measured at right angles from the building face to which of the following?

The closest interior lot line

506.3.2

Garage doors and rolling doors shall be labeled with a permanent label identifying the door manufacturer, the door model/series number, the positive and negative design wind pressure rating, the applicable test standard, and the:

installation instruction drawing reference number.

1709.5.2.1

Where plumbing fixtures are required, separate facilities must be provided for each sex, unless what maximum total occupant load exists in the structures or tenant spaces (including both employees and customers)?

15 or fewer

2902.2 Exception

Edge protection barriers on ramps shall be constructed so that the barrier prevents the passage of a sphere with a diameter of 4 inches (102 mm) where any portion of the sphere is within what distance of the floor or ground surface?

4 inches (102 mm)

1012.10.1

For Residential occupancies classified as “Apartment house,” what is the required minimum number of automatic clothes washer connections?

1 per 20 dwelling units

Table 2902.1

Flashing and weep holes in anchored veneer must be located not more than what maximum distance above finished ground level above the foundation wall or slab?

10 inches (245 mm)

1404.4.3

Supplemental information submitted for a relocatable building must include, at a minimum, what information regarding site-built attachments?

Site-built structure or appurtenance attached to the relocatable building.

3113.2

What is the maximum permitted thickness for a surfacing material that has a flame spread index not greater than 50 (when tested to ASTM E84 or UL 723) to be considered noncombustible when applied over a structural noncombustible base?

0.125 inch (3.18 mm)

703.3.1 Exception

What is the minimum required fire-resistance rating for an exterior wall of a nonsprinklered Group F-1, M, or S-1 occupancy where the fire separation distance is 10 feet or greater and less than 30 feet, and the construction type is IIB or VB?

Not regulated

Table 705.5

Special inspections and tests for glass unit masonry or masonry veneer in a structure classified as Risk Category IV shall be performed in accordance with:

TMS 602 Level 2.

1705.4.1

If the 60-foot (18 288 mm) public ways or yards are reduced to 40 feet (12 192 mm), what is the minimum required fire protection rating for the opening protectives in the exterior walls facing the reduced width?

3 hours

507.2.1

Where two or more flues are located in the same chimney, masonry wythes shall be built between adjacent flue linings with a minimum thickness of:

4 inches (102 mm)

2113.14

Required design wind pressures determined from ASCE 7 for exterior windows and doors shall be permitted to be converted to allowable stress design by multiplying by which factor?

0.6.

1709.5

What is required documentation for the site safety director and fire watch personnel?

Documentation of their training

3302.1.1

What means must be provided to automatically disconnect the main line power supply to an affected elevator prior to the application of water from automatic sprinklers?

A means installed in accordance with Section 21.4 of NFPA 72

3005.5

Group A-1 and A-2 occupancies located in mixed occupancy buildings of unlimited area (Section 507.4) shall have their exit doors discharge to where?

Directly to the exterior of the building

507.4.1

Plastic signs shall be located not less than what distance from adjacent tenants?

18 inches (457 mm)

402.6.4.3

Where a platform (wheelchair) lift is used as part of a required accessible route to jury boxes and witness stands, the lift must be installed in accordance with:

ASME A18.1

1110.11

Greenhouses that are occupied for growing or maintaining plants, without public access, are exempt from the area limitations of Table 2609.4 provided they have a minimum fire separation distance of:

4 feet (1220 mm)

2609.4 Exception

Modified bitumen roofing shall have a design slope of not less than what minimum units vertical in 12 units horizontal for drainage?

1/4 unit

1507.11.1

Where an HVAC system is fully ducted in Group I-2, a lay-in ceiling system is considered capable of limiting the transfer of smoke if the ceiling tiles weigh not less than:

1 pound per square foot (4.882 kg/m2)

710.4 Exception

Wall sheathing is prohibited from being attached to framing members by which method in conventional light-frame construction?

Adhesives

2308.10.9

The allowable compressive stress based on the gross cross-sectional area of adobe shall not exceed:

30 psi (207 kPa)

2109.2.3

Two-way communication systems at elevator landings shall provide communication between each required location and the fire command center or a central control point location approved by the fire department. If the central control point is not a constantly attended location, the system must have timed, automatic telephone dial-out capability to an approved supervising station or:

emergency services

1009.8.1

Fire protection of structural members in roof construction shall NOT be required (even if Table 601 specifies a rating) where every part of the roof construction is 20 feet or more above any floor or mezzanine immediately below, EXCEPT in which occupancy groups?

F-1, H, M, and S-1

Table 601, Footnote c

Walls required to be waterproofed shall be of concrete or masonry and waterproofing shall be applied from the bottom of the wall to not less than what minimum distance above the maximum elevation of the ground-water table?

12 inches (305 mm)

1805.3.2

Footings for masonry chimneys must extend not less than what minimum distance beyond the face of the foundation or support wall on all sides?

6 inches (152 mm)

2113.2

For Business occupancies, what is the required ratio for lavatories for the first 80 occupants?

1 per 40

Table 2902.1

What must be discontinued and capped in accordance with the approved rules and requirements of the applicable governing authority during demolition?

Service utility connections

3303.6

Where installed on buildings of Types I, II, III and IV construction, metal composite material (MCM) must have a flame spread index of not more than:

25

1406.10.1

For smoke-protected assembly seating with a total number of seats of 10,000, what is the required capacity in inches per seat served for level aisles?

0.1

Table 1030.6.2

What action must an elevator emergency two-way communication system enable authorized personnel to verify?

The presence of someone in the car and that the person(s) is trapped

3001.2

For cold-formed steel light-frame construction, the design and installation of nonstructural members and connections must be in accordance with which standard?

AISI S220

2206.2

Standby power is required for common exhaust systems for domestic kitchens located in multistory structures as required in which section of the International Mechanical Code?

Section 505.5

2702.2.5

For Higher education laboratories, what is the required fire-resistance rating for fire barriers separating a laboratory suite located on the third floor above grade plane from other portions of the building?

1 hour

Table 428.3

Where must the manufacturer’s data plate be permanently attached on or adjacent to each relocatable module?

On or adjacent to the electrical panel.

3113.3

In a safe dispersal area, the area shall be located on the same lot not less than what minimum distance away from the building requiring egress?

50 feet (15 240 mm)

1028.5 Exception 2

In under-floor spaces with uncovered earth floors, the net area of ventilation openings shall be not less than 1 square foot for each how many square feet of crawl space area?

150 square feet

1202.4.1.1

Inverters used in photovoltaic solar energy systems connected to the utility grid must be listed and labeled in accordance with which UL standard?

UL 1741.

3111.3.1

A correctional center or jail inhabited by more than five persons who are under restraint or security is classified as which Institutional Group?

Group I-3

308.4

In Type IV-B construction, unprotected portions of mass timber walls are limited to an area less than or equal to what percentage of the floor area in any dwelling unit or fire area within a story?

40 percent

602.4.2.2.2 Exception 1.2

According to Table 1507.8.7, what is the maximum weather exposure (in inches) permitted for 24-inch, Grade No. 3 wood shingles of naturally durable wood installed on a 3:12 pitch to less than 4:12 pitch?

5

1507.8.7

In Group E occupancies, enhanced classroom acoustics shall be provided in all classrooms with a volume of what maximum size?

20,000 cubic feet (566 m3)

1207.2

BIPV roof panels shall be used only on roof slopes of what minimum units vertical in 12 units horizontal or greater?

2 units

1507.17.2

Unit masonry walls must be parged on the exterior surface below ground level with not less than what minimum thickness of Portland cement mortar prior to dampproofing material application?

3/8 inch (9.5 mm)

1805.2.2.1

According to Table 2113.16(1), what is the cross-sectional area (square inches) of a round flue with an inside diameter of 10 inches?

78

2113.16.2

For wood shear walls and diaphragms designed to resist lateral loads of permanent load duration only, the allowable stress design unit shear capacities must be taken as the AWC SDPWS nominal unit shear capacities multiplied by what factor?

0.2

2305.1.2

Vertical reinforcement in masonry chimneys must be enclosed within 1/4-inch (6.4 mm) ties or equivalent reinforcing spaced not to exceed what maximum distance on center in concrete?

18 inches (457 mm)

2113.3.2

What is the minimum nominal thickness in the least dimension required for wood supports, wood stripping, or furring for lath or gypsum panel products?

2 inches (51 mm)

2504.1.1

For unvented attic assemblies, Section 1202.3 does not apply to enclosures in Climate Zones 5 through 8 that are humidified beyond what maximum percentage during the three coldest months?

35 percent

1202.3 Exceptions

Fasteners for horizontal gypsum panel product diaphragm ceilings must be spaced not more than what maximum distance on center at all supports, including perimeter blocking?

7 inches (178 mm)

2508.6.4

The design, testing, and utilization of steel storage racks made of cold-formed or hot-rolled steel structural members must be in accordance with which standard?

ANSI MH16.1

2209.1

For a smaller tenant space to pass through a larger adjoining tenant space, the rooms or spaces of the smaller tenant must occupy less than what maximum percentage of the area of the larger tenant space?

10 percent

1016.2.1 Exception

The design and construction of cold-formed steel floor and roof decks and composite slabs of concrete and steel deck must be in accordance with which standard?

SDI SD

2208.1

Each private garage shall be classified as a Group U occupancy and shall be not greater than what area?

1,000 square feet (93 m2)

406.3.1

Doors in smoke partitions that are required to meet the requirements for a smoke and draft control door assembly must have an air leakage rate not exceeding what value at 0.10 inch of water (25 Pa) for both the ambient and elevated temperature tests?

3.0 cubic feet per minute per square foot

710.5.2.2

Light-transmitting plastic wall panels are prohibited from being used in exterior walls in which occupancy groups?

Groups A-l, A-2, H, I-2 and I-3

2607.1

Directional signage indicating the route to the nearest like accessible element shall be provided at which of the following locations?

Inaccessible building entrances

1112.3

Interior walls and partitions that exceed 6 feet in height shall resist a horizontal load of not less than:

5 psf (0.240 kN/m2)

1607.16

Design strengths and permissible stresses of structural material must conform to the specifications and methods of design of accepted engineering practice or the approved rules in the absence of:

applicable standards.

1706.1

What is the required interior wall and ceiling finish classification for corridors in a nonsprinklered Group B occupancy?

Class B

Table 803.13

What is the maximum permitted area in square feet for each opening through a fire wall?

156 square feet (15 m2)

706.8

According to Table 1404.3(3), in Climate Zone 7, what is the minimum R-value of continuous insulation required over a 2×6 wall to permit the use of a Class III vapor retarder?

R-15

1404.3

Required public toilet facilities shall be provided with signs that indicate whether the facility is to be used by males, by females, or by whom else?

All persons regardless of sex

2902.4

Where parking is provided beneath a building, accessible parking spaces shall be provided:

beneath the building

1106.7.1

For insulated metal panel (IMP) systems with a combustible core insulation of 4 inches or less in thickness, the core must have a flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in accordance with:

ASTM E84 or UL 723

1409.7.1

In Type IV construction, the maximum building height permitted for grain elevators and similar structures is:

65 feet (19 812 mm)

426.1.1

The scope of the geotechnical investigation, including the number and types of borings, must be determined by a:

registered design professional

1803.3.1

In Seismic Design Categories B, C, D and E, where the bottom of the footing is stepped and the required braced wall panel height varies more than 4 feet, metal ties used to splice the cripple stud wall plate to the sill plate must be what minimum galvanized gage?

16 galvanized gage

2308.10.8.3

Where changes in elevation of less than 12 inches (305 mm) exist in the means of egress, sloped surfaces must be used, and ramps complying with Section 1012 must be used where the slope is greater than:

One unit vertical in 20 units horizontal (5-percent slope)

1003.5

The building official is authorized to disconnect utility service in case of emergency where necessary to eliminate an immediate hazard to life or property, or when the utility connection:

Has been made without the required approval

112.3

Glass in elevator car enclosures, glass elevator car doors, and glass used for lining walls and ceilings of elevator cars must be laminated glass conforming to Class A of ANSI Z97.1 or which Category of CPSC 16 CFR Part 1201?

Category II.

2409.4.1

When plastering with cement plaster over metal lath, wire fabric lath, or gypsum board backing for exterior application, how many coats minimum must be applied?

not less than three coats

2512.1

Walls and partitions constructed of adobe units must be supported by foundations or footings that extend not less than what minimum distance above adjacent ground surfaces?

6 inches (152 mm)

2109.2.4.5.1

A polyethylene vapor retarder placed between the base course or subgrade and the concrete floor slab must be 6-mil minimum thickness with joints lapped not less than:

6 inches (152 mm)

1907.4

Wood veneers on exterior walls of Types I, II, III and IV construction shall not exceed 40 feet in height above grade, unless fire-retardant-treated wood is used, in which case the height shall not exceed:

60 feet (18 290 mm)

1404.6

What must the strength of new welds and connections for intermodal shipping containers be relative to the original connections?

Not less than the strength provided by the original connections.

3114.8.2

An engineering analysis and load test of construction, when required by the building official, shall be conducted in accordance with which section?

Section 1708

1604.6

For clay, sandy clay, silty clay, clayey silt, silt and sandy silt, the lateral sliding resistance shall not exceed what maximum fraction of the dead load?

one-half

1806.3.2

According to Table 716.1(1), the marking “OH” on fire-rated glazing indicates that the assembly meets which criteria?

Meets fire window assembly criteria including the hose stream test

Table 716.1(1)

The top of a foundation drain must be covered with an:

approved filter membrane material.

1805.4.2

To determine the occupant load of each sex, the total occupant load shall be divided in half, but an exception applies where approved statistical data indicates a distribution of the sexes of other than what specific percentage of each sex?

50 percent

2902.1.1 Exception

For roof structures that support photovoltaic panel systems, roof live loads need not be applied to the area covered by the panels where the clear space between the panels and the roof surface is:

24 inches (610 mm) or less

1607.22.1

Unbalanced backfill height is the difference in height between the exterior finish ground level and the lower of the interior finish ground level or the:

top of the concrete footing that supports the foundation wall

1807.1.2

For buildings of Type IIIA construction in Groups R-1 and R-2, the maximum allowable height in Table 504.3 shall be increased by 10 feet (3048 mm) and the maximum allowable number of stories in Table 504.4 shall be increased by one, provided the first-floor assembly above the basement has a fire-resistance rating of not less than:

3 hours

510.5

Clay flue liners must be laid in medium-duty nonwater-soluble refractory mortar conforming to ASTM C199 with tight mortar joints left smooth on the inside and installed to maintain an airspace or insulation not to exceed the thickness of the flue liner separating the flue liners from the interior face of the:

chimney masonry walls

2113.12

Air-Impermeable Insulation must have an air permeance equal to or less than what value at 75 pa pressure differential?

0.02 l/s × m2

202 [BF] Air-Impermeable Insulation

Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with Section 1112.5 and:

ICC A117.1

1112.5.1

In structures without elevator service, where stories have entrances proximate to arrival points, and the slope of the undisturbed site measured between the entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) is what maximum percentage, all units on that story shall be Type B units?

10 percent

1108.7.1.2 Item 1

Two or more buildings on the same lot shall be regulated as separate buildings unless which condition is met?

Their height, number of stories, and aggregate area are within the limits of Sections 504 and 506

503.1.2

What is the minimum height required for the fire service access elevator symbol?

3 inches (76 mm)

3007.6.5

In conventional light-frame construction, for Seismic Design Categories D and E, what is the maximum spacing permitted for braced wall lines?

25 feet (7620 mm)

2308.10.1

Exterior adhered porcelain tile units weighing more than 3.5 pounds per square foot shall not exceed 48 inches in any face dimension nor more than what maximum area in total face area?

9 square feet (0.8 m2)

1404.11.2

The finished ground level of an under-floor space such as a crawl space shall not be located below the:

bottom of the footings

1805.1.2

Gutters and leaders placed on the outside of buildings, other than Group R-3, private garages and buildings of Type V construction, shall be constructed of noncombustible material or:

not less than Schedule 40 plastic pipe

1502.3

According to Table 1705.5.3, inspecting the erection of mass timber construction requires which type of inspection?

Periodic special inspection.

Table 1705.5.3 Item 2

If an entrapment is verified, what must the elevator emergency two-way communication system enable authorized personnel to communicate?

When help is on the way and when help arrives on site

3001.2

A single fixture is the minimum required for the number of persons indicated or what maximum fraction of the number of persons indicated in Table 2902.1?

Any fraction

2902.1 Note

Adobe construction is limited to buildings not exceeding one story, except that two-story construction is allowed where designed by a:

registered design professional

2109.2.4.1

The lift coefficient for concrete and clay tile shall be 0.2 or shall be determined in accordance with SBCCI SSTD 11 or which ASTM standard?

ASTM C1570

1504.3.1.3

Institutional Group I-2 occupancy is characterized by providing medical care on a 24-hour basis for more than how many persons who are incapable of self-preservation?

More than five

308.3

Where a building is equipped throughout with an automatic sprinkler system, the required separation distance between exits shall be not less than what fraction of the length of the maximum overall diagonal dimension of the area served?

One-third

1007.1.1 Exception 2

Not less than what percentage of vehicle spaces on the site served by electrical vehicle charging systems shall be accessible, but not fewer than one for each type of charging system?

5 percent

1107.2.1

In Group I-3 occupancies, door openings to resident sleeping units that are not required to be an Accessible unit shall have a minimum clear opening width of what distance?

28 inches (711 mm)

1010.1.1 Exception 2

Where the design wind pressure for aluminum fascia is 30 pounds per square foot or less, the fascia must be attached with one finish nail in the return leg spaced not greater than:

24 inches (610 mm) on center

1412.7.1

What type of plaster is permitted to be applied to interior cement plaster base coats after a 48-hour period?

Finish coat plaster

Table 2512.6 Note c

A live/work unit is permitted to be not greater than what maximum area?

3,000 square feet (279 m2)

508.5.1

According to Table 2109.2.3.1, what is the minimum embedment (inches) required for a 7/8-inch-diameter bolt in adobe masonry?

18

2109.2.3.1

Wood poles embedded in earth shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B) for sawn timber posts and (Commodity Specification B, Use Category 4B) for:

round timber posts

1807.3.1

Rooftop-mounted PV panel systems shall be assigned to the same risk category as:

the risk category of the building on which they are mounted

1604.5.2

According to Table 722.2.3(2), what is the minimum concrete cover thickness (in inches) for prestressed carbonate aggregate slabs in unrestrained assemblies requiring a 4-hour fire-resistance rating?

2 1/4

Table 722.2.3(2)

To qualify for unlimited area in a one-story Group E building of Type II, IIIA or IV construction, each classroom must have not less than two means of egress, with one being a direct exit to the outside complying with which section?

Section 1022

507.11

Chimneys located entirely outside the exterior walls of the building, including chimneys that pass through the soffit or cornice, shall have a minimum airspace clearance of:

1 inch (25 mm)

2113.19

The maximum allowable diaphragm proportions for horizontal gypsum panel product diaphragm ceilings shall be what ratio between shear resisting elements?

1 1/2:1

2508.6.1

Foam plastic used as interior trim must comply with Sections 2604.2.1 through 2604.2.4. What is the minimum density required for the interior trim?

20 pcf (320 kg/m3)

2604.2.1

Whenever there is reasonable doubt as to the stability or load-bearing capacity of a completed structure, an engineering assessment shall be required, involving either a structural analysis or an:

in-situ load test, or both.

1708.1

Covered or open mall buildings shall not exceed three floor levels at any point nor more than how many stories above grade plane?

Three

402.1

According to Table 1808.8.1, what is the minimum specified compressive strength (*f’*c) required for foundations for structures assigned to Seismic Design Category D, E or F, other than Group R or U of light-frame construction two stories or less?

3,000 psi

1808.8.1

In single-ply application, edges and ends of gypsum panel products shall be in moderate contact except in concealed spaces where which of the following is not required?

Fire-resistance-rated construction, shear resistance, or diaphragm action

2508.3

Refrigeration machinery rooms larger than 1,000 square feet (93 m2) require not less than two exits or exit access doorways. Where two are required, one is permitted to be served by a fixed ladder or an:

Alternating tread device

1006.2.2.2

Skylights set at an angle of less than 45 degrees (0.79 rad) from the horizontal plane shall be mounted not less than 4 inches (102 mm) above the plane of the roof on a:

curb constructed as required for the frame.

2405.4

Louvers protecting intake and exhaust ventilation ducts located within 30 feet of grade must meet the requirements of which standard?

AMCA 540

1609.2.1

The provisions governing the design and construction of buildings for energy efficiency are found in the:

International Energy Conservation Code

101.4.6

The construction documents for structural concrete must include the specified compressive strength of concrete at the stated ages or stages of construction for which each concrete element is designed, and the specified strength or grade of:

reinforcement

1901.5

Where required, the automatic secondary on-site water supply for high-rise buildings shall have a duration of not less than:

30 minutes

403.3.3

Fall arrest, lifeline, and rope descent system anchorages shall be designed for a live load of not less than what minimum force for each attached line, in any direction the load can be applied?

3,100 pounds (13.8 kN)

1607.12.4

Occupiable spaces, habitable spaces and corridors shall have a minimum ceiling height of:

7 feet 6 inches (2286 mm)

1208.2

In Type IV-HT construction, fire-retardant-treated wood framing and sheathing are permitted within exterior wall assemblies with a maximum rating of:

2 hours or less

602.4.4.1

For a Group R occupancy, where the corridor serves an occupant load greater than 10, what is the required fire-resistance rating for the corridor walls in a sprinklered building?

0.5 hour

Table 1020.2

Where a standpipe is required in accordance with Section 3311, what is the required minimum flow of the water supply?

500 gallons per minute (1893 L/m)

3313.4

For alternating tread devices, the minimum tread depth shall be 5 inches (127 mm), and the maximum riser height shall be:

9 1/2 inches (241 mm)

1011.14.2

For anchor bolts attaching a wood sill plate to concrete, anchor bolts must be located not less than what minimum distance from the edge of the concrete parallel to the length of the wood sill plate?

1 3/4inches (45 mm)

1905.7.2 Exception 1.4

In Type IV-C construction, the exterior side of walls of combustible construction must be protected with noncombustible protection having a minimum assigned time of:

40 minutes

602.4.3.1

The minimum ambient and substrate temperature to be maintained during and for not fewer than 24 hours after the application of SFRM is:

40°F (4.44°C)

704.12.4

What are the minimum nominal dimensions required for wood members used for perimeter blocking for horizontal gypsum panel product diaphragm ceilings?

2-inch by 6-inch (51 mm by 152 mm)

2508.6.3

Clearance between wood siding and earth on the exterior of a building shall be not less than:

6 inches (152 mm)

2304.12.1.5

Where Table 509.1 permits an automatic sprinkler system without a fire barrier, the walls separating the incidental use must be constructed to resist the passage of:

Smoke

509.4.2

The thermal barrier is required on the underside of a structural floor system containing foam plastic insulation if the underside of the structural floor system is exposed to:

the interior of the building.

2603.4.1.14

According to Table 415.6.5, for Class 2 Oxidizer, liquids and solids, a detached building is required where the quantity of material exceeds:

2,000 tons

Table 415.6.5

For unvented attics in Climate Zone 7, what is the minimum R-value of air-impermeable insulation required, expressed as a percentage of the total R-value, for condensation control?

60%

Table 1202.3

When a Group S-2 enclosed parking garage (maximum one story above grade plane) is located below a Group S-2 open parking garage, the height and number of tiers of the open parking garage shall be limited as specified in which table?

Table 406.5.4

510.3

Bulkheads used for the shelter of mechanical or electrical equipment or vertical shaft openings in the roof assembly shall comply with Section 1511.2 as:

penthouses

1511.7.2

For moist (A) or marine (C) climate zones, drainage on the exterior side of the water-resistive barrier must have a minimum drainage efficiency of what maximum percentage as measured in accordance with ASTM E2273 or Annex A2 of ASTM E2925?

90 percent

2510.6.2

Doors to resident sleeping units in Group I-3 occupancies shall have a clear width of not less than:

28 inches (711 mm)

408.3.1

The weep screed shall be placed not less than 4 inches (102 mm) above earth or what minimum distance above paved areas?

2 inches (51 mm)

2512.1.2

Type A units and Type B units shall not be required for buildings without elevator service in flood hazard areas where the minimum required floor elevation results in both a difference in elevation and a slope exceeding 10 percent between the minimum required floor elevation and vehicular/pedestrian arrival points within 50 feet (15 240 mm), with the elevation difference exceeding:

30 inches (762 mm)

1108.7.5 Item 1

What is the maximum number of tiers allowed for a Type IB mechanical-access open parking garage that is NOT equipped with an automatic sprinkler system?

12 tiers

Table 406.5.4

In auditoriums in Group A occupancies that are equipped throughout with an approved automatic sprinkler system, the permissible amount of combustible decorative materials suspended from walls shall not exceed what percentage of the aggregate wall area?

75 percent

806.2 Exception 1

According to Table 1507.10.2, which ASTM standard applies to Coal-tar pitch used in roofing?

ASTM D450; Type I or II

1507.10.2

In multilevel assembly seating areas utilized for worship services, if the second floor or mezzanine level contains 25 percent or less of the total seating capacity, wheelchair spaces are permitted to all be located where?

on the main floor level

1109.2.4 Exception 1

When a geotechnical report is required, it must be submitted to the building official by the permit applicant at the time of:

permit application

1803.6

What information must be continuously displayed at the fire command center (or approved alternate location) for occupant evacuation elevators?

Floor location, direction of travel, occupancy status, and power status, among other information

3008.7

Chimneys for medium-heat appliances must be constructed of solid masonry units or concrete with walls not less than 8 inches (203 mm) thick, or with stone masonry not less than how thick?

12 inches (305 mm)

2113.11.2.1

In Group I-1, Condition 2 occupancies, at least what percentage, but not less than one, of the dwelling units and sleeping units shall be Accessible units?

10 percent

1108.5.1.2

For a constructed covered walkway (Exception to 3306.7), what are the minimum dimensions required for members used to knee brace the posts to joists and stringers?

Not less than 2 inches by 4 inches (51 mm by 102 mm); 4 feet (1219 mm) in length

3306.7 Exception

Fire testing of a raised-deck system is not required where the decking or pavers of the system consists of brick, masonry, concrete or other:

noncombustible materials

1511.9.2.1 Exception

Where a building is equipped throughout with an automatic sprinkler system, the maximum percentage area of exterior wall in light-transmitting plastic wall panels given in Table 2607.4 can be increased by what percentage?

100 percent

2607.5

The fire-resistance rating of penetrations and fire-resistant joint systems shall be determined in accordance with which sections, respectively?

714 and 715

703.2.1

Standard calculations contained in ASTM D7158 assume Exposure Category B or C and a building height of what maximum distance or less?

60 feet

1504.2

What is the exception to the rule prohibiting elevators in a common shaft enclosure with a stairway?

Elevators within open parking garages

3002.7 Exception

The roof structure supporting a raised-deck system must be designed to support any standing water resulting from the installation of the raised-deck system, as required by Section 1502 and the:

International Plumbing Code

1511.9.5

Where exterior wall openings are required to be protected by Section 705.9, a light-transmitting plastic roof panel shall not be installed within what maximum distance of such exterior wall?

6 feet (1829 mm)

2609.3

Where required, fire-resistant joint systems must be tested in accordance with ASTM E1966 or UL 2079. For nonsymmetrical wall joint systems, which side(s) must be exposed to the furnace during testing?

Both faces

715.3.1

Vehicular gates intended for automation must be designed, constructed, and installed to comply with which standard?

ASTM F2200.

3110.2

To be excepted from NFPA 285 testing, a combustible water-resistive barrier (WRB) that is the only combustible component must have a flame spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84 or UL 723, with test specimen preparation and mounting in accordance with:

ASTM E2404

1402.6 Exception 2.2

For designs outside the scope of Section 2404, who must prepare an analysis or test data for the specific installation?

A registered design professional.

2404.4

For anchor bolts attaching a wood sill plate to concrete, the allowable in-plane shear strength is determined in accordance with ANSI/AWC NDS Table 12E for what type of lateral design value?

Parallel to grain

1905.7.2 Exception 1.1

When designing wood elements using allowable stress design, the allowable unit stresses for preservative-treated wood are not required to be adjusted for treatment, but load duration factors greater than what maximum value shall not be used in the structural design?

1.6

2306.1.3

What is the maximum allowable building height in feet for a Type IIA construction building classified as Group I-2 that is equipped throughout with an automatic sprinkler system (S)?

85

Table 504.3

Where interior glazing is installed adjacent to a walking surface, the differential deflection of two adjacent unsupported edges shall be not greater than the thickness of the panels when a force of 50 plf (730 N/m) is applied horizontally at any point up to:

42 inches (1067 mm) above the walking surface.

2403.4

The formula for determining the depth of embedment required to resist lateral loads for nonconstrained embedded posts is subject to a maximum embedment depth for the purpose of computing lateral pressure of:

12 feet (3658 mm)

1807.3.2.1

Regarding the building official’s interpretations, policies, and procedures to clarify application, they shall not have the effect of:

Waiving requirements specifically provided for in this code

104.2

The face of an exit sign illuminated from an external source shall have an intensity of not less than:

5 footcandles (54 lux)

1013.6.2

For high-pressure decorative exterior-grade compact laminates (HPL) installed on buildings of Types I, II, III and IV construction, the HPL must have a flame spread index of not more than:

25

1408.10.1

In under-floor spaces with the ground surface covered with a Class I vapor retarder, the net area of ventilation openings shall be not less than 1 square foot for each how many square feet of crawl space area?

1,500 square feet

1202.4.1.2

Special inspections for seismic resistance are not required for light-frame construction structures where the design spectral response acceleration at short periods, does not exceed 0.5 and the building height does not exceed:

35 feet (10 668 mm).

1705.13 Exception 1

Unless otherwise specified, high-pressure decorative exterior-grade compact laminates (HPL) shall have a flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in accordance with:

ASTM E84 or UL 723

1408.9

The net free area of a spark arrestor installed on a masonry chimney shall be not less than what minimum multiple of the net free area of the chimney flue outlet it serves?

four times

2113.9.2 Item 1

Openings providing access to attic or concealed spaces used for storage of combustible materials shall be protected by assemblies that are self-closing and of solid wood core not less than:

1 3/4 inches (45 mm) in thickness

413.2

According to Table 1705.2.4, is continuous or periodic special inspection required for the installation of end connections (welding or bolted) of open-web steel joists?

Periodic special inspection.

Table 1705.2.4 Item 1.a

In a courtroom, the judge’s bench, clerk’s station, bailiff’s station, deputy clerk’s station and court reporter’s station shall be located on an accessible route, and vertical access to elevated work stations is not required at initial construction provided a ramp, lift or elevator can be installed without requiring reconfiguration or extension of the courtroom or:

installation of an assistive listening system

1109.4.1.4

The projection of a single corbeled course in a masonry chimney shall not exceed one-half the unit height or what maximum fraction of the unit bed depth, whichever is less?

one-third

2113.5

If an occupiable roof is provided, how shall it be classified?

In the group that the occupancy most nearly resembles

302.1

Walls separating dwelling units in the same building in Group R occupancies shall be constructed as:

Fire partitions in accordance with Section 708

420.2

What must the label contain, in addition to the manufacturer’s identification and definitive performance characteristics?

The approved agency's identification.

1703.5.3

To allow an occupancy on an occupiable roof that is different from the story immediately below it, the building must be equipped throughout with an automatic sprinkler system and what notification system?

Occupant notification in accordance with Sections 907.5.2.1 and 907.5.2.3 (and 907.5.2.2 if required)

503.1.4 Exception

Test samples for determining SFRM density must be selected from each floor, roof and wall assembly at a rate of not less than one sample for every what minimum area?

2,500 square feet (232 m2) or portion thereof.

1705.15.5 Item 1

For basic uniform live load reduction, the reduced design live load shall be not less than 0.40 L for members supporting how many floors?

two or more

1607.13.1

The minimum slope for standing-seam metal roof panel systems shall be:

one-quarter unit vertical in 12 units horizontal (2-percent slope)

1507.4.2

According to Table 414.2.2, what is the required fire-resistance rating for fire barriers separating control areas on the sixth story above grade plane?

2 hours

Table 414.2.2

Where reinstallation of materials is permitted, which existing components shall NOT be reinstalled where rusted, damaged or deteriorated?

Existing vent flashing, metal edgings, drain outlets, collars and metal counterflashings

1512.4

What is the maximum allowable building height in feet for a nonsprinklered (NS) building classified as Group F, M, S, or U of Type IVB construction?

65

Table 504.3

An automatic sprinkler system is required in Group E fire areas greater than 12,000 square feet (1115 m2) in area, or if the Group E fire area has an occupant load of:

300 or more

903.2.3

A structure wherein the shape is attained by air pressure and occupants are within the elevated pressure area is defined as an:

Air-supported structure

202 [BG] Air-Supported Structure

Emergency lighting shall be arranged to provide initial illumination that is not less than an average of 1 footcandle (11 lux) and a minimum at any point of:

0.1 footcandle (1 lux)

1008.3.2

In Group R-1 occupancies, where 350 total dwelling units or sleeping units are provided, what is the minimum required number of Accessible units with roll-in showers?

4

Table 1108.6.1.1

Slopes for permanent fill shall be not steeper than what ratio?

One unit vertical in two units horizontal (50-percent slope)

3304.1.1

Special inspections of the steel fabrication process are not required where the fabrication process for the entire building does not include any welding, thermal cutting or:

heating operation of any kind.

1705.2 Exception

For any approved product, material, or assembly, a record of approval, including the conditions and limitations, shall be kept on file in the building official’s office and must be available for:

public review at appropriate times.

1703.3

The shear values listed in Table 2508.6 shall be reduced by what percentage in Seismic Design Categories D, E, and F?

50 percent

Table 2508.6 Note b

Structures, sites, and equipment directly associated with the actual processes of construction are not required to comply with Chapter 11, including, but not limited to, scaffolding, bridging, and:

materials hoists

1103.2.5

In organic coatings manufacturing, storage areas for flammable and combustible liquid tanks inside structures shall be separated from the processing area by not less than:

2-hour fire barriers

418.4

According to Table 1806.2, what is the presumptive lateral bearing pressure (psf/ft below natural grade) for Sedimentary and foliated rock?

400

1806.2

A mezzanine is NOT required to be open to the room where the aggregate occupant load of the enclosed space is not greater than:

10

505.2.3 Exception 1

For Group R and U occupancies, the required 1-hour fire-resistance-rated exterior walls terminating at the underside of the roof must ensure that parallel roof/ceiling framing is not less than 1-hour rated for a width of:

4 feet (1220 mm)

705.12 Exception 4.1

In windborne debris regions, glazing located within 30 feet of grade shall meet the requirements of which test of ASTM E1996?

large missile test

1609.2

Where a shaft terminates below the roof assembly, the top enclosure must have the same fire-resistance rating as the topmost floor penetrated by the shaft, but not less than the rating required for the:

Shaft enclosure

713.12

Masonry chimneys and foundations must be anchored at each floor, ceiling, or roof line more than 6 feet (1829 mm) above grade with two 3/16-inch by 1-inch (4.8 mm by 25 mm) straps embedded not less than how deep into the chimney?

12 inches (305 mm)

2113.4

Where the steel grade is not readily identifiable from marking and test records, what action must be taken to verify conformity to such standards?

The steel shall be tested to verify conformity

2201.2

A drain placed around the perimeter of a foundation shall extend not less than what minimum distance beyond the outside edge of the footing?

12 inches (305 mm)

1805.4.2

At least what percentage, but not less than one, of care recipient and visitor parking spaces serving rehabilitation facilities specializing in treating conditions that affect mobility shall be accessible?

20 percent

1106.5

Where masonry chimneys are constructed as part of masonry or concrete walls, combustible materials shall not be in contact with the masonry or concrete wall less than what minimum distance from the inside surface of the nearest flue lining?

12 inches (305 mm)

2113.19 Exception 2

Periodic special inspection is required for nailing, bolting, anchoring and other fastening of elements of the seismic force-resisting system, including wood shear walls, wood diaphragms, drag struts, braces, shear panels and:

hold-downs.

1705.13.2 Item 2

Structural tolerances for cast-in-place concrete structural elements must be in accordance with ACI 117, with an exception for detached one- or two-family dwellings in which Group?

Group R-3

1901.7.1 Exception

According to Table 1807.1.6.3(4) for 12-inch nominal masonry walls (11.63 inches actual thickness), what is the minimum vertical reinforcement required for a 10-foot maximum wall height, 8-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft?

#7 at 56 inches

1807.1.6.3

Insulated metal panel (IMP) installations shall not exhibit sustained flaming where tested in accordance with NFPA 268, unless protected on the outside with concrete or masonry not less than:

1 inch (25 mm) in thickness

1409.7.3.4 Exception 2

Chimneys for high-heat appliances must be constructed with double walls of solid masonry units or concrete, each wall to be not less than 8 inches (203 mm) thick with a minimum airspace between the walls of:

2 inches (51 mm)

2113.11.3.1

Ballasted low-slope single-ply roof system coverings shall be designed in accordance with which standard?

ANSI/SPRI RP-4

1504.5

Basements not more than one story below grade plane are permitted in unlimited area buildings of the occupancies and configurations specified in which section?

Section 507.1

507.1

If a greenhouse is not classified as another occupancy (such as Group A-3 or Group M), how shall it be classified?

Group U

312.1.1

Ground-mounted photovoltaic (PV) panel systems are not required to accommodate which type of load?

Roof live load

1607.22.4

In ambulatory care facilities requiring smoke compartmentation, the area of any one smoke compartment shall be not greater than:

22,500 square feet (2092 m2)

422.3

Where gypsum sheathing is used as a backing for metal or wire fabric lath and cement plaster on walls, what must be provided in accordance with Section 2510.6?

A water-resistive barrier

2510.5.2.2

The uplift capacity of a single deep foundation element determined by an approved method of analysis must be based on a minimum factor of safety of:

3

1810.3.3.1.5

Mechanical equipment screens shall not exceed what maximum height above the roof deck, as measured to the highest point on the screen?

18 feet (5486 mm)

1511.6.1

What is the required fire-resistance rating for electrical circuit protective systems providing power and control signals to occupant evacuation elevators outside the machine room?

2 hours

3008.8.2

For preconstruction load tests, the test load shall be left in place for a period of:

24 hours.

1709.3.1

The design of cold-formed carbon and low-alloy steel structural members not covered in Sections 2206 through 2209 must be in accordance with which standard?

AISI S100

2204.1

The second coat of exterior cement plaster shall not have variations greater than 1/4 inch (6.4 mm) in any direction under what maximum length straight edge?

5-foot (1524 mm)

2512.5

All conveying systems and their components must comply with applicable design loading criteria in Chapter 16, including which types of loads?

Wind, flood, and seismic loads established in Sections 1609, 1612 and 1613

3001.6

What is the maximum height permitted for Type IIA construction for an airport traffic control tower?

100 feet

Table 412.2.1.1

If an occupant evacuation elevator lobby serves more than one elevator, what is the minimum number of elevators required to open into that lobby?

Not less than two

3008.1.1

In Group I-3 occupancies in buildings less than three stories above grade plane, which classification of interior finish is permitted in interior exit stairways for nonsprinklered buildings?

Class B

Table 803.13 Note b

Where adult changing stations are required in assembly and mercantile occupancies, it is based on the requirement of family or assisted-use toilet or bathing rooms, which is triggered when an aggregate of how many or more male and female water closets are required?

six

1110.4.1 Item 1, 1110.2.1

Pedestrian walkways connecting balconies in an open mall shall be located not less than what distance from any other pedestrian walkway?

20 feet (6096 mm)

402.4.3.1

The landing at an exterior door serving Groups F, H, R-2, and S and where such doors are not part of an accessible route, shall not be more than what distance below the landing on the egress side?

7 inches (178 mm)

1010.1.4 Exception 2

Foundation walls of not less than 8-inch nominal width are permitted to support brick-veneered frame walls and 10-inch-wide cavity walls, provided the requirements of Section 1807.1.6.2 or which other section are met?

Section 1807.1.6.3

1807.1.6.1

What is the minimum required fire-resistance rating for an exterior wall of a nonsprinklered Group H occupancy where the fire separation distance is greater than 5 feet and less 10 feet, and the construction type is Other than IA or IVA?

3 hours

Table 705.5

Interlayment for wood shakes shall comply with which ASTM standard?

ASTM D226, Type I

1507.9.5

When designing lap splices using Equation 21-1, the length of the lapped splice, shall be not less than:

40 bar diameters

2107.2.1

In occupancies other than covered and open mall buildings, the path of travel to required public and employee toilet facilities shall not exceed what maximum distance?

500 feet (152 m)

2902.3.3

What is the minimum required separation in hours between a nonsprinklered (NS) Group H-2 occupancy and a nonsprinklered (NS) Group H-3 or H-4 occupancy?

1

Table 508.4

The minimum required bearing length on each end of the fireplace opening for a lintel of noncombustible material shall be:

4 inches (102 mm)

2111.8

The test assembly for preconstruction load tests shall be subjected to an increasing superimposed load equal to not less than what factor multiplied by the superimposed design load?

two times.

1709.3.1

Polypropylene siding is limited to exterior walls located in areas where the basic wind speed does not exceed 100 miles per hour and the building height is less than or equal to 40 feet in which exposure classification?

Exposure C

1404.18

An accessible children’s water closet is permitted to be set not closer than what minimum distance from its center to the required partition or to the wall on one side?

12 inches (305 mm)

2903.1.1 Exception

For stepped aisles in assembly seating without smoke protection, where egress requires stepped aisle descent, not less than 0.075 inch (1.9 mm) of additional aisle capacity for each occupant shall be provided on those portions of aisle capacity that do not have a handrail within a horizontal distance of:

30 inches (762 mm)

1030.6.1

What is the required minimum width for public ways or yards surrounding a one-story aircraft hangar provided with an automatic fire-extinguishing system to qualify for unlimited building height?

Not less than one and one-half times the building height

504.1 Exception

According to Table 1507.8.7, what is the maximum weather exposure (in inches) permitted for 18-inch, Grade No. 1 wood shingles of naturally durable wood installed on a 4:12 pitch or steeper slope?

5.5

1507.8.7

Fuel lines supplying a generator set inside a high-rise building must be separated from other areas of the building by one of three approved methods, including a fire-resistant pipe-protection system tested in accordance with which UL standard?

UL 1489

2702.1.2

Accessible parking spaces shall be located on the shortest accessible route of travel from adjacent parking to an accessible building entrance, except in multilevel parking structures where van-accessible parking spaces are permitted on:

one level

1106.7 Exception 1

In cold-formed steel light-frame construction assigned to Seismic Design Category D, E or F, the seismic force-resisting system must be designed and detailed in accordance with which standard?

AISI S400

2206.1.1.2

According to Table 1809.7, what is the minimum width and thickness required for a prescriptive concrete footing supporting light-frame construction with three supported floors?

18 inches wide, 8 inches thick

1809.7

Exposed portions of building elements complying with the requirements for heavy timber construction are NOT subject to interior finish requirements, EXCEPT in:

Interior exit stairways, interior exit ramps, and exit passageways

803.3

Where hazardous materials having a hazard ranking of 3 or 4 are transported through corridors, a manual alarm station or initiating device must be installed at not more than what interval?

150-foot (45 720 mm)

415.5.2

Fasteners for wood shingles shall have a minimum penetration of 3/4 inch into the sheathing. For sheathing less than 1/2 inch in thickness, the fasteners shall:

extend through the sheathing

1507.8.6

Doors or horizontal sliding/vertical security grilles shall not be brought to the closed position when there are 50 or more persons occupying spaces served by:

More than one exit

402.8.8

A Basement is defined as a story that is not a:

Story above grade plane

202 [BG] Basement

The means of egress illumination level shall be not less than 1 footcandle (11 lux) at the walking surface. Along exit access stairways, exit stairways, and their required landings, the illumination level shall not be less than:

10 footcandles (108 lux)

1008.2.1

Glass sloped 15 degrees (0.26 rad) or less from vertical is considered vertical glass and must be designed to resist wind loads for components and cladding in accordance with which section?

Section 1609.

2404.1

Where High-Density Polyethylene (HDPE) or Polypropylene (PP) is used as an interior finish, it must comply with which specific section?

Section 803.1.1

803.9

The NS (nonsprinklered) value in Table 504.3 is provided solely for use in the evaluation of existing building height in accordance with the:

International Existing Building Code

Table 504.3 Footnotes

Where must the fire service access elevator be continuously monitored?

The fire command center

3007.7

Who must contract a registered design professional for the design of the temporary installation restraint/bracing and the PITMR and PITMDB for wood trusses spanning 60 feet or greater?

The owner or the owner's authorized agent

2303.4.1.3

Exit sign placement shall be such that any point in an exit access corridor or exit passageway is within what maximum distance or the listed viewing distance of the sign, whichever is less, from the nearest visible exit sign?

100 feet (30 480 mm)

1013.1

For vertical patterned glass (sloped 15 degrees or less from vertical), the design equation (Equation 24-9) requires the wind load (Fgw) to be less than what multiple of the nonfactored load (Fge)?

1.0 Fge

2404.3.3

Which of the following is defined as an extension or increase in floor area, number of stories or height of a building or structure?

Addition

202 [A] Addition

When testing the ignition characteristics of exterior walls in accordance with NFPA 268, assemblies protected on the outside with a minimum 7/8-inch (22.2 mm) thickness of stucco complying with Section 2510 are exempt from sustained flaming requirements, as are assemblies protected with minimum 1-inch thickness of concrete or:

masonry

2603.5.7 Exception

Cables listed in accordance with UL 2196 for survivability of required critical circuits serving fire service access elevators must have a minimum fire-resistance rating of how long?

2 hours

3007.8.1

According to Table 1404.3(1), vapor retarder paint applied to yield a perm rating greater than 1.0 and less than or equal to 10 is considered which class of vapor retarder?

Class III

1404.3

Fire-protection-rated glazing used as vision panels in self-closing swinging fire door assemblies serving as horizontal exits in fire walls shall be limited to what maximum area?

100 square inches (0.065 m2)

716.2.5.1.2.1

What are the construction classifications for noncombustible membrane structures and noncombustible frame or cable-supported structures covered by an approved membrane?

Type IIB construction.

3102.3

The ends of wood girders entering exterior masonry or concrete walls must be provided with a minimum airspace of:

1/2 inch (12.7 mm)

2304.12.2.1

Excluding noncombustible membrane structures serving as roofs only, what is the maximum height limitation for membrane structures?

Shall not exceed one story.

3102.5, 3102.5 Exception

Structural elements that support hoists for façade access and building maintenance equipment shall be designed for a live load of 2.5 times the rated load of the hoist or the:

stall load of the hoist, whichever is larger

1607.12.3

The separation distance to exit access stairways shall be measured to the closest:

riser

1007.1.1.1

One-story detached accessory structures used as tool and storage sheds are exempt from a building permit provided the floor area is not greater than:

120 square feet (11 m2)

105.2

Ground-mounted photovoltaic (PV) panel systems serving only Group R-3 buildings shall be assigned to which risk category?

Risk Category I

1604.5.2

Wires or cables providing power, control signals, communication, and fire-detecting systems to fire service access elevators must be protected by construction having a minimum fire-resistance rating of how long?

2 hours

3007.8.1

Where furring and furring attachments penetrate foam sheathing to connect to masonry or concrete construction, the fasteners used must be approved for application into masonry or concrete material and shall be installed in accordance with the:

fastener manufacturer's installation instructions

1404.5.1

Where stairways serve more than one story, or more than one story and an occupiable roof, which factor shall be used when calculating the required number of exits or access to exits serving that story?

Only the occupant load of each story or occupiable roof considered individually

1006.3.1

What must be provided for utility fixtures during the progress of the work?

Protection against damage

3308.2

Terra cotta and metal cornices must be provided with a structural frame of approved noncombustible material anchored in an:

approved manner

2104.1.2

Glass in elevator enclosures must comply with which section?

Section 2409.2

3002.8

Where mirrors or mazes disguise the path of egress travel in a special amusement area, low-level exit signs shall be located not more than what distance above the walking surface?

8 inches (203 mm)

411.4

Where a drain tile or perforated pipe is used for a foundation drain, the pipe or tile shall be placed on not less than what minimum thickness of gravel or crushed stone?

2 inches (51 mm)

1805.4.2

Modifications or changes in occupancy or use from that shown on the lease plan for a covered mall building shall not be made without prior approval of the:

Building Official

402.3

What type of barrier must separate the occupant evacuation elevator lobby from each floor?

A smoke barrier in accordance with Section 709

3008.6.2

What is the maximum number of seats permitted per row without backrests served by an aisle or doorway at one end only where the assembly seating contains 7,000 to 9,999 total seats?

11

Table 1030.13.2.1

If discrepancies noted during inspection are not corrected, they must be brought to the attention of the building official and the registered design professional in responsible charge prior to the completion of:

that phase of the work.

1704.2.4

According to Table 2109.2.3.1, what is the allowable shear load (pounds) for a 3/4-inch-diameter bolt embedded 15 inches in adobe masonry?

300 pounds

2109.2.3.1

The construction and utilization of vaults and other enclosed spaces below grade are subject to the terms and conditions of which entity?

The applicable governing authority.

3202.1.2

In Group I-2 occupancies, a laundry room over 100 square feet requires what separation and/or protection?

1 hour and provide automatic sprinkler system

Table 509.1

Which condition is listed as a required special inspection and test to demonstrate compliance with the listing and fire-resistance rating of SFRM?

Bond strength adhesion/cohesion.

1705.15.1 Item 4

Special inspections and tests are not required for Group U occupancies that are accessory to a residential occupancy, unless otherwise required by the:

building official.

1704.2 Exception 2

Exposed combustible trim or mantels can be placed directly on the masonry fireplace front surrounding the opening, provided such materials are not placed within what minimum distance of the fireplace opening?

6 inches (153 mm)

2111.12 Exception 4

What is the required construction type for pedestrian walkways?

Noncombustible construction.

3104.3

Anchored slab-type veneer units shall not exceed 2 inches in thickness, 48 inches in length or height, or what maximum area?

20 square feet (1.9 m2)

1404.9

Where the ratio of the depth of embedment of a deep foundation element to its least horizontal dimension is less than or equal to six, it shall be permitted to assume the element is:

rigid

1810.2.4

The height limitation for buildings of Type IIA construction in Groups R-1 and R-2 shall be increased to nine stories and 100 feet (30 480 mm) where the building is separated by not less than what minimum distance from any other building on the lot and from lot lines?

50 feet (15 240 mm)

510.6

When labeling a product, the approved agency must maintain a record of tests performed that provides sufficient detail to verify compliance with the:

test standard.

1703.5.1

According to Table 414.2.2, what is the maximum number of control areas permitted on the second story below grade plane?

2

Table 414.2.2

Whenever there is a reasonable doubt as to the structural integrity of a deep foundation element, an engineering assessment shall be required that includes tests for defects performed in accordance with ASTM D4945, ASTM D5882, ASTM D6760 or:

ASTM D7949.

1705.1

Corridors, toilet rooms, kitchenettes and break rooms are specifically excluded from the definition of an:

Employee Work Area

202 [BE] Employee Work Area

Where preservative-treated wood is used in enclosed locations where drying in service cannot readily occur, the wood must be at what maximum moisture content before being covered with insulation, interior finish, or other materials?

19 percent

2303.1.9.2

When are existing means of egress systems not required to be maintained during construction, demolition, remodeling, alterations, or additions?

Where approved temporary means of egress systems and facilities are provided

3310.2 Exception

When calculating the estimated value of work for a permit application, the valuation must include the total value of work, including materials and labor, and also include:

Permanent systems such as electrical, gas, mechanical, and plumbing

109.3

Masonry-unit footings must be laid in Type M or S mortar and the depth shall be not less than what factor multiplied by the projection beyond the wall, pier or column?

twice the projection

1809.9.1

An anchor building shall be separated from the covered or open mall building by:

Fire walls complying with Section 706

402.4.2.2

Unlimited area two-story buildings (Group B, F, M or S) must be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and surrounded by public ways or yards not less than:

60 feet (18 288 mm)

507.5

The exit access travel distance in temporary structures shall be what maximum distance?

100 feet (30 480 mm) or less.

3103.4

What is the maximum thickness of decorative materials (in inches) that, when applied directly to and adhering tightly to a substrate, are not considered decorative materials?

0.025 inch (0.64 mm)

202 [F] Decorative Materials

Where pictograms are provided as designations for toilet rooms and bathing rooms, the pictograms shall have visual characters, raised characters and braille complying with which standard?

ICC A117.1

1112.2

When using the Simplified Structural Design Procedure, the total linear length of all openings in any individual side wall or end wall designated as part of the lateral force-resisting system shall be limited to not more than what maximum percentage of the length of that side wall or end wall?

50 percent.

3114.8.5.3

Where water closet compartments and urinals provided in a toilet room or bathing room totals six or more, at least what percentage of the total number of compartments shall be ambulatory accessible?

5 percent

1110.2.4

As an exception to the hazardous location requirement for windows, a horizontal rail installed 34 to 38 inches (864 to 965 mm) above the walking surface must be not less than what minimum cross-sectional height?

1 1/2 inches (38 mm).

2406.4.3

Concrete shall not be placed through water unless a tremie or other method is used that is:

approved by the building official

1808.8.3

An emergency escape and rescue opening with the bottom of the clear opening below the adjacent grade shall be provided with an area well having a minimum horizontal area of 9 square feet (0.84 m2) and a horizontal projection and width of not less than:

36 inches (914 mm)

1031.5.1

According to Table 903.2.5.2, what is the required Occupancy Hazard Classification for Storage rooms with dispensing in a Group H-5 occupancy?

Extra Hazard Group 2

Table 903.2.5.2

Prior to commencement of vertical construction of Type III, IV or V buildings utilizing combustible materials, and having a fire separation distance less than 30 feet from property lot lines, what is the required minimum water supply?

A minimum of 500 gpm, or the entire fire flow required for the building when constructed, whichever is greater

3313.3.1

In other than dwelling units, the smooth, hard, nonabsorbent vertical base at the intersection of toilet room floors and walls shall extend upward onto the walls not less than:

4 inches (102 mm)

1210.2.1

What is the required fire-resistance rating for enclosures of machine rooms, control rooms, control spaces, and machinery spaces outside of the hoistway enclosure?

Not less than the required rating of the hoistway enclosure served

3005.4

What components are NOT permitted to be used as a component of a required means of egress from any other part of the building?

Elevators, escalators and moving walks

1003.7

The design of vertical glazing shall be based on Equation 24-1, where the wind load (Fgw) is factored by:

0.6

2404.1, 2404.1

Piping, fixtures, or equipment shall not be located in such a manner as to interfere with the normal operation of which three types of egress openings?

Windows, doors or other means of egress openings

2903.1.3

For a Group I-3 occupancy, where the corridor serves all occupants, what is the required fire-resistance rating for the corridor walls in a sprinklered building?

1 hour

Table 1020.2

According to Table 1404.3(5), for walls without a Class I, II, or III interior vapor retarder in Climate Zone 8, what is the minimum required R-value for continuous insulation on the exterior?

R-14

1404.3

For fireplaces with chimneys greater than 40 inches (1016 mm) wide, how many additional No. 4 vertical bars must be provided for each additional 40 inches (1016 mm) in width or fraction thereof?

two

2111.4.1

Detached one- and two-family dwellings are excepted from comprehensive seismic design requirements if they are assigned to which Seismic Design Categories?

A, B or C

1613.1 Exception 1

Gypsum panel products used in a horizontal diaphragm ceiling must be installed in what orientation relative to the ceiling framing members?

Perpendicular

2508.6.2

The design, manufacture, and use of open-web steel joists and joist girders must be in accordance with either SJI 100 or what other standard, as applicable?

SJI 200

2207.1

Roof coverings installed on low-slope roofs shall resist impact damage based on the results of tests conducted in accordance with ASTM D3746, ASTM D4272 or:

the "Resistance to Foot Traffic Test" in FM 4470

1504.7

In other than Group H occupancies, the force required to set a power-operated door in motion manually shall not exceed:

50 pounds (220 N)

1010.3.2

Where the fireplace opening is 6 square feet (0.557 m2) or larger, the hearth extension shall extend not less than 20 inches (508 mm) in front of, and not less than what minimum distance beyond, each side of the fireplace opening?

12 inches (305 mm)

2111.11

The fire separation distance between a building with polypropylene siding and the adjacent building must be not less than:

10 feet (3048 mm)

1403.11.2

Structural observations must be provided for structures classified as Risk Category III or:

IV.

1704.6.1 Item 1

For buildings more than two stories above grade plane, the minimum width of the yard must be increased at the rate of 1 foot (305 mm) for each additional story, up to a maximum number of stories based on:

14 stories above grade plane

1205.2

For a stage requiring emergency ventilation via roof vents, the aggregate clear opening area of the vents must be not less than what percentage of the area of the stage?

5 percent

410.2.7.1

Factory-built or masonry fireplaces must be equipped with an exterior air supply unless the room is mechanically ventilated and controlled so that the indoor pressure is:

neutral or positive

2111.14

Interior exit stairways and ramps shall have a fire-resistance rating of not less than 2 hours where connecting how many stories or more?

four

1023.2

In buildings with an occupied floor more than 120 feet (36 576 mm) above the lowest level of fire department vehicle access, fire service access elevators shall have a capacity of not less than:

3,500 pounds (1588 kg)

403.6.1

Interior floor-wall base that is 6 inches (152 mm) or less in height shall be tested in accordance with Section 804.2 and shall be not less than:

Class II

806.7

Awnings installed on detached one- and two-family dwellings are exempt from which specific fire requirements?

The fire propagation performance and flame spread index requirements.

3105.3 Exception

In moist (A) or marine (C) climate zones, if a drainage space or drainage material is required in addition to the layers required in Section 2510.6.1, what is the minimum required depth of that space or material?

3/16 inch (4.8 mm)

2510.6.2

What is the maximum allowable building height in feet for a nonsprinklered (NS) building classified as Group H-1 of Type IB construction?

160

Table 504.3

If a building is equipped throughout with an automatic sprinkler system and Class I materials are required, which materials are permitted instead?

Class II materials

804.4.2 Exception

Foundations for buildings and structures founded on expansive soils must be designed in accordance with Section 1808.6.1 or 1808.6.2, UNLESS the building official approves stabilization of the soil in accordance with:

Section 1808.6.4

1808.6 Exception 2

Where panic or fire exit hardware is installed, the actuating portion of the releasing device shall extend not less than what proportion of the door leaf width?

one-half

1010.2.8.3

Emergency power systems and standby power systems required by this code or the International Fire Code must be installed in accordance with the International Fire Code, NFPA 70, NFPA 110, and which other NFPA standard?

NFPA 111

2702.1.3

For the purposes of this classification, where an accurate boiling point is unavailable for a liquid or mixture, what is used as the boiling point?

The 20-percent evaporated point of a distillation performed in accordance with ASTM D86

202 [F] Boiling Point

What is the assumed maximum presumptive load-bearing value (in pounds per square foot) for public-occupancy temporary structures supported on a pavement, slab on grade, or other collapsible or controlled low-strength substrate soils?

1,000 pounds per square foot (47.88 kPa).

3103.6.2

Insulated metal panel (IMP) systems used as exterior wall covering systems shall be designed and constructed to resist wind loads as required by which section?

Section 1609

1409.2.2

What is the Tabular allowable area factor in square feet for a building classified as Group A-1, one story above grade plane (S1) of Type VB construction?

22,000

Table 506.2

Can the automatic means used to disconnect the main line power supply to an elevator due to sprinkler activation be self-resetting?

No

3005.5

According to Table 1504.2, for a maximum allowable stress design wind speed (Vasd) of 90 mph, what is the required ASTM D3161 or UL 7103 classification for steep slope roof shingles?

A, D or F

1504.2

Metal roof shingles shall not be installed on roof slopes below what minimum units vertical in 12 units horizontal?

3 units

1507.5.2

For noncombustible membranes used as a roof or skylight of any building, what is the minimum height required above any floor, balcony, or gallery?

Not less than 20 feet (6096 mm).

3102.6.1

What must protect openings in pedestrian barriers?

Doors that are normally kept closed

3306.5

Where textile wall coverings are tested in accordance with the Method B protocol of NFPA 265, flashover is NOT permitted to occur, and the total smoke release shall not exceed:

1,000 m2

803.5.1.1

The minimum thickness of fireplace hearths shall be:

4 inches (102 mm)

2111.10.1

An automatic sprinkler system is required for all enclosed Group A-5 accessory use areas in excess of:

1,000 square feet (93 m2)

903.2.1.5

Reinforcement larger than what size must be spliced using mechanical connections in accordance with Section 6.1.7.2 of TMS 402?

No. 9 (M #29)

2107.3

Educational Group E occupancy includes the use of a building by six or more persons at any one time for educational purposes through which grade?

12th grade

305.1

Exposed combustible trim and sheathing may abut masonry chimney sidewalls if the combustible trim or sheathing is not less than 12 inches (305 mm) from the inside surface of the nearest flue lining, and combustible material and trim shall not overlap the corners of the chimney by more than:

1 inch (25 mm)

2113.19 Exception 3

For anchor bolts attaching a wood sill plate to concrete, anchor bolts must be embedded into concrete not less than:

7 inches (178 mm)

1905.7.2 Exception 1.3

The design of cold-formed steel diaphragms must be in accordance with additional provisions of which standard, as applicable?

AISI S310

2204.1

Ambulatory Care Facility refers to a building used to provide care on a less than 24-hour basis to persons who are rendered incapable of self-preservation by the services provided or staff has accepted responsibility for:

Care recipients already incapable

202 [BG] Ambulatory Care Facility

What is the required interior wall and ceiling finish classification for interior exit stairways and ramps in a nonsprinklered Group R-2 occupancy?

Class B

Table 803.13

Type 1 mechanical splices are prohibited from being used within a plastic hinge zone or within a beam-column joint of intermediate or special reinforced masonry shear walls, but what type of mechanical splice is permitted in any location within a member?

Type 2

2108.3

Wood joists or structural floors that are closer than 18 inches to the exposed ground in crawl spaces, or wood girders that are closer than what minimum distance to the exposed ground, must be of naturally durable wood or preservative-treated wood?

12 inches (305 mm)

2304.12.1.1

Emergency power systems provided for exit signs must be capable of powering the required load for a duration of not less than how long?

90 minutes

2702.2.6

Structural plain concrete basement, foundation or other walls below the base are permitted in detached one- and two-family dwellings assigned to Seismic Design Category D or E, provided the height of the wall does not exceed 8 feet and the wall retains not more than what maximum height of unbalanced fill?

4 feet (1219 mm)

1905.6.2 Item 1

For determining deflection limits in Table 1604.3, the snow load is permitted to be taken as what factor multiplied by the design snow load determined in accordance with Section 1608.1?

0.7 times

1604.3

The fire service access elevator lobby must be separated from each floor with which type of fire barrier, except that lobby doorways must comply with Section 3007.6.3?

A smoke barrier in accordance with Section 709

3007.6.2

Exterior plastic veneer, other than plastic siding, shall not be attached to any exterior wall to a height greater than what maximum height above grade?

50 feet (15 240 mm)

2605.2

Guards are required at retaining walls located within 36 inches of walking surfaces where the walking surface is located more than what minimum vertical distance to the surface or grade below?

30 inches (762 mm)

1807.2.5.1

High-load diaphragms utilizing multiple rows of staples (Table 2306.2(2)) require the minimum nominal depth of framing members to be what minimum thickness?

3 inches nominal

2306.2(2)

Where the gradient of stepped aisles is to be the same as the gradient of adjoining seating areas, the riser height shall be not less than 4 inches (102 mm) nor more than:

8 inches (203 mm)

1030.14.2.2

Fasteners for asphalt shingles shall have a minimum 12-gage shank, a minimum 3/8-inch-diameter head, and be of a length to penetrate through the roofing materials and not less than what minimum distance into the roof sheathing?

3/4 inch (19.1 mm)

1507.2.5

A “cast-in-place concrete equivalent diaphragm” is defined as a cast-in-place noncomposite topping slab diaphragm, or a diaphragm constructed with precast concrete components that uses closure strips between precast components with detailing that meets the requirements of ACI 318 for the:

Seismic Design Category of the structure

1905.2

Adobe units must be laid with full head and bed joints and in full:

running bond

2109.2.4.2.2

Expansion joints not less than 1/4 inch wide shall be provided where thin exterior structural glass veneer abuts nonresilient material at sides or top, and horizontal joints shall be held to not less than what minimum distance by an approved nonrigid substance or device?

0.063 inch (1.6 mm)

1404.13.5

Inlets to masonry chimneys must enter from the side and must have a thimble of fireclay, rigid refractory material, or metal that will prevent the connector from pulling out of the inlet or from extending beyond the wall of the:

liner

2113.17

The egress analysis for evacuation of the five consecutive floors with the highest cumulative occupant load must demonstrate that the number of evacuation elevators results in an evacuation time less than what maximum duration?

15 minutes

3008.1.1

For a pair of fire doors in a storage or equipment room where the inactive leaf is not needed to meet egress capacity, which type of latching device is Permitted on the inactive leaf?

All three types are Permitted

Table 1010.2.4

What is the minimum required clearance in front of a water closet, urinal, lavatory, or bidet to any wall, fixture, or door?

21 inches (533 mm)

2903.1.1

Where the fire separation distance is 5 feet or less, the area of high-pressure decorative exterior-grade compact laminates (HPL) installed up to 40 feet in height above grade plane shall not exceed what maximum percentage of the exterior wall surface?

10 percent

1408.11.1.1

In Climate Zones 6, 7, and 8, the net free cross-ventilation area is permitted to be reduced to 1/300, provided at least what minimum percentage of the required venting area is provided by upper ventilators?

40 percent

1202.2.1 Exception

For the foam plastic spray applied in Type V construction (sill plate, joist header, and rim joist), the density of the foam plastic must be in what range?

1.5 to 2.0 pcf (24 to 32 kg/m3)

2603.4.1.13

The top surface of footings shall be level, and the bottom surface of footings shall be permitted to have a slope not exceeding:

1 unit vertical in 10 units horizontal

1809.3

For BIPV roof coverings installed in a high wind area (V ≥ 130 mph), mechanically fastened underlayment must be fastened with corrosion-resistant fasteners in a grid pattern of not greater than 12 inches horizontally and vertically between side laps, with what spacing at side and end laps?

6-inch spacing

1507.1.1

Special inspections for seismic resistance are not required for reinforced masonry or reinforced concrete structures where the design spectral response acceleration at short periods, does not exceed 0.5 and the building height does not exceed:

25 feet (7620 mm).

1705.13 Exception 2

Exterior window and door assemblies not covered in Section 1709.5.1 must be tested in accordance with ASTM E330, and each assembly must be tested for 10 seconds at a load equal to what factor multiplied by the design pressure?

1.5 times.

1709.5.2

Which standard governs belt manlifts?

ASME A90.1

Table 3001.3

A change in use of an elevator (e.g., from freight to passenger, or between freight classes) must comply with which standard and section?

Section 8.7 of ASME A17.1/CSA B44

3001.5

For a fire separation distance of 30 feet or greater, what is the allowable area for Unprotected, Nonsprinklered (UP, NS) openings?

No Limit

Table 705.9

Family or assisted-use toilet rooms shall be located not more than how many story above or below separate-sex toilet rooms?

one story

1110.2.1.4

Where the design area of the automatic sprinkler system in a Group H-5 occupancy consists of a corridor protected by one row of sprinklers, the maximum number of sprinklers required to be calculated is:

13

903.2.5.2

Not fewer than one layer of water-resistive barrier material must be attached to the studs or sheathing, and its intersection with fenestration openings shall be flashed and assembled in accordance with the:

fenestration manufacturer's installation instructions

1403.2

Institutional Group I-4 Day Care Facilities include buildings occupied by more than five persons of any age who receive custodial care for fewer than:

24 hours per day

308.5

In hospitals and rehabilitation facilities (Group I-2) that specialize in treating conditions that affect mobility, what percentage of the dwelling units and sleeping units shall be Accessible units?

100 percent

1108.5.4

When must an approved water supply for fire protection be made available?

As soon as combustible building materials arrive on the site

3313.1

For Factory and Industrial structures (fabricating, assembly, or processing), what is the required ratio for drinking fountains?

1 per 400

Table 2902.1

Where deep foundation elements stand unbraced in air, water or fluid soils, they shall be permitted to be considered laterally supported at a point 5 feet into stiff soil or what minimum distance into soft soil, unless otherwise approved?

10 feet (3048 mm)

1810.2.1

Concrete and clay roof tiles shall be tested to determine their resistance to overturning due to wind in accordance with Chapter 15 and either SBCCI SSTD 11 or which ASTM standard?

ASTM C1568

1504.3.1.1

According to Table 1507.4.3, what is the minimum thickness required for Aluminum used for roll-formed metal roof panels?

0.024 inch minimum thickness

1507.4.3

Vegetative roofs shall be installed in accordance with which standard?

ANSI/SPRI VF-1

1505.1

If a structure is located in a flood hazard area, what documentation must be submitted to the building official prior to the final inspection?

Documentation of the elevation of the lowest floor or dry floodproofing

110.3.12.1

Foundations placed below the active zone of expansive soil shall be designed to prevent uplift of the supported structure, and foundations penetrating expansive soils shall be designed to resist forces exerted on the foundation due to:

soil volume changes

1808.6.1 Item 2

Fire department connections to automatic sprinkler systems or standpipes must have threads that are compatible with the connections used by the:

Local fire department

901.4

In Climate Zone 4 (except Marine), use of a Class III vapor retarder is permitted only where the frame wall assembly complies with:

Table 1404.3(3)

1404.3

Foam plastic interior trim shall not constitute more than what maximum percentage of the specific wall or ceiling areas to which it is attached?

10 percent

2604.2.3

Group S-1 Moderate-Hazard Storage includes, but is not limited to, the storage of which of the following items?

Aerosol products, Levels 2 and 3

311.2

For a sprinklered space in Group H-4 or H-5 occupancy, what is the maximum common path of egress travel distance permitted in feet?

75

Table 1006.2.1

The design displacement shall be the Design Earthquake Displacement, defined in which section of ASCE 7?

Section 12.8.6.3

1902.1.1

Where a structure is proposed for a purpose that is not specified, it shall be classified in the occupancy it most nearly resembles based on the fire safety and:

Relative hazard

302.1

Where the difference in elevation is 6 inches (152 mm) or less in the means of egress, the ramp shall be equipped with either handrails or:

Floor finish materials that contrast with adjacent floor finish materials

1003.5

For horizontal vinyl siding installed on cold-formed steel light-frame construction, screw fasteners shall penetrate through the steel with not fewer than:

three exposed threads

1404.15.1.2

The accessible route from any separate-sex toilet room to a family or assisted-use toilet room shall not exceed what maximum distance?

500 feet (152 m)

1110.2.1.4

As construction progresses, to within one floor of what point must the temporary or permanent stairway be extended?

The highest point of construction having secured decking or flooring

3310.1

A dash bond coat applied to insufficiently rough masonry or concrete surfaces for proper bond must be mixed in proportions of not more than two parts volume of sand to one part volume of Portland cement or plastic cement and moist cured for not less than:

24 hours

2510.7

Slate shingles shall be secured to the roof with how many fasteners per slate?

Two

1507.7.6

Rooftop structures like towers or spires that are constructed of noncombustible materials are permitted to be:

Unlimited in height

504.3 Exception

What is the required separation and protection for a laundry room over 100 square feet that is located within a Group E occupancy?

1 hour or provide automatic sprinkler system

Table 509.1

Where elevator lobby exit access doors are electrically locked (Section 1010.2.14), activation of the building fire alarm system by means other than a manual fire alarm box shall automatically unlock the electric locks, and the electric locks shall remain unlocked until:

The fire alarm system is reset

1010.2.14 Item 3

In Dillingham, Alaska, what is the ground snow load in pounds per square foot required for a Risk Category IV building, according to Table 1608.2?

220 psf

1608.2

The fire command center must be provided with the means to manually initiate which phase of emergency recall for the occupant evacuation elevators?

Phase I Emergency Recall

3008.7.1

Exterior exit stairways shall not be used as an element of a required means of egress for buildings exceeding how many stories above grade plane or that are high-rise buildings?

six

1027.2

Which standard applies to the installation of gypsum panel products?

GA-216; ASTM C840

Table 2508.1

A Compressed Gas must be a gas at 68°F (20°C) or less at 14.7 psia (101 kPa) of pressure and have a boiling point of 68°F (20°C) or less at 14.7 psia (101 kPa), except those gases with no other health- or physical-hazard properties are not considered compressed until the pressure in the packaging exceeds:

41 psia (282 kPa)

202 [F] Compressed Gas

An open side of an exterior exit stairway must have not less than what minimum aggregate open area adjacent to each floor level and intermediate landing?

35 square feet (3.3 m2)

1027.3

In riverine flood hazard areas where design flood elevations are specified but floodways have not been designated, the proposed work shall not increase the design flood elevation more than what maximum distance?

1 foot (305 mm)

1612.3.2

Construction documents for buildings constructed using conventional light-frame provisions must include which wind design speed in accordance with Section 1609.3.1?

Allowable stress design wind speed

1603.1 Exception

Emergency power systems and standby power systems must be designed to provide the required power for a minimum duration of how long without being refueled or recharged, unless specified otherwise in this code?

2 hours

2702.1.5

Telecommunication and broadcast towers shall be designed and constructed in accordance with which standard?

TIA 222.

3108.1

Where accessible parking is provided, how many accessible spaces are required for a parking facility providing 750 total parking spaces?

2% of total (15)

Table 1106.2

The provisions governing the repair, alteration, change of occupancy, addition to and relocation of existing buildings are found in the:

International Existing Building Code

101.4.7

A water-resistive barrier coating complying with ASTM E2570 requires special inspection where installed over a:

sheathing substrate.

1705.17.1

For glass sloped 30 degrees (0.52 rad) or less from horizontal, the glass dead load (D) in psf is calculated as:

13 tg (where tg is total glass thickness in inches).

2404.2

According to Table 1607.1, what is the minimum uniformly distributed live load required for a dance hall or ballroom?

100 psf

1607.1

When shall the owner or owner’s authorized agent immediately remove walkways, debris, and other obstructions from public property?

On completion of the construction activity

3306.8

Do plumbing fixtures located in single-user toilet facilities (including family or assisted-use) contribute toward the total number of required plumbing fixtures for a building or tenant space?

Yes, they shall contribute

2902.1.2

Periodic special inspection shall be provided for seismic isolation systems during the fabrication and installation of isolator units and:

energy dissipation devices.

1705.13.8

What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) Group A-2 occupancy of Type IIIB construction?

2

Table 504.4

A day care facility within a dwelling unit having five or fewer children receiving day care shall be classified as which occupancy group?

Group R-3

305.2.3

What is the maximum occupant load permitted for accessory religious educational rooms or religious auditoriums to avoid being considered separate occupancies?

Less than 100 per room or space

303.1.4

Structural floor sheathing constructed of lumber placed perpendicular to supports (surfaced dry) must have a minimum net thickness of 3/4 inch when the maximum span is:

24 inches

2304.8(1)

Where lightning protection systems are installed, what other protective devices must also be installed in accordance with NFPA 70 and either NFPA 780 or UL 96A, as applicable?

Surge protective devices

2703.2.1

According to Table 1509.2, which ASTM standard applies to Aluminum-pigmented asphalt coating?

ASTM D2824

1509.2

In Types IV-A, IV-B, and IV-C construction, sealant or adhesive must be provided at abutting edges and intersections of mass timber building elements where those elements are required to be:

Fire-resistance rated

703.7

For structures assigned to Seismic Design Category C, D, E or F, the special inspector must examine designated seismic systems requiring seismic qualification and verify that the label, anchorage and mounting conform to the:

certificate of compliance.

1705.13.4

For steel storage racks that are 8 feet (2438 mm) in height or greater to the top load level and assigned to Seismic Design Category D, E, or F, what document must be submitted at the completion of installation?

A certificate of compliance

2209.3

Individual unstabilized adobe units are not permitted to have a compressive strength of less than:

250 psi (1724 kPa)

2109.2.1.1

What is the required interior wall and ceiling finish classification for rooms and enclosed spaces in a nonsprinklered Group I-1 occupancy?

Class B

Table 803.13

What is the maximum allowable building height in feet for a sprinklered (S) building classified as Group A, B, E, F, M, S, or U of Type VB construction?

60

Table 504.3

Except in Seismic Design Categories D, E and F, pier and curtain wall foundations are permitted to be used to support light-frame construction not more than how many stories above grade plane?

two stories

1809.1

A facility designed to be occupied solely as a storm shelter (dedicated storm shelter) shall be classified as which occupancy group for determinations other than those covered in ICC 500?

Group A-3

423.3.1

Compartmentation is required for an underground building having a floor level more than what depth below the finished floor of the lowest level of exit discharge?

60 feet (18 288 mm)

405.4.1

Required critical circuits must be protected using one of three listed methods, including cables listed in accordance with UL 2196 having a minimum fire-resistance rating of how long?

1 hour

2702.3

Glass used in a handrail or a guard must be laminated glass constructed of fully tempered or heat-strengthened glass and shall have a minimum nominal thickness of:

1/4 inch (6.4 mm).

2407.1

Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed what maximum weight?

15 pounds (67 N)

1010.1.3

The breakout force of a revolving door not used as a component of a means of egress shall not be more than what maximum weight?

180 pounds (801 N)

1010.3.1.2

Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to:

individuals with disabilities

1103.1

What is the Frontage Increase Factor when a building that does not meet Section 507 requirements has 60 percent of its perimeter on an open space of 23 feet?

0.33

Table 506.3.3

What is the maximum nominal thickness of ice loads permitted to be used for the design of public-occupancy temporary structures for all risk categories?

0.5 inch (13 mm).

3103.6.1.5

To be classified as Class B material under ASTM E84 or UL 723 testing, an interior wall and ceiling finish must have a flame spread index (FSI) in what range?

26—75

803.1.2

What is the minimum required vertical clearance from the public right-of-way to the lowest part of any awning (including valances) that projects into the right-of-way below 8 feet in height?

Not less than 7 feet (2134 mm).

3202.2.3

A water closet, urinal, lavatory, or bidet shall not be set closer than what minimum distance from its center to any side wall, partition, vanity, or other obstruction?

15 inches (381 mm)

2903.1.1

A permit is required for an owner or owner’s authorized agent who intends to perform which of the following activities regarding a building or structure?

Change the occupancy

105.1

For the alternative separation method using glass, the glass must be protected by an automatic sprinkler system that, when actuated, shall completely wet what area?

The entire surface of interior sides of the wall or glass.

3104.5.2.2

Special inspections of mass timber elements in Types IV-A, IV-B and IV-C construction shall be in accordance with which table?

Table 1705.5.3.

1705.5.3

Periodic special inspection is required for fastening of wind-resisting components, including exterior wall covering and wall connections to roof and floor:

diaphragms and framing.

1705.12.3 Item 2

What is the required separation in hours between a sprinklered (S) Group I-2 occupancy and a sprinklered (S) Group A or E occupancy?

2

Table 508.4

Where stadiums, arenas and grandstands have how many fixed seats or more and provide audible public announcements, they shall also provide captions of those announcements?

15,000 fixed seats

1109.2.7.3

For installations greater than 40 feet above grade plane on Types I, II, III and IV construction, the metal composite material (MCM) system must be tested in accordance with and comply with the acceptance criteria of:

NFPA 285

1406.10.3

Float, wired, and patterned glass in louvered windows and jalousies shall be not thinner than nominal 3/16 inch (4.8 mm) and not longer than:

48 inches (1219 mm).

2403.5

Exterior walls of aircraft hangars located less than 30 feet (9144 mm) from lot lines or a public way shall have a fire-resistance rating of not less than:

2 hours

412.3.1

According to Table 414.5.1, what specialized safety measure is required for Division 1.2 explosives?

Barricade construction

Table 414.5.1

For plain concrete footings supporting walls in Seismic Design Category C, D, E or F, the footings must have not fewer than two continuous longitudinal reinforcing bars that are not smaller than:

No. 4

1905.6.2 Item 3

In Group A-1, A-2, A-3, or A-4 occupancies, if the building occupant load is greater than what threshold, accessible public entrances must have a power-operated door or a low-energy power-operated door?

300

Table 1105.1.1

What two phases of emergency operation must elevators be provided with, in accordance with ASME A17.1/CSA B44?

Phase I emergency recall operation and Phase II emergency in-car operation

3003.2

Where special inspections or tests are required by Section 1705, the statement of special inspections shall be prepared by the registered design professional in responsible charge, EXCEPT it may be prepared by a qualified person approved by the building official for construction not designed by a:

registered design professional.

1704.3 Exception

The glass in glass elevator car doors shall be not less than what minimum percentage of the total visible door panel surface area as seen from the car side of the doors?

60 percent.

2409.4.2

For anchored stone veneer with wood stud backing, what is the minimum thickness of cement grout that must be placed between the backing and the stone veneer?

1 inch (25 mm)

1404.8

For glass handrails and guards, calculated stresses for specified loads shall be less than or equal to 3,000 pounds per square inch (20.7 MPa) for heat-strengthened glass and less than or equal to what maximum value for fully tempered glass?

6,000 psi (41.4 MPa).

2407.1.1

Residential Group R-1 occupancies contain sleeping units where the occupants are primarily what nature?

Transient

310.2

Load-bearing wall and partition assemblies must sustain the test load both with and without:

window framing.

1709.4

In cooler and freezer walls, foam plastic up to 10 inches thick must have flash ignition and self-ignition temperatures of not less than what minimum temperatures, respectively?

600°F and 800°F (316°C and 427°C)

2603.4.1.2

Which building component is designated in Table 601 and may or may not be of fire-resistance-rated construction, with materials based on the building type of construction?

Building Element

202 [BG] Building Element

Anchor buildings of not more than three stories above grade plane with the same occupancy as mall tenants shall be separated from the mall building by:

2-hour fire barrier

402.4.2.2 Exception

In Whittier, Alaska, at an elevation of 100 feet, what is the ground snow load in pounds per square foot required for a Risk Category I building, according to Table 1608.2?

346 psf

1608.2

What types of systems are prohibited from being located in an elevator hoistway enclosure?

Plumbing and mechanical systems

3002.9

Mechanical-access enclosed parking garages shall be separated from other occupancies and accessory uses by not less than:

2-hour fire barriers

406.6.4.1

What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) building classified as Group E of Type VA construction?

1

Table 504.4

The cohesive/adhesive bond strength of the cured SFRM applied to floor, roof and wall assemblies and structural members must be not less than:

150 pounds per square foot (7.18 kN/m2).

1705.15.6

For 2-inch sawn tongue-and-groove decking, each piece must be toenailed at each support with one 16d common nail through the tongue and face-nailed with how many 16d common nails?

One

2304.9.4.2

Deep foundation elements standing unbraced in air, water or fluid soils must be classified as columns and designed as such down to the point where adequate lateral support is provided in accordance with:

Section 1810.2.1

1810.1.3

The walls and soffits within enclosed usable spaces under enclosed and unenclosed stairways must be protected by construction having a rating of 1-hour or the fire-resistance rating of the stairway enclosure, whichever is:

greater

1011.7.3

Dead-end corridors in sprinklered Groups B, E, F, I-1, M, R-1, R-2, S, and U shall not exceed what maximum length?

50 feet (15 240 mm)

1020.5 Exception 2

In a Group I-3 occupancy, the distance of travel to a door in a smoke barrier from any point in a room shall be not greater than:

200 feet (60 960 mm)

408.6.1

In standard roll-in-type showers designed for assisted bathing, wall-mounted folding seats shall:

not be installed

1110.2.3.4

A vapor retarder is not required for unheated storage rooms having an area of less than:

70 square feet (6.5 m2)

1907.4 Exception 2

Pedestrian walkways shall be designed and constructed in accordance with which sections?

Sections 3104.2 through 3104.9.

3104.1.1

Spiral stairways are permitted to be used as a component in the means of egress only within dwelling units or from a space not more than what maximum area?

250 square feet (23 m2)

1011.1

When calculating the means of egress for the mall, the occupant load factor (OLF) is not required to be less than:

30

402.8.2.2

What is the defined maximum size for a metal can or plastic container designed and intended to dispense an aerosol?

33.8 fluid ounces (1000 ml)

202 [F] Aerosol Container

Standby power provided for in-building 2-way emergency responder communication coverage systems must be capable of operating the system at 100-percent system operation capacity for a duration of not less than how long?

12 hours

2702.2.3

An Emergency Escape and Rescue Opening is an operable exterior window, door or similar device that provides for a means of escape and access for:

Rescue in the event of an emergency

202 [BE] Emergency Escape and Rescue Opening

Nonstructural concrete with a freeze-thaw exposure Class F0 must have a minimum specified compressive strength, of not less than:

2,500 psi (17.2 MPa)

1904.2

Where the design wind pressure for aluminum fascia exceeds 30 pounds per square foot, the top edge of the fascia is permitted to be secured using utility trim installed beneath the drip edge with snap locks punched into the fascia spaced not greater than:

6 inches (152 mm) on center

1412.7.2

When a flue is relined with a material not complying with Section 2113.11.1, the chimney must be plainly and permanently identified by a label attached to a wall, ceiling, or other conspicuous location adjacent to where the connector enters the chimney, which includes notice of the specific type or category of appliance and:

the type of fuel burned

2113.11.1.5

According to Table 1404.3(4), in Climate Zone 8, what is the minimum R-value of continuous insulation required over a 2×4 wall for use with a Class I or II responsive vapor retarder?

R-7.5

1404.3

For bearing wall structures, longitudinal ties shall be spaced at not greater than what maximum distance on center?

10 feet (3038 mm)

1616.3.2.1

Standby power for emergency voice/alarm communication systems must be provided in accordance with which NFPA standard?

NFPA 72

2702.2.4

In recreational boating facilities, where the total number of boat slips provided is 1,500, what is the minimum required number of accessible boat slips?

17

Table 1111.4.9.1

For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required thickness of plain concrete footings is permitted to be 6 inches, provided the footing does not extend more than what maximum distance on either side of the supported wall?

4 inches (102 mm)

1906.1

In structures with four or more dwelling units or sleeping units intended to be occupied as a residence, every unit intended to be occupied as a residence shall be a Type B unit for which occupancy group?

All Groups I-1, I-2, I-3 (where intended as residence) and R

1108.5.1.3, 1108.6.1.2, 1108.6.2.2.2, 1108.6.2.3.2, 1108.6.3.2, 1108.6.4.2

Emergency escape and rescue openings shall have a minimum net clear opening of:

5.7 square feet (0.53 m2)

1031.3.1

Impact protective systems must be tested for impact resistance for compliance with ASTM E1886 and ASTM E1996 and for design wind pressure for compliance with:

ASTM E330.

1709.5.3.1

Cleanout openings must be provided within what maximum distance of the base of each flue within every masonry chimney?

6 inches (152 mm)

2113.18

Where Section 1705.13 or 1705.14 specifies special inspections or tests for seismic resistance, the statement of special inspections must identify the designated seismic systems and:

seismic force-resisting systems.

1704.3.2

For buildings two stories or less above grade plane, what is the minimum required width of a yard?

3 feet (914 mm)

1205.2

Where public restrooms are visually screened from outside entry or exit doorways, visual screening is NOT required if the room is:

A single-occupant toilet room with a lockable door

1210.3 Exception

In Group R-1 occupancies, where 76 total dwelling units or sleeping units are provided, what is the total minimum required number of Accessible units?

5

Table 1108.6.1.1

According to Table 1607.1, what is the minimum uniformly distributed live load required for uninhabitable attics with storage in one- and two-family dwellings?

20 psf

1607.1

Structural clay tile for nonstructural use in fireproofing structural members and wall furring is excepted from meeting which requirement?

the compressive strength specifications

2103.1 Exception

Where the ground-water table is lowered and maintained at an elevation not less than 6 inches below the bottom of the lowest floor, the floor and walls shall be:

dampproofed

1805.1.3

Metal composite material (MCM) systems used as exterior wall covering or as elements of balconies and similar projections to provide cladding or weather resistance must comply with which sections?

1406.7 through 1406.13

1406.2

Unless otherwise specified, metal composite material (MCM) must have a flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in accordance with:

ASTM E84 or UL 723

1406.9

Flagpoles and similar structures located on rooftops shall not be required to be constructed of noncombustible materials and shall not be limited in:

height or number

1511.7.5

The length or height of any section of thin exterior structural glass veneer shall not exceed:

48 inches (1219 mm)

1404.13.1

For exposed aggregate plaster applied over concrete or masonry surfaces, what is the minimum overall thickness required?

1/2 inch (12.7 mm)

2513.4

For conditions not addressed by the fenestration manufacturer’s instructions, flashing of fenestration to the wall assembly shall comply with the instructions of the water-resistive barrier manufacturer, the flashing manufacturer, or one of two other approved methods, including:

a flashing design or method of a registered design professional

1404.4.1

Fiber-mat reinforced cementitious backer units used as an exterior substrate for the application of exterior finish materials must comply with:

ASTM C1325

1403.13

For helicopter landing areas less than 2,000 square feet (186 m2) in area on the roof of a building, the second means of egress is permitted to be a fire escape, an alternating tread device, or a:

Ladder

412.7.3

Where geotechnical investigations involve in-situ testing, laboratory testing, or engineering calculations, such investigations must be conducted by a:

registered design professional

1803.1

Artificial light shall be provided to achieve an average illumination of 10 footcandles (107 lux) over the area of the room at a height of what distance above the floor level?

30 inches (762 mm)

1204.3

Public-occupancy temporary structures assigned to which Seismic Design Categories are not required to be designed for seismic loads?

A and B.

3103.6.1.4

In a building designed as separated occupancies, the total building area for a building more than three stories above grade plane that is equipped throughout with an automatic sprinkler system (Section 903.3.1.2) shall not exceed an aggregate sum of the area ratios greater than:

4

506.2.2 Exception

Dry-stack masonry is prohibited in structures assigned to which Risk Category?

Risk Category IV

2114.2

Unlisted combustion air ducts for masonry fireplaces must be installed with a minimum 1-inch (25 mm) clearance to combustibles for all parts of the duct within what maximum distance of the duct outlet?

5 feet (1524 mm)

2111.14.4

Where doors serving rooms with electrical equipment rated 800 amperes or more are less than 25 feet (7620 mm) from the equipment working space, they shall not be provided with a latch or lock other than:

Panic hardware or fire exit hardware

1010.2.8.2

All portions of an unsprinklered refrigeration machinery room shall be within what maximum distance of an exit or exit access doorway?

150 feet (45 720 mm)

1006.2.2.2

Essential electrical systems for Group I-2 occupancies shall be in accordance with which section?

Section 407.11

2702.2.8

Detectable warnings are required on passenger transit platform edges bordering a drop-off and not protected by platform screens or guards, EXCEPT that they are not required at:

bus stops

1110.13 Exception

For exterior walls of buildings of Type I, II, III or IV construction of any height, if the wall is required to have a fire-resistance rating, what test standard must be used to substantiate that the fire-resistance rating is maintained?

ASTM E119 or UL 263

2603.5.1

An Automatic Flush Bolt is typically installed on which component of a pair of doors?

The inactive leaf

202 [BE] Automatic Flush Bolt

For plain concrete footings supporting walls in Seismic Design Category C, D, E or F, the reinforcing bars must have a total area of not less than what factor multiplied by the gross cross-sectional area of the footing?

0.002

1905.6.2 Item 3

For structures assigned to Seismic Design Category D, E or F, deep foundation elements on Site Class E or F sites must be designed and constructed to withstand maximum imposed curvatures from:

earthquake ground motions

1810.2.4.1

What is the minimum required clearance from the curb line for stanchions or columns that support awnings, canopies, marquees and signs?

Not less than 2 feet (610 mm) in from the curb line.

3202.3.1

At least one of each type of exercise machine and equipment shall be on an:

accessible route

1111.4.10

The design of cold-formed stainless steel structural members must be in accordance with which standard?

ASCE 8

2205.1

Fiber-cement lap siding having a maximum width of 12 inches must be lapped not less than:

1 1/4 inches (32 mm)

1404.17.2

Passenger elevators required to be accessible or serve as part of an accessible means of egress must comply with which sections?

Sections 1009 and 1110.10

3001.4

In Group R-3 occupancies and dwelling units in Group R-2, where an incline platform lift or stairway chairlift is installed, a clear passage width not less than what distance shall be provided?

20 inches (508 mm)

1011.2 Exception 3

According to Table 1404.2, what is the minimum nominal thickness required for steel (approved corrosion resistant)?

0.0149 inches

1404.2

A Flammable Liquid Class IA must have a flash point below 73°F (23°C) and a boiling point below:

100°F (38°C)

202 [F] Class IA

What special feature must be installed in each fire door assembly in the smoke barrier of an occupant evacuation elevator lobby?

A vision panel

3008.6.3.1

An approved agency must employ experienced personnel educated in conducting, supervising and evaluating tests and:

special inspections.

1703.1.3

According to Table 1507.2.8.2, what is the minimum required thickness for Aluminum valley lining material?

0.024 in.

1507.2.8.2

For conventional light-frame construction, average dead loads shall not exceed what maximum value for combined roof and ceiling, exterior walls, floors and partitions?

15 psf (718 N/m2)

2308.2.3

When using the Simplified Structural Design Procedure for single-unit containers, what is the value specified for the Overstrength factor?

2.5.

3114.8.5.2

If two or more elevators are controlled by a common operating system, and the standby power source is not of sufficient capacity to operate all elevators at the same time, what must happen after all elevators have returned to the designated level?

Not less than one elevator shall remain operable from the standby power source

3003.1.3

Raised thresholds and floor level changes greater than 1/4 inch (6.4 mm) at doorways shall be beveled with a slope not greater than:

One unit vertical in 2 units horizontal (50-percent slope)

1010.1.6

Amusement park structures, bleachers, and grandstands intended for viewing outdoor activities are classified as which Assembly Group?

Group A-5

303.6

Fire walls and their supports shall be designed to withstand a minimum horizontal allowable stress load of 5 psf in order to meet the structural stability requirements of:

Section 706.2

1607.16.2

The applicant must submit a statement of special inspections in accordance with Section 107.1 as a condition for:

permit issuance.

1704.2.3

Concrete tie beams for adobe exterior walls and interior load-bearing walls must be continuously reinforced with not fewer than how many No. 4 reinforcing bars?

two

2109.2.4.7.1

Is wiring and cables to control signals required to be protected if they do not serve Phase II emergency in-car operations for a fire service access elevator?

No

3007.8.1 Exception

Where deep foundations are used, the geotechnical investigation must include all of the items listed in Section 1803.5.5, including recommended center-to-center spacing of deep foundation elements and:

designation of bearing stratum or strata

1803.5.5

The Gross Floor Area calculation includes the area within the inside perimeter of the exterior walls, without deduction for closets, the thickness of interior walls, columns or other features, but is exclusive of:

Vent shafts and courts

202 [BE] Floor Area, Gross

The combined thickness of cement plaster coats applied to adobe masonry shall not exceed:

1 inch (25 mm)

2109.2.4.8.6

Where walls are set out or ceilings are dropped distances greater than 1 3/4 inches (44 mm) from a fire-resistance-rated surface, which class of interior finish material must be used?

Class A

803.15.2

According to Table 1507.9.8, what is the maximum weather exposure (in inches) permitted for 18-inch, Grade No. 2 preservative-treated taper sawn shakes of Southern yellow pine installed on a 4:12 pitch or steeper?

5.5

1507.9.8

Structural plain concrete walls below the base in dwellings assigned to Seismic Design Category D or E shall have a thickness of not less than:

7 1/2 inches (190 mm)

1905.6.2 Item 1

Food processing establishments and commercial kitchens that are not associated with dining facilities and have an area greater than 2,500 square feet (232 m2) are classified as which occupancy group?

Group F-1

306.2

If a building has 75 percent of its perimeter fronting on an open space of 40 feet, what is the frontage increase factor?

1.13

506.3.3

In Group B, M, or R-1 occupancies, if the building occupant load is greater than what threshold, accessible public entrances must have a power-operated door or a low-energy power-operated door?

500

Table 1105.1.1

What is the maximum unobstructed width permitted for pedestrian walkways?

Not greater than 30 feet (9144 mm).

3104.8

The number designating the floor level on stairway identification signs shall be not less than how many inches in height and located in the center of the sign?

5 inches (127 mm)

1023.9.1

The exterior wall assembly utilizing foam plastic insulation in Type I, II, III, or IV construction must be tested for vertical and lateral fire propagation and must comply with the acceptance criteria of which standard?

NFPA 285

2603.5.5

A claim filed with the board of appeals must be based on a claim that the true intent of this code has been incorrectly interpreted, the provisions of this code do not fully apply, or that:

An equivalent or better form of construction is proposed

113.2

Approved agencies for smoke control testing must have expertise in fire protection engineering, mechanical engineering and certification as:

air balancers.

1705.19.2

Vertical and lateral flame propagation requirements apply to exterior walls on buildings of Type I, II, III and IV construction that contain a combustible exterior wall covering, combustible insulation or a combustible:

water-resistive barrier

1402.5

What minimum duration must the standby power for an auxiliary inflation system be capable of operating independently?

Not less than 4 hours.

3102.8.2

Ballasted, unattached PV panel systems shall be designed and installed only on roofs with slopes not more than:

1 unit vertical in 12 units horizontal

1613.4

For basic uniform live load reduction, the reduced design live load shall be not less than 0.50 L for members supporting how many floors?

one

1607.13.1

What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group M of Type IIIB construction?

4

Table 504.4

What is the maximum period of time in any 1 year that vestibules and storm enclosures shall be erected as temporary encroachments?

Not exceeding 7 months.

3202.4

All lightning protection systems on a building or structure must be interconnected in accordance with NFPA 780 or which other standard, as applicable?

UL 96A

2703.3

For exterior exit stairways and ramps serving individual dwelling units of Group R-3, the minimum fire separation distance shall be not less than:

5 feet (1525 mm)

1027.5 Exception

An adult changing station shall be located on an accessible route such that a person is not more than two stories above or below the story with the adult changing station and the path of travel to such facility shall not exceed what maximum distance?

2,000 feet (609.6 m)

1110.4.4

Special inspections and tests for sprayed fire-resistive materials (SFRM) must be performed during construction with an additional visual inspection after the rough installation of electrical, mechanical, plumbing and:

automatic sprinkler systems.

1705.15

What is the wind load reduction factor for a public-occupancy temporary structure in Risk Category II with a service life of 10 years?

0.8.

Table 3103.6.1.2

Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place, and what materials/conditions must generally be satisfied?

Any required forms shall be in place for concrete foundations

110.3.1

What fastening condition is permitted to be omitted at the top and bottom plates of vertical assemblies, or edges and ends of horizontal assemblies perpendicular to supports, and at the wall line?

Floating angles (fasteners at top and bottom plates/edges)

2508.3.1

What type of joint treatment must be provided for gypsum panel product fire-resistance-rated assemblies?

Joints and fasteners treated

2508.5

In an atrium containing an interior exit stairway, what is the maximum percentage of the total exit stairways permitted to be located in the same atrium?

50 percent

404.1

Toilet facilities shall not open directly into a room used for what purpose?

The preparation of food for service to the public

2902.3.2

What is the maximum distance steps are permitted to project into the public right-of-way if they are guarded by approved devices not less than 3 feet (914 mm) in height or located between columns or pilasters?

Not project more than 12 inches (305 mm).

3202.2.1

Which standard governs cold-formed steel studs and track that are nonstructural?

AISI S220

Table 2506.2

Accessible vehicle spaces at electrical vehicle charging stations shall comply with the requirements for a van accessible parking space that is 132 inches (3350 mm) minimum in width with an adjoining access aisle that is what minimum width?

60 inches (1525 mm)

1107.2.2

What feature of conventional elevators is prohibited from being installed on elevator systems used for fire service access elevators?

Shunt Trip

3007.4

Standby power for special purpose horizontal sliding, accordion, or folding doors must have a capacity to operate not fewer than how many closing cycles of the door?

50

2702.2.18

Combustible framing must be not less than 2 inches from flues, chimneys, and fireplaces, and not less than what minimum distance away from flue openings?

6 inches (152 mm)

2304.5

For strength design of masonry, the design must comply with Section 2106 and the requirements of Chapters 1 through 7 and Chapter 9 of TMS 402, except that AAC masonry must comply with Chapters 1 through 7 and Chapter:

11

2108.1 Exception

For seating at tables, the measurement of required clear width of the aisle or aisle accessway shall be made to a line what distance away from and parallel to the edge of the table or counter?

19 inches (483 mm)

1030.13.1

What is the maximum number of tiers allowed for a Type IIB open parking garage utilizing ramp access?

8 tiers

Table 406.5.4

What is the minimum required depth for a water closet compartment utilizing a floor-mounted water closet?

60 inches (1524 mm)

2903.1.1

The proportion of lime in cement plaster coats applied to adobe masonry walls shall be not less than:

1 part lime to 4 parts cement

2109.2.4.8.6

For a space in Group A, E, or M occupancies, what is the maximum occupant load allowed for a single exit or exit access doorway?

49

Table 1006.2.1

According to Table 2114.4, what is the maximum allowable stress (psi) for compression in dry-stack masonry based on gross cross-sectional area?

45

2114.4

The maximum percentage of unprotected and protected openings in Group R-3 occupancies shall be limited to:

25 percent

Table 705.9 Note d

Where more than one exit is required, the loss of any one exit or access to one exit shall not reduce the available capacity or width to less than what percentage of the required capacity or width?

50 percent

1005.5

In a building with occupant evacuation elevators, when is an additional exit stairway not required, even if Section 403.5.2 mandates it?

When occupant evacuation elevators complying with Section 3008.1 are provided

3008.1.2

For interior trim made of foam plastic insulation, what index is not limited by Section 2603.3?

Smoke-developed index

2603.3 Exception

In a safe dispersal area required because access to a public way cannot be provided, the area shall be of a size to accommodate not less than what minimum area for each person?

5 square feet (0.46 m2)

1028.5 Exception 1

In assembly areas with a seating capacity of 51 to 200, the minimum required number of receivers for the assistive listening system is 2, plus one receiver for every how many seats over 50 seats?

25

Table 1109.2.7.1

What is the minimum required fire-resistance rating in hours for interior bearing walls in a Type VA building?

1

Table 601

What is the maximum interval (in days) between follow-up inspections by a qualified person after initial occupancy of a public-occupancy temporary structure granted an extended period of service time?

Not exceeding 180 days.

3103.1.1

At least how many wheelchair spaces shall be provided in team or player seating areas serving areas of sport activity?

At least one wheelchair space

1111.4.2

Any portion of a masonry fireplace located in the interior of a building or within the exterior wall must have a clearance to combustibles of not less than 2 inches (51 mm) from the front faces and sides, and not less than what minimum distance from the back faces?

4 inches (102 mm)

2111.12

The fire-resistance rating of primary structural frame and bearing walls is permitted to be reduced by 1 hour where supporting only a:

Roof only

Table 601, Footnote a

For detailed plain concrete structural walls, horizontal reinforcement must be provided at a maximum spacing of:

120 inches (3048 mm)

1905.5.1

The aggregate area of a mezzanine or mezzanines within a room shall be not greater than what fraction of the floor area of that room or space?

One-third

505.2.1

What is the minimum required height for barriers placed on the side of the walkway nearest the construction?

8 feet (2438 mm)

3306.5

A Flammable Gas Category 1B must have a lower flammability limit of more than 6 percent by volume of air, or a fundamental burning velocity of less than:

3.9 inches/second (99 mm/s)

202 [F] Category 1B

Where a single cover sheet and truss index sheet are combined and attached to the set of truss design drawings, which document must bear the seal and signature of the truss designer?

The single cover/truss index sheet

2303.4.1.4.1 Exception

Where access points for fire and smoke dampers are permanently identified on the exterior, the lettering must be not less than what height?

1/2 inch (12.7 mm)

717.4.2

Factory industrial uses that are not classified as F-2 Low Hazard, such as the manufacturing of furniture or appliances, shall be classified as which group?

Group F-1 Moderate Hazard

306.2

According to Table 1705.3, what specific action requires continuous special inspection for the welding of reinforcement?

Inspect welding of reinforcement for special moment frames, boundary elements of special structural walls and coupling beams.

Table 1705.3 Item 2.b

For membrane-covered frame structures, what element shall not be considered to provide lateral restraint when calculating the capacities of the frame members?

The membrane.

3102.7.1

An elevator is required as part of the accessible means of egress where a required accessible floor is how many or more stories above or below a level of exit discharge?

four

1009.2.1

What is the minimum required fire-resistance rating in hours for interior bearing walls in Type IV-HT construction when supporting more than two floors or more than a floor and a roof?

1

Table 601, Footnote g

Where open or spaced wood veneers are used, they shall not project more than what maximum distance from the building wall?

24 inches (610 mm)

1404.6

When using the alternative allowable stress design load combinations that include the counteracting effects of dead and wind loads, only what fraction of the minimum dead load likely to be in place during a design wind event shall be used?

two-thirds

1605.2

Which standard applies to the material for Glass mat gypsum backing panel?

ASTM C1178

Table 2506.2

In covered and open mall buildings, what is the maximum path of travel distance to required public and employee toilet facilities?

300 feet (91 m)

2902.3.4

For materials not specifically provided for in this code, the design strengths and permissible stresses must be established by tests as provided for in which section?

Section 1707.

1706.2

The maximum rise permitted for alternating tread devices used as a means of egress between floor levels or landings is:

20 feet (6096 mm)

1011.14

When different provisions specify different materials, methods of construction, or other requirements for a specific case, which requirement shall govern?

The most restrictive

102.1

Kitchens shall have a clear passageway of not less than what distance between counter fronts and appliances or counter fronts and walls?

3 feet (914 mm)

1208.1

When combustible building materials are delivered to a site, what is the maximum distance allowed between the fire hydrant used to provide the fire flow supply and the materials, as measured along an approved fire apparatus access lane?

500 feet (152 m)

3313.2

For sloped wired glass designed using Equation 24-4, the total load (Fg) must be less than what multiple of the nonfactored load (Fge)?

0.3 Fge

2404.3.2

At what vertical distance above the finished floor must the fire service access elevator symbol be installed?

Not less than 78 inches, and not more than 84 inches

3007.6.5

To be permitted under Section 803.5.2, textile wall coverings must have a Class A flame spread index and be protected by:

An automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2

803.5.2

A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than how many stories?

three

1023.9

What is the maximum allowable quantity (in cubic feet at NTP) for the use of Highly Toxic gas in open systems per control area?

20 (gaseous) or 4 (liquefied)

Table 307.1(2)

Foundation walls and other walls in which horizontal movement is restricted at the top shall be designed for what type of lateral soil pressure?

at-rest pressure

1610.1

Where handrails are not continuous between flights, the handrails shall extend horizontally not less than what distance beyond the top landing nosing?

12 inches (305 mm)

1014.7

According to Table 1405.1.1.1.2, if a combustible exterior wall covering has a tolerable level of incident radiant heat energy of 9.6 kW/m2 without exhibiting sustained flaming, what is the minimum required fire separation distance (in feet)?

9

1405.1.1.1.2

Where security barriers incorporate elements that cannot comply with accessible route requirements, the accessible route shall be permitted to be provided adjacent to security screening devices, allowing persons with disabilities to maintain visual contact with their personal items to the same extent provided:

others passing through the security barrier

1104.6 Exception

An accessible entrance is not required to which type of facility if the facility is not required to be accessible?

self-service storage facilities

1105.1.7 Exception

Floor-ceiling assemblies between dwelling units or sleeping units shall have an Impact Insulation Class (IIC) rating of not less than what value when tested in accordance with ASTM E492?

50

1206.3

The area of a single section of thin exterior structural glass veneer shall not exceed 10 square feet where that section is not more than 15 feet above the level of the sidewalk, and shall not exceed what maximum area where it is more than 15 feet above that level?

6 square feet (0.56 m2)

1404.13

Where terms are not defined in this code but are defined in the International Fire Code, such terms shall have the meanings ascribed to them as in:

Those codes

201.3

What type of room/space containing the operation or motion controller for elevator operation must be provided with an independent ventilation or air-conditioning system?

Elevator machine rooms, machinery spaces that contain the driving machine, and control rooms or spaces that contain the operation or motion controller

3005.2

Where a diaphragm is not permitted to be idealized as either flexible or rigid, the structure shall be analyzed and designed utilizing an envelope analysis of the structure using a flexible and rigid diaphragm analysis separately and designing each component for the:

more severe load condition

1604.4

In Type IV-A construction, the outside face of exterior walls of mass timber construction must be protected with noncombustible protection contributing a minimum assigned time of:

40 minutes

602.4.1.1

In Group I-2 occupancies, a timer shall be provided that automatically deactivates domestic cooking appliances within a period of not more than:

120 minutes

407.2.7

Standby or emergency power must be provided in laboratory suites located above the sixth story above grade plane or located in a story below grade plane in accordance with which section of the International Fire Code?

Section 5004.7

2702.2.13

What is the required interior wall and ceiling finish classification for rooms and enclosed spaces in a sprinklered Group R-2 occupancy?

Class C

Table 803.13

Light-transmitting plastics used as wall panels shall not be installed more than what maximum height above grade plane?

75 feet (22 860 mm)

2607.3

A Level 2 Aerosol Product has a total chemical heat of combustion greater than 8,600 Btu/lb (20 kJ/g) but less than or equal to:

13,000 Btu/lb (30 kJ/g)

202 [F] Level 2 Aerosol Products

The application of a new protective roof coating over an existing protective roof coating is permitted without tear off of existing roof coverings, provided the new coating is applied in accordance with the:

roof coating manufacturer's approved instructions

1512.3 Item 4

A Class I standpipe hose connection must be provided in the interior exit stairway and ramp having direct access from where?

The enclosed fire service access elevator lobby

3007.9

For exterior adhered masonry veneer installed with lath and mortar, the masonry veneer units shall be adhered to the scratch coat with a setting bed applied to create a full setting bed for the back of the masonry veneer units, resulting in a nominal:

3/8-inch setting bed

1404.11.1.4.3

Special inspections are not required for cold-formed steel light-frame shear walls where the sheathing is wood structural panel on only one side and the specified fastener spacing at the sheet edges is more than what maximum distance on center?

4 inches (102 mm).

1705.12.2 Exception 2

Wood members supporting concrete, masonry, or similar materials must be checked for the effects of long-term loading using the provisions of which standard?

ANSI/AWC NDS

2304.13

Where an occupiable roof is used by persons in addition to the occupants of the building, and the egress path passes through the building, means of egress requirements for the building shall be based on the sum of the occupant loads of the building plus the:

Outdoor areas

1004.7

Assembly occupancies with an occupant load of 500 or more located within a covered mall building shall have not less than what proportion of their required means of egress opening directly to the exterior?

One-half

402.8.4

Slate shingles shall only be used on slopes of what minimum units vertical in 12 units horizontal?

4 units

1507.7.2

Above-deck thermal insulation shall be permitted provided that such insulation is covered with an approved roof covering and passes the tests of UL 1256 or:

NFPA 276

1508.1

Recovering or replacing an existing roof covering shall not be required to meet the minimum design slope requirement of 1/4 unit vertical in 12 units horizontal for low-slope roof coverings if the roofs provide positive roof drainage and meet the requirements of Section 1608.3 and:

Section 1611.2

1512.1 Exception 1

Towers are required to be noncombustible, but what is the maximum height permitted for single free-standing poles used to support antennas that are not required to be noncombustible?

Not greater than 75 feet (22 860 mm).

3108.1 Exception

Wall pockets or crevices in which moisture can accumulate must be protected with caps or drips, or other approved means, as required in:

1404.4.2

1404.4.2

What is the required interior wall and ceiling finish classification for corridors in a sprinklered Group I-2 occupancy?

Class B

Table 803.13

The total thickness of base coat plaster applied to concrete ceilings shall be as set forth in ASTM C842 or ASTM C926. If the ceiling surfaces require more than the maximum permitted thickness, what additional step must be taken before plastering?

Metal lath or wire fabric lath shall be installed

2511.4

Where lockers constructed of combustible materials are used, the lockers must be considered to be interior finish and must comply with which section?

Section 803

806.8

Exterior Insulation and Finish Systems (EIFS) with drainage must have an average minimum drainage efficiency of what minimum percentage when tested in accordance with the requirements of ASTM E2273?

90 percent

1407.4.1

To be considered firmly supported, if the glass edge length is greater than 13 feet 6 inches (4115 mm), the deflection of the glass edge perpendicular to the pane shall not exceed 1/240 of the glass edge length plus:

1/4 inch (6.4 mm).

2403.3

For a fire barrier with a 2-hour required fire-resistance rating, what is the minimum required fire door assembly rating in hours?

1 1/2 hours

Table 716.1(2)

Where two or more buildings are provided above a horizontal assembly separating them from a Group S-2 parking garage below, how shall the upper buildings be regarded?

As separate and distinct buildings from each other

510.9

When can elements of an excavation retention system be removed or decommissioned?

Where adequate replacement support is provided by backfill or by the new structure

3307.2.2

In Group M occupancies, egress through stockrooms is permitted provided not more than what maximum percentage of the exit access is through the stockroom?

50 percent

1016.2 Item 2.2

Door closers, overhead doorstops, frame stops, power door operators, and electromagnetic door locks shall project into the door opening height not lower than what distance above the floor?

78 inches (1980 mm)

1010.1.1.1 Exception

According to Table 722.4.1(5), what is the minimum longitudinal reinforcement cover (in inches) required for a reinforced masonry lintel with a nominal width of 8 inches to achieve a 3-hour fire resistance?

1 3/4

Table 722.4.1(5)

For a building with occupant evacuation elevators, building areas shall not contain hazardous materials exceeding the maximum allowable quantities per what defined space?

Per control area

3008.1

Individual light-transmitting plastic roof panels shall be separated from each other by a distance of not less than what minimum distance measured in a horizontal plane?

4 feet (1219 mm)

2609.2

Sheet metal clamps, ties, or clips used to ensure a continuous load path where wall framing members are not continuous must be formed of galvanized steel or other corrosion-resistant material not less than what minimum base metal thickness?

0.0329 inch (0.836 mm)

2304.10.7

Atriums are NOT permitted in buildings or structures classified as:

Group H

404.1

The maximum allowable area of unprotected (UP, S) openings in a sprinklered building where the fire separation distance is 3 to less than 5 feet is:

15%

Table 705.9

Walls and partitions around an adult changing table shall have a smooth, hard, nonabsorbent surface to a height of not less than what minimum distance above the floor?

72 inches (1829 mm)

1210.2.3

The contractor’s written statement of responsibility, submitted prior to the commencement of work, must contain acknowledgement of awareness of the special requirements contained in the:

statement of special inspections.

1704.4

The minimum slope for lapped, nonsoldered seam metal roof panels without applied lap sealant shall be:

three units vertical in 12 units horizontal (25-percent slope)

1507.4.2

Swimming pools and tennis courts intended for viewing indoor sporting events and activities with spectator seating are classified as which Assembly Group?

Group A-4

303.5

In unvented attics in Climate Zones 1, 2, and 3 where only air-permeable insulation is used, a vapor diffusion port shall be installed not more than what distance from the highest point of the roof, measured vertically?

12 inches (305 mm)

1202.3 Item 5.2.1

The path of egress travel within and from technical production areas shall be not less than:

22 inches (559 mm)

410.5.3.5

A curb used for edge protection on a ramp run or landing shall be not less than what minimum height?

4 inches (102 mm)

1012.10.1

An adobe unit shall not contain more than three shrinkage cracks, and any single shrinkage crack shall not exceed 3 inches (76 mm) in length or what maximum width?

1/8 inch (3.2 mm)

2109.2.1.4

A partition live load is not required where the minimum specified live load is equal to or greater than:

80 psf (3.83 kN/m2)

1607.5 Exception

The maximum area permitted for each kiosk or similar structure or groupings thereof located within a mall is:

300 square feet (28 m2)

402.6.2

Where a combustible exterior wall covering is furred out from the exterior wall and forms a solid surface, the distance between the back of the exterior wall covering and the exterior wall shall not exceed what maximum distance, unless excepted by Section 718?

1 5/8 inches (41 mm)

1405.1.3

Special inspection of railing systems composed of structural steel elements is limited to welding inspection of welds at the base of:

cantilevered rail posts.

1705.2.1 Exception

If all or portions of the profiled steel panel elements of an intermodal shipping container are considered the seismic force-resisting system, design and detailing must be in accordance with the AISI S100 and ASCE 7, Table 12.2-1 requirements for which type of steel system?

Steel systems not specifically detailed for seismic resistance, excluding cantilever column systems.

3114.8.4.2

Where two or more toilet facilities are provided for each sex, how must the required number of lavatories be distributed?

Distributed proportionately to the required number of male- and female-designated water closets

2902.1.3

The path of egress travel to an exit shall not pass through more than how many adjacent stories?

one

1006.3.2

Special purpose horizontal sliding, accordion, or folding door assemblies permitted in the means of egress shall open to the minimum required width within what maximum time after activation of the operating device?

10 seconds

1010.3.3 Item 8

The width of joints between firebricks in a masonry firebox shall be not greater than:

1/4 inch (6.4 mm)

2111.6

Continuous concrete footings supporting light-frame construction walls of buildings three stories or less above grade plane are exempt from special inspections if the specified compressive strength is not more than:

2,500 psi (17.2 MPa).

1705.3 Exception 2.3

In auditoriums, theaters, concert or opera halls, the illumination at the walking surface is permitted to be reduced during performances by one of two methods, provided that the required illumination is automatically restored upon activation of a premises’:

fire alarm system

1008.2.1 Exception

The shear values listed in Table 2508.6 shall be reduced by what percentage for normal loading?

25 percent

Table 2508.6 Note a

Solid or hollow approved glass block shall not be used in fire walls, party walls, fire barriers, fire partitions, smoke barriers, or for:

load-bearing construction

2110.1.1

Private garages or carports that contain required accessible parking are required to comply with Chapter 11, even though they are classified as which occupancy type?

Group U

1103.2.4

Incidental uses are limited to those uses specified in which table?

Table 509.1

509.1

Foam plastic in plenums used as interior wall or ceiling finish, or interior trim, must exhibit a flame spread index of 25 or less and a smoke-developed index of 50 or less when tested in accordance with ASTM E84 or UL 723, and shall also be tested in accordance with NFPA 286 and meet the acceptance criteria of which section?

Section 803.1.1.1

2603.7

Roof replacement requires the removal of all existing layers of roof assembly materials down to the roof deck, EXCEPT where the existing roof includes two layers of self-adhered underlayment, the second layer may only be installed if the buildup of material at walls, valleys, roof edges, end laps and side laps does not exceed:

two layers

1512.2 Exception 3.3

According to Table 1705.2.6, what type of special inspection is required for the installation of rafter/beam flange braces and column flange braces in metal building systems?

Periodic special inspection.

Table 1705.2.6 Item 1

The base course under floors in basements must be not less than 4 inches in thickness and consist of gravel or crushed stone containing not more than what maximum percentage of material that passes through a No. 4 sieve?

10 percent

1805.4.1

Fire-retardant-treated wood shakes and shingles shall be treated by impregnation with chemicals by the full-cell vacuum-pressure process, in accordance with:

AWPA C1

1505.6

What is the Live Load Element Factor required for interior beams?

2

1607.13.1

What are the five acceptable methods for providing required elevator hoistway door protection?

An enclosed elevator lobby with fire partitions or a smoke-protective curtain assembly for hoistways, among others

3006.3

The last portion of the exit access leading to the exit on an exterior egress balcony may increase the total exit access travel distance by an additional amount up to:

100 feet (30 480 mm)

1017.2.1

A minimum clearance of 4 inches (102 mm) must be provided between the exterior surfaces of a concrete or masonry chimney for medium-heat appliances and what other material?

combustible material

2113.11.2.5

Mortar for use with adhered masonry veneer must conform to which section of TMS 402?

Section 13.3

2103.2.4

In-situ load tests shall be conducted in accordance with Section 1708.2.1 or 1708.2.2 and shall be supervised by a:

registered design professional.

1708.2

Nonstructural projections such as trim and similar decorative features are permitted to project into the required means of egress width not more than what distance on each side?

1 1/2 inches (38 mm)

1005.7.2

The minimum thickness of exterior walls in one-story adobe buildings shall be:

10 inches (254 mm)

2109.2.4.4

Walls or portions thereof that retain earth and enclose interior spaces and floors below grade must be waterproofed and dampproofed, with the exception of those spaces containing groups other than residential and institutional where such omission is not detrimental to the building or:

occupancy

1805.1

What is the minimum nominal dimension for wood furring strips installed over solid backing?

1 inch by 2 inches (25 mm by 51 mm)

2504.1.1 Exception

For foam plastic insulation used as part of a roof-covering assembly, the assembly must be a Class A, B or C roofing assembly when tested in accordance with ASTM E108 or which other standard?

UL 790

2603.6

Emergency and standby power must be provided in high-rise buildings as required in which section?

Section 403.4.8

2702.2.11

According to Table 1505.1, what is the minimum roof assembly fire classification required for Type IB construction?

Class B

1505.1

For enclosures for shafts, interior exit stairways, and interior exit ramps with a 2-hour required fire-resistance rating, what is the maximum permissible area for a door vision panel in square inches?

100 square inches

Table 716.1(2)

Where HPM gases or liquids are carried in pressurized piping above 15 pounds per square inch gauge (psig), what device must be provided?

Excess flow control

415.11.7.3

In high-rise buildings of Group A, B, E, I-1, M, or R-1 occupancies, a solid and continuous luminous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step, with a minimum horizontal width of:

1 inch (25 mm)

1025.2.1

On buildings of Type I, II, III or IV construction, mechanical equipment screens constructed of combustible materials are permitted if the fire separation distance is not less than 20 feet and the height of the screen above the roof deck shall not exceed:

4 feet (1219 mm)

1511.6.2

Where must directional signage indicating the route to the required public toilet facilities be posted?

In a lobby, corridor, aisle or similar space

2902.4.1

For machine rooms, machinery spaces, control rooms, and control spaces that do not abut and do not have openings to the hoistway enclosure they serve, what is the permitted fire-resistance rating reduction for other than fire service access elevators and occupant evacuation elevators?

1-hour fire-resistance rating

3005.4 Exception 1

Emergency ventilation shall be provided for stages larger than 1,000 square feet (93 m2) in floor area, or with a stage height greater than:

50 feet (15 240 mm)

410.2.7

Concrete foundations must be protected from freezing during depositing and for a period of not less than:

5 days thereafter

1808.8.4

The L Rating for a fire-resistant joint system is tested in accordance with UL 2079, while the L Rating for a through-penetration firestop system is tested in accordance with:

UL 1479

202 [K] L Rating

When must the site safety plan be submitted and approved?

Before a building permit is issued

3302.1

Stationary emergency and standby power systems generators required by this code shall be listed in accordance with which UL standard?

UL 2200

2702.1.1

In employee and public toilet rooms, where must the required lavatory be located relative to the required water closet?

In the same room as the required water closet

2903.1.2

An automatic sprinkler system is required throughout all buildings containing a Group S-1 fire area used for the storage of commercial motor vehicles where the fire area exceeds:

5,000 square feet (464 m2)

903.2.9

What is the maximum exit access travel distance in feet for a nonsprinklered Group A, E, F-1, M, R, or S-1 occupancy?

200

Table 1017.2

According to Table 1404.3(1), which class of vapor retarder has a perm rating of less than or equal to 0.1?

Class I

1404.3

What is the required minimum clearance between foam plastics installed above grade and exposed earth in areas of heavy termite infestation probability?

6 inches (152 mm)

2603.8

When an escalator shutter begins to close, what operational requirement must be met?

Escalators shall cease operation

712.1.3.2

In nonsprinklered buildings of Group I-3 occupancy, what is the required interior finish classification for corridors and enclosures for exit access stairways?

Class A

Table 803.13

For the alternate method of application of cement plaster, what percentage of the weight of the Portland cement is permitted to be calcium aluminate cement added to the mix?

15 percent

2512.8.1

When an automatic sprinkler system is provided in a covered mall building, the sprinkler protection for the mall shall be independent from that provided for:

Tenant spaces or anchor buildings

402.5

Masonry design must comply with the provisions of TMS 402, TMS 403, or:

TMS 404

2101.2

Special inspections are not required for wood shear walls where the specified fastener spacing at panel edges is more than what maximum distance on center?

4 inches (102 mm).

1705.12.1 Exception

What is the minimum required separation in hours between a nonsprinklered (NS) Group R occupancy and a nonsprinklered (NS) Group I-4 occupancy?

NP

Table 508.4

In nonsprinklered buildings, foam plastic is permitted in walk-in coolers or freezer units without a thermal barrier if the foam plastic thickness does not exceed 4 inches, the maximum flame spread index is 75, and the aggregate floor area does not exceed what maximum size?

400 square feet (37 m2)

2603.4.1.3

Soil materials for geotechnical investigations must be classified in accordance with which ASTM standard?

ASTM D2487

1803.5.1

What is the maximum allowable number of stories above grade plane for a sprinklered (S) Group F-1 occupancy of Type IVA construction?

10

Table 504.4

The minimum net glazed area providing natural light shall be not less than what percentage of the floor area of the room served?

8 percent

1204.2

In cold storage buildings equipped throughout with an automatic sprinkler system, foam plastic insulation up to 10 inches thick is permitted, provided that when tested in a thickness of 4 inches (102 mm), it has a maximum flame spread index of 75 and a maximum smoke-developed index of 450. The sprinkler system must be provided in both the room and what other area of the building?

That part of the building in which the room is located

2603.3 Exception

Group A-3 buildings of Type II construction, one story above grade plane, used as a place of religious worship or gymnasium, are permitted unlimited area provided they do not have a stage other than a:

Platform

507.6

In attics or crawl spaces where entry is only for service of utilities, what is the minimum thickness of gypsum wallboard required to protect foam plastic insulation against ignition?

3/8 inch (9.5 mm)

2603.4.1.6

Clay and concrete tile shall be installed only over solid sheathing, EXCEPT that spaced lumber sheathing shall be permitted in which Seismic Design Categories?

A, B and C

1507.3.1 Exception

Light-transmitting plastic diffusers used in a light-diffusing system that is not protected by an automatic sprinkler system shall not be installed in which occupancy groups?

Group I-2 and Group I-3

2606.7

For buildings in coastal high-hazard areas and coastal A zones, electrical, mechanical and plumbing system components shall not be mounted on or penetrate through exterior walls that are designed to break away under:

flood loads

1402.1

Equipment and appliances having an ignition source and located in a private garage must be elevated such that the source of ignition is not less than what distance above the floor surface?

18 inches (457 mm)

406.2.9.1

Where the total number of parking spaces provided is four or less, identification of accessible parking spaces is not required, EXCEPT for parking spaces required by which section?

1106.3

1112.1 Item 1 Exception

Each tenant space within a mall is required to be separated from other tenant spaces by a:

Fire partition complying with Section 708

402.4.2.1

What is the required separation and protection for incinerator rooms classified as an incidental use?

2 hours and provide automatic sprinkler system

Table 509.1

The maximum area permitted for residential aircraft hangars is:

2,000 square feet (186 m2)

412.4.5

Food processing establishments and commercial kitchens not associated with restaurants and similar dining facilities are classified as Group B if they are not more than what area?

2,500 square feet (232 m2)

304.1

Special inspections for wind resistance are required for buildings in wind Exposure Category C or D where basic wind speed, is what minimum speed?

140 mph (62.6 m/sec) or greater.

1705.12 Item 2

According to Table 1705.7, what type of inspection is required to verify element materials, sizes and lengths comply with the requirements for driven deep foundation elements?

Continuous special inspection.

Table 1705.7 Item 1

For high-rise buildings greater than 420 feet (128 m) in height, the minimum bond strength required for Sprayed Fire-Resistive Materials (SFRM) installed throughout the building shall be:

1,000 psf

Table 403.2.3

Where the design wind pressure for vinyl siding or insulated vinyl siding exceeds 30 pounds per square foot, compliance with Chapter 16 must be demonstrated by:

tests or calculations

1404.15

Construction work requiring special inspection or testing must remain accessible and exposed until:

completion of the required special inspections or tests.

1704.2.2

The continuous vertical bar required beside an opening in a detailed plain concrete structural wall is permitted to substitute for one of the two No. 5 bars required by which section of ACI 318?

Section 14.6.1

1905.5.1

The design, testing, and utilization of steel cantilevered storage racks made of cold-formed or hot-rolled steel structural members must be in accordance with which standard?

ANSI MH 16.3

2209.1

A 4-inch cube cut from a stabilized adobe unit shall not absorb more than what maximum percentage of moisture by weight when placed on a constantly water-saturated, porous surface for seven days?

2 1/2 percent

2109.2.2.2

What is the minimum required fire-resistance rating in hours for the primary structural frame in a Type IIA building?

1

Table 601

On buildings of Types I, II, III and IV-HT construction, combustible exterior wall coverings shall not exceed 10 percent of an exterior wall surface area where the fire separation distance is:

5 feet (1524 mm) or less

1405.1.1

Fire dampers installed in an assembly having a required fire-resistance rating of 3 hours or greater shall have a minimum damper rating of:

3 hours

Table 717.3.2.1

A pipe or outlet, fitted with a suitable quick-opening valve for discharging the contents of a roof tank in an emergency, shall be provided in the bottom or on the side near the:

bottom of the tank

1511.3.1

Encroachments 15 feet (4572 mm) or more above grade shall not be subject to what restriction?

Shall not be limited.

3202.3.3

In accordance with procedures, the official in charge of the enforcement agency shall be known as the:

building official

103.1

The design, fabrication, and erection of austenitic and duplex structural stainless steel must be in accordance with which standard?

AISC 370

2203.1

According to Table 1808.8.2, what is the minimum concrete cover required for cast-in-place deep foundation elements not enclosed by a steel pipe, tube or permanent casing?

2.5 inches

1808.8.2

Unstabilized adobe masonry walls must receive a weather protective exterior finish in accordance with which section?

Section 2109.2.4.8

2109.2.4.8.1

Where ultraviolet (UV) germicidal irradiation systems are provided, they shall be listed and labeled in accordance with which standard?

UL 8802

1211.1

What is the minimum design live load required for the entire structure of covered walkways?

150 psf (7.2 kN/m2)

3306.7

When must demolition construction documents and a schedule be submitted?

Where required by the building official

3303.1

The design, testing, and utilization of industrial steel work platforms must be in accordance with which standard?

MHI ANSI/MH 28.3

2212.1

In court sports, at least how many accessible routes shall directly connect both sides of the court?

at least one accessible route

1111.4.4

Which alternative allowable stress load combination is represented by 0.9D + E/1.4?

Equation 16-6

1605.2

Protection of joints and penetrations in fire-resistance-rated assemblies, smoke barriers, and smoke partitions shall not be concealed from view until inspected and:

Approved

110.3.8

What is the minimum required fire-resistance rating in hours for the primary structural frame in a Type IB building?

2

Table 601

What is the Tabular allowable area factor in square feet for a nonsprinklered (NS) building classified as Group B of Type IIIB construction?

19,000

Table 506.2

Which of the following is an example of an Anchored Masonry Veneer?

Veneer secured with approved mechanical fasteners

202 [BS] Anchored Masonry Veneer

Nails used for framing and sheathing connections with shank diameters between 0.099 inch and 0.142 inch must have a minimum average bending yield strength of:

100 kips per square inch (ksi)

2303.6

According to Table 1404.3(5), for walls without a Class I, II, or III interior vapor retarder in Climate Zone 4, what is the minimum required R-value for continuous insulation on the exterior?

R-4.5

1404.3

The edge thickness of plain concrete footings supporting walls of other than light-frame construction shall be not less than:

8 inches (203 mm)

1809.8

Where required, waterproofing for concrete floors shall be accomplished by placing a membrane of rubberized asphalt, butyl rubber, fully adhered/fully bonded HDPE or polyolefin composite membrane or not less than 6-mil polyvinyl chloride with joints lapped not less than:

6 inches (152 mm)

1805.3.1

For a Type IIA constructed aircraft hangar with a maximum single fire area of 20,000 square feet (1858 m2), what is the minimum required hangar classification for the fire suppression system?

Group II

Table 412.3.6

For braced wall panels in conventional light-frame construction assigned to Seismic Design Category D or E, what is the maximum distance a braced wall panel is allowed from each end of the braced wall line?

8 feet (2438 mm)

2308.10.1

When seismic loads are required, which seismic design parameter must be indicated on the construction documents?

The seismic importance factor

1603.1.5

How many exits or exit access doorways shall be provided from any space with an occupant load greater than 1,000?

Four

1006.2.1.1

Emergency power systems must automatically provide secondary power within what maximum time after primary power is lost, unless specified otherwise in this code?

10 seconds

2702.1.4

At beams and girders, thickness measurements of SFRM shall be made at how many locations around the beam or girder at each end of a 12-inch length?

nine.

1705.15.4.6

Protruding objects are permitted to reduce the height of the ceiling for not more than what percentage of the ceiling area of a means of egress?

50 percent

1003.3.1

In high-rise buildings more than 420 feet (128 m) in height, not fewer than how many standpipes or sprinkler express risers shall supply automatic sprinkler systems within each vertical water supply zone?

Two

403.3.1.2

In Group I-3 guard towers, a hatch or trap door used for means of egress shall be not less than 16 square feet (610 m2) in area and have dimensions of not less than what distance in any direction?

2 feet (610 mm)

408.3.3

Where dressing rooms, fitting rooms or locker rooms are provided, at least what percentage, but not less than one, of each type of use in each cluster provided shall be accessible?

5 percent

1110.17

The floor base and foundation perimeter drain must discharge by gravity or mechanical means into an approved drainage system that complies with the:

International Plumbing Code

1805.4.3

Where pay toilet facilities are installed, must they be counted toward the required minimum toilet facilities?

No, they shall be in excess of the required minimum

2902.3.5

Plaster applied to adobe masonry must be applied in not less than how many coats?

two

2109.2.4.8.3

Which type of power system is an acceptable alternative for installations that require standby power systems?

Emergency power systems

2702.1.7

Where mid-aisle handrails are provided in stepped aisles, there shall be an additional rail located approximately what distance below the handrail?

12 inches (305 mm)

1030.16.4

Periodic special inspection is required for the erection and fastening of exterior cladding, interior and exterior nonbearing walls and interior and exterior veneer in structures assigned to which Seismic Design Categories?

D, E or F.

1705.13.5

A covered mall building or an open mall building shall be provided with emergency power capable of operating the emergency voice/alarm communication system where the total area is greater than:

50,000 square feet (4645 m2)

402.7.3

According to Table 1404.3(3), in Climate Zone 5, what is the minimum R-value of continuous insulation required over a 2×4 wall to permit the use of a Class III vapor retarder?

R-5

1404.3

Semiconductor fabrication facilities where hazardous production materials (HPM) are used in excess of the Maximum Allowable Quantities shall be classified as which High-Hazard Group?

Group H-5

307.7

In Group I-1, Condition 2 occupancies, the required refuge area shall provide not less than what net square footage for each care recipient?

15 net square feet (1.4 m2)

420.6.1

What is the minimum required fire-resistance rating in hours for the roof construction in a Type IVC building?

1

Table 601

The design, testing, and utilization of industrial boltless steel shelving must be in accordance with which standard?

MHI ANSI/MH 28.2

2211.1

In Group R-2 apartment houses containing more than 20 dwelling units or sleeping units, at least what percentage but not less than one of the units shall be a Type A unit?

2 percent

1108.6.2.2.1

For business and mercantile classifications, a service sink is not required if the occupant load is what maximum number?

15 or fewer

2902.1 Note

Fire apparatus access roads required by the International Fire Code must be maintained clear of obstructions that reduce the width of the usable roadway to less than what minimum width?

20 feet (6096 mm)

3302.3

In flood hazard areas designated as Zone AO where a depth number is not specified on the map, the design flood elevation depth number shall be taken as being equal to:

2 feet (610 mm)

202 [BS] Design Flood Elevation

For a structure to successfully meet in-situ load test requirements, within 24 hours after removal of the test load, the structure must have recovered not less than what minimum percentage of the maximum deflection?

75 percent.

1708.2.2 Item 2

Service sinks shall not be required to be located in individual tenant spaces in a covered mall provided they are located within what maximum distance of travel of the most remote location in the tenant space?

300 feet (91 m)

2902.7

For buildings of construction types other than Type VB, what is the maximum area of a single pane of light-transmitting plastic glazing permitted to be installed above the first story above grade plane?

16 square feet (1.5 m2)

2608.2

Plastic signs affixed to the storefront of a tenant space facing a mall shall be limited to not more than what percentage of the wall area facing the mall?

20 percent

402.6.4.1

On buildings of Type I construction, the exterior walls and roofs of penthouses with a fire separation distance greater than 5 feet and less than 20 feet shall be permitted to have not less than what minimum fire-resistance rating?

1-hour fire-resistance rating

1511.2.4 Exception 1

What is the maximum allowable building height in feet for a building classified as Group H-4 of Type IVC construction that is equipped throughout with an automatic sprinkler system (S)?

85

Table 504.3

Detached one- and two-family dwellings and townhouses, less than or equal to three stories above grade plane, are permitted to be constructed in accordance with which standard, subject to the limitations therein?

AISI S230

2206.1.2

Where restricted entrances are provided to a building or facility, at least how many restricted entrances shall be accessible?

at least one

1105.1.4

What is the Tabular allowable area factor in square feet for a building classified as Group F-2, two or more stories above grade plane (SM) of Type IVA construction?

454,500

Table 506.2

What is the maximum allowable quantity (in pounds) for storage of Corrosive materials (solid) per control area?

5,000 pounds

Table 307.1(2)

For cold-formed steel light-frame construction seismic force-resisting systems in Seismic Design Category C, D, E or F, periodic special inspection is required for welding operations and:

screw attachment, bolting, anchoring and other fastening.

1705.13.3

Chimney flues connected to more than one appliance shall be not less than the area of the largest connector plus what minimum percentage of the areas of additional chimney connectors?

50 percent

2113.15

What is the exception regarding elevator car doors and hoistway doors during Phase I Emergency Recall Operation?

The elevator car doors and associated hoistway doors at the floor level designated for recall shall be permitted to remain open

3002.1.1 Exception

Tempered spandrel glass shall be provided with what type of identification by the manufacturer?

A removable paper marking.

2403.1

Welded splices are prohibited in what specific zones of intermediate or special reinforced masonry walls?

plastic hinge zones

2108.3

If sufficient technical data is submitted to the building official for research and investigation, the costs, reports and investigations required under these provisions must be paid by the owner or the:

owner's authorized agent.

1703.4.1

For manual revolving doors with a maximum nominal diameter of 8 feet, what is the maximum allowable revolving door speed in RPM?

10

Table 1010.3.1(1)

Fiber-cement siding must conform to the requirements of ASTM C1186, Type A, or:

ISO 8336, Category A

1403.9

Where an occupiable roof has an assembly occupancy, automatic sprinkler system protection is required on all floors between the occupiable roof and the level of exit discharge if the occupant load exceeds 100 for Group A-2 and how many persons for other Group A occupancies?

300

903.2.1.5

Guards with structural glass balusters must have an attached top rail or handrail supported by not fewer than how many glass balusters, or be otherwise supported to remain in place should one fail?

three glass balusters

2407.1.2

Photovoltaic panels installed over open-grid framing or a noncombustible deck in elevated PV support structures must be tested, listed and labeled with a fire type rating in accordance with UL 1703 or with both UL 61730-1 and which other standard?

UL 61730-2.

3111.3.5.1

According to Table 1405.1.1.1.2, if a combustible exterior wall covering has a tolerable level of incident radiant heat energy of 5.2 kW/m2 without exhibiting sustained flaming, what is the minimum required fire separation distance (in feet)?

18

1405.1.1.1.2

The thickness of concrete floor slabs supported directly on the ground shall be not less than:

3 1/2 inches (89 mm)

1907.3

In enclosed attics and enclosed rafter spaces, what is the minimum required airspace between the insulation and the structural roof sheathing?

1 inch (25 mm)

1202.2.1

If a notice of violation is not complied with promptly, the building official is authorized to request the legal counsel of the jurisdiction to institute proceedings to restrain, correct, or:

Abate such violation

114.3

What plumbing components are permitted at the base of the hoistway enclosure?

Floor drains, sumps and sump pumps that are indirectly connected to the plumbing system

3002.9 Exception

Where equipment replacements and repairs must be performed in an emergency situation, when must the permit application be submitted to the building official?

Within the next working business day

105.2.1

For a cast-in-place deep foundation element, if the unsupported height to least horizontal dimension does not exceed three, it is permitted to design and construct the element as a:

pedestal

1810.1.3 Exception

Special inspections and nondestructive testing of structural steel elements must be in accordance with the quality assurance inspection requirements of:

AISC 360.

1705.2.1

Handrails and guards shall be designed to resist a concentrated load of not less than:

200 pounds (0.89 kN)

1607.9.1

In two-story, unlimited area buildings, Group H occupancies shall not be located more than one story above grade plane unless permitted by Section 504 height and story limits, and which condition is also required?

No additional condition specified

507.8.4

For fire service access elevators, in which specific locations are automatic sprinklers prohibited?

Machine rooms, machinery spaces, control rooms, control spaces and elevator hoistways of fire service access elevators

3007.2.1

Special inspections and tests for concrete construction are not required for isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on:

earth or rock.

1705.3 Exception 1

For aggregate-surfaced roofs in Exposure D, the required parapet height shall be determined by adding what minimum distance (in inches) to the parapet height required for Exposure C?

8 inches

1504.8

Flashing shall be installed at the perimeters of exterior door and window assemblies, penetrations, and terminations of exterior wall assemblies, exterior wall intersections with roofs, chimneys, porches, decks, balconies, and:

similar projections

1404.4

If an excavation is located 5 feet or less from the street lot line, what is the minimum required height of the barrier enclosing it?

6 feet (1829 mm)

3306.9

Where more than three washing machines are provided in accessible spaces, not fewer than how many shall be accessible?

two

1110.6.1

According to Table 1808.8.1, what is the minimum specified compressive strength (*f’*c) required for precast prestressed driven piles?

5,000 psi

1808.8.1

Fire areas used to avoid exceeding the limits for requiring a fire protection system must be separated by fire walls, fire barriers, or horizontal assemblies having a minimum fire-resistance rating determined by which section?

Section 707.3.10

901.7

What is the minimum thickness of masonry or concrete required to cover foam plastic insulation on each face when installed in a masonry or concrete wall, floor, or roof system to exempt it from thermal barrier requirements?

1 inch (25 mm)

2603.4.1.1

What is the minimum required dimension for an enclosed fire service access elevator lobby?

8 feet (2440 mm)

3007.6.4

Where lath on vertical surfaces extends between rafters or other similar projecting members, what must be installed to provide support for lath and attachments?

Solid backing

2510.5.1

Every stairway landing shall have a minimum depth, measured parallel to the direction of travel, equal to the width of the stairway or what maximum distance, whichever is less?

48 inches (1219 mm)

1011.6

For mechanically fastened underlayment in high wind areas, the cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than what minimum distance into the roof sheathing?

3/4 inch

1507.1.1

A care facility that provides accommodations for five or fewer persons receiving care is classified as which Residential Group?

Group R-3

310.4

In Group I-2 and I-3 occupancies, an Atrium is a vertical space connecting a minimum of how many stories?

Two or more stories

202 [BG] Atrium

What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) building classified as Group H-2 of Type IIB construction?

1

Table 504.4

What is the maximum size permitted for a glass bottle designed and intended to dispense an aerosol?

4 fluid ounces (118 ml)

202 [F] Aerosol Container

What is the maximum exit access travel distance in feet for a sprinklered Group H-1 occupancy?

200

Table 1017.2

Thickness testing of SFRM applied to structural members must be performed on not less than what minimum percentage of the structural members on each floor?

25 percent.

1705.15.4.5

All elevators must be equipped to operate with a standardized fire service elevator key in accordance with which code?

The International Fire Code

3003.3

The maximum allowable quantity for storage of Flammable Liquid Class IA (liquid) per control area is:

30 gallons

Table 307.1(1)

Glazing adjacent to a door is considered hazardous if the nearest vertical edge is within a 24-inch (610 mm) arc of the door edge, and the bottom exposed edge is less than what maximum height above the walking surface?

60 inches (1524 mm).

2406.4.2

A marquee must be supported entirely from which structure?

The building.

3106.5

Prescriptive concrete and masonry foundation walls must be designed and constructed in accordance with Section 1807.1.6 and must be laterally supported at the top and:

bottom

1807.1.6

The underground portion of an underground building shall be of which type of construction?

Type I

405.2

Under the Simplified Structural Design Procedure for single-unit containers, the intermodal shipping container must be located in which Seismic Design Categories?

Seismic Design Category A, B, C or D.

3114.8.5.1

In determining dead loads, the weight of fixed service equipment, including the maximum weight of the contents, shall be included. Components that are variable, such as liquid contents, shall not be used to counteract forces causing overturning, sliding, and:

uplift conditions

1606.3

Asphalt shingles shall have the minimum number of fasteners required by the manufacturer, but not less than how many fasteners per strip shingle?

Four

1507.2.6

Religious educational rooms and religious auditoriums accessory to places of religious worship with occupant loads of less than 100 per room shall be classified as which occupancy group?

Group A-3

305.1.1

Signage indicating “AREA OF REFUGE” or “EXTERIOR AREA FOR ASSISTED RESCUE” shall comply with ICC A117.1 requirements for visual characters and shall include what specific symbol?

The International Symbol of Accessibility

1009.9

According to Table 1705.5.3, what type of inspection is required for adhesive anchors installed in a horizontal or upwardly inclined orientation to resist sustained tension loads in mass timber construction?

Continuous special inspection.

Table 1705.5.3 (Adhesive anchors installed in horizontal or upwardly inclined orientation…)

For Group R-3 buildings of Type IIB or Type VB construction, the exterior wall is NOT required to have a fire-resistance rating where the fire separation distance is:

5 feet (1523 mm) or greater

Table 705.5 Note i

Where multiple-user facilities are designed to serve all genders, the minimum fixture count shall be calculated based on what percentage of the total occupant load?

100 percent

2902.1.1 Exception

Protruding objects are permitted to extend below the minimum ceiling height where a minimum headroom of what distance is provided over any circulation paths?

80 inches (2032 mm)

1003.3.1

For floor joists, holes bored in members shall not be within what minimum distance of the top or bottom of the member?

2 inches (51 mm)

2308.6.1

The design, detailing, fabrication, and erection of structural steel elements in seismic force-resisting systems other than those covered in Section 2202.2.1 must be in accordance with AISC 341 where the structure is assigned to Seismic Design Category D, E or F, except as permitted in which table?

ASCE 7, Table 15.4-1

2202.2.2 Item 1

Where a maximum one story above grade plane Group S-2 parking garage of Type I construction is provided under a building of Group R, the floor assembly between the parking garage and the Group R above shall provide a fire-resistance rating not less than the mixed occupancy separation required in which section?

Section 508.4

510.4

Glazing facing a swimming pool is considered hazardous if the bottom exposed edge is less than 60 inches (1524 mm) measured vertically above the standing surface, UNLESS the glazing is more than what minimum distance horizontally from the water’s edge?

60 inches (1524 mm).

2406.4.5

According to Table 1412.6, for a wood structural panel soffit (7/16 minimum performance category) with a maximum design pressure of ± 70 psf, what is the maximum fastener spacing permitted for stainless steel along edges and intermediate supports when using an 8d common nail?

4 inches

1412.6

The emergency voice/alarm communication system for a building with occupant evacuation elevators must be accessible to whom?

The fire department

3008.9

What is the minimum width required for a walkway provided for pedestrian travel in front of every construction and demolition site?

4 feet (1219 mm)

3306.2

Which of the following structures is specifically included in the Utility and Miscellaneous Group U classification?

Fences more than 7 feet (2134 mm) in height

312.1

For an unlimited area building, where Section 507.2 requires yards to be measured, how is the distance determined?

From the building perimeter to the closest interior lot lines or to the exterior face of an opposing building on the same lot

507.2

Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finished floor shall not project horizontally more than what distance into the circulation path?

4 inches (102 mm)

1003.3.3

When the sprinkler protection is being regularly turned off and on to facilitate connection of newly completed segments, when must the sprinkler control valves be checked?

At the end of each work period

3312.2

According to Table 1507.12.2, which material standard applies to Thermoplastic polyolefin (TPO) single-ply roof coverings?

ASTM D6878

1507.12.2

Every required interior exit stairway serving floors more than what height above the lowest level of fire department vehicle access shall be a smokeproof enclosure?

75 feet (22 860 mm)

403.5.4

Empirical design requirements for adobe masonry shall not apply to the design or construction of masonry where the Allowable Stress Design wind speed, exceeds what maximum speed?

110 mph

2109.1.1

According to Table 1705.3, what type of special inspection is required to inspect reinforcement, including prestressing tendons, and verify placement?

Periodic special inspection.

Table 1705.3 Item 1

For chimneys up to 40 inches (1016 mm) wide in Seismic Design Category C or D, how many continuous No. 4 vertical bars must be provided?

four

2113.3.1

According to Table 1610.1, what is the design lateral soil load for at-rest pressure (psf per foot of depth) for Inorganic clays of low to medium plasticity (CL)?

100

1610.1

The prepared surface of structural members to be sprayed with SFRM must be inspected by the special inspector before the application of the:

SFRM.

1705.15.2

Structural concrete slabs-on-ground are considered structural concrete where required by ACI 318 or where designed to transmit vertical loads or lateral forces from other parts of the structure to the soil or to:

foundations

1907.1

Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than:

5/8-inch Type X gypsum board

406.3.2.1

To qualify for the exemption allowance for corrosive consumer products in retail display, individual containers shall not exceed:

1.3 gallons

Table 307.1.1

An automatic sprinkler system shall be provided throughout all buildings with a Group R fire area and shall be installed in accordance with:

Section 903.3

903.2.8

According to Table 1404.2, what is the minimum nominal thickness required for marble slabs?

1 inch

1404.2

Plaster shall be applied when the ambient temperature is higher than what minimum temperature, unless provisions are made to keep cement plaster work above this temperature during application and 48 hours thereafter?

40°F (4°C)

2512.4

Packages and containers of foam plastic insulation must bear the label of an approved agency showing the manufacturer’s name, product listing, product identification, and what other information?

Information sufficient to determine that the end use will comply with the code requirements

2603.2

Deflagration is an exothermic reaction in which the reaction progresses through the unburned material at a rate less than the velocity of:

Sound

202 [F] Deflagration

For exterior nonbearing walls and partitions, the required fire-resistance rating is based on:

Fire separation distance (Table 705.5)

Table 601, Table 705.5

Glass in glazed curtain walls, glazed storefronts, and glazed partitions must meet the seismic requirements of which section of ASCE 7?

Section 13.5.9.

2404.1

According to Table 1807.1.6.2, for a 10-foot maximum wall height, 10-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft, what is the minimum vertical reinforcement required for an 11.5-inch minimum wall thickness?

#7 at 38 inches

1807.1.6.2

The tolerance between the largest and smallest riser height or between the largest and smallest tread depth shall not exceed what maximum distance in any flight of stairs?

3/8 inch (9.5 mm)

1011.5.4

Where seating or standing space is provided at fixed or built-in work surfaces, not less than what percentage of those spaces shall be accessible?

5 percent

1110.14.2

Allowable shear values for wood structural panel diaphragms utilizing staples (Tables 2306.2(1) and 2306.2(2)) are permitted to be increased by what percentage for wind design?

40 percent

2306.2

Handrails and guards shall be designed to resist a linear load of what minimum value in accordance with Section 4.5.1.1 of ASCE 7?

50 plf (0.73 kN/m)

1607.9.1.1

What is the maximum exit access travel distance in feet for a sprinklered Group F-2, S-2, or U occupancy?

400

Table 1017.2

According to Table 1404.15.2, for an ultimate design wind speed of 115 MPH (Case 1, with interior gypsum wallboard), what is the adjusted minimum design wind pressure (ASD) in psf required for vinyl siding installed over foam plastic sheathing alone in Exposure C?

-49.7

1404.15.2

According to Table 2304.6.1, for an 8d common nail (2.5″ x 0.131″) used with 7/16-inch wood structural panel sheathing, 16-inch stud spacing, 6-inch edge nailing, and 12d field nailing, what is the maximum basic wind speed (V) permitted in Wind Exposure Category C?

140 mph

2304.6.1, Table 2304.6.1

Stairways within dwelling units shall have an illumination level on tread runs of not less than:

1 footcandle (11 lux)

1204.4

For combustible core IMP installations greater than 40 feet in height above grade plane on Types I, II, III and IV construction, the system must be tested in accordance with and comply with the acceptance criteria of:

NFPA 285

1409.7.3.3

What is the maximum allowable building height in feet for a building classified as Group R (new) of Type IIIA construction that is equipped throughout with an automatic sprinkler system (S)?

85

Table 504.3

What is the tabular allowable area factor (At) for a Group H-2 occupancy of Type VB construction that is nonsprinklered (NS)?

3,000 square feet

Table 506.2

Which of the following occupancy groups is NOT permitted within a covered or open mall building or anchor building utilizing the reduced open space exception?

Group E

402.2 Exception

Masonry structures and components must comply with the seismic design requirements in Chapter 7 of TMS 402 depending on the structure’s:

seismic design category

2106.1

The required fire-resistance rating in hours for a fire barrier separating a single occupancy into fire areas for Group A, B, E, F-2, H-4, H-5, I, M, R, or S-2 is:

2 hours

Table 707.3.10

Light-transmitting plastic used for skylight glazing must be mounted on a curb not less than what minimum height above the plane of the roof?

4 inches (102 mm)

2610.2

The minimum depth of footings below the undisturbed ground surface shall be:

12 inches (305 mm)

1809.4

Vertical sandblasted glass (sloped 15 degrees or less from vertical) is designed to resist wind loads based on the nonfactored load (Fge) for what level of sandblasting?

Moderate levels of sandblasting.

2404.3.5

Where 10d common nails (3″ x 0.148″) are substituted for 16d common nails (3 1/2″ x 0.162″) in rafter tie heel joint connections, the required number of 10d nails must be what factor multiplied by the required number of 16d common nails, rounded up?

1.2 times

2308.11.3.1

If 3/8 inch wood structural panels are used for barriers, what is the maximum stud spacing permitted?

4 feet (1219 mm) on center

3306.6

A contrasting marking stripe shall be provided on each tread at the nosing or leading edge of a stepped aisle and shall be not less than 1 inch (25 mm) and not more than what maximum width?

2 inches (51 mm)

1030.14.2.3

For exterior adhered masonry veneer installed with lath and mortar, the scratch coat is created by scoring the surface horizontally of a nominal 1/2-inch-thick layer of mortar that is applied encapsulating the:

lathing

1404.11.1.4.2

Underlayment installed for BIPV roof panels where the allowable stress design wind speed (Vasd) is not less than 120 mph must comply with ASTM D226, Type III, ASTM D4869, Type IV or:

ASTM D6757

1507.17.4.1

A fire watch shall be provided during nonworking hours for construction that exceeds what minimum height above the lowest adjacent grade at any point along the building perimeter?

40 feet (12 192 mm)

3314.1

For an automatic or power-operated revolving door with a maximum nominal diameter of 12 feet, what is the maximum allowable revolving door speed in RPM?

4.8

Table 1010.3.1(1)

What fire propagation performance criteria must membranes and interior liners meet if they are not noncombustible?

Test Method 1 or Test Method 2, as appropriate, of NFPA 701 and the manufacturer's test protocol.

3102.3.1

Buildings housing special industrial processes requiring large areas and unusual building heights (e.g., rolling mills) shall be exempt from the building height, number of stories, and building area limitations specified in which sections?

Sections 504 and 506

503.1.1

In repair garages used for vehicles fueled by nonodorized gases, activation of a gas detection alarm shall result in the deactivation of all:

Heating systems located in the repair garage

406.8.2.1

Exterior wall assemblies on buildings of Type I, II, III or IV construction greater than 40 feet in height that contain an exterior wall veneer manufactured using a combustible adhesive to laminate a metal core must be tested in accordance with NFPA 285, with the adhesive level at the:

maximum application rate intended for use

1402.7

In a courtroom, a wheelchair space shall be provided within the jury box, but adjacent:

companion seating is not required

1109.4.1.1

What is the maximum allowable quantity (in gallons) for storage of Corrosive liquids per control area in Group M and S occupancies, where the building is equipped with an automatic sprinkler system? (Use Note b)

1,950 gallons

Table 414.2.5.1 Note b

Where more than the minimum number of drinking fountains is provided, what percentage of the total number provided shall comply with the requirements for persons who use a wheelchair?

50 percent

1110.7.2

For skylights rated for separate performance grades (PG_Pos and PG_Neg), if 0.6 times the outward wind force (Wo) is less than the dead weight of the glazing (D), what is the maximum required outward design load (Fgo) (Equation 24-15)?

0

2405.5.2

In a 0.5-hour fire partition, what is the minimum required fire window assembly rating in hours?

1/3

Table 716.1(3)

Where an interior exit stairway or ramp is extended by an exit passageway, the fire barrier separating the two components must have a fire-resistance rating not less than that required for the:

interior exit stairway and ramp

1023.3.1

Special inspections shall not be required for EIFS applications installed over a water-resistive barrier with a means of draining moisture to the:

exterior.

1705.17 Exception 1

Group H-1 occupancies shall be set back not less than what distance?

75 feet (22 860 mm)

415.6.4.1

Where cladding is installed directly over foam sheathing to wood framing using a 0.131-inch diameter nail, with a cladding weight of 18 psf and a fastener vertical spacing of 6 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.1 (assuming 16 inches on center horizontal spacing)?

1.2

1404.5.3.1

Where checkout aisles are provided, how many accessible checkout aisles of each function are required where the total number of checkout aisles of that function is 7?

2

Table 1110.16.1

Installation of exterior and interior cement plaster and lathing must be in compliance with ASTM C926 and which other standard?

ASTM C1063

2510.3

Group III aircraft hangars containing hazardous operations, such as hot work, require a Group I or Group II fire suppression system if the total fuel capacity of all aircraft within the unsprinklered single fire area is in excess of:

1,600 gallons (6057 L)

412.3.6.1

Under what condition are separate toilet facilities not required to be designated by sex?

Where single-user toilet rooms are provided in accordance with Section 2902.1.2

2902.2 Exception

The maximum distance of travel permitted between any point in a Group I-2 occupancy sleeping room (not in a care suite) and an exit access door in that room is:

50 feet (15 240 mm)

407.4.2

What is the maximum number of elevator cars permitted in any single fire-resistance-rated hoistway enclosure?

Four

3002.2

Plastic composite deck boards, stair treads, handrails and guards shall exhibit a flame spread index not exceeding 200 when tested in accordance with ASTM E84 or UL 723 with what condition applying to the test specimen?

It must remain in place during the test.

2612.3

Class A, B and C roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with UL 790 or:

ASTM E108

1505.1

In floodways, grading or fill shall not be approved unless it has been demonstrated that the proposed work will not result in any increase in flood levels during the occurrence of the design flood through hydrologic and hydraulic analyses performed by a:

registered design professional

1804.5 Item 2

For Group H-5 Higher education laboratories, what is the maximum percentage of the maximum allowable quantity permitted per lab suite located on floors 11 through 15 above grade plane?

50

Table 428.3

What is the maximum number of stories an unconcealed vertical opening totally within an individual residential dwelling unit can connect without requiring a shaft enclosure?

Four

712.1.2

The actual time that a person is an occupant within a facility for the purpose of receiving care is known as:

24-Hour Basis

202 [BG] 24-Hour Basis

Concrete and masonry chimneys for high-heat appliances must extend not less than 20 feet (6096 mm) higher than any portion of any building within what maximum distance?

50 feet (15 240 mm)

2113.11.3.3

Where minimum 1x wood furring is used to attach cladding over foam sheathing to a minimum 2x wood stud using a 0.131-inch diameter nail, with a cladding weight of 18 psf and a fastener spacing in the furring of 8 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.2 (assuming 16 inches on center furring)?

1.45

1404.5.3.2

Metal lath and lath attachments used for cement plaster shall be of what type of material?

Corrosion-resistant material

2510.4

Computations to determine the required sizes of wood structural members must be based on which dimensions?

Net dimensions (actual sizes)

2304.2

What is the maximum occupant load permitted on a first story above grade plane of a Group H-4, H-5, I, or R-1 occupancy served by a single exit?

10

Table 1006.3.3

The design of dry-stack masonry structures must comply with the requirements of Chapters 1 through 8 of TMS 402, except as modified by Sections 2114.2 through:

2114.5

2114.1

When tested in accordance with NFPA 286, the total smoke released by the interior finish throughout the test shall not exceed:

1,000 m2

803.1.1.1

Where HPM piping is installed in corridors, the required ventilation shall be not less than:

Six air changes per hour

415.11.7.4

Stair riser heights shall be 7 inches (178 mm) maximum and what minimum height?

4 inches (102 mm)

1011.5.2

Operable parts that are intended for use only by service or maintenance personnel are:

not required to be accessible

1110.18 Exception 1

Emergency and standby power must be provided in underground buildings as required in which section?

Section 405

2702.2.19

Walls and floor-ceiling assemblies separating dwelling units from each other shall have a Sound Transmission Class (STC) of not less than:

50

1206.2

Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanically ventilated in accordance with:

The International Mechanical Code

1202.5.2.1

For trusses spanning 60 feet or greater, who must contract a registered design professional for the design of the temporary installation restraint/bracing and the PITMR and PITMDB?

The owner or the owner's authorized agent

2303.4.1.3

Isolated poles not adversely affected by a 1/2-inch motion at the ground surface due to short-term lateral loads shall be permitted to be designed using lateral bearing pressures equal to what factor multiplied by the tabular values in Table 1806.2?

two times

1806.3.4

For passenger vehicle garages accommodating not more than nine passengers, the concentrated load of 3,000 pounds shall act on an area of:

4.5 inches by 4.5 inches (114 mm by 114 mm)

1607.7

Ambulatory care facilities must be separated from adjacent spaces where the potential for how many or more care recipients are to be incapable of self-preservation at any time?

Four

422.2

If a multiple occupant toilet room egress door is permitted to be lockable from inside by authorized personnel, the door must also be capable of being unlocked from outside with a key or what other means?

A key or other approved means

2902.3.6 Exception

In concrete frame structures, the reinforcing steel passing through the longitudinal column reinforcement shall have a minimum nominal tensile strength equal to two-thirds of the required one-way vertical strength of the connection of the floor or roof system to the column in each direction, unless the slabs have continuous reinforcement having an area not less than what factor multiplied by the concrete area?

0.0015

1616.2.1 Exception

In a Group I-2 care suite containing sleeping rooms, what is the maximum area permitted where an automatic smoke detection system is provided throughout the care suite?

10,000 square feet (929 m2)

407.4.4.6.1 Exception

Structural observations must meet the applicable requirements of this section, in addition to special inspections and tests, statements of special inspections, responsibilities of contractors, and submittals to the:

building official.

1704.1

Where provided, saunas and steam rooms are required to be accessible, EXCEPT where they are clustered at a single location, at least what percentage, but not less than one, of each type in each cluster shall be accessible?

5 percent

1110.9 Exception

At least what percentage of the total, but not fewer than one, of each gaming machine type and gaming table type shall be accessible?

2 percent

1110.19

When exterior wall assemblies are required to comply with the acceptance criteria of NFPA 285, compliance shall be established by testing, an approved design listed by an approved agency, or an approved analysis based on an assembly or condition tested in accordance with NFPA 285, as specified in:

Section 1402.8

1402.8

Wood tie beams in adobe construction must have a minimum width of not less than:

10 inches (254 mm)

2109.2.4.7.2

Employee work areas less than 300 square feet (30 m2) in area that are located 7 inches (178 mm) or more above or below the ground or finished floor are exempt from all accessibility requirements, provided the change in elevation is:

essential to the function of the space

1103.2.2

For a sprinklered space in Group R-2 occupancy consisting of dwelling units, what is the maximum common path of egress travel distance permitted in feet?

125

Table 1006.2.1

What is the required minimum fire-resistance rating for a smoke barrier?

1 hour

709.3

The area of covered and open mall buildings and anchor buildings not exceeding three stories in height that comply with Section 402 shall be:

Not limited

507.13

Experience or training of special inspectors is considered relevant where the documented experience or training is related in complexity to the same type of special inspection or testing activities for projects of:

similar complexity and material qualities.

1704.2.1

The nonresidential area function within a live/work unit shall be limited to which floor level(s)?

The first or main floor only

508.5.1

If a building has 50 percent of its perimeter fronting on an open space of 25 feet, what is the frontage increase factor?

0.42

506.3.3

Glass-block assemblies having a fire protection rating of not less than what minimum time shall be permitted as opening protectives in fire barriers, fire partitions, and smoke barriers that have a required fire-resistance rating of 1 hour or less?

3/4 hour

2110.1.1 Exception

In structures assigned to Seismic Design Category D or E, portions of floors or roofs that do not support braced wall panels above are permitted to extend up to what maximum distance beyond a braced wall line?

6 feet (1829 mm)

2308.10.8.2

The permanent open space of 60 feet (18 288 mm) for a covered mall building is permitted to be reduced to not less than 40 feet (12 192 mm) provided the exterior wall facing the reduced open space has a fire-resistance rating of not less than:

3 hours

402.2 Exception

When a Group B or M building below a horizontal assembly is of Type IB or II construction, but not less than the type of construction required for the Group S-2 open parking garage above, what is the maximum height permitted for the lower building?

Not greater than one story in height above grade plane

510.8 Exception

An exterior wall assembly must be constructed to prevent water accumulation by providing a water-resistive barrier behind the exterior veneer and a means for draining water that enters the assembly to the:

exterior

1402.2

For Group R-4 occupancies protected by an automatic sprinkler system installed in accordance with Section 903.3.1.3, the exit access travel distance shall be not more than what distance?

75 feet (22 860 mm)

1006.2.2.6

What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group I-4 of Type VA construction?

2

Table 504.4

According to Table 1404.2, what is the minimum nominal thickness required for vinyl siding?

0.035 inches

1404.2

Surface Roughness C, for the purpose of assigning an exposure category, is defined as open terrain with scattered obstructions having heights generally less than:

30 feet (9144 mm)

1609.4.2

For sensor release of electrically locked egress doors, the manual unlocking device must be clearly identified by a sign that reads:

"PUSH TO EXIT"

1010.2.11

Where pass-through openings are provided in smoke partitions in Group I-2, Condition 2 occupancies, the aggregate area of all such openings within a single room shall not exceed:

80 square inches (0.05 m2)

710.5.3

What is the minimum required net free ventilating area for enclosed attics and enclosed rafter spaces?

1/150 of the area of the space ventilated

1202.2.1

Intermediate nailing strips are required for vinyl and aluminum soffit panels where the unsupported span is greater than 16 inches and the design wind pressure is:

30 psf (1.44 kN/m2) or less

1412.3

Aggregate accessory occupancies shall not occupy more than what percentage of the floor area of the story in which they are located?

10 percent

508.2.3

Seismic reinforcing is not required within the body of a masonry heater if the height is equal to or less than what maximum multiple of its body width?

3.5 times

2112.4

For seismic force-resisting systems of structures assigned to Seismic Design Category C, D, E or F, continuous special inspection is required during:

field gluing operations.

1705.13.2 Item 1

The common path of egress travel shall not exceed 30 feet (9144 mm) from any point in a Group M merchandise pad, EXCEPT for areas serving not more than 50 occupants, where it shall not exceed:

75 feet (22 860 mm)

1018.4 Exception

For structures assigned to Seismic Design Category C, D, E or F, the ends of hoops, spirals and ties used in concrete deep foundation elements must be terminated with seismic hooks and shall be turned into the:

confined concrete core.

1810.3.2.1.1

For uninhabitable attics with storage, the attic area is accessed from an opening not less than 20 inches in width by 30 inches in length that is located where the clear height in the attic is not less than:

30 inches (762 mm)

1607.21.2

A water-resistive barrier material complying with ASTM E2556, Type I or II, shall be permitted as one of the required layers, provided the material complies with Section 1403.2 or is an:

approved material

1403.2

Which occupancy group classification shall live/work units be classified as?

Group R-2

508.5.2

Special inspections are not required for wood shear walls in the seismic force-resisting system where the specified fastener spacing at the panel edges is more than what maximum distance on center?

4 inches (102 mm).

1705.13.2 Exception

Adjacent combustible members entering into a concrete or masonry fire wall from opposite sides must have a distance between embedded ends of not less than:

4 inches (102 mm)

706.7

What must happen to an elevator machine room, control room, or control space with openings into a pressurized hoistway upon activation of a heat or smoke detector?

It shall be pressurized

3005.3

Separate toilet facilities shall not be required in mercantile occupancies where the maximum occupant load is what number or fewer?

100 or fewer

2902.2 Exception

If only one elevator is installed and standby power is required, how quickly must the elevator automatically transfer to standby power after failure of normal power?

Within 60 seconds

3003.1.2

Where the basic wind speed, V, is greater than 130 mph in Exposure B, nails attaching wood structural panel roof sheathing to gable-end roof framing within 48 inches of roof edges must be spaced at what maximum distance on center?

4 inches on center

2304.10.2

Where a toilet facility is provided for the use of multiple occupants, shall the egress door for the room be lockable from the inside (excluding family or assisted-use toilet facilities)?

No, shall not be lockable from the inside

2902.3.6

What is the minimum height required for a parapet above the point where the roof surface and the wall intersect?

30 inches (762 mm)

705.12.1

An Alternating Tread Device has a series of steps between 50 and 70 degrees from horizontal, which corresponds to what range in radians?

0.87 and 1.22 rad

202 [BE] Alternating Tread Device

Periodic special inspection shall be provided for the installation of cold-formed steel special bolted moment frames in structures assigned to which Seismic Design Categories?

D, E or F.

1705.13.9

Structural observations must be provided for a structure assigned to Seismic Design Category E if the structure is greater than:

two stories above grade plane.

1704.6.1 Item 3

Glazing adjacent to stairways and ramps is a hazardous location if the bottom exposed edge of the glazing is less than what maximum height above the plane of the adjacent walking surface?

60 inches (1524 mm).

2406.4.6

Emergency power for power-operated doors and locks in Group I-3 occupancies is required by which section?

Section 408.4.2

2702.2.9

Where two or more exits are required, not more than what fraction of the total number of exits or total exit minimum width/required capacity shall be horizontal exits?

One-half

1026.1

Appliances located in public garages or repair garages shall be installed not less than what height above the floor?

8 feet (2438 mm)

406.2.9.2

Staples used in contact with preservative-treated wood must be made of which material?

Stainless steel

2304.10.6.1

If a service entrance is the only entrance to a building or a tenant space in a facility, that entrance shall be:

accessible

1105.1.6

Inspection of fire-resistant joint systems tested and listed in accordance with Sections 715.3.1 and 715.4 must be conducted by an approved agency in accordance with:

ASTM E2393.

1705.18.2

Where checkout aisles are provided, how many accessible checkout aisles of each function are required where the total number of checkout aisles of that function is 18?

4

Table 1110.16.1

Compacted fill material 12 inches or less in depth is exempted from complying with an approved geotechnical report, provided that the in-place dry density is not less than 90 percent of the maximum dry density at optimum moisture content determined in accordance with:

ASTM D1557

1804.6 Exception

Before portions of a structure can be occupied, the required fire protection systems within that portion must be tested and approved in the presence of whom, if required?

The building official

901.5

If buildings contain materials representing hazards classified in one or more of Groups H-1, H-2, H-3, and H-4, the buildings and structures must conform to the code requirements for:

Each of the occupancies so classified

307.8

The fire-resistance rating of supporting structural members and assemblies shall be not less than the rating required for the fire-resistance-rated assemblies supported, EXCEPT for supports of fire partitions as provided in which section?

Section 708.4

704.1.1

In Group I-2 occupancies, stories shall be divided into smoke compartments with an area of not more than:

22,500 square feet (2092 m2)

407.5.1

Building-integrated photovoltaic (BIPV) systems used as exterior wall coverings or fenestration must be listed and labeled in accordance with UL 1703 or both:

UL 61730-1 and UL 61730-2

1411.1

Glazed areas in hazardous locations must comply with impact requirements, with the exception of mirrors and other glass panels mounted or hung on a surface that provides a:

continuous backing support.

2406.1

Grab bars, shower seats, and accessible benches shall be designed to resist a single concentrated load of:

250 pounds (1.11 kN)

1607.9.2

The response modification coefficient, R, designated for “Steel systems not specifically detailed for seismic resistance, excluding cantilever column systems” in ASCE 7, Table 12.2-1, shall be permitted for structural steel systems designed and detailed in accordance with which standard?

AISC 360

2202.2.1.1 Exception

Wire backing is not required under which two types of lath?

Expanded metal lath or paperbacked wire fabric lath

2510.5.3

The required fire-resistance rating of exterior walls with a fire separation distance of less than or equal to 10 feet (3048 mm) shall be rated for exposure to fire from:

Both sides

705.5

Which of the following information is NOT required to be sealed and signed by the joist manufacturer’s registered design professional?

Steel joist placement plans

2207.4, 2207.4.1

The chimney wall or chimney flue lining shall not change in size or shape within what maximum distance above or below where the chimney passes through floor, ceiling, or roof components?

6 inches (152 mm)

2113.6

Metal flashing to which bituminous materials are to be adhered during reconstruction must be treated how prior to installation?

primed

1512.5

For a sprinklered space in Group R-2 occupancy, what is the maximum occupant load allowed for a single exit or exit access doorway?

20

Table 1006.2.1

Conveyors and related equipment connecting successive floors or levels must be enclosed with which type of construction?

Shaft enclosures complying with Section 713

3004.3.1

In required exits or corridors, the area of approved light-transmitting plastic materials used in electrical luminaires shall not exceed what maximum percentage of the aggregate area of the ceiling?

30 percent

2606.7.5

For a frame inspection to be made, the rough electrical, plumbing, heating wires, pipes, and ducts must be:

Approved

110.3.4

For structural steel frame structures designed using Allowable Stress Design (ASD), end connections of all beams and girders must have a minimum nominal axial tensile strength equal to the required vertical shear strength but not less than:

10 kips (45 kN)

1616.2.2.2

An Accreditation Body is an approved, third-party organization that monitors the competency and performance of a grading or inspection agency and is independent of:

Grading and inspection agencies, and the lumber mills

202 [BS] Accreditation Body

Hydrogen fuel gas rooms not classified as Group H shall be provided with a ventilation system designed to maintain the room at a negative pressure in relation to:

Surrounding rooms and spaces

421.3.1

Where fire doors are required to be automatic-closing due to smoke detection, the door shall not have more than what maximum delay before the door starts to close after the smoke detector is actuated?

10-second delay

716.2.6.6

The thickness of thin exterior structural glass veneer must be not less than:

0.344 inch (8.7 mm)

1404.13.2

Where weather protection is provided for outdoor hazardous material storage or use areas, walls shall not obstruct more than what portion of the structure’s perimeter?

25 percent

414.6.1.1 Exception

An anchor building adjoining the perimeter line of an open mall building shall be separated on all sides by a permanent open space of not less than:

60 feet (18 288 mm)

402.2

When the building official issues a permit, how shall the construction documents be formally designated?

"Reviewed for Code Compliance"

107.3.1

According to Table 903.2.5.2, what is the required Occupancy Hazard Classification for Fabrication areas in a Group H-5 occupancy?

Ordinary Hazard Group 2

Table 903.2.5.2

Factory industrial uses involving the fabrication of noncombustible materials, such as brick and masonry or glass products, that do not involve a significant fire hazard are classified as which group?

Group F-2 Low Hazard

306.3

The means of egress shall have a ceiling height of not less than what distance above the finished floor?

7 feet 6 inches (2286 mm)

1003.2

For awnings and canopies, if the covering material is tested in accordance with NFPA 286, what is the maximum permissible peak heat release rate throughout the test?

Not exceed 800 kW.

3105.3

Not more than what maximum percentage of the thickness measurements of the SFRM shall be less than the thickness required by the approved fire-resistance design?

10 percent.

1705.15.4

Vinyl siding must be certified and labeled as conforming to the requirements of:

ASTM D3679

1403.8

Door handles, pulls, latches, locks and other operating devices shall be installed 34 inches (864 mm) minimum and what maximum distance above the finished floor?

48 inches (1219 mm)

1010.2.3

For exposed aggregate plaster, the aggregate used shall consist of marble chips, pebbles, or similar durable, moderately hard, nonreactive materials with a minimum Mohs hardness scale rating of:

3 or more

2513.2

Where the path of egress travel is not at the level of exit discharge from an atrium, that portion of the total permitted exit access travel distance that occurs within the atrium shall be not greater than:

200 feet (60 960 mm)

1017.3.2.3

Towers, spires, domes and cupolas greater than 85 feet in height above grade plane must be constructed of and supported on Type I or II construction if they are either greater than 200 square feet in horizontal area or used for any purpose other than a belfry or an:

architectural embellishment

1511.5

The required fire-resistance rating for a fire barrier separating dressing rooms from a stage with a height greater than 50 feet (15 240 mm) is not less than:

2 hours

410.4.1

According to Table 1504.8, for an aggregate-surfaced roof using ASTM D1863 (No. 7 or No. 67) aggregate, a mean roof height of 100 ft, and a basic wind speed (V) of 150 mph in Exposure B, what is the minimum required parapet height (in inches)?

46

1504.8

In aircraft manufacturing facilities of Type I or II construction, for a height of 100 feet (30 480 mm) or more and a manufacturing area of 1,000,000 square feet (92 900 m2) or more, what is the maximum exit access travel distance permitted?

1,500 feet

Table 412.6

For concrete foundation walls designed using Table 1807.1.6.2 in Seismic Design Categories A and B, not less than one No. 5 bar must be provided around window, door and similar sized openings, and the bar shall be anchored to develop fy in tension at the:

corners of openings

1807.1.6.2.1

What action is the building official authorized to take upon the third offense of failing to properly conduct, document, and maintain documentation required by Section 3302.3?

Issue a stop work order

3302.3.1

The triangular openings at the open sides of a stair shall not allow passage of a sphere of what maximum diameter?

6 inches (152 mm)

1015.4 Exception 2

Where dining surfaces are provided, at least what percentage, but not less than one, of the dining surfaces for seating and standing spaces shall be accessible?

5 percent

1109.2.9.1

In unvented attics in Climate Zones 5, 6, 7, and 8, any air-impermeable insulation shall be a Class II vapor retarder or shall have a Class II vapor retarder coating in direct contact with the:

underside of the insulation

1202.3 Item 4

What material must fully encase the backs of wall-mounted signs and non-illuminated portions of all interior signs regulated by Section 2611?

Metal

2611.4

A free-standing building assigned to Risk Category I is excepted from frost protection requirements if the area is 600 square feet or less for light-frame construction OR what maximum area for other than light-frame construction?

400 square feet (37 m2)

1809.5 Exception

According to Table 2304.8(3), for wood structural panel sheathing rated 24/16 and 7/16-inch thick, what is the maximum span permitted (in inches) when edge support is provided?

24

2304.8(3)

When tested in accordance with NFPA 286, the peak heat release rate of an interior finish shall not exceed:

800 kW

803.1.1.1

According to Table 2406.2(1), what is the minimum CPSC Category class required for glazing in doors if the exposed surface area is more than 9 square feet?

II

2406.2

Premixed prepared Portland cement mortars used in ceramic tile installation, requiring only the addition of water, must comply with which ANSI standard?

ANSI A118.1

2103.2.3.1

Chemical-resistant furan mortar and grout used for ceramic tile installation must comply with which ANSI standard?

ANSI A118.5

2103.2.3.4

Openings in a fire barrier shall be limited to a maximum aggregate width of 25 percent of the length of the wall, and the maximum area of any single opening shall not exceed 156 square feet, EXCEPT where the opening protective has been tested to ASTM E119 or UL 263 and has a minimum fire-resistance rating of:

Not less than the required fire-resistance rating of the wall

707.6 Exception 3

A Story Above Grade Plane must have the finished surface of the floor next above more than 6 feet (1829 mm) above grade plane or more than 12 feet (3658 mm) above the:

Finished ground level at any point

202 [BG] Story Above Grade Plane

The emergency control station required in Group H-5 occupancies shall be continuously staffed by:

Trained personnel

415.11.10.2

For water closets designed for assisted toileting, the clearance around the water closet shall be not less than what minimum width?

66 inches (1675 mm)

1110.2.2.2.1

A building, room or space used for assembly purposes with fixed seating with a seating capacity of 501 to 5,000 requires 6 wheelchair spaces, plus one for each how many seats, or fraction thereof, between 501 through 5,000?

150

Table 1109.2.2.1

According to Table 1705.3, what inspection is required prior to concrete placement?

Fabricate specimens for strength tests, perform slump and air content tests, and determine the temperature of the concrete.

Table 1705.3 Item 6

In the test procedure for modulus of rupture of adobe units, a vertical load must be applied to the cylinder at the rate of 500 pounds per minute (37 N/s) until:

failure occurs

2109.2.1.2.3

Three or more deep foundation elements connected by a rigid cap shall be considered to be braced, provided that the elements are located in radial directions from the centroid of the group not less than:

60 degrees (1 rad) apart

1810.2.2

What is the maximum time period, in days, that occupancy of a dwelling unit or sleeping unit is classified as Transient?

30 days

202 [BG] Transient

When calculating the Gross Cross-Sectional Area for masonry, the area is delineated by the:

Out-to-out specified dimensions

202 [BS] Gross Cross-Sectional

A permit for temporary structures, equipment, or systems shall be limited as to time of service, but shall not be permitted for more than:

180 days

108.1

Plaster containing Portland cement is prohibited as a finish over what type of plaster?

clay plaster

2109.2.4.8.9.4

Single- and multiple-component spray-applied foam plastic insulation must comply with the provisions of Section 2603 and which standard?

ICC 1100

2603.1.1

Where an egress court serving a building is less than 10 feet (3048 mm) in width, the egress court walls shall have not less than 1-hour fire-resistance-rated construction for a distance of how many feet above the floor of the egress court?

10 feet (3048 mm)

1029.3

When designing sloped glazing using Equation 24-4, the allowable resistance (Fga) must be based on the:

long duration load resistance.

2404.2

Live loads that exceed 100 psf shall not be reduced, except for members supporting two or more floors, where the reduction shall not be greater than:

20 percent

1607.13.1.2

What minimum fire protection rating is required for each door in the smoke barrier separating the fire service access elevator lobby from the floor (excluding doors to control rooms)?

3/4-hour

3007.6.3

For Group I-1, Condition 2, Group I-2, or I-3 occupancies, the egress path is permitted to pass through not more than two delayed egress locking systems, provided that the combined delay does not exceed:

30 seconds

1010.2.12.1 Item 5.1

For glass walls in racquetball or squash courts, the deflection at the point of impact shall not be greater than 1 1/2 inches (38 mm) for a drop height of:

48 inches (1219 mm).

2408.2.1

What is the required separation in hours between a sprinklered (S) Group F-2, S-2, or U occupancy and a sprinklered (S) Group H-2 occupancy?

3

Table 508.4

According to Table 1807.1.6.3(1) for plain masonry foundation walls, what is the minimum nominal wall thickness required for an 8-foot maximum wall height, 6-foot maximum unbalanced backfill height, and a design lateral soil load of 45 psf/ft?

12 inches

1807.1.6.3

In Group I-2 occupancies, failure of a single lamp in a luminaire shall not reduce the illumination level under emergency power to less than:

0.5 footcandle (5.4 lux)

1008.3.2

In buildings requiring an automatic sprinkler system, when is it unlawful to occupy any portion of the building?

Until the automatic sprinkler system installation has been tested and approved

3312.1

A building, room or space used for assembly purposes with fixed seating with a seating capacity of 51 to 100 requires what minimum number of wheelchair spaces?

4

Table 1109.2.2.1

For patterned glass, the nonfactored load (Fge) used in design shall be based on what characteristic of the glass?

The thinnest part of the glass.

2404.3.3

The aggregate area of all equipment platforms within a room shall be not greater than what fraction of the area of the room in which they are located?

Two-thirds

505.3.1

Glass unit masonry construction must comply with Chapter 14 of TMS 402 and:

this section (2110)

2110.1

Where photoluminescent exit path markings are installed, they shall be provided with not less than 1 footcandle (11 lux) of illumination for not less than what minimum duration prior to periods when the building is occupied?

60 minutes

1025.5

What type of standpipes (temporary or permanent, with or without water supply) are permitted during construction, provided they conform to Section 905 regarding capacity, outlets, and materials?

Temporary or permanent, and with or without a water supply

3311.3 Exception

If a fire wall separates Group F-2, S-2, R-3, or R-4 occupancies, what is the minimum required fire-resistance rating in hours?

2 hours

Table 706.4

For breakaway walls in coastal high hazard areas designed for ultimate load, documentation is required if the resistance is more than what maximum value?

33 pounds per square foot (1.58 kN/m2)

1612.4

In areas not subjected to freezing, footings for masonry fireplaces must be not less than what minimum distance below finished grade?

12 inches (305 mm)

2111.3

Play structures must comply with Section 424 if they exceed 10 feet (3048 mm) in height or what area?

150 square feet (14 m2)

424.1

Exterior metal veneer shall be securely attached to the supporting masonry or framing members, with the spacing of the fastenings or ties not exceeding 24 inches either vertically or horizontally, but where units exceed 4 square feet in area there shall be not less than:

four attachments per unit

1404.12.1

In Group R-2 college dormitories, which domestic cooking appliance shall NOT be installed or used in sleeping rooms?

Ovens

420.11.2

Where compartmentation is required in an underground building, each compartment shall have not fewer than one exit and not fewer than one exit access doorway into the:

Adjoining compartment

405.7.1

When tested in accordance with ASTM E331 to demonstrate resistance to wind-driven rain, exterior wall test assemblies must be subjected to a minimum test exposure duration of:

2 hours

1402.2

Special inspection of cold-formed steel trusses over what minimum length must be in accordance with Section 1705.2?

60 feet (18 288 mm)

2206.1.3.2

Each revolving door used as a component of a means of egress shall be credited with a capacity based on not more than a maximum occupant load of:

50 person occupant load

1010.3.1.1

Accessible units are permitted to be designed and constructed as:

None of the above

1108.2

The suitability of clay subsoil for use in clay plaster must be determined in accordance with the Figure 2 Ribbon Test and the Figure 3 Ball Test in the appendix of which ASTM standard?

ASTM E2392/E2392M

2109.2.4.8.9.2

Where food service lines are provided, and self-service shelves are present, at least what percentage, but not less than one, of each type of self-service shelf provided shall be accessible?

50 percent

1110.16.3

Where an exterior wall intersects a fire wall, the fire-resistance rating of the exterior wall shall extend not less than what distance on each side of the intersection?

4 feet (1220 mm)

706.5.1

Buildings containing materials that pose a detonation hazard, such as Class 4 oxidizers or Division 1.1 explosives, shall be classified as which High-Hazard Group?

Group H-1

307.3

How must areaways below grade be protected?

By grates, guards or other approved means.

3202.1.3

Pedestrian walkways separated from the interior of the building by fire barriers must have those fire barriers constructed with what minimum fire-resistance rating?

Not less than 2-hour.

3104.5.1

Ventilation (other than the percentage of openings required in Section 406.5.2) shall be required for an open parking garage:

Not required

406.5.10

Flashing, where made of metal, must be corrosion resistant with a thickness of not less than:

0.019 inch (0.483 mm) (No. 26 galvanized sheet)

1503.2.1

The allowable compressive load on any driven deep foundation element determined by an approved driving formula shall not exceed:

40 tons (356 kN)

1810.3.3.1.1

Plumbing systems shall not be located in which elevator areas?

Elevator equipment rooms

3005.6

Where access is by means of a private road and the building address cannot be viewed from the public way, what means shall be used to identify the structure?

A monument, pole or other approved sign

502.1

Access to exits is permitted by way of a dead-end mall that does not exceed a length equal to:

Twice the width of the mall

402.8.6 Exception

Vehicle ramps used for vertical circulation as well as parking shall not exceed a slope of:

1 unit vertical in 15 units horizontal

406.4.3

Doors through which occupants must pass to complete the exit path shall be identified by a low-location luminous emergency exit symbol complying with NFPA 170. The symbol shall be not less than what minimum height?

4 inches (102 mm)

1025.2.6.1

For cold-formed steel light-frame construction, the design and installation of structural framing systems must be in accordance with which standard?

AISI S240

2206.1

Insulating concrete form (ICF) material used for forming flat concrete walls must conform to which ASTM standard?

ASTM E2634

1903.3

For exterior walls of buildings of Type I, II, III or IV construction, the potential heat of foam plastic insulation in any portion of the wall must not exceed the potential heat of the foam plastic insulation contained in the wall assembly tested in accordance with which section?

Section 2603.5.5

2603.5.3

The provisions for underground buildings apply to building spaces having a floor level used for human occupancy more than what depth below the finished floor of the lowest level of exit discharge?

30 feet (9144 mm)

405.1

Where interior exit stairways or ramps are interconnected by a 1-hour fire-resistance-rated corridor, the required exit separation distance is permitted to be measured along the shortest direct line of travel within the:

corridor

1007.1.1 Exception 1

In flood hazard areas, prior to further vertical construction, the required elevation certification must be submitted to the building official upon placement of the:

Lowest floor

110.3.3

Where court-floor holding cells are provided and are not separated by age or sex, courtrooms shall be served by at least how many accessible cells?

at least one accessible cell

1109.4.2.2

Where fixed or built-in storage elements are provided in required accessible spaces, at least what percentage, but not less than one of each type, shall be accessible?

5 percent

1110.12

Where cladding is installed directly over foam sheathing to wood framing using a 0.162-inch diameter nail, with a cladding weight of 25 psf and a fastener vertical spacing of 12 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.1 (assuming 16 inches on center horizontal spacing)?

0.5

1404.5.3.1

In an accessible toilet room, where a floor level is not required to be connected by an accessible route, the only toilet rooms or bathing rooms provided within the facility shall not be located:

on the inaccessible floor

1110.2

Gift shops in Group I-2 occupancies shall be permitted to be open to the corridor if they and their associated storage are less than what maximum area?

500 square feet (455 m2)

407.2.4

Every room or space that is an assembly occupancy shall have the occupant load posted in a conspicuous place, near the main exit or exit access doorway, on a sign that must be maintained by whom?

The owner or the owner's authorized agent

1004.9

Continuously operated mechanical ventilation for crawl spaces shall be provided at a rate of 1.0 cubic foot per minute (cfm) for each how many square feet of crawl space ground surface area?

50 square feet

1202.4.3.1

Where required by Section 2304.12, plastic composite materials containing wood, cellulosic, or other biodegradable materials must be termite and decay resistant as determined in accordance with which standard?

ASTM D7032

2612.4

Periodic special inspections of sealants or adhesives shall be conducted where sealant or adhesive required by Section 703.7 is applied to:

mass timber building elements.

1705.2

An automatic sprinkler system is required throughout stories containing Group A-2 occupancies where the fire area exceeds:

5,000 square feet (464 m2)

903.2.1.2

What is the minimum clearance required to the lowest portion of the hood or awning for temporary entrance awnings?

Not less than 7 feet (2134 mm).

3202.4

For closed valleys (valleys covered with shingles) used with asphalt shingles, valley lining of one ply of smooth roll roofing complying with ASTM D6380 shall be permitted, and must be not less than what minimum width?

36 inches (914 mm)

1507.2.8.2

In Types I and II construction, sloped glazing and skylight frames must be constructed of:

noncombustible materials.

2405.4

Dwelling units shall have a minimum of how many square feet of habitable space?

190 square feet (17.7 m2)

1208.3

Connections in intermediate precast structural walls that are designed to yield must be capable of maintaining 80 percent of their design strength at the deformation induced by the design displacement or must use:

Type 2 mechanical splices

1905.3.1

At least one accessible route within the site shall be provided from site arrival points (like public transportation stops) to the accessible building entrance, EXCEPT in buildings not containing or serving:

Type B units

1104.1 Exception

Urinal partitions shall extend from the wall surface at each side of the urinal not less than 18 inches (457 mm) or to a point not less than what minimum distance beyond the outermost front lip of the urinal?

6 inches (152 mm)

1210.3.2

Doors opening onto a stairway landing shall not reduce the landing to less than what proportion of the required width?

one-half

1011.6

What is the minimum vertical clearance required from the public right-of-way to the lowest part of a pedestrian walkway?

Not less than 15 feet (4572 mm).

3202.3.4

Emergency alarm initiating devices shall be installed outside of each interior exit or exit access doorway of rooms used for the storage of:

Hazardous materials

415.5.1

Special inspections are not required for cold-formed steel light-frame shear walls where the sheathing is:

gypsum board or fiberboard.

1705.13.3 Exception 1

Is elevator hoistway door protection required at the levels of exit discharge if that level is equipped with an automatic sprinkler system?

No, if the level of exit discharge is sprinklered

3006.2 Exception 2

What are the maximum thickness and maximum width limits for foam plastic used as interior trim?

1/2 inch (12.7 mm) thick and 8 inches (204 mm) wide

2604.2.2

Joints in wood tie beams for adobe construction must be spliced not less than 6 inches (152 mm), and splices shall not be allowed within what minimum distance of an opening?

12 inches (305 mm)

2109.2.4.7.2

Lateral force-resisting systems shall meet seismic detailing requirements and limitations prescribed in this code and ASCE 7 even where what other load effects are greater than seismic load effects?

Wind load

1604.9

For plain concrete footings supporting walls that exceed 8 inches in thickness in Seismic Design Category C, D, E or F, not fewer than how many bars must be provided at the top and bottom of the footing?

one bar

1905.6.2 Item 3

The path of egress travel measured from the most remote point of each room to the point where occupants have separate and distinct access to two exits is the:

Common Path of Egress Travel

202 [BE] Common Path of Egress Travel

For address identification, each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of:

1/2 inch (12.7 mm)

502.1

Two exit access doorways are required in boiler, incinerator and furnace rooms where the area is over 500 square feet (46 m2) and any fuel-fired equipment exceeds what input capacity?

400,000 Btu (422 000 KJ)

1006.2.2.1

In recreational boating facilities, where the number of boat slips provided is 75, what is the minimum required number of accessible boat slips?

3

Table 1111.4.9.1

Ambulatory care facilities and Group I-2 occupancies must be ventilated by mechanical means in accordance with which section of the International Mechanical Code?

Section 407

1202.1

A High-Rise Building is defined as a building with an occupied floor or occupiable roof located more than 75 feet (22 860 mm) above the:

Lowest level of fire department vehicle access

202 [BG] High-Rise Building

What is the required minimum fire separation distance (FSD) for an exterior wall projection to be permitted to extend to 24 inches (610 mm) from the line used to determine the FSD?

2 to less than 3 feet

Table 705.2

For a fire service access elevator, what is the exception regarding its requirement to serve the top floor of a building?

The elevator shall not be required to serve the top floor of a building where that floor is utilized only for equipment for building systems

3007.1 Exception 2

Where installed on exterior walls having a fire separation distance of 5 feet or less, combustible exterior wall coverings tested in accordance with NFPA 268 shall not exhibit:

sustained flaming

1405.1.1.1.1

Glazed openings in doors are not considered hazardous locations if the opening size is unable to pass a sphere of what diameter?

3-inch-diameter (76 mm).

2406.4.1

The exemption for accessible routes in multilevel buildings with less than 3,000 square feet aggregate area does NOT apply to structures with how many or more dwelling units?

four or more dwelling units

1104.4 Exception 1.5

According to Table 1507.1.1(1), for Clay and concrete tiles installed outside hurricane-prone regions where the maximum basic wind speed (V) is 140 mph, which underlayment standard is NOT listed as compliant?

ASTM D6380 Class M

1507.1.1

Adobe units shall have a moisture content not exceeding what maximum percentage by weight?

4 percent

2109.2.1.3

Stumps and roots must be removed from the soil to a depth of not less than what minimum distance below the surface of the ground in the area to be occupied by the building?

12 inches (305 mm)

3304.1

On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge not less than 12 inches plus:

2 percent

1808.7.4

A vertical plastic sign affixed to a storefront facing a mall shall be not greater than 96 inches (2438 mm) in height and the width shall be not greater than:

36 inches (914 mm)

402.6.4.2

What is the maximum time allowed for a required standby power-generating system for an auxiliary inflation system to automatically start and transfer all required electrical functions at full power after normal electrical service failure?

Within 60 seconds.

3102.8.2

What must be provided before a horizontal exit can be destroyed?

A substitute means of egress has been provided and approved

3303.3

Standby power for auxiliary inflation systems in permanent membrane structures shall be provided for a duration of not less than how long?

4 hours

2702.2.15

Clay flue liners must extend from a point not less than 8 inches (203 mm) below the lowest inlet or, in the case of fireplaces, from the top of the smoke chamber to a point above the:

enclosing walls

2113.12

Greenhouses used for the display and sale of plants that provide public access are classified as which occupancy group?

Group M

309.1

An automatic sprinkler system protecting a Group H occupancy must be monitored by an approved supervising station in accordance with:

NFPA 72

901.6.1

When may the building official issue a temporary certificate of occupancy?

Provided that such portion or portions shall be occupied safely

111.3

Urinal partitions utilized by the public or employees shall begin at a height not more than 12 inches (305 mm) from the finished floor and extend not less than what minimum height above the finished floor surface?

60 inches (1524 mm)

1210.3.2

Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses and company names and logos are:

not required to comply with Section 1112.6

1112.6 Exceptions

An accessible route shall connect each accessible story, mezzanine, and occupiable roofs in multilevel buildings and facilities, EXCEPT where these areas have an aggregate area of not more than:

3,000 square feet (278.7 m2)

1104.4 Exception 1

Each pane of glass must bear the manufacturer’s mark designating the type and thickness, unless an affidavit is furnished by the glazing contractor certifying that each light is glazed in accordance with:

approved construction documents.

2403.1

For roofing assemblies, a thermal barrier is not required if the roof assembly with foam plastic insulation passes which standard test?

NFPA 276 or UL 1256

2603.4.1.5

Theaters intended for the production and viewing of the performing arts or motion pictures, usually with fixed seating, are classified as which Assembly Group?

Group A-1

303.2

Portable fire extinguishers must be provided at each stairway on all floor levels where what materials have accumulated?

Combustible materials

3309.1

The 1/4-inch (6.4 mm) ties or equivalent reinforcement for vertical bars in masonry fireplaces must be spaced not to exceed what maximum distance on center in concrete?

18 inches (457 mm)

2111.4.2

For reinforced gypsum concrete, the minimum required thickness shall be 2 inches (51 mm), but is permitted to be reduced to 1 1/2 inches (38 mm), provided the clear span between supports does not exceed 33 inches, diaphragm action is not required, and the design live load does not exceed:

40 psf (1915 Pa)

2514.2

Light-transmitting plastics classified as Class CC1 must have a burning extent of what maximum distance when tested in accordance with ASTM D635?

1 inch (25 mm) or less

2606.4

What is the Tabular allowable area factor in square feet for a building classified as Group E, one story above grade plane (S1) of Type VA construction?

74,000

Table 506.2

According to Table 2609.4, what is the maximum aggregate area of roof panels permitted as a percentage of the floor area when using Class CC1 plastic?

30 percent

Table 2609.4

Curtains, draperies, fabric hangings and similar combustible decorative materials suspended from walls or ceilings in Group A, B, E, I, M, R-1 and R-2 dormitories shall not exceed what maximum percentage of the specific wall or ceiling area?

10 percent

806.2

Rubble stone shall not be used for foundation walls of structures assigned to which Seismic Design Category or greater?

Seismic Design Category C

1807.1.3

Building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening in an interior exit stairway or ramp shall have a fire-resistance rating of not less than:

1 hour

1023.7.1

For conventional light-frame construction in Seismic Design Category C, the structure is limited to what maximum height?

Two stories

2308.2.1

What is the required separation and protection for waste and linen collection rooms in Group I-2 occupancies where containers have an aggregate volume of 8.67 cubic feet or greater?

1 hour and provide automatic sprinkler system

Table 509.1

For a 40-foot container with a nominal height of 9.5 feet (Container Designation 1AAA), what is the Allowable Shear Value (PLF) for the side wall for wind or seismic loading, based on Table 3114.8.5.3?

84 PLF.

Table 3114.8.5.3

An uninterrupted source of power must be provided for equipment when required by the manufacturer’s instructions, the listing, this code, or which other applicable items?

applicable referenced standards

2702.1.6

Light-transmitting plastic roof panels shall not be installed in which occupancy groups?

Groups H, I-2 and I-3

2609.1

Emergency or standby power is required for gas detection systems in accordance with which code?

International Fire Code

2702.2.7

For buildings of construction types other than Type VB, the aggregate area of light-transmitting plastic glazing shall not exceed what maximum percentage of the area of any wall face of the story in which it is installed?

25 percent

2608.2

The foundation or superstructure shall be designed to resist the effects of the mislocation of any deep foundation element by not less than:

3 inches (76 mm)

1810.3.1.3

Foam plastic spray applied to a sill plate, joist header, and rim joist in Type V construction is permitted without a thermal barrier provided the maximum thickness does not exceed:

3 1/4 inches (82.6 mm)

2603.4.1.13

In commercial or industrial buildings, the design live loads must be conspicuously posted using durable signs for each floor or portion thereof designed for live loads exceeding:

50 psf (2.40 kN/m2)

106.1

In Type IV-A construction, the floor assembly must contain a noncombustible material above the mass timber not less than what thickness?

1 inch (25 mm)

602.4.1.3

Penthouses shall not be used for purposes other than the shelter of mechanical or electrical equipment, tanks, elevators and related machinery, stairways or:

vertical shaft openings in the roof assembly

1511.2.2

A Computer Room is a room used primarily to house information technology equipment (ITE) and serving an ITE load less than or equal to 10 kW or what conditioned floor area load?

20 W/ft2 (215 W/m2)

202 [BG] Computer Room

The aggregate area of openings for projection equipment shall not exceed what percentage of the area of the wall between the projection room and the auditorium?

25 percent

409.2

Fire partitions used for dwelling unit and sleeping unit separations in buildings of Types IIB, IIIB, and VB construction shall have a minimum fire-resistance rating of 1/2 hour, provided the building is equipped throughout with an:

Automatic sprinkler system

708.3 Exception 2

Rooftop-mounted photovoltaic (PV) panel systems and solar thermal collectors must be designed in accordance with which section regarding wind resistance?

Section 1609.

3111.1.1

Light-transmitting plastics classified as Class CC2 must have a burning rate of what maximum speed when tested in accordance with ASTM D635?

2 1/2 inches per minute (1.06 mm/s)

2606.4

In structures assigned to Seismic Design Category C or D, masonry fireplaces must be reinforced and anchored in accordance with Sections 2111.4.1, 2111.4.2, and:

2111.8

2111.4

Where an automatic sprinkler system is provided, vertical openings for escalators protected by automatic shutters must have a fire-resistance rating of not less than:

1.5 hours

712.1.3.2

Supporting data necessary to assist in the approval of products, materials or assemblies not specifically provided for in this code must consist of valid research reports from:

approved sources.

1703.4.2

In all occupancies, interior floor covering materials must comply with the requirements of the DOC FF-1 “pill test” (CPSC 16 CFR Part 1630) or with:

ASTM D2859

804.4.1

According to Table 1507.2.8.2, what is the minimum required weight for Cold-rolled copper valley lining material?

16 oz. per square ft.

1507.2.8.2

Exterior walls required to be of heavy timber construction are permitted to be cross-laminated timber not less than what minimum thickness?

4 inches (102 mm)

2304.11.2.1

Miniature golf courses shall be configured so that the accessible holes are consecutive, EXCEPT that one break in the sequence of consecutive holes shall be permitted provided that:

the last hole on the miniature golf course is the last hole in the sequence

1111.4.12.2 Exception

Handrails with a circular cross section shall have an outside diameter of not less than 1 1/4 inches (32 mm) and not greater than:

2 1/4 inches (57 mm)

1014.4.1

Where a response modification coefficient, R, in accordance with ASCE 7, Table 12.2-1, is used for the design of cold-formed steel special bolted moment frames, the structures must be designed and detailed in accordance with the requirements of which standard?

AISI S400

2204.2.1

In Seismic Design Categories D and E, openings in floor diaphragms shall not have any dimension exceeding what maximum percentage of the distance between braced wall lines?

50 percent

2308.8.4.1

Special inspections of compacted fill must be in accordance with which specific section?

Section 1705.6

3304.1.4

Special inspections of structural steel in the seismic force-resisting systems in structures assigned to Seismic Design Category B, C, D, E or F must be performed in accordance with the quality assurance requirements of:

AISC 341.

1705.13.1.1

Clear space between a handrail and a wall or other surface shall be not less than:

1 1/2 inches (38 mm)

1014.8

If an alternative material, design, or method of construction is not approved by the building official, how must the building official respond?

In writing, stating the reasons the alternative was not approved

104.2.3.2

The required development length of reinforcement need not be greater than what maximum multiple of the bar diameter?

72

2108.2

Decreases in wind loads shall not be made for the effect of:

shielding by other structures

1609.1

Asphalt shingles shall only be used on roof slopes of what minimum units vertical in 12 units horizontal?

2 units

1507.2.2

Each required area of refuge shall be sized to accommodate one wheelchair space (30 inches by 52 inches) for each how many occupants or portion thereof, based on the occupant load?

200 occupants

1009.6.3

Where a building contains more than one occupancy group, it shall comply with the applicable provisions of Section 508.2, 508.3, 508.4, 508.5, or a combination of these sections, but NOT with:

Occupancies separated in accordance with Section 510

508.1 Exception 1

The minimum size for stairway identification signs required at floor landings in interior exit stairways and ramps connecting more than three stories shall be:

18 inches (457 mm) by 12 inches (305 mm)

1023.9.1

For a chemical to be classified as Highly Toxic via oral administration, it must have a median lethal dose (LD50) of how many milligrams or less per kilogram of body weight to albino rats?

50 milligrams

202 [F] Highly Toxic

The analysis of deep foundation elements must include group effects on axial behavior where the center-to-center spacing of elements is less than what maximum factor multiplied by the least horizontal dimension of an element?

three times

1810.2.5

Which class of combustible liquid has a closed cup flash point at or above 140°F (60°C) and below 200°F (93°C)?

Class IIIA

202 [F] Class IIIA

Stairways shall have intermediate handrails located such that all portions of the stairway minimum width or required capacity are within what distance of a handrail?

30 inches (762 mm)

1014.1

For retaining walls, the design shall be based on 0.7 times nominal earthquake loads, 1.0 times other nominal loads, and investigation with one or more of the variable loads set to zero, to ensure a minimum safety factor of:

1.5

1807.2.3

Which standard governs the design, construction, installation, alteration, repair, and maintenance of elevators, escalators, dumbwaiters, moving walks, and material lifts?

ASME A17.1/CSA B44, ASME A17.7/CSA B44.7

Table 3001.3

What is the minimum clear width required for escalators provided in below-grade transportation stations?

32 inches (815 mm)

3004.2.2

A cricket or saddle shall be installed on the ridge side of any chimney or penetration greater than what maximum width as measured perpendicular to the slope?

30 inches (762 mm)

1503.5

For a furnace room incidental use, where the largest piece of equipment is over 400,000 Btu per hour input, what is the required separation and/or protection?

1 hour or provide automatic sprinkler system

Table 509.1

The maximum allowable area of protected (P) openings in an exterior wall where the fire separation distance is 15 to less than 20 feet is:

75%

Table 705.9

What is the maximum horizontal area permitted between draftstops in combustible attic spaces in occupancies other than Group R?

3,000 square feet (279 m2)

718.4

From a height of 36 inches (914 mm) to 42 inches (1067 mm), guards shall not have openings that allow passage of a sphere of what maximum diameter?

4 3/8 inches (111 mm)

1015.4 Exception 1

Water-resistant organic adhesives used for ceramic tile installation must comply with ANSI A136.1, and the shear bond strength after water immersion must be not less than 40 psi (275 kPa) for what adhesive type?

Type I adhesive

2103.2.3.6

In heavy timber construction (Type IV-HT), minimum dimensions of columns shall be in accordance with Table 2304.11, and columns must be continuous or aligned vertically from floor to floor in all stories of which type of construction?

Type IV-HT

2304.11.1.1

What is the maximum nominal diameter permitted for penetrating steel, ferrous, or copper pipes where concrete, grout, or mortar is used to protect the annular space in a concrete or masonry wall without requiring a through-penetration firestop system?

6 inches (152 mm)

714.4.1 Exception

Sprinkler protection is NOT required at the ceiling of an atrium where the ceiling of the atrium is more than what height above the floor?

55 feet (16 764 mm)

404.3 Exception

At least what percentage, but not less than one, of care recipient and visitor parking spaces provided to serve hospital outpatient facilities shall be accessible?

10 percent

1106.4

Sanitary facilities must be provided during construction, remodeling or demolition activities in accordance with which code?

The International Plumbing Code

3305.1

The presumptive vertical foundation pressure for Clay, sandy clay, silty clay, clayey silt, silt and sandy silt (CL, ML, MH and CH) shall not exceed:

1,500 psf

1806.2

Where accessible parking is provided, how many accessible spaces are required for a parking facility providing 101 total parking spaces?

5

Table 1106.2

For covered walkways serving new light-frame construction not exceeding two stories above grade plane (Exception to 3306.7), what is the maximum spacing permitted for posts that are not less than 4 inches by 6 inches?

12 feet (3658 mm) on center

3306.7 Exception

In Types III and V construction, what material is permitted for use as hangers and assembly members of dropped ceilings that are below a horizontal fire-resistance-rated floor or roof assembly?

Noncombustible steel

803.15.2.1 Exception

For metal roof shingles valley flashing, the splash diverter rib at the flow line formed as part of the flashing shall be not less than what minimum height?

3/4 inch (19.1 mm)

1507.5.7

What is the term for a wall or surface to which the veneer is secured?

Backing

202 [BF] Backing

At least what percentage, but not less than one, of the total number of aisle seats provided shall be designated aisle seats located closest to accessible routes?

5 percent

1109.2.5

According to Table 1705.3, what type of inspection is required for adhesive anchors installed in horizontally or upwardly inclined orientations to resist sustained tension loads?

Continuous special inspection.

Table 1705.3 Item 4.a

Canopies under which fuels are dispensed at motor fuel-dispensing facilities shall have a clear, unobstructed height of not less than:

13 feet 6 inches (4115 mm)

406.7.2

Fire-retardant-treated wood tested in accordance with ASTM E84 or UL 723 must have a listed flame spread index of 25 or less, and the flame front shall not progress more than what maximum distance beyond the centerline of the burners during the additional 20-minute test period?

10.5 feet (3200 mm)

2303.2

For siding backer board, foam plastic insulation is permitted without a thermal barrier if its heat potential does not exceed 2,000 Btu/sq. ft. (22.7 mJ/m2), the maximum thickness is 1/2 inch, and it is separated from the interior by not less than:

2 inches (51 mm) of mineral fiber insulation or equivalent

2603.4.1.10

A permit is required for temporary structures that cover an area greater than 120 square feet (11.16 m2) and are intended for the gathering together of how many or more persons?

10 or more persons.

3103.1.3

Where boarding piers are provided at boat launch ramps, at least what percentage, but not less than one, of the boarding piers shall be accessible?

5 percent

1111.4.9.3

For Hospital (Visitor facilities), what is the required ratio for water closets per care recipient sleeping units or treatment room?

1 per 75

Table 2902.1

Where interior exit stairways are required to be separated in a high-rise building, the separation distance shall be not less than 30 feet (9144 mm) or not less than what fraction of the length of the maximum overall diagonal dimension of the building or area served, whichever is less?

One-fourth

403.5.1

Horizontal exits are permitted to comprise two-thirds of the required exits from any building or floor area for which specific occupancy group?

Group I-2

1026.1 Exception 1

Raised areas used primarily for purposes of security, life safety, or fire safety are generally exempt from Chapter 11 requirements, including, but not limited to:

observation galleries

1103.2.6

Interior wall and ceiling finish materials having a thickness less than 0.036 inch (0.9 mm) applied directly to the surface of walls or ceilings are exempt from what requirement?

Being required to be tested

803.2

Required preconstruction load tests must be conducted or witnessed by an:

approved agency.

1709.7

In Group I-2 occupancies located in flood hazard areas, where new essential electrical system generators are installed, they must be located and installed in accordance with which standard?

ASCE 24

2702.1.8

For structures assigned to Seismic Design Category C, D, E or F, the geotechnical investigation must include an evaluation of all of the following potential geologic and seismic hazards EXCEPT:

Design lateral soil loads

1803.5.11

In structures assigned to Seismic Design Category A or B, detached one- and two-family dwellings three stories or less in height constructed with stud-bearing walls are permitted to have plain concrete footings without:

longitudinal reinforcement

1905.6.1

The design effects of treatment and redrying on the flexure properties of fire-retardant-treated softwood plywood must be determined in accordance with which ASTM standard?

ASTM D5516

2303.2.6.1

Class C interior finish materials are permitted in places of assembly with an occupant load of:

300 persons or less

Table 803.13 Note f

Foundation walls extending not more than 8 feet below grade and laterally supported at the top by flexible diaphragms are permitted to be designed for what type of lateral soil pressure?

active pressure

1610.1 Exception

Nonstructural concrete with a freeze-thaw exposure Class F2 or F3 must have a minimum specified compressive strength, of not less than:

3,500 psi (24.1 MPa)

1904.2

The design, detailing, fabrication, and erection of structural steel elements in seismic force-resisting systems must be in accordance with AISC 341 where a response modification coefficient, R, greater than what minimum value in accordance with ASCE 7, Table 12.2-1, is used for the design of the structure assigned to Seismic Design Category B or C?

3

2202.2.2 Item 2

Built-up roofs shall have a design slope of not less than 1/4 unit vertical in 12 units horizontal for drainage, except for coal-tar built-up roofs that shall have a design slope of not less than:

1/8 unit vertical in 12 units horizontal (1-percent slope)

1507.10.1

When is the elevator emergency sign (instructing occupants to use the exit stairways) not required?

For elevators used for occupant self-evacuation in accordance with Section 3008

3002.3 Exception

Where a Type III, IV or V building has a fire separation distance of 30 feet up to 60 feet from property lot lines, what is the required minimum water supply for vertical construction?

A minimum of 500 gpm, or 50 percent of the fire flow required for the building when constructed, whichever is greater

3313.3.2

Who must design excavation retention systems used to support an excavation for protection of adjacent property?

A registered design professional

3307.2.1

For projecting windows, balconies, architectural features or mechanical equipment located more than 8 feet (2438 mm) above grade, how is encroachment calculated?

1 inch (25 mm) of encroachment is permitted for each additional 1 inch (25 mm) of clearance above 8 feet (2438 mm).

3202.3.2

For footings cast monolithically with a slab-on-ground in Seismic Design Category C, D, E or F, how many No. 4 bars must be provided in the middle third of the footing depth, as an alternative to one bar at the top and bottom?

Two

1905.6.2 Item 3 Exception 3

For water closets designed for assisted toileting, the clearance around the water closet shall be not less than 78 inches (1980 mm) in depth, measured perpendicularly from:

the rear wall

1110.2.2.2.2

Cooling towers located on the roof deck of a building must be constructed of noncombustible materials if they are greater than 250 square feet in base area or greater than what maximum height above the roof deck, provided the roof is greater than 50 feet in height above grade plane?

15 feet (4572 mm)

1511.4

In general occupancies, public drinking fountains shall be located within a distance of travel of 500 feet (152 m) of the most remote location in the tenant space and not more than how many stories above or below the tenant space?

One story

2902.5

Where multiple single-user toilet rooms or bathing rooms are clustered at a single location, at least what percentage, but not less than one room for each use at each cluster, shall be accessible?

50 percent

1110.2 Exception 3

Type III construction is defined as having exterior walls of noncombustible materials and interior building elements made of:

Any material permitted by this code

602.3

Exterior walls separating an exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from which side?

the inside

1009.7.2

According to Table 722.2.2.1, what is the minimum required slab thickness in inches for a 3-hour fire-resistance rating when using lightweight concrete?

4.4

Table 722.2.2.1

Which type of glass, if used in louvered windows or jalousies, shall not have wire exposed on longitudinal edges?

Wired glass.

2403.5

Where open parking garages are constructed to heights less than the table maximum, allowable tier areas may be increased, provided not fewer than how many sides of each such larger tier have continuous horizontal openings?

Three sides

406.5.5

What is the minimum required horizontal separation between a play structure and building walls, partitions, or elements of the means of egress?

5 feet (1524 mm)

424.4

For a Solid Masonry Unit, the net cross-sectional area in every plane parallel to the load-bearing surface must be what percentage or more of its gross cross-sectional area?

75 percent

202 [BS] Solid

For structures assigned to Seismic Design Category D, E or F, the construction documents must include a statement if which element is designed as a structural diaphragm?

Foundation wall

1901.5

A free-standing object mounted on a post or pylon shall not overhang that post or pylon more than 4 inches (102 mm) where the lowest point of the leading edge is more than 27 inches (686 mm) and less than what distance above the finished floor?

80 inches (2032 mm)

1003.3.2

Exit and exit access doorways serving refrigeration machinery rooms shall swing in the direction of egress travel and shall be equipped with panic hardware, regardless of the occupant load served, and shall be tight fitting and:

self-closing

1006.2.2.2

Spaces under grandstands or bleachers used for accessory use areas (other than ticket booths or toilet rooms) are limited to 1,000 square feet (92.9 m2) or less in area and must be equipped with an automatic sprinkler system in accordance with:

Section 903.3.1.1

1030.1.1.1 Exception 3

Backfill placed outside the foundation must be free of organic material, construction debris, cobbles and boulders, or must be a:

controlled low-strength material (CLSM)

1804.3

Where accessible parking is provided, how many accessible spaces are required for a parking facility providing 350 total parking spaces?

8

Table 1106.2

According to Table 1806.2, what is the presumptive coefficient of friction for Sand, silty sand, clayey sand, silty gravel and clayey gravel (SW, SP, SM, SC, GM and GC)?

0.25

1806.2

A day care facility occupied by more than five children older than 2½ years of age, receiving educational or personal care services for fewer than 24 hours per day, is classified as which group?

Group E

305.2

Unstabilized adobe units must have an average compressive strength of what minimum value when tested in accordance with ASTM C67?

300 psi (2068 kPa)

2109.2.1.1

Footings for masonry fireplaces and their chimneys must extend not less than what minimum distance beyond the face of the fireplace or foundation wall on all sides?

6 inches (153 mm)

2111.3

A building that has not been previously occupied or used for its intended purpose must comply with the provisions of this code or the:

International Residential Code

102.6.1

In determining the fire-resistance rating of exterior bearing walls, compliance with the ASTM E119 criteria for unexposed surface temperature rise and ignition of cotton waste is required only for a period corresponding to the required rating of an:

Exterior nonbearing wall with the same fire separation distance

703.2.1.5

According to Table 716.1(1), the marking “W” on fire-rated glazing indicates that the assembly meets which criterion?

Meets wall assembly criteria

Table 716.1(1)

Plaster and finish assemblies applied to adobe walls must have a vapor permeance of not less than:

5 perms

2109.2.4.8.2

Courts more than two stories in height shall be provided with a horizontal air intake at the bottom not less than how many square feet (m2) in area?

10 square feet (0.93 m2)

1205.3.2

Unless otherwise specified by the approved manufacturer’s instructions, fasteners for vertical vinyl siding shall be spaced not greater than:

12 inches (305 mm)

1404.15.1.3

In separated occupancies, the required separation between Group A, E (sprinklered) and Group H-2 (sprinklered) is:

3 hours

Table 508.4

Means of egress for the upper occupancy (above an open parking garage) shall be separated from the parking occupancy by fire barriers having not less than a:

2-hour fire-resistance rating

510.7.1

Division 1.4 explosive materials, where allowed by code, shall be permitted in which High-Hazard occupancy group?

Group H-3

307.3.1

According to Table 1507.4.3, what is the minimum required thickness for Hard lead metal roof covering?

2 lbs./sq. ft.

1507.4.3

Smoke damper leakage ratings shall be Class I or II, and the elevated temperature ratings shall be not less than:

250°F (121°C)

717.3.2.2

For a nonsprinklered space in Group B occupancy with an occupant load greater than 30, what is the maximum common path of egress travel distance permitted in feet?

75

Table 1006.2.1

Each portion of a building separated by one or more fire walls complying with Section 706 shall be considered to be a separate building for the purpose of determining which of the following?

Area limitations

503.1

Within each individual tenant space in a covered or open mall building, the distance of travel from any point to an exit or entrance to the mall shall be not greater than:

200 feet (60 960 mm)

402.8.5

Where a roof hatch or trap door provides access to an unoccupiable roof, the minimum area shall be not less than:

16 square feet (1.5 m2)

1011.12.2 Exception

Where nonseparated occupancies occur in a high-rise building, the most restrictive requirements of which section shall apply throughout the high-rise building?

Section 403

508.3.1.1

Continuous Insulation (CI) is insulating material that is continuous across all structural members without thermal bridges other than fasteners and:

Service openings

202 [BF] Continuous Insulation (CI)

The openable area of openings to the outdoors for natural ventilation of an occupied space shall be not less than what minimum percentage of the floor area being ventilated?

4 percent

1202.5.1

For high-load diaphragms, the special inspector must verify the nominal size of framing members at adjoining panel edges and the spacing between fasteners in each line and at:

edge margins.

1705.5.1

Habitable spaces, other than a kitchen, shall be not less than what minimum dimension in any plan dimension?

7 feet (2134 mm)

1208.1

Cast-in-place structural concrete internally reinforced with GFRP reinforcement is permitted only for structures assigned to which Seismic Design Category?

Seismic Design Category A

1901.2.1

High-rise buildings assigned to Risk Category III or IV shall comply with the requirements of Section 1616.2 if they are frame structures, or Section 1616.3 if they are:

bearing wall structures

1616.1

Fasteners for lath used on adobe masonry walls must be corrosion resistant and spaced at a maximum of 16 inches (406 mm) on center with a minimum penetration into the adobe wall of:

1 1/2 inches (38 mm)

2109.2.4.8.5

For braced wall panels in the first story of two-story structures using a Portal Frame with Hold-Downs (PFH) (Section 2308.10.5.2), what is the minimum required panel width?

24 inches (610 mm)

2308.10.5.2

Interior stairway means of egress doors shall be openable from both sides without the use of a key or special knowledge or effort, EXCEPT that stairway discharge doors shall be openable from the egress side and shall only be locked from which side?

the opposite side

1010.2.6 Exception 1

Plaster shall not be applied directly to which type of board?

Fiber insulation board

2511.2

Coordination of terminology used in ACI 318 and ASCE 7 must be in accordance with which section?

Section 1902.1.1

1902.1

According to Table 1507.13.3, which material standard applies to Silicone protective coating used for sprayed polyurethane foam roofing?

ASTM D6694

1507.13.3

Hearth extensions must extend not less than 16 inches (406 mm) in front of, and not less than what minimum distance beyond, each side of the fireplace opening?

8 inches (203 mm)

2111.11

As a general rule, gypsum lath or gypsum wallboard shall not be used as a backing for cement plaster. What is one exception where its use is permitted with a water-resistive barrier and self-furred metal lath or self-furred wire fabric lath?

On horizontal supports of ceilings or roof soffits

2510.5.2.1

What is the minimum interior finish classification required for lobby areas in Group A-1, A-2, and A-3 occupancies?

Class B

Table 803.13 Note e

Under which six conditions is elevator hoistway door protection required in accordance with Section 3006.3?

Where the hoistway connects more than three stories and the building is not protected throughout with an automatic sprinkler system (and five other specified conditions)

3006.2

To be considered firmly supported, the deflection of the glass edge perpendicular to the pane must not exceed 1/175 of the glass edge length when the length is not more than:

13 feet 6 inches (4115 mm).

2403.3

For rain load calculations, the hydraulic head must be based on hydraulic test data or hydraulic calculations assuming a flow rate corresponding to a rainfall intensity equal to or greater than the 15-minute duration storm with return period given in which table?

Table 1611.1

1611.1

For natural lighting purposes, an opening between an interior room and an adjoining room must be unobstructed and open across not less than what fraction of the common wall area?

one-half

1204.2.1

The minimum size of combustible dust defined in the code is material that is 420 microns or less in diameter and which passes through a:

US No. 40 standard sieve

202 [F] Combustible Dust

Guards are required along open-sided walking surfaces that are located more than what distance measured vertically to the floor or grade below?

30 inches (762 mm)

1015.2

Openings between anchor buildings of Type IA construction and the mall need not be protected, except for the separation between Group R-1 sleeping units and the:

Mall

402.4.2.2.1

The registered design professional in responsible charge is responsible for reviewing and coordinating submittal documents prepared by others, including:

Phased and deferred submittal items

107.3.4

Smoke control systems shall be tested by a:

special inspector.

1705.19

According to Table 1610.1, what is the design lateral soil load for active pressure (psf per foot of depth) for Silty gravels (GM)?

40

1610.1

Where stepped aisles have seating on one side and the aisle width is 74 inches (1880 mm) or greater, how many handrails are required?

two

1030.16

According to Table 1808.8.2, what is the minimum concrete cover required for precast nonprestressed deep foundation elements exposed to seawater?

3 inches

1808.8.2

If a building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the maximum allowable quantities of certain hazardous materials (per Note d) shall be increased by what percentage?

100 percent

Table 307.1(1) Note d

The storage of gypsum board, electrical motors, and foods in noncombustible containers is classified as which Storage Group?

Group S-2 Low-Hazard Storage

311.3

Shotcrete must be in accordance with the requirements of which standard?

ACI 318

1908.1

What is the maximum allowable building height in feet for a nonsprinklered (NS) Group E occupancy of Type IIA construction?

65 feet

Table 504.3

A building intended for unlimited area use (Section 507) has 65 percent of its perimeter fronting on an open space of 55 feet or greater. What is the allowable Frontage Increase Factor?

1

Table 506.3.3.1

Until what event must the results of each daily fire safety inspection be documented and maintained on-site?

Until a certificate of occupancy has been issued

3302.3

What is the tabular allowable area factor (At) for a nonsprinklered (NS) Group A-4 occupancy of Type VA construction?

11,500 square feet

Table 506.2

The line established by law, beyond which a building shall not extend, except as specifically provided by law, is the:

Building line

202 [BG] Building Line

When indicating special requirements on construction documents for steel joists, which of the following is listed as a special load?

End moments

2207.2 Item 1.5

Doors or other devices at the point of access to an elevator car are prohibited, unless they are readily openable from inside the car without which items?

Key, tool, special knowledge, or effort

3002.6

Where Section 1803 does not require reporting of materials and procedures for fill placement, the special inspector must verify that the in-place dry density of the compacted fill is not less than what minimum percentage of the maximum dry density at optimum moisture content?

90 percent.

1705.6 Exception

The water-resistive barrier for EIFS with drainage shall comply with Section 1403.2 or:

ASTM E2570

1407.4.1.1

At each separate-sex toilet and bathing room, directional signage indicating the location of the nearest family/assisted use toilet or bathing room shall be provided where the family/assisted use room is provided in accordance with which section?

Section 1110.2.1

1112.3 Item 4

Stabilized adobe units must be used in adobe walls for the first what minimum distance above the finished first-floor elevation?

4 inches (102 mm)

2109.2.4.5.2

What is the maximum allowable building height in feet for a Type IIB construction building classified as Group E that is equipped throughout with an automatic sprinkler system (S)?

75

Table 504.3

Deferred submittal items shall not be installed until the corresponding documents have been:

Approved by the building official

107.3.4.1

Balusters, panel fillers, and guard infill components shall be designed to resist a concentrated load of:

50 pounds (0.22 kN)

1607.9.1.2

For Asphalt shingles installed on a roof slope between 2:12 and 4:12 where the maximum basic wind speed (V) is less than 130 mph, the two layers of underlayment shall overlap successive sheets half the width of a full sheet plus:

2 inches

1507.1.1

For water closets designed for assisted toileting, the centerline of the water closet shall be not less than 24 inches (610 mm) and not greater than what maximum distance from one side of the required clearance?

26 inches (660 mm)

1110.2.2.1

Where shallow foundations will bear on compacted fill material more than 12 inches in depth, the geotechnical investigation must include test methods to be used to determine the maximum dry density and optimum moisture content of the material to be used as:

compacted fill.

1803.5.8 Item 3

What is the maximum number of years required for the building official to retain official records, unless otherwise provided by other regulations?

5 years

104.7

An incidental use classified as a Furnace room where any piece of equipment is over 400,000 Btu per hour input requires which minimum protection?

1 hour or provide automatic sprinkler system

Table 509.1

Where means of egress from stories above and below converge at an intermediate level, the capacity from the point of convergence shall be not less than the largest minimum width or the sum of the required capacities for the stairways or ramps serving the two adjacent stories, whichever is:

larger

1005.6

If a skylight is not rated separately for positive and negative pressure, the performance grade rating shown on the label shall be the rating determined in accordance with AAMA/WDMA/CSA 101/I.S.2/A440 for:

both positive and negative design pressure.

2405.5

Mortar for masonry construction must conform to Articles 2.1 and 2.6 A of which standard?

TMS 602

2103.2.1

Asphalt shingles not included in the scope of ASTM D7158 must be tested and labeled in accordance with which standard?

ASTM D3161

1504.2 Exception

The upper edge of the cleanout opening in a masonry chimney shall be located not less than 6 inches (152 mm) below the:

lowest chimney inlet opening

2113.18

For steel frame structures designed using Load and Resistance Factor Design (LRFD), end connections of all beams and girders must have a minimum nominal axial tensile strength equal to what portion of the required shear strength, but not less than 10 kips?

two-thirds

1616.2.2.2

A Class I interior floor finish material must have a minimum critical radiant flux of:

0.45 watts/cm2 or greater

804.2

An automatic sprinkler system is required throughout all buildings containing a Group F-1 occupancy where the combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds:

24,000 square feet (2230 m2)

903.2.4

Vehicle barriers for passenger vehicles shall be designed to resist a concentrated load of:

6,000 pounds (26.70 kN)

1607.11

In Type IV-A construction, the interior faces of all mass timber elements must be protected with noncombustible protection contributing a minimum assigned time of not less than:

80 minutes

602.4.1.2.1

Where direct access for pedestrians is provided from parking structures to buildings, the entrance shall be accessible, as specified in which section?

1105.1.2

1105.1.2

In office buildings where partition locations are subject to change, the partition load shall be not less than a live load of:

15 pounds per square foot (psf)

1607.5

In occupancies other than Groups H and I, which are no more than two stories above grade plane and are equipped throughout with an automatic sprinkler system, a mezzanine having two or more exits or access to exits is:

Not required to be open to the room

505.2.3 Exception 5

A parapet wall must have noncombustible faces for the uppermost minimum of:

18 inches (457 mm)

705.12.1

BIPV shingles shall be listed and labeled in accordance with which UL standard?

UL 7103

1507.16.6

Ramped aisles having a slope exceeding one unit vertical in 15 units horizontal (6.7-percent slope) and stepped aisles shall be provided with handrails located either at one or both sides of the aisle or:

within the aisle width

1030.16

The refractory brick lining for medium-heat appliance chimneys must start not less than what minimum distance below the lowest chimney connector entrance?

2 feet (610 mm)

2113.11.2.2

According to Table 1705.2.4, which type of special inspection is required for standard bridging of open-web steel joists?

Periodic special inspection.

Table 1705.2.4 Item 1.b.1

Exterior walls and openings adjacent to an exterior egress balcony must be protected in accordance with Section 705 based on fire separation distance if the fire separation distance is less than:

10 feet (3048 mm)

1021.4

For a fire partition (other than corridor walls) with a 1-hour required fire-resistance rating, what is the minimum required fire door assembly rating?

3/4 hour

Table 716.1(2)

In unlimited area Group A-4 occupancies used for participant sports areas where the automatic sprinkler system is not required in the sports area, what must be provided in storage rooms, press boxes, and concession booths ancillary to the sport activity space?

An automatic sprinkler system

507.4 Exception 2

In Type IV-B construction, unprotected portions of mass timber walls shall be not less than what distance from unprotected portions of other walls measured horizontally along the floor?

15 feet (4572 mm)

602.4.2.2.4

What is the required protection type for pedestrians when the height of construction is more than 8 feet and the distance from construction to the lot line is less than 5 feet?

Barrier and covered walkway

Table 3306.1

What classification applies to heavy timber frame-supported structures covered by an approved membrane in accordance with Section 3102.3.1?

Type IV-HT construction.

3102.3

An Institutional Group I-1 facility housing not fewer than six and not more than 16 persons receiving custodial care shall be classified as which occupancy group?

Group R-4

308.2.3

Fiber-reinforced polymer (FRP) used on exterior walls must comply with Section 2603.5, unless the FRP does not exceed an aggregate total of 20 percent of the area of the specific wall, and single architectural elements do not exceed what maximum percentage of the specific wall area?

10 percent

2613.5 Exception 1.1

Where provided, lightning protection systems must comply with Sections 2703.2 through which other section?

2703.3

2703.1

If the building official serves a written notice for an unsafe condition, the notice shall require the notified person to declare immediately to the building official their acceptance or rejection of the terms of the:

Order

116.3

A Data Center is used primarily to house information technology equipment (ITE) and serves a total ITE load greater than 10 kW and:

20 W/ft2 (215 W/m2) of conditioned floor area

202 [BG] Data Center

According to Table 2607.4, for a fire separation distance of 11 or more feet but less than or equal to 30 feet, what is the maximum percentage area of the exterior wall permitted for CC1 light-transmitting plastic wall panels?

25 percent

Table 2607.4

The interior finish of walls and ceilings of the atrium shall be not less than:

Class B

404.8

Which fastener material is acceptable for all types of metal roofs?

Stainless steel

1507.4.4

An approved agency must have adequate equipment to perform required tests, and this equipment must be:

periodically calibrated.

1703.1.2

Where more than one exit or exit access doorway is required, dead-end corridors shall not exceed what maximum length?

20 feet (6096 mm)

1020.5

A shaft enclosure connecting four stories or more must have a fire-resistance rating of not less than:

2 hours

713.4

In separated occupancies, the required separation between Group R and Group F-1 (nonsprinklered) is:

2 hours

Table 508.4

The vertical leg of drip edges for shingle roofs shall be not less than 11/2 inches in width and shall extend not less than 1/4 inch below sheathing, and the drip edge shall extend back on the roof not less than:

2 inches (51 mm)

1507.2.8.3

According to Table 1504.8, for an aggregate-surfaced roof using ASTM D1863 (No. 6) aggregate, a mean roof height of 50 ft, and a basic wind speed (V) of 130 mph in Exposure C, what is the minimum required parapet height (in inches)?

29

1504.8

For buildings designed using conventional light-frame construction, the maximum floor-to-floor height shall not exceed:

11 feet, 7 inches (3531 mm)

2308.2.2

Low-level exit signs required in Group R-1 occupancies must have the bottom of the sign located not less than 10 inches (254 mm) nor more than what maximum distance above the floor level?

18 inches (455 mm)

1013.2

A sign notifying patrons of the availability of assistive listening systems shall include which specific symbol?

International Symbol of Access for Hearing Loss

1112.4 Item 1

What is the maximum exit access travel distance permitted from a first story above grade plane with a Group B occupancy (other than R-2) served by a single exit?

125 feet

Table 1006.3.3

The common path of egress travel for a room or space used for assembly purposes having fixed seating shall not exceed what maximum distance from any seat to a point where an occupant has a choice of two paths of egress travel to two exits?

30 feet (9144 mm)

1030.8

Apartment houses and dormitories where occupants are primarily permanent in nature and containing more than two dwelling units are classified as which Residential Group?

Group R-2

310.3

Special inspections and tests shall be required for proposed work that is, in the opinion of the building official, unusual in its nature, such as construction materials and systems that are alternatives to materials and systems prescribed by:

this code.

1705.1.1

In Group I-1, Condition 1 occupancies, at least what percentage, but not less than one, of the dwelling units and sleeping units shall be Accessible units?

4 percent

1108.5.1.1

If a room contains both a mezzanine and an equipment platform, the aggregate area of the two raised floor levels shall be not greater than what fraction of the floor area of the room?

Two-thirds

505.2.1.1

For rigid tile roof coverings, the single lapped interlocking tile must have a minimum head lap of not less than:

2 inches (51 mm)

1609.6.3.1

Combustible exterior wall coverings constructed of fire-retardant-treated wood complying with Section 2303.2 for exterior installation shall be permitted up to what maximum height above grade plane regardless of the fire separation distance?

60 feet (18 288 mm)

1405.1.1

According to Table 1705.6, verifying materials below shallow foundations are adequate to achieve the design bearing capacity requires which type of inspection?

Periodic special inspection.

Table 1705.6 Item 1

What is the required interior wall and ceiling finish classification for corridors and enclosures for exit access stairways in a nonsprinklered Group H occupancy?

Class A

Table 803.13

In an exterior room used for the storage of medical gases, the room must be provided with at least two vents, one of which must be within what maximum distance of the floor?

6 inches (152 mm)

427.2.1

Special inspections for wind resistance are required for buildings in wind Exposure Category B where basic wind speed, is what minimum speed?

150 mph (67 m/sec) or greater.

1705.12 Item 1

Special amusement areas having an occupant load of less than 50 shall comply with the requirements for which occupancy group?

Group B

411.1

Foam plastic insulation complying with ASTM C578 and ASTM C1289 and used as exterior wall sheathing on framed wall assemblies must comply with ANSI/SBCA FS 100 for:

wind pressure resistance.

2603.1

Buildings containing materials that pose a deflagration hazard, such as Class I flammable liquids stored in normally open containers, shall be classified as which High-Hazard Group?

Group H-2

307.4

Fiber-reinforced polymer (FRP) packages and containers delivered to the job site must bear the label of an approved agency showing the manufacturer’s name, product listing, product identification, and what other information?

Information sufficient to determine that the end use will comply with the code requirements.

2613.2

Continuous special inspection is required during field gluing operations of elements of the:

main windforce-resisting system.

1705.12.1

Area wells with a vertical depth of more than 44 inches (1118 mm) shall be equipped with an approved permanently affixed ladder or steps. The ladders or rungs shall be spaced not more than what distance on center (o.c.) vertically for the full height of the area well?

18 inches (457 mm)

1031.5.2.1

In a Two-Span Continuous Pattern for lumber decking, how many supports must all pieces be supported by?

Three supports

2304.9.2.2

For polypropylene siding, the certification of the flame spread index must be accompanied by a test report stating that all portions of the test specimen ahead of the flame front remained in position during the test in accordance with:

ASTM E84 or UL 723

1403.11.1

What is the minimum vertical attachment flange required for a corrosion-resistant weep screed?

3 1/2 inches (89 mm)

2512.1.2

The aggregate width of openings at any floor level through a fire wall shall not exceed what percentage of the length of the wall?

25 percent

706.8

Single-ply membrane roofs shall have a design slope of not less than what minimum units vertical in 12 units horizontal for drainage?

1/4 unit

1507.12.1

Light-transmitting plastic covers on solar collectors having noncombustible sides and bottoms are permitted on buildings not over three stories above grade plane or 9,000 square feet (836.1 m2) in total floor area, provided the cover does not exceed what maximum percentage of the roof area for CC1 materials?

33.33 percent

2606.12

What is the maximum allowable building height in feet for a sprinklered (S) Group B occupancy of Type IV construction?

270 feet

Table 504.3

What is the minimum thickness required for galvanized steel corner beads used in gypsum-protected structural steel columns with sheet steel column covers for fire-resistance ratings of 2 hours or less?

Not specified, but the legs must be 1 1/2 inches

Figure 722.5.1(2) Note 2

Where Group R-2 facilities are without elevator service, at least how many stories containing units intended to be occupied as a residence must be provided with an accessible entrance from the exterior, and all units on that story must be Type B units?

At least one story

1108.7.1.1

Class A roof assemblies include minimum 16 ounce per square foot copper sheets installed over:

combustible decks

1505.2 Exception 3

Structural standing-seam metal panel roof systems that function as both the roof deck and roof covering shall be tested in accordance with FM 4474 or:

ASTM E1592

1504.4.2

For a horizontal wood-frame gypsum panel product diaphragm ceiling made of 1/2-inch material spaced at 16 inches on center, what is the maximum shear value permitted in plf of ceiling?

90

Table 2508.6

Buildings whose primary occupancy is public assembly with an occupant load greater than 300 are assigned to which risk category?

Risk Category III

1604.5

For 3-inch and 4-inch sawn tongue-and-groove decking, in addition to toenailing and face-nailing to the supports, courses must be spiked to each other with 8-inch spikes at maximum intervals of:

30 inches (762 mm)

2304.9.5.2

BIPV shingles shall be installed on roof slopes of not less than what minimum units vertical in 12 units horizontal?

2 units

1507.16.2

Where are laboratory suites specifically NOT permitted according to Table 428.3?

Floors 21+ Above Grade Plane

Table 428.3

In Group A occupancies having an occupant load of 300 or less, key-operated locking devices are permitted on the main exterior doors provided a sign is posted on the egress side stating “THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED.” What is the minimum required letter height for this sign?

1 inch (25 mm)

1010.2.4 Item 3.3

What is the maximum size permitted for a steel box used to terminate an electrical raceway serving the interior exit stairway and ramp as a permitted penetration?

16 square inches (0.010 m2)

1023.5

In fire partitions that penetrate corridors where corridor ceilings are permitted, a ceiling radiation damper must be provided where which element is penetrated?

The ceiling membrane of a fire-resistance-rated floor-ceiling or roof-ceiling assembly

717.5.4.1

The installation of replacement glass shall be as required for:

new installations.

2402.1

What hardware components are exempt from fire test requirements for elevator hoistway doors?

Approved interlocks, mechanical locks and electric contacts, door and gate electric contacts, and door-operating mechanisms

3002.1.2

Metal suspension systems for acoustical and lay-in panel ceilings must comply with ASTM C635 and which section of ASCE 7 for installation in high seismic areas?

Section 13.5.6

2506.2.1

An open parking garage of Type II construction with all sides open shall be unlimited in allowable area where the building height does not exceed:

75 feet (22 860 mm)

406.5.5

For a pair of doors required to comply with Section 716 (fire doors) in a Group B, F, or S occupancy serving less than 50 people, which type of latching device is Permitted on the inactive leaf?

Constant latching bolts

Table 1010.2.4

The clear height above and below the mezzanine floor construction shall be not less than:

7 feet (2134 mm)

505.2

Metal composite material (MCM) must be separated from the interior of a building by an approved thermal barrier consisting of 1/2-inch gypsum wallboard or material tested in accordance with and meeting the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of:

NFPA 275

1406.10.2

Masonry chimneys must have a concrete, metal, or stone cap, sloped to shed water, a drip edge, and a caulked bond break around any flue liners in accordance with which ASTM standard?

ASTM C1283

2113.9.1

The minimum mechanical exhaust ventilation rate required throughout portions of a Group H-5 fabrication area where HPM are used or stored is not less than:

1 cfm per square foot

415.11.1.6

Where a building or portion of a building is required to be accessible, at least one accessible route shall be provided to each portion of the building, to accessible building entrances connecting accessible pedestrian walkways and to the:

public way

1104.3

Shower compartments and walls above bathtubs with installed shower heads shall be finished with a smooth, nonabsorbent surface to a height not less than what minimum distance above the drain inlet?

72 inches (1829 mm)

1210.2.4

A Building or structure is deemed to have sustained Substantial Damage if the cost of restoring it to its before-damaged condition would equal or exceed what percentage of the structure’s market value before the damage occurred?

50 percent

202 [BS] Substantial Damage

Where requested by the registered design professional, the steel joist manufacturer must submit design calculations with a cover letter bearing the seal and signature of the joist manufacturer’s:

registered design professional

2207.3

According to Table 1404.2, what is the minimum nominal thickness required for adhered masonry veneer?

0.25 inches

1404.2

The specified compressive strength of concrete used for tie beams in adobe construction must be not less than:

2,500 psi (17.2 MPa)

2109.2.4.7.1

At least how many companion seats shall be provided for each wheelchair space required by Sections 1109.2.2.1 through 1109.2.2.3?

At least one companion seat

1109.2.3

In buildings equipped throughout with an automatic sprinkler system, plastic light-diffusing systems shall be protected both above and below unless the system is specifically approved for installation only above the system, or the light-diffusing system is listed and labeled in accordance with which standard?

UL 723S

2606.7.4

Who must employ one or more approved agencies to provide special inspections and tests during construction when application is made for construction?

The owner or the owner's authorized agent, other than the contractor.

1704.2

Where required, glazing shall be tested in accordance with CPSC 16 CFR Part 1201 and must comply with the test criteria for which Category, unless otherwise indicated in Table 2406.2(1)?

Category II

2406.2

Who is responsible for conducting a daily fire safety inspection at the project site?

The site safety director

3302.3

The deflection of a blocked wood structural panel diaphragm uniformly fastened throughout with staples is permitted to be calculated using Equation 23-1, where the constant in the third term is:

0.188

2305.2

Concrete masonry units, clay or shale masonry units, stone masonry units, glass unit masonry, and AAC masonry units must comply with Article 2.3 of:

TMS 602

2103.1

What is the Live Load Element Factor required for interior columns?

4

1607.13.1

Unless structural support and anchorage are provided, the center of gravity of projecting masonry or molded cornices must lie within what portion of the supporting wall?

the middle one-third

2104.1.2

In the horizontal building separation allowance, the building or buildings above the horizontal assembly shall be of which Group occupancies?

Group A, B, M, R or S

510.2

Mobile or portable amusement rides are:

not required to be accessible

1111.4.8 Exception

An opening shall be provided to any attic area having a clear height of over 30 inches (762 mm). What is the minimum size of this opening?

20 inches by 30 inches (559 mm by 762 mm)

1209.2

UL 96A shall not be utilized for buildings used for the production, handling, or storage of ammunition, explosives, flammable liquids, flammable gases, or what other materials?

other explosive ingredients including dust

2703.2

For driven deep foundation elements where allowable loads exceed 40 tons, the wave equation method of analysis must be used, and the allowable loads must be verified by load tests in accordance with:

Section 1810.3.3.1.2

1810.3.3.1.1

For anchored stone veneer with concrete or masonry backing, anchor ties must be placed so that the eyes or loops are 12 inches maximum on center in both directions, and a corrosion-resistant wire tie must be threaded through the exposed loops for every:

2 square feet of stone veneer

1404.8

Buildings and other structures, and parts thereof, shall be designed and constructed to support safely the factored loads in load combinations without exceeding the appropriate strength limit states for the materials of construction, which is known as:

strength design

1604.2

Water-resistant gypsum backing board shall not be used in which of the following locations?

Over a vapor retarder in shower or bathtub compartments, or areas subject to continuous high humidity

2509.3

In flood hazard areas where design flood elevations are specified but floodways have not been designated, the cumulative effect of proposed encroachment shall not increase the design flood elevation more than:

1 foot (305 mm) at any point.

1804.5 Item 4

Special inspections for fire-resistant penetrations and joints are required in fire areas containing Group R occupancies with an occupant load greater than:

250

1705.18

What is the minimum required fire-resistance rating in hours for the floor construction in a Type IIB building?

0

Table 601

Where plastic cement or masonry cement is used in exterior plaster, what restriction applies regarding additional lime or plasticizers?

Additional lime or plasticizers shall not be added

2512.2

In Group B and M occupancies, nonpublic aisles serving less than 50 people and not required to be accessible need not exceed what minimum width?

28 inches (711 mm)

1018.3 Exception

The occupant load of seating booths shall be based on one person for each what minimum length of booth seat measured at the backrest?

24 inches (610 mm)

1004.6

For roof planking that uses end-matched or splined 2-inch tongue-and-groove planking with randomly spaced joints, the system must be applied to not less than how many continuous spans?

Three continuous spans

2308.11.11

In Type IV-C construction, shafts and elevator hoistway enclosures shall be protected with noncombustible protection having a minimum assigned time of 40 minutes on both the inside of the shaft and the outside of the shaft, as specified in:

Table 722.7.1(1)

602.4.3.6

Where elevators are not a component of the accessible means of egress, what must the emergency sign adjacent to the call station read?

IN CASE OF FIRE, ELEVATORS ARE OUT OF SERVICE. USE EXIT

3002.3

Incidental uses shall not occupy more than what percentage of the building area of the story in which they are located?

10 percent

509.3

What material is accepted as an approved thermal barrier, having a thickness of 1/2 inch (12.7 mm)?

Gypsum wallboard

2603.4

The cost of all tests and other investigations required under the provisions of this code shall be borne by the owner or the:

owner's authorized agent.

1707.1

Where approved by the building official, the occupant load for concentrated business use areas (like call centers or trading floors) shall be the actual occupant load, but not less than one occupant per what area?

50 square feet (4.65 m2)

1004.8

Joint and fastener treatment is generally not required where the gypsum panel product is to receive a decorative finish such as wood paneling, battens, acoustical finishes, or any similar application that would be equivalent to:

joint treatment.

2508.5 Exception

Structural tolerances for precast concrete structural elements must be in accordance with which standard?

ACI ITG-7

1901.7.2

Means of egress ramps shall have a minimum headroom clearance of not less than what distance above the finished floor of the ramp run?

80 inches (2032 mm)

1012.5.2

The total area of one or more vision panels in any elevator hoistway door shall be not more than:

85 square inches (54 839 mm2).

2409.3

According to Table 1404.15.2, for an ultimate design wind speed of 105 MPH (Case 2, without interior gypsum wallboard), what is the adjusted minimum design wind pressure (ASD) in psf required for vinyl siding installed over foam plastic sheathing alone in Exposure B?

-41.4

1404.15.2

Screens are required to be installed below the full area of the glazing material for monolithic systems using heat-strengthened glass and:

fully tempered glass.

2405.3.1

Where cladding is attached directly over foam sheathing to 33 mil cold-formed steel framing using a #10 screw, with a cladding weight of 18 psf and a fastener vertical spacing of 6 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.2.1 (assuming 16 inches on center horizontal spacing)?

2.7

1404.5.2.1

For open valleys (valley lining exposed) lined with metal for asphalt shingles, the valley lining shall be not less than what minimum width?

24 inches (610 mm)

1507.2.8.2

Where required exterior openings for ventilation open into a sunroom with thermal isolation, the openable area between the sunroom addition and the interior room shall have an area of not less than 8 percent of the interior room floor area, but not less than how many square feet?

20 square feet (1.86 m2)

1202.5.1.1 Exception

Where the allowable stress design load combinations of ASCE 7, Section 2.4 are used, and flat roof snow loads exceed 45 pounds per square foot, what percentage of the snow load shall be combined with seismic loads?

15 percent

1605.1 Exception 2

Openings in exterior walls required to be fire-resistance rated surrounding the perimeter of the pedestrian walkway connection must be equipped with opening protectives providing what minimum fire protection rating?

Not less than 3/4-hour.

3104.5.1.2

Gypsum plaster shall not be used on which surfaces?

Exterior surfaces

2512.3

Where interior finish materials are applied to furring strips in noncombustible or fire-resistance-rated construction, the intervening spaces between the furring strips shall be fireblocked at not greater than what distance in every direction?

8 feet (2438 mm)

803.15.1.1

In continuous loading zones, one passenger loading zone in every continuous how many linear feet (m) maximum of loading zone space shall be accessible?

100 linear feet (30.4 m)

1106.9.1

In multipane glazed assemblies, individual panes not exceeding 1 square foot (0.09 m2) in exposed area must have one pane or more marked per Section 2406.3, and other panes must be marked “CPSC 16 CFR Part 1201” or:

"ANSI Z97.1"

2406.3.1

Extruded Polystyrene (XPS) used as foam plastic insulating sheathing must comply with which ASTM standard?

ASTM C578

Table 2603.1.2

Sections of exterior plastic veneer shall not exceed 300 square feet (27.9 m2) in area and shall be separated by not less than what minimum vertical distance?

4 feet (1219 mm)

2605.2

For a helipad, the takeoff weight limitation must be indicated in units of thousands of pounds and placed in a box that is located in the bottom right corner of the landing area, and this box shall be not less than what minimum height?

5 feet (1524 mm)

1607.6

What is the tabular allowable area factor (At) for a Group S-1 occupancy of Type IIA construction that is two or more stories above grade plane and equipped throughout with an automatic sprinkler system (SM)?

78,000 square feet

Table 506.2

What existing dwelling type is specifically exempted from the provisions of Section 3113 governing relocatable buildings?

Manufactured housing used as dwellings.

3113.1 Exception

The enclosed fire service access elevator lobby must have direct access to which other means of egress component?

An enclosure for an interior exit stairway or ramp

3007.6.1

An attached garage for storage of passenger vehicles must be separated from the covered or open mall building or anchor building by not less than:

2-hour fire barriers

402.4.2.3

Where standby power is connected to elevators, what must also be connected to the standby power source?

The machine room ventilation or air conditioning

3003.1.4

Where serving technical production areas, the maximum common path of travel permitted where two means of egress are required is:

100 feet (30 480 mm)

410.5.3.3

Where the inside surface of the smoke chamber is formed by corbeled masonry, the walls shall not be corbeled more than how many degrees from vertical?

30 degrees (0.52 rad)

2111.9.1

What is the required separation in hours between a nonsprinklered (NS) Group F-1 occupancy and a nonsprinklered (NS) Group R occupancy?

2

Table 508.4

Where openings below grade provide required natural ventilation, the outside horizontal clear space measured perpendicular to the opening shall be what minimum ratio of the depth of the opening?

one and one-half times

1202.5.1.2

A building or tenant space used for assembly purposes with an occupant load of less than 50 persons shall be classified as which occupancy group?

Group B

303.1.1

Regardless of the FSI, the maximum smoke-developed index (SDI) permitted for Class A, B, or C interior wall and ceiling finish materials is:

450

803.1.2

What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group R-2 of Type IVB construction?

12

Table 504.4

For buildings with a mean roof height less than or equal to 30 feet, Exposure B shall apply where Surface Roughness B prevails in the upwind direction for a distance of not less than:

1,500 feet (457 m)

1609.4.3

Liquid storage rooms and rooms for flammable or combustible liquid use in closed systems having a floor area of not more than what size need NOT be located on the outer perimeter of an unlimited area building?

1,000 square feet (93 m2)

507.8.1.1.2

In Group I-2 occupancies, the corridors in Condition 1 occupancies shall be equipped with an:

Automatic fire detection system

407.9

No. 15 asphalt felt and water-resistive barriers complying with ASTM E2556 shall be applied horizontally with the upper layer lapped over the lower layer not less than:

2 inches

1403.2

Special inspections and tests for intumescent fire-resistive materials applied to structural elements and decks shall be performed in accordance with which standard?

AWCI 12-B.

1705.16

Crawl spaces shall be provided with not less than one access opening that shall be not less than:

18 inches by 24 inches (457 mm by 610 mm)

1209.1

Where a column extends through a ceiling and requires protection, the encasement must be continuous from the top of the foundation or floor/ceiling assembly below, through the ceiling space, to the:

Top of the column

704.2

For care recipients confined to bed or a stretcher, the refuge area provided within a smoke compartment shall be not less than:

30 net square feet (2.8 m2) per person

407.5.3

Plastic composite deck boards and stair treads must bear a label indicating compliance with ASTM D7032 and include the allowable load and:

maximum allowable span determined by ASTM D7032.

2612.2

What is the minimum critical radiant flux classification required for interior floor finish materials in exit passageways in a Group A occupancy?

Class II

804.4.2

A permit issued shall become invalid if the work authorized on the site is suspended or abandoned for a period of how many days after the time the work is commenced?

180 days

105.5

In areas where the probability of termite infestation is very heavy, foam plastics shall not be installed on the exterior face or under interior or exterior foundation walls or slab foundations located below grade, unless exempted by one of three exceptions, including being installed on the interior side of what specific wall?

Basement wall

2603.8 Exceptions

What is the minimum clear height required for covered walkways?

8 feet (2438 mm)

3306.7

In Group I-2 nursing homes (Condition 1), at least what percentage, but not less than one of each type of the dwelling units and sleeping units shall be Accessible units?

50 percent

1108.5.2.1

Where concrete is cast in a steel pipe or where an enlarged base is formed by compacting concrete, the maximum size for coarse aggregate shall be:

3/4 inch (19.1 mm)

1810.3.2.1

A Mezzanine must be in accordance with which section of the code?

Section 505

202 [BG] Mezzanine

For greenhouses where special scaffolding is used, the minimum roof live load shall be not less than:

12 psf (0.58 kN/m2)

1607.14.1

Penthouses constructed on buildings of other than Type I construction shall not exceed what maximum height above the roof deck as measured to the average height of the roof of the penthouse?

18 feet (5486 mm)

1511.2.1

The deflection of reinforced concrete structural members shall not exceed that permitted by which referenced standard?

ACI 318

1604.3.2

Aluminum fascia must be not less than what minimum thickness?

0.019 inches (0.48 mm)

1412.7

According to Table 1705.3, inspecting single-pass fillet welds up to 5/16-inch maximum requires which type of inspection?

Periodic special inspection.

Table 1705.3 Item 2.e

What is the maximum allowable building height in feet for a nonsprinklered (NS) building classified as Group I-1 Condition 2 of Type IIIB construction?

55

Table 504.3

What is the required interior wall and ceiling finish classification for interior exit stairways and ramps in a nonsprinklered Group A-2 occupancy?

Class A

Table 803.13

Test methods and loads for glazed areas in racquetball and squash courts subject to impact loads require impacts to be applied at what height above the playing surface?

59 inches (1499 mm).

2408.2.1

The minimum interval required between the second coat and the finish coat of exterior cement plaster is:

7 days

Table 2512.6

The design, fabrication, and erection, including related connections and protective coatings, of steel cables for buildings must be in accordance with which standard?

ASCE 19

2214.1

An accessory room or space used for assembly purposes that is less than 750 square feet (70 m2) in area shall be classified as a Group B occupancy or:

As part of that occupancy

303.1.2

If foam plastic insulation is granted special approval based on large-scale tests such as FM 4880 or UL 1040, what requirement is it exempted from complying with?

The thermal barrier requirements of Section 2603.4 or the roofing requirements of Section 2603.6

2603.9

An exterior wall on a building of Type I, II, III or IV construction, greater than 40 feet in height above grade plane, containing a combustible water-resistive barrier must be tested in accordance with and comply with the acceptance criteria of:

NFPA 285

1402.6

For machinery, the weight of reciprocating machinery or power-driven units shall be increased by what percentage to allow for impact?

50 percent

1607.12.2

For design thicknesses 1 inch or greater, the minimum allowable individual SFRM thickness shall be the design thickness minus:

1/4 inch (6.4 mm).

1705.15.4.1

Aerial supports not greater than what maximum height as measured from the roof deck to the highest point on the aerial supports shall be permitted to be constructed of combustible materials?

12 feet (3658 mm)

1511.7.1 Exception

According to Table 1607.1, what is the minimum concentrated live load required at any point along primary structural members supporting roofs over manufacturing, storage warehouses, and repair garages?

2,000 pounds

1607.1

Special inspections and nondestructive testing of structural stainless steel elements shall be in accordance with the quality assurance inspection requirements of which standard?

AISC 370.

1705.2.2

The firebox floor of a masonry heater must be a minimum thickness of what minimum thickness of noncombustible material?

4 inches (102 mm)

2112.3

Access doors for automatic sprinkler system riser rooms and fire pump rooms must be labeled with an approved sign having letters of a minimum height of 2 inches (51 mm) and a minimum stroke of:

3/8 inch (10 mm)

902.1.2

Risers shall be solid, EXCEPT that for stairways not required to comply with Section 1009.3, the opening between treads shall not permit the passage of a sphere with a diameter of what maximum size?

4 inches (102 mm)

1011.5.5.3 Exception 1

Where minimum 1x wood furring is used to attach cladding over foam sheathing to a 33 mil cold-formed steel stud using a #10 screw, with a cladding weight of 11 psf and a fastener spacing in the furring of 12 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.2.2 (assuming 16 inches on center furring)?

2.25

1404.5.2.2

For fireplaces with chimneys up to 40 inches (1016 mm) wide in Seismic Design Category C or D, how many continuous vertical bars must be provided?

four No. 4 bars

2111.4.1

Dwelling units and sleeping units required to be Accessible units, Type A units, or Type B units shall comply with the applicable portions of Chapter 11 of:

ICC A117.1

1108.2

What is the required interior wall and ceiling finish classification for rooms and enclosed spaces in a sprinklered Group H occupancy?

Class C

Table 803.13

Where a glass wall forms a smoke partition enclosing an atrium, automatic sprinklers must be located between what range of distances away from the glass?

4 inches and 12 inches (102 mm and 305 mm)

404.6 Exception 1

If a conflict occurs between provisions of this code and a referenced code or standard, which provision shall apply?

The provisions of this code

102.4.1

Perimeter ties in bearing wall structures shall be located within what maximum distance of the edge of each floor and roof?

4 feet (1219 mm)

1616.3.2.3

If a hoistway is required to be enclosed, how must it be constructed?

As a shaft enclosure in accordance with Section 713

3002.1

For pedestrian walkways with open sides connecting the third or lower story of each building (and not protected by sprinklers), what is the maximum height the roof of the walkway can be above grade plane?

Not more than 40 feet (12 160 mm).

3104.5.3

Luminous egress path demarcation lines on stair landings and other floor areas shall be placed on the wall with the bottom edge of the stripe not more than what distance above the finished floor?

4 inches (102 mm)

1025.2.4.2

Where standby power is required or furnished to operate an elevator, how must the standby power be transferable to all elevators in each bank?

Manually transferable

3003.1.1

The unsupported height of any wall constructed of adobe units shall not exceed what maximum multiple of the wall thickness?

10 times

2109.2.4.4

Ramps with a rise greater than what distance shall have handrails on both sides?

6 inches (152 mm)

1012.8

According to Table 1412.6, for a wood structural panel soffit (3/8 minimum performance category) with a maximum design pressure of ± 50 psf, what is the maximum fastener spacing permitted for galvanized steel along edges and intermediate supports when using a 6d box nail?

4 inches

1412.6

Pipes, wires, conduits, ducts, or other service facilities shall NOT be embedded in the required fire protective covering of a structural member that is required to be:

Individually encased

704.7

According to Table 1705.7, for steel driven deep foundation elements, additional special inspections must be performed in accordance with which section?

Section 1705.2.

Table 1705.7 Item 5

Dampproofing materials for floors installed beneath the slab must consist of not less than 6-mil polyethylene with joints lapped not less than:

6 inches (152 mm)

1805.2.1

A building or structure in which vertical loads from floors and roofs are primarily supported by walls is defined as a:

Bearing wall structure

202 [BS] Bearing Wall Structure

A fire watch shall be provided for new multistory construction with an aggregate area exceeding what maximum size per story?

50,000 square feet (4645 m2)

4645 m2

For structures assigned to Seismic Design Category D, E or F, individual spread footings founded on Site Class E or F shall be interconnected by ties, unless equivalent restraint is provided by reinforced concrete beams within slabs on grade or:

reinforced concrete slabs on grade

1809.13

Where repairs, alterations, or additions are made during the restoration of a structure deemed unsafe, those actions must comply with the requirements of the:

International Existing Building Code

116.5

What is the maximum permitted classification for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby?

Class C

Table 803.13 Note d

As an alternative uniform live load reduction, for live loads not exceeding 100 psf, the reduction in percent shall not exceed 60 percent for members supporting:

two or more floors

1607.13.2 Item 1.2

For unvented attics in Climate Zone 4A or 4B, what is the minimum R-value of air-impermeable insulation required, expressed as a percentage of the total R-value?

30%

Table 1202.3

If an enclosed elevator lobby is used to provide hoistway door protection using smoke partitions, what smoke and draft control requirements must the doors comply with?

Sections 710.5.2.2, 710.5.2.3, and 716.2.6.1

3006.3

Structural through-fastened metal panel roof systems shall be tested in accordance with ASTM E1592, UL 580 or:

FM 4474

1504.4.2

What is the minimum design live load required for walkways provided for pedestrian travel?

150 psf (7.2 kN/m2)

3306.2

Self-adhered membranes used as flashings of fenestration in exterior wall assemblies must comply with which standard?

AAMA 711

1404.4

What is the minimum corridor width (in inches) required for a facility not otherwise listed in the table?

44

Table 1020.2

Where partitions or other obstructions do not separate adjacent water closets, urinals, or bidets, what is the minimum required center-to-center distance between adjacent fixtures?

30 inches (762 mm)

2903.1.1

Standby power systems must automatically provide secondary power within what maximum time after primary power is lost, unless specified otherwise in this code?

60 seconds

2702.1.4

What is the minimum required fire-resistance rating in hours for interior nonbearing walls and partitions in a Type IA building?

0

Table 601

Required anchors in masonry walls of hollow units or cavity walls shall be embedded in a:

reinforced grouted structural element of the wall

1604.8.2

Where concrete and clay roof tiles do not satisfy the limitations in Chapter 16 for rigid tile, a wind tunnel test shall be used to determine the wind characteristics of the roof covering in accordance with SBCCI SSTD 11 or:

ASTM C1569

1504.3.1.2

Interior floor finish materials of a traditional type, such as wood, vinyl, linoleum or terrazzo, are exempt from which general requirement?

Complying with Sections 804.2 through 804.4.2

804.1 Exception

The legal occupancy of a structure existing on the date of adoption shall be permitted to continue without change, except as otherwise specifically provided in the code, the International Existing Building Code, the International Fire Code, or the:

International Property Maintenance Code

102.6

Where used to enclose tanks or elevators that travel to the roof level, penthouses shall be permitted to have a maximum height of what distance above the roof deck?

28 feet (8534 mm)

1511.2.1 Exception

According to Table 1705.3, what type of special inspection is required to inspect concrete and shotcrete placement for proper application techniques?

Continuous special inspection.

Table 1705.3 Item 7

Anchorage of roof to walls and columns, and of walls and columns to foundations, shall be provided to resist the uplift and sliding forces that result from the application of the:

prescribed loads

1604.8.1

In aircraft manufacturing facilities of Type I or II construction, for a height of 50 feet (15 240 mm) or more and a manufacturing area of 200,000 square feet (18 580 m2) or more, what is the maximum exit access travel distance permitted?

500 feet

Table 412.6

In visiting areas in judicial facilities and Group I-3, at least what percentage, but not less than one of the cubicles, shall be accessible on both the visitor and detainee sides?

5 percent

1110.15.1

What is the maximum encroachment permitted for windows, balconies, architectural features, or mechanical equipment, regardless of the calculation based on increased height above 8 feet?

The maximum encroachment shall be 4 feet (1219 mm).

3202.3.2

What collected water is prohibited from flowing over a public walking surface?

Drainage water collected from a roof, awning, canopy or marquee, and condensate from mechanical equipment.

3201.4

Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads, and such attachment shall not be accomplished by the use of:

toenails or nails subject to withdrawal

1604.8.3

Fire department glass access panels must be constructed of:

tempered glass.

2406.5

According to Table 1807.1.6.3(2) for 8-inch nominal masonry walls (7.63 inches actual thickness), what is the minimum vertical reinforcement required for a 9-foot, 4-inch maximum wall height, 6-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft?

#6 at 48 inches

1807.1.6.3

Nonclassified roof coverings shall be permitted on buildings of Group U occupancies where there is a minimum fire-separation distance of what minimum distance measured from the leading edge of the roof?

6 feet

1505.1

Glazing not in doors or enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers shall be permitted to be tested in accordance with which standard?

ANSI Z97.1.

2406.2

For cold-formed steel trusses with clear spans 60 feet (18 288 mm) or greater, who must contract with a registered design professional for the design of the temporary installation restraint/bracing and the permanent individual truss member restraint/bracing?

The owner or the owner's authorized agent

2206.1.3.2

Which of the following conditions is specifically deemed an unsafe condition?

A vacant structure that is not secured against unauthorized entry

116.1

To resist the effects of mislocation, compressive overload of deep foundation elements is permitted to what maximum percentage of the allowable design load?

110 percent

1810.3.1.3

The bedding coat for exterior surfaces of exposed aggregate plaster shall have a minimum compressive strength of:

1,000 psi (6895 kPa)

2513.3

Emergency power systems provided for means of egress illumination must be capable of powering the required load for a duration of not less than how long?

90 minutes

2702.2.14

Light-transmitting plastic diffusers must be supported by noncombustible hangers that are not less than what minimum gauge size?

No. 12 steel-wire gage (0.106 inch)

2606.7.1

In Seismic Design Category D, E or F, where wood shear wall design values exceed 350 pounds per linear foot, framing members receiving edge fastening from abutting panels must be not less than what minimum assembly?

A single 3-inch nominal member, or two 2-inch nominal members

2306.3(1)

In structures assigned to Seismic Design Category A or B, what is the seismic reinforcement requirement for masonry chimneys?

seismic reinforcement is not required

2113.3

For masonry foundation walls designed using the prescriptive method, masonry units shall be laid in running bond and installed with which mortar type or greater in accordance with Section 2103.2.1?

Type M or S

1807.1.6.3 Item 7

Encroachments into the public right-of-way above grade and below 8 feet (2438 mm) in height are generally prohibited, but which components are specifically required not to open or project into the public right-of-way?

Doors and windows.

3202.2

For anchor bolts attaching cold-formed steel track to concrete, the anchors must be embedded into concrete a minimum of:

7 inches (178 mm)

1905.7.2 Exception 2.2

Unstabilized adobe units must have an average modulus of rupture of what minimum value?

50 psi (345 kPa)

2109.2.1.2

At least what percentage, but not less than one, of each type of firing position at shooting facilities shall be accessible?

5 percent

1111.4.15

According to Table 1505.1, what is the minimum roof assembly fire classification required for Type IIIB construction?

Class C

1505.1

In lieu of a grade mark on the material, a certificate of inspection is permitted to be accepted for precut, remanufactured, or rough-sawn lumber and for sizes larger than what nominal thickness?

3 inches (76 mm)

2303.1.1.1

At wide-flanged columns, thickness measurements of SFRM shall be made at how many locations around the column at each end of a 12-inch length?

12

1705.15.4.8

An automatic sprinkler system shall be provided in metallic and noncombustible nonmetallic exhaust ducts conveying flammable gases, vapors, or fumes where the largest cross-sectional diameter is equal to or greater than:

10 inches (254 mm)

415.11.12.1

Which occupancy group is exempt from the requirement for space heating systems?

Group F

1203.1 Exceptions

Thresholds at doorways shall not exceed 1/2 inch (12.7 mm) in height above the finished floor or landing for non-sliding doors, or what maximum height for sliding doors serving dwelling units?

3/4 inch (19.1 mm)

1010.1.6

In buildings four or more stories above grade plane, one stairway shall extend to the roof surface unless the roof has a slope steeper than:

four units vertical in 12 units horizontal (33-percent slope)

1011.12

A bonding agent approved by the SFRM manufacturer must be applied to a primed, painted or encapsulated surface where the bond strengths are found to be:

less than required values.

1705.15.6.3

A building, room, or space used for assembly purposes that has an occupant load of greater than 300 must be provided with a main exit that is of sufficient capacity to accommodate not less than what fraction of the occupant load?

one-half

1030.2

Balconies on upper levels of an open mall shall not project into the required open space width of not less than:

20 feet (6096 mm)

402.4.3

What is the maximum projection permitted for belt courses, lintels, sills, architraves, pediments and similar architectural features below 8 feet in height?

Not project more than 4 inches (102 mm).

3202.2.2

According to Table 2607.4, for a fire separation distance of over 30 feet, what is the minimum vertical separation required between CC2 light-transmitting plastic wall panels?

6 feet (1829 mm)

Table 2607.4

For pivoted or side-hinged doors not required to have a fire protection rating, the foam plastic insulation core must have a flame spread index of 75 or less, a smoke-developed index of 450 or less, and the door facing must be of steel having a minimum base metal thickness of:

0.016 inch (0.4 mm)

2603.4.1.7

What are the projection limitations for footings of street walls or their supports that are located not less than 8 feet (2438 mm) below grade?

Not project more than 12 inches (305 mm) beyond the street lot line.

3202.1.1

Impervious surfaces within 10 feet of the building foundation shall be sloped not less than what minimum percentage away from the building?

2 percent

1804.4

Concrete and masonry chimneys containing more than one passageway must have the liners separated by a minimum what thickness of concrete or solid masonry wall?

4 inches (102 mm)

2113.11.2.3

Standby power systems shall be provided for elevators and platform lifts as required in Sections 1009.4.1, 1009.5, 3003.1, 3007.8 and which other section?

Section 3008.8

2702.2.2

As an alternative to surface-burning characteristics testing, reflective plastic core insulation must comply with the acceptance criteria of Section 803.1.1.1 when tested in accordance with NFPA 286 or which other standard?

UL 1715

2614.4

Where excavation will reduce support from any foundation, who must prepare an assessment of the structure?

A registered design professional

1803.5.7

For an interior exit stairway and ramp connecting less than four stories, the minimum fire-resistance rating shall be not less than:

1 hour

1023.2

Soffits and fascias at roof overhangs must be capable of resisting the component and cladding loads for walls determined in accordance with Chapter 16 using an effective wind area of:

10 square feet (0.93 m2)

1412.2

What is the Tabular allowable area factor in square feet for a building classified as Group S-1, two or more stories above grade plane (SM) of Type IIIB construction?

52,500

Table 506.2

According to Table 1609.2 for windborne debris protection, what is the maximum fastener spacing required for a No. 10 wood-screw-based anchor used on a panel span between 4 feet and 6 feet?

12 inches

1609.2

Fire-retardant-treated wood exposed to weather, damp, or wet locations must be identified as “Exterior” to indicate there is no increase in the listed flame spread index when subjected to which test standard?

ASTM D2898

2303.2.7

Where required, the emergency power system for illumination shall provide power for a duration of not less than:

90 minutes

1008.3.1

For a 10-foot container with a nominal height of 8.0 feet (Container Designation 1D), what is the Allowable Shear Value (PLF) for the side wall for wind or seismic loading?

337 PLF.

Table 3114.8.5.3

Structural capacities and design provisions for prefabricated wood I-joists must be established and monitored in accordance with which standard?

ASTM D5055

2303.1.2

For smoke-protected assembly seating, the total exit access travel distance shall be not greater than 400 feet (122 m), and the portion of travel from each seat to the nearest entrance to a vomitory or concourse shall not exceed:

200 feet (60 960 mm)

Table 1030.6.2

Nondestructive testing of structural steel in the seismic force-resisting systems in structures assigned to Seismic Design Category B, C, D, E or F must be performed in accordance with the quality assurance requirements of:

AISC 341.

1705.14.1.1

What is the minimum thickness required for gypsum board used as a thermal barrier for mass timber elements serving as occupancy fire barriers in Type IV-B or IV-C construction?

5/8 inch (15.9 mm)

508.4.4.1

Which of the following load combinations for sloped glass includes the smallest factor applied to the inward wind force (Wi)?

Fg = 0.3Wi + D + 0.7S

2404.2

An accessible route shall be provided to at least 5 percent, but not less than one, of each type of:

bowling lane

1111.4.3

The route to the required public toilet facilities shall not pass through which three specific types of rooms?

Kitchens, storage rooms or closets

2902.3.1

Where one or more sides of any pane of glass are not firmly supported, or are subjected to unusual load conditions, detailed construction documents, detailed shop drawings and analysis or test data must be prepared by a:

registered design professional.

2403.2

For allowable stress design of masonry, the design must comply with Section 2106 and the requirements of Chapters 1 through 8 of TMS 402, except as modified by Sections 2107.2 through:

2107.3

2107.1

What percentage chance of being equaled or exceeded in any given year defines the Base Flood?

1-percent

202 [BS] Base Flood

Which ASTM standard applies to adhesives used for fastening gypsum board to wood framing?

ASTM C557

Table 2506.2

Glass and glazing used in greenhouses shall comply with which section?

Section 2405.

3112.4

Sloped glass is defined as glass sloped more than what minimum degree from vertical in applications like skylights and sloped roofs?

15 degrees (0.26 rad)

2404.2

For unstabilized adobe walls finished with unstabilized clay plaster, what installation component is explicitly stated as not being required?

lathing

2109.2.4.8.9.5

The perimeter of a raised-deck system installed above a roof assembly shall be surrounded on all sides by walls or by a noncombustible enclosure approved to prevent fire intrusion and which shall extend at least from the roof assembly to the:

top surface of the raised-deck system

1511.9.1 Item 1

Electrical vehicle charging stations provided to serve Group R-3 and R-4 occupancies are:

not required to comply with Section 1107.2

1107.2 Exception 1

Buildings and other structures that represent a low hazard to human life in the event of failure, such as agricultural facilities or minor storage facilities, are assigned to which risk category?

Risk Category I

1604.5

Where cladding is attached directly over foam sheathing to 43 mil cold-formed steel framing using a #10 screw, with a cladding weight of 25 psf and a fastener vertical spacing of 8 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.2.1 (assuming 24 inches on center horizontal spacing)?

1.8

1404.5.2.1

In areas likely to have expansive soil, the building official must require soil tests where such soils exist, and soils must be considered expansive if the expansion index determined in accordance with ASTM D4829 is greater than:

20

1803.5.3

The required fire-resistance rating in hours for a fire barrier separating a single occupancy into fire areas for Group F-1, H-3, or S-1 is:

3 hours

Table 707.3.10

Fully tempered glass glazed between intervening floors at a slope of 30 degrees (0.52 rad) or less from vertical does not require screening if the highest point of the glass is what maximum height above the walking surface?

10 feet (3048 mm).

2405.3.3

The occupant evacuation elevator lobby floor area must accommodate at least one wheelchair space of 30 inches by 52 inches (760 mm by 1320 mm) for each portion of the occupant load served?

50 persons

3008.6.4

Joints and voids that create concealed spaces between connected or stacked intermodal shipping containers at fire-resistance-rated assemblies must be protected by what approved system?

An approved fire-resistant joint system in accordance with Section 715.

3114.7

Walls less than what maximum length constructed of adobe units are considered isolated piers or columns and cannot be used in a load-bearing capacity?

24 inches (610 mm)

2109.2.4.7

Where minimum 1x wood furring is used to attach cladding over foam sheathing to a minimum 2x wood stud using a No. 10 wood screw, with a cladding weight of 11 psf and a fastener spacing in the furring of 16 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.2 (assuming 16 inches on center furring)?

1.65

1404.5.3.2

What is the maximum number of seats permitted per row with backrests served by an aisle or doorway at both ends where the assembly seating contains less than 4,000 total seats?

14

Table 1030.13.2.1

When building construction exceeds 40 feet in height above the lowest level of fire department vehicle access, where must a temporary or permanent stairway be provided?

Where building construction exceeds 40 feet (12 192 mm) in height

3310.1

Residential Group R-4 occupancy is defined as housing more than five but not more than how many persons, excluding staff, receiving custodial care on a 24-hour basis?

16

310.5

What is the maximum percentage of maximum allowable quantities of hazardous materials permitted per control area on the third story above grade plane?

50

Table 414.2.2

If a fire assembly serves multiple purposes in a building, it must comply with:

All requirements applicable to each individual fire assembly

702.1

When the building official grants modifications due to practical difficulties, the modification must not lessen structural requirements, life and fire safety, health, or:

Accessibility

104.2.4

An application for a permit is deemed abandoned how many days after the date of filing, unless pursued in good faith or a permit has been issued?

180 days

105.3.2

For smoke-protected assembly seating with 25,000 or more seats, what is the required capacity in inches per seat served for stepped aisles without handrails within 30 inches?

0.075

Table 1030.6.2

The lateral bearing pressures specified in Table 1806.2 shall be permitted to be increased by the tabular value for each additional foot of depth up to a value that is not greater than what factor multiplied by the tabular value?

15 times

1806.3.3

The fireplace throat or damper must be located not less than what minimum distance above the top of the fireplace opening?

8 inches (203 mm)

2111.8

For discontinuous mid-aisle handrails in stepped aisles serving seating on both sides, gaps or breaks must be provided at intervals not exceeding how many rows?

five rows

1030.16.1

Latex-modified Portland cement thin-set mortars used for ceramic tile installation must comply with which ANSI standard?

ANSI A118.4

2103.2.3.2

Structural concrete must conform to the durability requirements of ACI 318, except for concrete in basement walls of Group R-2 and R-3 occupancies not more than three stories above grade plane, where the specified compressive strength, must be not less than:

3,000 psi (20.7 MPa)

1904.1 Exception

What is the minimum required critical radiant flux in watts per square centimeter for exposed insulation materials installed on attic floors?

0.12

720.3.1

For slab-on-ground foundations on expansive soils, it is permitted to analyze and design such slabs by methods that account for soil-structure interaction, provided such alternative methods are rational and the basis for all aspects and parameters of the method shall be available for:

peer review

1808.6.2

Where more than one exit is required from a mall, the width of an exit passageway or corridor from the mall shall be not less than:

66 inches (1676 mm)

402.8.6

Nosings shall have a curvature or bevel of not less than 1/16 inch (1.6 mm) but not more than what maximum distance from the foremost projection of the tread?

9/16 inch (14.3 mm)

1011.5.5

Glazing in an individual fixed or operable panel is considered a hazardous location (Section 2406.4.3) if the bottom edge is less than 18 inches (457 mm) above the floor and the top edge is greater than:

36 inches (914 mm).

2406.4.3

Exposure D shall apply where Surface Roughness D prevails in the upwind direction for a distance of not less than 5,000 feet or:

20 times the height of the building, whichever is greater

1609.4.3

For prescriptive concrete foundation walls, the specified compressive strength, f’c, shall be not less than:

2,500 psi (17.2 MPa)

1807.1.6.2 Item 6

What must the fire service access elevator symbol (Figure 3007.6.5) contrast with, and what must the vertical center line be centered on?

The background; the hoistway door frame

3007.6.5

What is the maximum slope permitted for ramped aisles that are not required to be an accessible route?

1 unit vertical in 8 units horizontal (12.5-percent slope)

1030.14.1

The building official is authorized to serve a notice of violation on the person responsible for work in conflict with the code or in violation of a permit or certificate issued, and such order shall direct the discontinuance of the illegal action and the:

Abatement of the violation

114.2

Fire-retardant-treated wood structural panels must be dried to a moisture content of what maximum percentage before use?

15 percent

2303.2.9

If a smoke-protective curtain assembly for hoistways is used for elevator hoistway door protection, which UL standard must the control unit be listed to?

UL 864

3006.3

For stadiums and arenas with fixed seats, the design shall include horizontal swaying forces of 24 pounds per linear foot of seat applied in which direction?

parallel to each row

1607.18.1

Metal edge systems, except gutters and counterflashing, installed on low-slope built-up, modified bitumen, and single-ply roof systems shall be tested for resistance in accordance with Test Methods RE-1, RE-2 and RE-3 of:

ANSI/SPRI ES-1

1504.6

Plastering gypsum plaster or cement plaster shall be not less than three coats where applied over metal lath or wire fabric lath, and not less than how many coats where applied over other permitted bases?

two coats

2511.1

An assistive listening system is not required where there is no audio amplification system, EXCEPT in which location?

courtrooms

1109.2.7 Exception

Fiber-cement siding attached to wood studs must have nails long enough to penetrate the studs not less than:

1 inch (25 mm)

1404.17

Masonry fireplaces and foundations must be anchored at each floor, ceiling, or roof line more than 6 feet (1829 mm) above grade with how many 3/16-inch by 1-inch (4.8 mm by 25 mm) straps?

two

2111.5

Vehicle barriers in a public parking garage shall be not less than what height?

2 feet 9 inches (835 mm)

406.4.2

What international symbol must identify the elevator car provided for fire department emergency access?

The international symbol for emergency medical services (star of life)

3002.4

For Type H-5 fabrication areas, the minimum fire protection rating required for self-closing fire door assemblies separating the fabrication area from corridors is:

3/4 hour

415.11.1.2 Exception 1

The F Rating of a through-penetration firestop system or perimeter fire containment system limits the spread of fire through the penetration or void in terms of:

Time period

202 [BF] F Rating

What is the Tabular allowable area factor in square feet for a building classified as Group M, two or more stories above grade plane (SM) of Type IIA construction?

64,500

Table 506.2

Gutters that are used to secure the perimeter edge of the roof membrane on low-slope built-up, modified bitumen, and single-ply roofs must be tested in accordance with Test Methods G-1 and G-2 of which standard?

SPRI GT-1

1504.6.1

Where spaced sheathing is used for wood shingles, sheathing boards shall be not less than 1-inch by 4-inch nominal dimensions and shall be spaced on centers equal to the weather exposure to coincide with the placement of:

wood structural panels

1507.8.1

Broken glass retention screens, where required for sloped glazing, shall be capable of supporting what minimum factor multiplied by the weight of the glazing?

Twice the weight of the glazing.

2405.3

Reflective plastic core insulation shall have a flame spread index of not more than 25 and a smoke-developed index of not more than 450 when tested in accordance with ASTM E84 or UL 723, and test specimen preparation and mounting must be in accordance with which ASTM standard?

ASTM E2599

2614.3

Where rooms without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall have an area of not less than 8 percent of the interior room floor area, but not less than how many square feet?

25 square feet (2.3 m2)

1202.5.1.1

Required critical circuits must be protected by electrical circuit protective systems or construction having a minimum fire-resistance rating of not less than how long?

1 hour

2702.3

According to Table 1705.2.6, what type of special inspection is required for the installation of X-bracing, tightened to remove any sag?

Periodic special inspection.

Table 1705.2.6 Item 4

Fire-retardant-treated wood is NOT permitted in roof construction in buildings of Type IA construction exceeding two stories above grade plane where the vertical distance from the upper floor to the roof is less than:

20 feet (6096 mm)

603.1 Exception

A geotechnical investigation is required to determine if groundwater is above or within what maximum distance below the elevation of the lowest floor level, where such floor is located below the finished ground level adjacent to the foundation?

5 feet (1524 mm)

1803.5.4 Item 1

Special inspections and tests of masonry construction shall be performed in accordance with the quality assurance program requirements of which standards?

TMS 402 and TMS 602.

1705.4

For floor areas, the uniformly distributed, concentrated, and impact live load used in the design must be indicated, along with whether live load reduction in accordance with Section 1607.13 is used for:

each type of live load

1603.1.1

According to Table 1611.1, what is the minimum design storm return period required for Risk Category IV buildings?

500 years

1611.1

What is the Tabular allowable area factor in square feet for a nonsprinklered (NS) building classified as Group H-4 of Type IVC construction?

40,500

Table 506.2

What is the ground snow load reduction factor for a public-occupancy temporary structure in Risk Category III with a service life of 10 years?

0.8.

Table 3103.6.1.1

What minimum horizontal distance must intermodal shipping containers housing or supporting experimental equipment be located from adjacent structures?

A minimum of 8 feet (2438 mm).

3114.1 Exception 4.2

Where occupants egress from one room through others, capacity design shall be based on the cumulative portion of occupant loads of all rooms, areas or spaces to that point along which area?

The path of egress travel

1004.2.1

For Group R occupancies, what is the required separation for a hydrogen fuel gas room not classified as Group H?

2 hours

Table 509.1

Wood structural panels used for opening protection in R-3 or R-4 occupancies shall have a minimum thickness of:

7/16 inch (11.1 mm)

1609.2 Exception 1

In a high-rise building where stairway doors are locked, a telephone or other two-way communication system connected to an approved constantly attended station shall be provided at not less than every:

Fifth floor

403.5.3.1

Fire-resistance-rated assemblies tested under ASTM E119 or UL 263 shall not be considered restrained unless evidence satisfactory to the building official is furnished showing that the construction qualifies for a restrained classification in accordance with:

ASTM E119 or UL 263

703.2.1.3

Where Cross-Laminated Timber (CLT) is used in Type IV-HT exterior wall assemblies (2-hour rating or less), the exterior surface of the CLT must be protected by which of the following materials?

Gypsum board not less than 1/2 inch thick

602.4.4.2

The concentrated load indicated in Table 1607.1 for stair treads shall be applied on an area of:

2 inches by 2 inches (51 mm by 51 mm)

1607.2

A thermal barrier is not required for a high-pressure decorative exterior-grade compact laminate (HPL) system where the system is specifically approved based on tests conducted in accordance with NFPA 286, UL 1040 or:

UL 1715

1408.10.3

A proscenium wall with a minimum 2-hour fire-resistance rating is required where the stage height is greater than:

50 feet (15 240 mm)

410.2.4

Existing footings or foundations that can be affected by any excavation shall be underpinned adequately or otherwise protected against settlement and what other type of movement?

Lateral movement

3304.1.2

For buildings below slopes steeper than one unit vertical in one unit horizontal (100-percent slope), the toe of the slope shall be assumed to be at the intersection of a horizontal plane drawn from the top of the foundation and a plane drawn tangent to the slope at an angle of:

45 degrees (0.79 rad)

1808.7.1

Buildings containing corrosives, highly toxic materials, or toxic materials that are health hazards shall be classified as which High-Hazard Group?

Group H-4

307.6

The provisions of Section 3103 apply to structures erected for a period of less than how many days?

Less than 180 days.

3103.1

For horizontal building separation allowance, what type of construction must the building below the horizontal assembly be?

Type IA

510.2

The minimum vertical distance from top to top of two successive tiers of beams or finished floor surfaces used to measure a Story is defined as:

The vertical distance from top to top

202 [BG] Story

At least one accessible route shall connect accessible buildings, facilities, elements and spaces that are:

on the same site

1104.2

In Group R-2, R-3, and R-4 occupancies required to have Accessible, Type A, or Type B dwelling units, at least what percentage, but not less than one, of each type of parking space provided shall be accessible?

2 percent

1106.3 Item 1

What is the minimum thickness required for vertically erected studless solid plaster partitions made of 3/8-inch or 3/4-inch rib metal lath, 1/2-inch gypsum lath, or gypsum panel product?

2 inches (51 mm)

2504.1.2

Prior to the start of construction, the approved agencies must provide written documentation to the building official demonstrating the competence and relevant experience or training of the:

special inspectors.

1704.2.1

Grout used in masonry must comply with Article 2.2 of which standard?

TMS 602

2103.3

Openings in the fire barrier separating an interior exit stairway or ramp from an exit passageway are prohibited, EXCEPT for the fire door assembly required to provide a means of egress from the interior exit stairway and ramp to the:

exit passageway

1023.3.1

Where an exterior wall is not required to be fire-resistance rated based on fire separation distance, an exterior wall parapet is:

Not required

705.12 Exception 1

Structural concrete reinforced with Glass Fiber Reinforced Polymer (GFRP) reinforcement is permitted only where fire-resistance ratings are:

not required

1901.2.1

Handrails are permitted to protrude not more than what distance from the wall or guard into the circulation path?

4 1/2 inches (114 mm)

1003.3.3 Exception

Where a cold-formed steel truss clear span is 60 feet or greater, the special inspector must verify that the temporary installation restraint/bracing and permanent individual truss member restraint/bracing are installed in accordance with the:

approved truss submittal package.

1705.2.5

What two essential fire alarm system components must be monitored by the building’s fire alarm system for an automatic sprinkler system serving occupant evacuation elevators?

A sprinkler control valve supervisory switch and a water-flow-initiating device provided for each floor

3008.2.2

In Anchorage/Eagle River, Alaska, at an elevation of 500 feet, what is the ground snow load in pounds per square foot required for a Risk Category II building, according to Table 1608.2?

80 psf

1608.2

During the demolition of a building with an existing standpipe, how far below the floor being demolished shall the standpipe not be demolished?

Not more than one floor below

3311.2

The registered design professional must have a fully qualified representative on site during all:

boring or sampling operations.

1803.4

The ultimate axial load capacity of a test element, as determined by a registered design professional, must be used to set the resulting allowable load, which shall not be more than what maximum fraction of the ultimate capacity?

one-half

1810.3.3.1.2

An Institutional Group I-2 facility (Condition 1) provides nursing and medical care but does not provide which of the following services?

Emergency care, surgery, obstetrics, or in-patient stabilization units

308.3.1.1

A radiant barrier installed above a deck shall be permitted for use where the system consisting of the radiant barrier and the roof covering complies with the requirements of UL 1256 or:

FM 4450

1510.2

The design and installation of steel connections must be in accordance with the applicable referenced standards within this chapter, and for special inspection of welding or installation of high-strength bolts, which section applies?

Section 1705.2

2201.4

Any full-height wall length, or portion thereof, less than what minimum length shall not be considered as a portion of the lateral force-resisting system under the Simplified Structural Design Procedure?

4 feet (1219 mm).

3114.8.5.3

Awnings, canopies, marquees and signs with less than 15 feet (4572 mm) of clearance above the sidewalk shall not extend into or occupy more than what fraction of the width of the sidewalk measured from the building?

Not more than two-thirds the width.

3202.3.1

For prescriptive concrete foundation walls, vertical reinforcement with a minimum yield strength of 40,000 psi is permitted, provided that the same size bar is used and the spacing shown in Table 1807.1.6.2 is reduced by multiplying the spacing by:

0.67

1807.1.6.2 Item 2

If light-transmitting plastic interior signs exceed the aggregate area limit of 24 square feet, they must be separated from each other by not less than what minimum horizontal distance?

4 feet (1219 mm)

2611.3

Where the footboards or walking surface of seating facilities are more than 30 inches (762 mm) above the floor or grade below, perimeter guards are required. Where seatboards are adjacent to the perimeter, the minimum guard height shall be:

42 inches (1067 mm)

1030.17.1

Where the design wind pressure is 30 pounds per square foot or less, hardboard soffit panels are permitted to be attached to wood framing with siding nails spaced not more than 6 inches on center at panel edges and not more than what maximum distance on center at intermediate supports?

12 inches (305 mm)

1412.5

In an efficiency dwelling unit (other than Accessible, Type A, or Type B units), the kitchen sink, cooking appliance and refrigerator must each have a clear working space of not less than what minimum distance in front?

30 inches (762 mm)

1208.5 Item 3

Where through penetrations in a horizontal assembly are protected by a through-penetration firestop system, the system must have an F rating / T rating of not less than:

1 hour but not less than the required rating of the floor penetrated

714.5.1.2

Material other than foam plastic used as interior trim must have a minimum Class C flame spread and smoke-developed index when tested in accordance with:

ASTM E84 or UL 723

806.6

Which alternative allowable stress load combination is represented by D + L + 0.6W?

Equation 16-2

1605.2

What is the maximum aggregate area of all light-transmitting plastics permitted for interior signs?

24 square feet (2.23 m2)

2611.2

According to Table 722.7.1(2), what is the protection contribution time in minutes provided by 5/8-inch Type X gypsum board used as noncombustible protection for mass timber?

40 minutes

Table 722.7.1(2)

Flue lining systems for residential-type appliances are permitted to comply with clay flue lining requirements, listed chimney lining systems complying with UL 1777, or:

Type B gas vents

2113.11.1

Where an elevation change of 30 inches (762 mm) or less occurs between a cross aisle and the adjacent floor or grade below, guards not less than what distance above the aisle floor shall be provided?

26 inches (660 mm)

1030.17.2

What must cause each fire door assembly in the occupant evacuation elevator lobby smoke barrier to automatically close?

Receipt of any fire alarm signal from the emergency voice/alarm communication system serving the building

3008.6.3.2

According to Table 2406.2(2), for glazed panels regulated by Section 2406.4.2 (glazing adjacent to doors) with an exposed surface area of 9 square feet or less, what is the minimum ANSI Z97.1 Category class required?

Class B

2406.2

Buildings containing Group I-2 occupancies (Hospitals, etc.) are assigned to which risk category?

Risk Category IV

1604.5

For flammable gases in Group H-5 occupancies, the gas detection monitoring threshold level shall be vapor concentrations in excess of what percentage of the lower flammable limit (LFL)?

25 percent

415.11.8.2

Openings in a spark arrestor screen shall not permit the passage of spheres having a diameter greater than 1/2 inch (12.7 mm) nor block the passage of spheres having a diameter less than:

3/8 inch (9.5 mm)

2113.9.2 Item 3

The fireblocking of spaces between wood joists, beams, or headers in fireplaces must be to a depth of 1 inch (25 mm) and placed only on strips of metal or metal lath laid across the spaces between combustible material and the:

chimney

2111.13

Special inspections of welding and qualifications of special inspectors for reinforcing bars must be in accordance with the requirements of AWS D1.4 for special inspection and for:

special inspector qualification.

1705.3.1

An automatic sprinkler system is required throughout a Group F-1 fire area used for the manufacture of upholstered furniture or mattresses that exceeds:

2,500 square feet (232 m2)

903.2.4.3

What is the maximum Frontage Increase Factor when a building that does not meet Section 507 requirements has 80 percent of its perimeter on an open space of 35 feet?

0.75

Table 506.3.3

Who must the owner designate to ensure compliance with the site safety plan and enforce its provisions?

A person to be the site safety director

3302.2

Metal roof shingles applied to a solid or closely fitted deck shall be tested in accordance with ASTM D3161, FM 4474, UL 580 or:

UL 1897

1504.4.3

A Class II interior floor finish material must have a minimum critical radiant flux of:

0.22 watts/cm2 or greater

804.2

Interior wall and ceiling finishes within the mall of a covered mall building shall have a minimum flame spread index and smoke-developed index of:

Class B

402.6.1

Masonry chimneys shall not be corbeled more than what maximum fraction of the chimney’s wall thickness from a wall or foundation?

half

2113.5

For a motion picture projection room used for a single machine, the minimum required floor area is:

80 square feet (7.44 m2)

409.2

A radiant barrier installed above a deck shall comply with which ASTM standard?

ASTM C1313/C1313M

1510.4

For natural ventilation purposes in an open parking garage, the area of openings in exterior walls on a tier shall be not less than what percentage of the total perimeter wall area of each tier?

20 percent

406.5.2

Insulated Vinyl Siding must have a thermal resistance of the cladding product not less than:

R-2

202 [BF] Insulated Vinyl Siding

Base flashing for asphalt shingles shall be of corrosion-resistant metal of minimum nominal 0.019-inch thickness or mineral-surfaced roll roofing weighing not less than what minimum weight per 100 square feet?

77 pounds

1507.2.8.1

An interior wall or ceiling finish material that is not more than 1/4 inch (6.4 mm) thick must be applied directly onto the wall, ceiling, or structural element without the use of furring strips and shall not be:

Suspended away from the building element

803.15.4

For every six or fraction of six accessible parking spaces, at least how many shall be a van-accessible parking space?

at least one

1106.6

Where only one accessible route is provided, it shall not pass through:

kitchens, storage rooms, restrooms, closets or similar spaces

1104.5 Item 3

An Institutional Group I-3 facility (Condition 1) is characterized by allowing free movement to the exterior via means of egress without:

Restraint

308.4.1

Special inspection of minimum clearances in plumbing, mechanical and electrical components is not required where which component is used in sprinkler systems?

Flexible sprinkler hose fittings.

1705.13.6 Exception

Turnstiles serving an occupant load greater than 300 that are not portable shall have a side-hinged swinging door that conforms to Section 1010.1 within what maximum distance?

50 feet (15 240 mm)

1010.5.4

The net free area under a masonry or metal rain cap installed on a masonry chimney shall be not less than what minimum multiple of the net free area of the chimney flue outlet it serves?

four times

2113.9.3

Submittal documents, including construction documents, geotechnical report, and statement of special inspections, must be submitted in a minimum of how many sets (unless digital format is allowed)?

Two or more sets

107.1

In boxes other than luxury boxes, club boxes and suites, wheelchair spaces shall be located in not less than what percentage of all boxes provided?

20 percent

1109.2.2.3

Buildings for more than 16 persons, excluding staff, who reside on a 24-hour basis in a supervised environment and receive custodial care (such as assisted living facilities), are classified as which Institutional Group?

Group I-1

308.2

Where a technical opinion and report is required by the building official to determine compliance, who must provide the report without charge to the jurisdiction?

The owner or owner's authorized agent

104.2.2.1

What must dwelling units complying with the air leakage requirements of the International Energy Conservation Code or ASHRAE 90.1 be ventilated by?

Mechanical means

1202.1

According to Table 1507.3.7 for General Clay or Concrete Roof Tile on a roof slope of 3:12 and over, what is the attachment requirement for a maximum Allowable Stress Design Wind Speed (Vasd) of 85 mph and a mean roof height of 0–60 feet?

Two fasteners per tile

1507.3.7

The structural observer must visually observe representative locations of structural systems, details and load paths for general conformance to the:

approved construction documents.

1704.6

The thickness of foam plastic signs used in a mall shall not be greater than:

1/2 inch (12.7 mm)

402.6.4.5.2

According to Table 1507.3.7 for Interlocking Clay or Concrete Roof Tile (with anchor lugs, solid sheathing without battens) on all roof slopes, what is the attachment requirement for a maximum Allowable Stress Design Wind Speed (Vasd) of 85 mph and a mean roof height of 0–60 feet?

One fastener per tile.

1507.3.7

In nursing homes (I-2, Condition 1), water closets and roll-in-type showers required to comply with ICC A117.1 are permitted to be substituted with alternate compliance provisions in not more than what percentage of the Accessible units?

90 percent

1108.5.2.1 Exceptions

What is the required separation in hours between a sprinklered (S) Group H-5 occupancy and a sprinklered (S) Group F-1 occupancy?

1

Table 508.4

The special inspection of masonry must be as defined in Chapter 17, or an itemized testing and inspection program must be provided that meets or exceeds the requirements of:

Chapter 17

2101.3

Second-hand masonry units shall not be reused unless they conform to the requirements of new units and:

old mortar shall be cleaned from the unit before reuse

2103.1.1

The exterior air intake for masonry fireplaces must be covered with a corrosion-resistant screen of what maximum mesh size?

1/4-inch (6.4 mm) mesh

2111.14.3

According to Table 1504.2, for a maximum basic wind speed (V) of 142 mph, what is the required ASTM D7158 classification for steep slope roof shingles?

G or H

1504.2

Areas of refuge are generally required at stairways except when the building is equipped throughout with an automatic sprinkler system and/or which other occupancy group?

Group R-2

1009.3.3 Exceptions

In ambulatory care facilities, the required refuge area shall provide not less than what net square footage for each nonambulatory care recipient?

30 net square feet (2.8 m2)

422.3.2

In general-purpose hospitals, psychiatric facilities, and detoxification facilities (Group I-2), at least what percentage, but not less than one, of the dwelling units and sleeping units shall be Accessible units?

10 percent

1108.5.3.1

Chimneys must extend not less than 2 feet (610 mm) higher than any portion of the building within what maximum distance?

10 feet (3048 mm)

2113.9

Side-hinged swinging doors, pivoted doors, and balanced doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of how many or more persons?

50 persons

1010.1.2.1

Wood shingles shall be laid with a side lap of not less than 1.5 inches between joints in courses, and no two joints in any how many adjacent courses shall be in direct alignment?

three

1507.8

What is the Tabular allowable area factor in square feet for a building classified as Group I-2, one story above grade plane (S1) of Type VB construction?

NP

Table 506.2

A museum, library, or place of religious worship is generally classified as which Assembly Group?

Group A-3

303.4

A liquid-applied protective coating shall be applied to polyurethane foam roofs not less than 2 hours nor more than what maximum duration following the application of the foam?

72 hours

1507.13.3

The maximum number of residents permitted in any single smoke compartment in a Group I-3 occupancy is:

200

408.6.1

Site safety plans must include the name and contact information for which role?

Site safety director

3302.1.1

Are elevators permitted in a common shaft enclosure with a stairway?

No

3002.7

For a fire separation distance of 5 feet or greater, the minimum distance that an exterior wall projection must be kept from the line used to determine the FSD is:

40 inches

Table 705.2

The minimum clear width of a means of egress ramp between handrails or other permissible projections shall be:

36 inches (914 mm)

1012.5.1

In Group R-2, R-3, and R-4 occupancies where recreational facilities serve a single building containing Type A units or Type B units, what percentage, but not less than one, of each type of recreational facility shall be accessible?

25 percent

1111.2.2

For an open parking garage beneath Groups A, I, B, M and R, the height, in both feet and stories, of the portion of the building above the open parking garage shall be measured from grade plane and shall include:

Both the open parking garage and the portion of the building above the parking garage

510.7

Where a metal-plate-connected wood truss clear span is 60 feet or greater, the special inspector must verify that the temporary installation restraint/bracing and the permanent individual truss member restraint/bracing are installed in accordance with the:

approved truss submittal package.

1705.5.2

In assembly areas with a seating capacity of 1,001 to 2,000, the minimum number of receivers required to be hearing-aid compatible is what fraction of the total required receivers?

1 per 4 receivers

Table 1109.2.7.1

Walls and ceilings of spray rooms shall be constructed of noncombustible materials or the interior surface shall be completely covered with noncombustible materials, and what material is specifically prohibited from use?

Aluminum

416.2.1

Where a lining of firebrick not less than 2 inches (51 mm) thick is provided in a masonry firebox, the minimum thickness of back and sidewalls, including the lining, shall each be:

8 inches (203 mm) of solid masonry

2111.6

To qualify for an area factor increase based on frontage, a building shall have not less than what minimum percentage of its perimeter on a public way or open space?

25 percent

506.3.1

Signs identifying accessible toilet or bathing rooms where not all such rooms are accessible shall include the:

International Symbol of Accessibility

1112.1 Item 4

The primary purpose of these regulations is to establish minimum requirements to provide a reasonable level of safety, health and general welfare through all the following aspects EXCEPT:

Property valuation requirements

101.3

In dining and drinking areas, an accessible route to dining and drinking areas in a mezzanine is not required, provided that the mezzanine contains less than what percentage of the total combined area for dining and drinking and the same services are provided in the accessible area?

25 percent

1109.2.9 Exception 2

Combustible materials shall not be placed within 36 inches (914 mm) of the outside surface of a masonry heater in accordance with NFPA 211, Section:

12.6

2112.5

Combustible kiosks constructed of foam plastics located within a covered mall building shall have a maximum heat release rate not greater than:

100 kW (105 Btu/h)

402.6.2

Who is responsible for the development, implementation and maintenance of an approved, written site safety plan?

The owner or owner's authorized agent

3302.1

Inspections of penetration firestop systems tested and listed in accordance with Sections 714.4.1.2 and 714.5.1.2 must be conducted by an approved agency in accordance with:

ASTM E2174.

1705.18.1

Anchor rods must be set in accordance with the approved construction documents, and the protrusion of the threaded ends through the connected material shall fully engage the threads of the nuts, but shall not be greater than which length?

The length of the threaded portion of the bolts

2201.5

Where a Type III, IV or V building has a fire separation distance of 60 feet or greater from a property lot line, what minimum water supply shall be provided?

500 gallons per minute (1893 L/m)

3313.3.3

The deflection of framing members supporting glass, when subjected to 0.6 times the “component and cladding” wind loads, shall not exceed 1/175 of the length of span of the framing member if the length is not more than:

13 feet 6 inches (4115 mm)

1604.3.7

Insulated metal panels (IMP) with a combustible core must be separated from the interior of a building by an approved thermal barrier consisting of 1/2-inch gypsum wallboard or a material complying with the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of:

NFPA 275

1409.7.2

The use of clay plasters is prohibited on weather-exposed:

parapets

2109.2.4.8.9.3

The design, fabrication, and erection of structural steel elements and composite structural steel and concrete elements in buildings must be in accordance with which standard?

AISC 360

2202.1

The 60-foot (18 288 mm) public ways or yards required for unlimited area buildings shall be permitted to be reduced to not less than 40 feet (12 192 mm) provided the reduced width is not allowed for more than what percentage of the building’s perimeter?

75 percent

507.2.1

Surface-bonding mortar for concrete masonry units shall comply with which ASTM standard?

ASTM C946

2103.2.2

In high-rise buildings not classified as Group R-2 and more than 420 feet (128 m) in height, which of the following is prohibited from being considered the additional interior exit stairway required?

Scissor stairways

403.5.2

The required sample size for SFRM inspection shall not exceed what maximum percentage of that specified by the referenced standards in Sections 1705.15.4.1 through 1705.15.4.9?

110 percent.

1705.15

What is the minimum required length of a court unless bounded on one end by a public way or yard?

10 feet (3048 mm)

1205.3

A flight of stairs shall not have a vertical rise greater than what maximum distance between floor levels or landings?

12 feet (3658 mm)

1011.8

The load resistance of vertical glass under uniform load shall be determined in accordance with which ASTM standard?

ASTM E1300.

2404.1

According to Table 1705.6, what type of inspection is required during fill placement to verify densities and lift thicknesses during placement and compaction of compacted fill?

Continuous special inspection.

Table 1705.6 Item 4

For buildings of construction types other than Type VB, light-transmitting plastics shall not be installed more than what maximum height above grade level?

75 feet (22 860 mm)

2608.2

Rooftop mounted photovoltaic (PV) panel systems shall be tested, listed and identified with a fire classification in accordance with which UL standard?

UL 2703

1505.9

For horizontal building separation allowance, what is the maximum number of stories an enclosure above the horizontal assembly can connect while utilizing the exception for reduced rating (1-hour)?

Fewer than four

510.2 Exception

When combustible building materials are delivered to a site, what is the minimum required fire flow?

500 gallons per minute (1893 L/m)

3313.2

An automatic sprinkler system is required throughout a Group M fire area used for the display and sale of upholstered furniture or mattresses where the area exceeds:

5,000 square feet (464 m2)

903.2.7.2

What is the minimum required floor area for an enclosed fire service access elevator lobby, regardless of the number of elevators served?

150 square feet (14 m2)

3007.6.4

Exterior windows and sliding doors must be tested and labeled as conforming to which standard?

AAMA/WDMA/CSA101/I.S.2/A440.

1709.5.1

Where a structure is intended to have forklifts or other movable equipment, the vehicle and wheel loads shall be increased by what percentage to account for impact?

30 percent

1607.8.4.1

For Institutional occupancies classified as “Prisons,” what is the required ratio for showers?

1 per 15

Table 2902.1

Which item, in addition to reports of special inspections, must the owner or authorized agent submit to the building official?

Certificates of compliance for open web steel joists and joist girders.

1704.5 Item 5

In Group I-3 occupancies, at least what percentage of the total number of sleeping units in the facility, but not less than one unit in each classification level, shall be Accessible units?

3 percent

1108.5.5.1

After a structure has been demolished, how must the vacant lot be maintained?

Filled and maintained to the existing grade or in accordance with the ordinances of the jurisdiction

3303.4

For areas having fixed seating without dividing arms, the occupant load shall be based on one person for each what minimum length of seating?

18 inches (457 mm)

1004.6

What is the maximum number of dwelling units permitted on the second story above grade plane of a Group R-2 occupancy for a single exit to be permitted, provided the building is sprinklered?

4 dwelling units

Table 1006.3.3

In a self-service storage facility with 10 total spaces, what is the minimum number of required accessible self-storage spaces?

1

Table 1109.3

What defines an Exterior Wall in terms of slope with the horizontal plane?

60 degrees (1.05 rad) or greater

202 [BF] Exterior Wall

For ambulatory care facilities, an automatic sprinkler system is required throughout the entire floor where four or more care recipients are:

incapable of self-preservation

903.2.2.1

Curtains, draperies, fabric hangings and similar combustible decorative materials required to exhibit improved fire performance must meet the flame propagation performance criteria of Test 1 or 2 of NFPA 701, or exhibit a maximum heat release rate of:

100 kW

806.4

According to Table 1607.1, what is the minimum uniformly distributed live load required for sidewalks and yards subject to trucking?

250 psf

1607.1

A spiral stairway used for egress must have a minimum clear tread depth of 6 3/4 inches (171 mm) at a point 12 inches (305 mm) from the narrow edge, and the maximum riser height shall be:

9 1/2 inches (241 mm)

1011.1

Combustible trim, excluding handrails and guardrails, shall not exceed what maximum percentage of the specific wall or ceiling area to which it is attached?

10 percent

806.6

Periodic special inspection is required for the anchorage of electrical equipment for emergency and standby power systems in structures assigned to which Seismic Design Categories?

C, D, E or F.

1705.13.6 Item 1

The setback between pools regulated by this code and slopes shall be equal to what fraction of the building footing setback distance required by Section 1808.7?

one-half

1808.7.3

Swales used for diverting water away from the foundation must be sloped not less than 2 percent where located within what maximum distance of the building foundation?

10 feet (3048 mm)

1804.4

In stories containing Group A-1 occupancies, an automatic sprinkler system is required where the fire area exceeds 12,000 square feet (1115 m2), or the fire area has an occupant load of:

300 or more

903.2.1.1

Casinos (gaming areas) and nightclubs intended for food and/or drink consumption are classified under which Assembly Group?

Group A-2

303.3

What type of masonry units must be used for dry-stack masonry?

Concrete masonry units complying with ASTM C90

2114.3

Construction of dry-stack masonry must comply with which ASTM standard?

ASTM C946

2114.5

Vestibules and storm enclosures shall not encroach more than 3 feet (914 mm) nor more than what fraction of the width of the sidewalk beyond the street lot line?

Nor more than one-fourth of the width of the sidewalk.

3202.4

For air-supported and air-inflated structures required to have a support system in the event of deflation, what is the minimum height the support system must maintain the membrane above the floor, seating area, or surface of the water, for membranes other than those used as a roof for Type I construction?

Not less than 7 feet (2134 mm).

3102.8.3

The ground immediately adjacent to the foundation must be sloped away from the building at a slope of not less than 1 unit vertical in 20 units horizontal (5-percent slope) for a minimum distance of:

10 feet (3048 mm)

1804.4

Concrete and masonry chimneys for medium-heat appliances must extend not less than 10 feet (3048 mm) higher than any portion of any building within what maximum distance?

25 feet (7620 mm)

2113.11.2.4

What minimum period prior to the scheduled starting date of the excavation must the person making the excavation provide written notice to owners of adjacent property?

Not less than 10 days

3307.1

The minimum width for stairways serving an occupant load of less than 50 shall be not less than:

36 inches (914 mm)

1011.2 Exception 1

Any material, appliance, equipment, system or method of construction meeting the requirements of this code shall be approved in writing after satisfactory completion of required tests and submission of:

required test reports.

1703.2

Where storm shelters are located outside the building they serve, the distance of travel from the exterior door of the building to a door of the shelter shall not exceed:

1,000 feet (305 m)

423.4.2

Combustible material directly above and within 12 inches (305 mm) of the fireplace opening shall not project more than what maximum distance for each 1-inch (25 mm) distance from such opening?

1/8 inch (3.2 mm)

2111.12 Exception 4

For a building containing accessory occupancies, the allowable building height and number of stories shall be based on the limitations for which occupancy?

The main occupancy of the building

508.2.2

An enclosed parking garage accessory to a one- or two-family dwelling is exempt from which requirement?

Mechanical ventilation

406.6.2 Exception

Gypsum panel products and accessories must be stored to protect such materials from the:

weather

2506.1

An alternative material, design, or method of construction must be not less than the equivalent of that prescribed in this code with respect to effectiveness, durability, and safety. What other factor is listed as an equivalency criterion?

Quality

104.2.3.4

In assembly and mercantile occupancies, an accessible family or assisted-use toilet room shall be provided where an aggregate of how many or more male and female water closets is required?

six

1110.2.1

The firebox of a concrete or masonry fireplace shall have a minimum depth of:

20 inches (508 mm)

2111.7

An approved agency must disclose possible conflicts of interest to the building official and the registered design professional in responsible charge so that:

objectivity can be confirmed.

1703.1.1

For the purposes of this code, words stated in the masculine gender include the feminine and:

Neuter

201.2

According to Table 2114.4, what is the maximum allowable stress (psi) for flexural tension in the horizontal span of dry-stack masonry?

30

2114.4

According to Table 1508.2, which ASTM standard applies to High-density polyisocyanurate board used for roof insulation?

ASTM C1289, Type II, Class 4

1508.2

In standard roll-in-type shower compartments designed for assisted bathing, the clear inside dimension shall be not less than 60 inches (1525 mm) in width and what minimum depth?

30 inches (760 mm)

1110.2.3.1

What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group F-1 of Type IIA construction?

5

Table 504.4

The maximum allowable quantity of Class IA flammable liquid in wholesale and retail sales occupancies per control area in a nonsprinklered building is:

30 gallons

Table 414.2.5.2

What is the maximum distance columns or pilasters (including bases and moldings) are permitted to project into the public right-of-way below 8 feet in height?

Not project more than 12 inches (305 mm).

3202.2.2

Fire-retardant-treated wood roof coverings shall be tested in accordance with ASTM E108 or UL 790 and additionally in accordance with:

ASTM D2898

1505.1

A roof recover shall NOT be permitted where the existing roof has what maximum number of applications of any type of roof covering?

Two or more

1512.3 Exception 3

For exit access stairways and ramps in sprinklered buildings (Groups R-1, R-2, R-3) where the opening is protected by a draft curtain and closely spaced sprinklers, this provision is limited to openings that do not connect more than how many stories?

four

1019.3 Item 4

In Group I-2 occupancies, any change in elevation in portions of the means of egress that serve nonambulatory persons shall be by means of a ramp or sloped walkway, throughout which area?

A story

1003.5

Exterior openings into the attic space for ventilation must have a least dimension not less than 1/16 inch (1.6 mm) and not more than what maximum least dimension?

1/4 inch (6.4 mm)

1202.2.2

Where a lining of firebrick not less than 2 inches (51 mm) thick is provided in the smoke chamber walls, the total minimum thickness of front, back, and sidewalls shall be 6 inches (152 mm) of solid masonry, including the lining, and the firebrick must conform to ASTM C1261 and be laid with refractory mortar conforming to which ASTM standard?

ASTM C199

2111.9

Cross-laminated timbers must be manufactured and identified in accordance with which standard?

ANSI/APA PRG 320

2303.1.4

In buildings of Type I or II construction for special industrial occupancies, the aggregate area of mezzanines shall be not greater than what fraction of the floor area of the room?

Two-thirds

505.2.1 Exception 1

For horizontal building separation allowance, the horizontal assembly separating the buildings must have a fire-resistance rating of not less than:

3 hours

510.2

Textile wall coverings must comply with Section 803.1.1, 803.5.1, or 803.5.2, and must be tested in the manner intended for use, including:

The product-mounting system, including adhesive

803.5

Automatic sprinkler system riser rooms and fire pump rooms must be maintained at a temperature of not less than:

40°F (4°C)

902.1.3

Parapet walls required by Section 705.12 must be coped or covered with weatherproof materials of a width not less than the thickness of the parapet wall such that the wall’s fire-resistance rating is not:

decreased

1503.3.1

Where earthquake loads are included in the design of retaining walls, the minimum safety factor for sliding and overturning is permitted to be reduced to:

1.1

1807.2.3 Exception

The presumptive load-bearing capacity is permitted to be used where the building official deems the capacity is adequate for the support of lightweight or:

temporary structures

1806.2 Exception

What type of standby power must serve the fire service access elevator equipment, hoistway lighting, ventilation and cooling equipment, and car lighting?

Type 60/Class 2/Level 1

3007.8

In Group I-3, Condition 2, 3, or 4 occupancies, the dead end in a corridor shall not exceed what maximum length?

50 feet (15 240 mm)

1020.5 Exception 1

If end-jointed lumber is used in an assembly required to have a fire-resistance rating, what designation must be included in its grade mark?

"Heat Resistant Adhesive" or "HRA"

2303.1.1.2

The upward pressure of water on basement floors, slabs on ground, and foundations shall be taken as the full hydrostatic pressure applied over the entire area, with the hydrostatic load measured from the:

underside of the element being evaluated

1610.2

Where structural components of a prefabricated assembly are not visible for inspection, the owner or authorized agent must submit a report that must be approved by the:

building official.

1703.6

Dome-shaped light-transmitting plastic skylights must rise above the mounting flange a minimum distance equal to 10 percent of the maximum width of the dome but not less than:

3 inches (76 mm)

2610.3

The basic wind speed, for use in the design of Risk Category III buildings and structures shall be obtained from which figure?

Figure 1609.3(3)

1609.3

Intermodal shipping containers housing or supporting experimental equipment are exempt from the requirements of Section 3114, provided they are single stand-alone units supported at grade level and used only for occupancies under which Risk Category?

Risk Category I in Table 1604.5.

3114.1 Exception 4.1

The area of a Group F-2 or S-2 building of any construction type not more than one story above grade plane shall not be limited if surrounded by public ways or yards not less than what width?

60 feet (18 288 mm)

507.3

What is the minimum thickness required for particleboard floor underlayment conforming to Type PBU of ANSI A208.1?

1/4-inch (6.4 mm)

2303.1.8.1

In Group B and M occupancies, corridors in ambulatory care facilities shall be provided with interior wall and ceiling finish materials of which classification?

Class A or B

Table 803.13 Note m

Sleeping units and other habitable rooms of a dwelling unit shall have a net floor area of not less than:

70 square feet (6.5 m2)

1208.4

The capacity, in inches, of means of egress stairways shall be calculated by multiplying the occupant load served by a capacity factor of 0.3 inch (7.6 mm) per occupant, EXCEPT that in sprinklered buildings (other than Group H and I-2), the factor is reduced to:

0.2 inch (5.1 mm) per occupant

1005.3.1 Exception

In buildings of Type I or II construction, partitions dividing portions of stores occupied by one tenant only and that do not establish a corridor serving an occupant load of 30 or more are permitted to be constructed of wood panels or similar light construction up to what maximum height?

6 feet (1829 mm)

603.1

Design rainfall intensity (in/hr), and the locations of which roof drainage component must be shown on construction documents, regardless of whether rain loads govern the design?

Roof drain, scupper and overflow

1603.1.9

Projections into the clear opening width of a door between 34 inches (864 mm) and 80 inches (2032 mm) above the floor or ground shall not exceed:

4 inches (102 mm)

1010.1.1.1

Fasteners for clay or concrete tile shall be of sufficient length to penetrate the deck not less than 3/4 inch or through the thickness of the deck, whichever is:

less

1507.3.6

What is the maximum slope considered to be a Low-Slope roof?

2 units vertical in 12 units horizontal (17-percent slope)

202 [BS] Low-Slope

Where structural steel members require fire protection, any additional structural steel members having direct connection to the primary structural frame shall be protected with the same fire-resistive material and thickness for a distance of not less than:

12 inches (305 mm)

704.5.1

How shall waste materials be removed?

In a manner that prevents injury or damage to persons, adjacent properties and public rights-of-way

3301.5

Common use circulation paths within employee work areas shall be accessible routes, EXCEPT where the paths are located within work areas that are less than how many square feet (m2) in size and defined by permanently installed partitions, counters, casework or furnishings?

1,000 square feet (93 m2)

1104.3.1 Exception 1

On exterior stud walls, adhered masonry veneer shall be installed not less than 4 inches above the earth, or not less than 2 inches above paved areas, or not less than what minimum distance above exterior walking surfaces that are supported by the same foundation?

1/2 inch (12.7 mm)

1404.11.1.3

A fire-resistant pipe-protection system used for generator fuel lines in a high-rise building must have a minimum fire-resistance rating of not less than 2 hours, unless the building is protected throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1, in which case the required rating is reduced to what minimum duration?

1 hour

2702.1.2

What is the allowable number of stories above grade plane for a nonsprinklered (NS) building classified as Group A-5 of Type IIA construction?

UL

Table 504.4

In a self-service storage facility with 300 total spaces, what is the minimum number of required accessible self-storage spaces?

12

Table 1109.3

Where elevators are provided in buildings four or more stories above or four or more stories below grade plane, what is the minimum size of the ambulance stretcher that at least one elevator car must be able to accommodate?

24 inches by 84 inches (610 mm by 2134 mm)

3002.4

What type of latching hardware is required on corridor doors in Group I-2 occupancies that are not required to have a fire protection rating?

Positive latching

407.3.1

Letters on externally illuminated exit signs shall be not less than 6 inches (152 mm) high with the principal strokes of the letters not less than what minimum width?

3/4 inch (19.1 mm)

1013.6.1

What is the minimum required fire-resistance rating in hours for a fire wall separating Group A, B, E, H-4, I, R-1, R-2, or U occupancies?

3 hours

Table 706.4

For masonry foundation walls, alternative reinforcing bar sizes are permitted, provided the spacing of reinforcement does not exceed:

72 inches (1829 mm)

1807.1.6.3.1

Uplift connection requirements listed in Table 2308.11.4 for the corner of the building are permitted to be reduced for connections located 20 percent or more of the least horizontal dimension from the corner by multiplying the table value by what factor?

0.75

2308.11.4

According to Table 1705.8, inspecting drilling operations and maintaining complete and accurate records for each cast-in-place deep foundation element requires which type of inspection?

Continuous special inspection.

Table 1705.8 Item 1

A Water-Reactive Material Class 3 reacts explosively with water without requiring:

Heat or confinement

202 [F] Class 3

The quality assurance program for masonry construction must comply with the inspection and testing requirements of Chapter 17 and which standard?

TMS 602

2105.1

For Group H occupancies, the supervision and monitoring of emergency alarm, detection and automatic fire-extinguishing systems shall be in accordance with the:

International Fire Code

901.6.3

Periodic special inspection for architectural components is not required for interior nonbearing walls weighing what maximum weight?

15 psf (0.72 kN/m2) or less.

1705.13.5 Exception 3

For structures assigned to Seismic Design Category D, E or F, the geotechnical investigation must include the determination of dynamic seismic lateral earth pressures on foundation walls and retaining walls supporting more than what minimum height of backfill due to design earthquake ground motions?

6 feet (1.83 m)

1803.5.12 Item 1

The egress analysis for full-building occupant evacuation must demonstrate that the number of evacuation elevators results in an evacuation time less than what maximum duration?

1 hour

3008.1.1

Retaining walls are exempt from a building permit requirement, provided the height measured from the bottom of the footing to the top of the wall is not over:

4 feet (1219 mm)

105.2

According to Table 2609.4, what is the maximum area of an individual roof panel (in square feet) permitted for Class CC2 plastic?

100

Table 2609.4

Clay and concrete roof tile shall be installed on roof slopes of what minimum units vertical in 12 units horizontal?

2 1/2 units

1507.3.2

For exterior walls of one-story buildings constructed of insulated metal panels (IMP) with foam plastic insulation cores, a thermal barrier is not required if the building is equipped throughout with an automatic sprinkler system and the foam plastic core thickness is not more than:

4 inches (102 mm)

2603.4.1.4

What minimum fire protection rating is required for each doorway in the smoke barrier separating the occupant evacuation elevator lobby?

3/4-hour

3008.6.3

For Group M and S occupancies, the maximum allowable quantity of low burning velocity Category 1B flammable gas (gaseous) in a sprinklered control area is:

390,000 cu ft

Table 414.2.5.4

Approval of a fabricator to perform work without special inspection must be based on review of the fabricator’s written fabrication procedures and quality control manuals, with periodic auditing by an approved agency or the:

building official.

1704.2.5.1

Footings for masonry fireplaces and their chimneys must be constructed of concrete or solid masonry not less than how thick?

12 inches (305 mm)

2111.3

Special inspections and tests are not required for masonry fireplaces installed or constructed in accordance with which section?

Section 2111.

1705.4 Exception 3

Drinking fountains shall not be required for an occupant load of what maximum number?

15 or fewer

2902.6

It shall be the duty of the owner or the owner’s authorized agent to cause the work to remain visible and able to be accessed for inspection purposes until:

Approved

110.1

In determining the fire-resistance rating of a shaft enclosure, the number of stories connected shall include any basements but not any:

Mezzanines

713.4

When firefighters’ emergency operation is active, what is the minimum required illumination level for the entire height of the fire service access elevator hoistway?

1 footcandle (11 lux)

3007.5.2

Masonry heaters must comply with the requirements of ASTM E1602 or be listed and labeled in accordance with UL 1482 or:

EN 15250

2112.2

For exterior walls of buildings of any height, foam plastic insulation tested separately must have a flame spread index of 25 or less and a smoke-developed index of 450 or less, in a thickness not to exceed:

4 inches (102 mm)

2603.5.4

Where the building official issues a stop work order, who must the written order be given to?

The owner of the property, the owner's authorized agent, or the person performing the work

115.2

For cold-formed steel light-frame construction in high wind areas, periodic special inspection is required for welding operations of elements of the:

main windforce-resisting system.

1705.12.2

According to Table 1507.1.1(1), for Metal roof shingles installed in an area with a maximum basic wind speed (V) of 130 mph (Hurricane-Prone Regions), which underlayment type is required?

ASTM D226 Type II

1507.1.1

Mortar for adobe units must be in accordance with Section 2103.2.1, or be composed of adobe soil of the same composition and stabilization as the:

adobe brick units

2109.2.4.2.1

Bulk shipments of roof-covering materials must be accompanied with the same product information issued in the form of a certificate or on a:

bill of lading

1506.3

Information required to be permanently identified on the product, material or assembly must be of a type that, once applied, cannot be removed without being:

destroyed.

1703.5.4

What is the minimum required fire-resistance rating for an exterior wall of a nonsprinklered Group A, B, E, F-2, I, R, S-2, or U occupancy where the fire separation distance is 10 feet or greater and less than 30 feet, and the construction type is IA, IB, IVA, or IVB?

1 hour

Table 705.5 Note c

According to Table 1705.3, what type of special inspection is required to verify the use of required concrete design mix?

Periodic special inspection.

Table 1705.3 Item 5

What is the maximum horizontal floor area permitted between draftstops in combustible floor/ceiling assemblies in occupancies other than Group R?

1,000 square feet (93 m2)

718.3

For each selected wind direction, the wind exposure of the building shall be determined for the two upwind sectors extending how many degrees either side of the selected wind direction?

45 degrees (0.79 rad)

1609.4.1

Sprayed polyurethane foam roofs shall have a design slope of not less than what minimum units vertical in 12 units horizontal for drainage?

1/4 unit

1507.13.1

For Assembly occupancies (Nightclubs, bars, taverns, dance halls, etc.), what is the required ratio for lavatories?

1 per 75

Table 2902.1

Where venting only one appliance, two flues are permitted to adjoin each other in the same chimney with only the flue lining separation between them, provided the joints of the adjacent flue linings are staggered not less than:

4 inches (102 mm)

2113.14 Exception

According to Table 1507.7.6, what is the minimum required headlap (in inches) for slate shingles installed on a slope of 12:12?

3

1507.7.6

Architectural cast stone must conform to which standard?

TMS 504

2103.1

For wood products impregnated with chemicals by a pressure process to be qualified as fire-retardant-treated wood, the process must be performed under pressures not less than what minimum gauge pressure?

50 pounds per square inch gauge (psig)

2303.2.2

In Group I-3 occupancies (Conditions 3 or 4), remote release of locks on required egress doors shall be capable of being released within what maximum time period?

2 minutes

408.4.1