“This full-length timed practice exam replicates real ICC testing conditions, challenging you with randomized questions and strict time limits to measure your readiness under true exam pressure.”

You will have 3.5 hours to complete your exam.

GOOD LUCK


2023 Commercial Electrical Inspector

80 Questions

3.5 Hours

1 / 80

1. What action is a listed interactive inverter permitted to take, instead of automatically disconnecting all ungrounded conductors, when one or more phases of the interconnected primary source opens?

2 / 80

2. Feeder or branch circuits for a swimming pool installed in a corrosive environment must contain an insulated copper equipment grounding conductor (EGC) not smaller than which size?

3 / 80

3. Short sections of raceways used to provide support or protection of cable assemblies from physical damage are NOT required to be what?

4 / 80

4. What is the maximum interval permitted for securing LFNC when installed in lengths exceeding 1.8 m (6 ft)?

5 / 80

5. For maintenance of a wind turbine, all 125-volt, single-phase, 15- and 20-ampere receptacles installed for this purpose must have what specific protection?

6 / 80

6. When is a grounding electrode system and GEC NOT required for a building supplied by a feeder or branch circuit?

7 / 80

7. Type 3 SPDs are permitted to be installed on the load side of branch-circuit overcurrent protection up to the equipment served. If specified in manufacturer’s instructions, what is the minimum conductor distance required from the service or separately derived system disconnect?

8 / 80

8. In other than one- and two-family dwellings, where must a sign be placed for an Optional Standby Power Source?

9 / 80

9. Is the installation of conductors permitted in cellular metal floor raceways in any hazardous (classified) location?

10 / 80

10. Where structural members do not readily permit fastening RMC within 900 mm (3 ft) of a termination point, the fastening distance shall be permitted to be increased to what maximum distance?

11 / 80

11. For track lighting in commercial occupancies, what is the additional load that must be included for every 600 mm (2 ft) of lighting track or fraction thereof?

12 / 80

12. If a conductor in a cable assembly operating at 120 volts has a gray outer finish and is reidentified for use as an ungrounded conductor, what color can the reidentification marking NOT be?

13 / 80

13. Inverter output circuits are permitted to occupy the same junction box, pull box, or wireway with Solar PV system DC circuits, provided they are grouped and identified as required by which subsections?

14 / 80

14. Where a portable optional standby source is used as a nonseparately derived system, what action must be taken regarding the equipment grounding conductor?

15 / 80

15. If a Flow Battery System experiences an electrolyte leak, what safety measure must be provided?

16 / 80

16. For conductors and live parts up to 22 kV or less to ground, what is the minimum vertical clearance required over roofs or projections that are NOT readily accessible to people?

17 / 80

17. For raceways or cables exposed to direct sunlight on or above rooftops, if the distance above the roof to the bottom of the raceway or cable is less than 19 mm (3/4 in.), what temperature adder shall be applied to the outdoor temperature?

18 / 80

18. Arc-fault circuit-interrupter type and ground-fault circuit-interrupter type replacement receptacles shall be installed in what type of location?

19 / 80

19. What type of conductor material shall be used to carry current unless otherwise provided in this Code?

20 / 80

20. Which two markings are required on all nonlocking-type, 125 volt , 15text{-} and 20(ampere) receptacles controlled by an automatic control device?

21 / 80

21. For individual open conductors exposed to the weather and operating at 1000 volts, what is the minimum required distance between supports when conductors are separated by 150 mm (6 in.)?

22 / 80

22. Enclosures for overcurrent devices shall generally be mounted in a vertical position, but listed busway plug-in units are permitted to be mounted in which orientation?

23 / 80

23. What type of loads are prohibited on impedance grounded systems operating between 480 volts and 1000 volts?

24 / 80

24. Where grounding-type receptacles are supplied through a GFCI in a replacement scenario lacking an equipment grounding conductor, the receptacle or cover plate must be marked “GFCI Protected” and with which other visible marking?

25 / 80

25. A handhole is not required in a pole 8 ft. or less in height abovegrade if the supply wiring method continues without splice or pull point, and access to the interior is gained by removing what?

26 / 80

26. If fuses are of the type that can be operated as a disconnecting switch, a set of such fuses shall be permitted to be used as what specific component in the service installation?

27 / 80

27. For a separately derived system, where must the SPD be connected?

28 / 80

28. Outlet boxes or fittings used at luminaire or lampholder outlets on a vertical surface that are permitted to support a luminaire weighing more than 23 kg (50 lb) must be marked on the interior of the box to indicate what?

29 / 80

29. Conductors tapped to a feeder shall be permitted to be protected by the feeder overcurrent device where that device also protects what other component?

30 / 80

30. What type of branch circuits supplying egress lighting, life-critical stunts, or life-critical special effects shall not be protected by GFCIs?

31 / 80

31. Are reconditioned reactors permitted to be installed on electrical circuits?

32 / 80

32. What type of current, such as that resulting from required grounding and bonding connections, is NOT classified as objectionable current?

33 / 80

33. Which cable listed in Table 400.4 is permitted for use in wet locations and is characterized by Extra-hard usage?

34 / 80

34. What must be provided about service equipment, switchboards, and motor control centers that are installed indoors?

35 / 80

35. For a grounded system, if the substantial structure supporting service conductors over a roof is metal, it shall be bonded by means of a bonding jumper and listed connector to where?

36 / 80

36. What must be available to the authority having jurisdiction regarding the ground-fault protection system testing?

37 / 80

37. What is the minimum nominal insulation thickness in mils for Type HF ECTFE fixture wire?

38 / 80

38. In industrial installations only, secondary conductors not over 7.5 m (25 ft) long are permitted without protection at the secondary connection if the sum of the ratings of the overcurrent devices does not exceed what value?

39 / 80

39. For adjustable-speed drive systems rated over 1000 Volts, the conductors supplying the power conversion equipment must have an ampacity not less than what percentage of the rated input current to the power conversion equipment?

40 / 80

40. Field-assembled extension cords and multiconductor cable assemblies consisting of listed connectors and cable are permitted in what specific areas of studios and remote locations?

41 / 80

41. When splicing conductors by soldering, what must occur before the splice is soldered?

42 / 80

42. All energized equipment parts located in the fire pump room must be located at least what minimum distance above the floor level?

43 / 80

43. How many 120-volt, 20-ampere branch circuits must be provided to supply the required bathroom receptacle outlet(s) and any countertop and similar work surface receptacle outlets in a dwelling unit?

44 / 80

44. Equipment having an open circuit voltage exceeding 1000 volts shall not be installed in or on which type of occupancy?

45 / 80

45. When establishing a new Legally Required Standby System, who is responsible for conducting or witnessing the commissioning of the complete installed system?

46 / 80

46. The requirement for Ground-Fault Protection for Personnel (590.6) applies to temporary wiring installations used to supply temporary power to equipment used by personnel during which activities?

47 / 80

47. Ground-fault protection of equipment is required for each service disconnect rated how many amperes or more?

48 / 80

48. Cords and cables used for supply to border lights, drop boxes, and connector strips shall be listed for what specific usage rating?

49 / 80

49. For transformers rated over 1000 Volts with impedance not more than 6 percent , what is the maximum permissible primary circuit breaker setting in any location?

50 / 80

50. An insulated copper equipment grounding conductor, identified along its entire length by green insulation, must be connected to the non-current-carrying conductive surfaces of fixed electrical equipment likely to become energized operating at what minimum voltage?

51 / 80

51. The two to six service disconnects permitted must be grouped, with the exception of one disconnect used only for which specific equipment?

52 / 80

52. Solid aluminum conductors of what AWG sizes must be made of an AA-8000 series electrical grade aluminum alloy conductor material?

53 / 80

53. Conductors shall not be associated together in such a way that the limiting temperature of the conductors is exceeded with respect to the kind of circuit, the number of conductors, or which other factor?

54 / 80

54. How shall bends in NUCC be made?

55 / 80

55. Boxes that enclose devices or utilization equipment supplied by conductors larger than 4 AWG must be identified for what?

56 / 80

56. What is the minimum fire rating required for the walls and roof of an electrical vault?

57 / 80

57. What is the minimum ampere rating of the feeder assembly or service-entrance conductors that the manufacturer must provide in the written installation instructions for manufactured homes?

58 / 80

58. For indoor electrical equipment rated not over 1000 volts, which enclosure type provides protection against incidental contact, falling dirt, falling liquids/light splashing, and circulating dust, lint, fibers, and flyings, but NOT protection against hosedown?

59 / 80

59. When must the markings on flexible bus systems be visible?

60 / 80

60. The 38 mm (1 1/2 in.) spacing requirement under metal-corrugated sheet roof decking is NOT required if the roof decking is covered with a minimum thickness of what material?

61 / 80

61. Interconnection between a surge arrester protecting a transformer and the secondary grounded circuit conductor or grounding electrode conductor requires a metal interconnection if what additional grounding connection exists?

62 / 80

62. For cord- and attachment-plug-connected motor-compressors used on 15text{-} or 20(ampere), 120 volt , or 15(ampere), 208text{-} or 240 volt , single-phase branch circuits, what is the maximum ampere rating permitted for the attachment plug and receptacle or cord connector at 250 Volts?

63 / 80

63. Aircraft energizers (external power sources for aircraft) must be designed and mounted such that all electrical equipment and fixed wiring will be at least what minimum height above floor level?

64 / 80

64. Fixed electric space-heating loads shall be calculated at what percentage of the total connected load?

65 / 80

65. Where service heads or goosenecks cannot be located above the point of attachment of the service conductors, the service head or gooseneck location shall be permitted not farther than what maximum distance from the point of attachment?

66 / 80

66. What general form is NUCC provided in?

67 / 80

67. Where shall splices and taps be made in cellular concrete floor raceways?

68 / 80

68. Cablebus shall be protected against overcurrent in accordance with the ampacity of the cablebus conductors as specified in which NEC section?

69 / 80

69. What demand factor percentage applies to the remainder of general lighting load over 120,000 VA in a Dwelling Unit?

70 / 80

70. Outdoor overhead conductors over 1000 volts are permitted for what three circuit types?

71 / 80

71. The continuous current rating of a circuit breaker shall not be less than what value?

72 / 80

72. For a service rated 200 amperes supplying the entire load associated with a one-family dwelling, what is the minimum required size for aluminum or copper-clad aluminum service conductors, if no adjustment or correction factors are required?

73 / 80

73. When nonmetallic-sheathed cables pass through holes in metal framing members, how must the cable be protected?

74 / 80

74. In supervised industrial installations (Part VIII), where the overcurrent device is rated over 800 amperes, the ampacity of the conductors it protects shall be equal to or greater than what percentage of the rating of the overcurrent device?

75 / 80

75. For motor-driven electric space-heating equipment with a motor rated over 1/8(hp) and without supplementary overcurrent protection, a disconnecting means shall be located where?

76 / 80

76. The size of the DC system bonding jumper shall not be smaller than what conductor?

77 / 80

77. Type S adapters shall be designed so that once inserted in a fuseholder, they cannot be what?

78 / 80

78. When installed at services, Type 1 SPDs shall be connected to which of the following locations?

79 / 80

79. How must the grounded conductor of a mineral-insulated, metal-sheathed cable (Type MI) be identified at the time of installation?

80 / 80

80. For Type ACT cable, where is a moisture-resistant fibrous covering required?