“This untimed practice quiz simulates the ICC exam format, giving you full exposure to real-style questions while allowing unlimited time to navigate, learn, and build confidence without time pressure.”

2023 Commercial Electrical Inspector (Untimed)

80 Questions

3.5 Hours

1 / 80

1. What is the minimum bending radius required for shielded or lead-covered conductors during or after installation?

2 / 80

2. Metal raceways attached to elevator cars must be bonded to metal parts of the car that are bonded to which conductor?

3 / 80

3. In a major repair garage (lighter-than-air fuels), the area within 18 in. of the ceiling is unclassified if ventilation of at least 0.3text{ m}^{3}/text{min}/text{m}^{2} / 1text{ ft}^{3}/text{min}/text{ft}^{2}) is provided with suction taken from where?

4 / 80

4. Dimmer and electronic control switches shall be used only to control which type of loads, unless listed for the control of other loads?

5 / 80

5. Recessed high-intensity discharge luminaires designed to be installed in wall or ceiling cavities must have thermal protection and be identified as what?

6 / 80

6. What must normally non-current-carrying conductive materials enclosing electrical conductors or equipment be connected to, according to 250.4(A)(2)?

7 / 80

7. If the supply conductors from a permanently installed outdoor generator set terminate at a disconnecting means in or on a building, what requirements must that disconnecting means meet?

8 / 80

8. What voltage shall be considered when determining the required interrupting rating of equipment intended to interrupt current at fault levels?

9 / 80

9. ENT shall not be used in theaters and similar locations, except as provided in which two specific sections?

10 / 80

10. For an irrigation machine with inherent intermittent duty, what percentage of the largest motor’s full-load current rating is used when determining the equivalent continuous-current rating?

11 / 80

11. What is required to be provided to prevent contact with nonshielded cables or energized parts of oil-filled cutouts?

12 / 80

12. What restriction applies to bare or covered aluminum or copper-clad aluminum grounding electrode conductors without an extruded polymeric covering?

13 / 80

13. For metal-enclosed busways over 1000 volts, what is the goal regarding temperature rise from induced circulating currents in adjacent ferrous metal parts?

14 / 80

14. For unenclosed spray processes, electrical wiring and equipment located outside but within 20 ft. horizontally and 10 ft. vertically of the enclosed spray area shall be suitable for which classification?

15 / 80

15. Short-circuit current rating markings are not required for industrial control panels containing only which components?

16 / 80

16. Masts used to support final spans of feeders or branch circuits must be installed in accordance with 225.17(A) and (B). True or False?

17 / 80

17. Which wiring method is permitted to be installed in exposed or concealed locations under metal-corrugated sheet roof decking without maintaining the 38 mm (1 1/2 in.) spacing requirement?

18 / 80

18. Where a pipe heating cable outlet is installed in a park trailer, it must be located within what maximum distance of the cold water inlet?

19 / 80

19. For LP-Gas dispensing devices, what is the extent of the Class I, Division 1 classified location?

20 / 80

20. Factory-installed receptacle outlets that are part of a permanently installed electric baseboard heater shall not be connected to which circuits?

21 / 80

21. A cable, raceway, or box installed under metal-corrugated sheet roof decking must be supported so there is not less than what minimum clearance measured from the lowest surface of the roof decking to the top of the installation?

22 / 80

22. In supervised industrial installations (Part VIII), where the overcurrent device is rated over 800 amperes, the ampacity of the conductors it protects shall be equal to or greater than what percentage of the rating of the overcurrent device?

23 / 80

23. Which types of RMC are permitted under all atmospheric conditions and occupancies?

24 / 80

24. To determine the equivalent horsepower of a disconnecting means for a hermetic refrigerant motor-compressor, the horsepower rating corresponding to which current rating must be selected from the applicable tables?

25 / 80

25. Installations under the exclusive control of an electric utility located on property owned or leased by the utility for the purpose of transformation are not covered by this Code. True or False?

26 / 80

26. A power transformer connected toward the interactive inverter output in a Solar PV system is permitted without overcurrent protection from the inverter if its current rating on the side connected toward the inverter output is not less than what value?

27 / 80

27. What type of ignition sources involving equipment features are specifically not covered by Article 505?

28 / 80

28. If a single-phase, 2-wire ESS output is connected to the grounded/neutral conductor of a 3-wire system, the ampacity of the grounded/neutral conductor shall not be exceeded by the sum of the maximum unbalanced neutral load current plus what other rating?

29 / 80

29. What is the ampacity for 4/0 AWG aluminum conductor, Type XHHW-2, installed in a raceway or earth (direct buried) under standard conditions (30°C ambient, 3 CCC)?

30 / 80

30. For pull and junction boxes used on systems over 1000 volts, which section covering conductor fill is specifically required to be complied with?

31 / 80

31. What is the ampacity for a 12 AWG, 90°C conductor, when there are up to four simultaneously energized ac conductors in a cable, rated for 60-minute service?

32 / 80

32. If tap conductors not over 3 m (10 ft) long leave the enclosure or vault in which the tap is made, the ampacity of the tap conductors shall be not less than what proportion of the rating of the feeder overcurrent protective device?

33 / 80

33. When unused metallic plugs or plates are used to close unused openings in nonmetallic enclosures, what minimum distance must they be recessed from the outer surface of the enclosure?

34 / 80

34. Conductors that are more finely stranded than Class B and Class C stranding shall use connectors and terminals that are identified for what?

35 / 80

35. Ground clamps or other fittings exposed to physical damage must be enclosed in what materials?

36 / 80

36. Open service conductors must be attached to fittings identified for use with service conductors or to noncombustible, nonabsorbent insulators that are securely attached to what?

37 / 80

37. A surge arrester shall not be installed where its rating is less than the maximum continuous phase-to-ground voltage available at what point?

38 / 80

38. In addition to the requirements of Article 470, the installation of oil-filled reactors shall comply with applicable requirements of which two specific Parts of Article 450?

39 / 80

39. Where are splices or taps permitted within auxiliary gutters?

40 / 80

40. When can the authority having jurisdiction (AHJ) grant permission for feeder ampacity less than 100% of the total connected space heating load?

41 / 80

41. In recreational vehicle parks, GFCI protection shall only be required for what specific rating of receptacles installed in the recreational vehicle site equipment?

42 / 80

42. Isolating switches required for services over 1000 volts must be provided with a means for readily connecting the load side conductors to a grounding electrode system or equipment ground busbar when the switch is disconnected from what?

43 / 80

43. Cable trays are permitted to extend through walls/partitions or floors provided the installation, complete with installed cables, is made in accordance with which section?

44 / 80

44. Which of the following is required to be included in a Cablebus system?

45 / 80

45. If a disconnecting means is required to be lockable open, the provisions for locking shall:

46 / 80

46. Ungrounded conductors tapped from a grounded system must be controlled by switching devices that manually switch all poles together if the device serves as a disconnecting means for which appliance?

47 / 80

47. Service conductors supplying one building are generally prohibited from passing through which area of another building or structure?

48 / 80

48. What are the two standard ampere ratings listed in Table 240.6(A) immediately following 600 amperes?

49 / 80

49. Which factor must be applied to the maximum load to be served when determining the minimum service-entrance conductor size, in addition to continuous load adjustments?

50 / 80

50. What is the maximum number of electronic control switches permitted on a single branch circuit, as specified in the exception to 404.2(C)}?

51 / 80

51. Each smoothing iron and other cord-and-plug-connected electrically heated appliance intended to be applied to combustible material shall be equipped with what component?

52 / 80

52. What is the minimum trade size permitted for NUCC?

53 / 80

53. If multiple Class A protective devices are used for an appliance, how many are required by the code?

54 / 80

54. What must be coordinated to prevent damaging or dangerous temperatures in conductors or conductor insulation under short-circuit conditions?

55 / 80

55. On 3-phase, 3-wire circuits, an overcurrent relay element in the residual circuit of the current transformers shall be permitted to replace which component?

56 / 80

56. What minimum marking requirement must be field-applied at the permanent connection point for a temporary generator serving an Emergency System?

57 / 80

57. In outdoor installations of service equipment, switchboards, or motor control centers, the dedicated equipment space must extend from grade to a height of how far above the top of the equipment?

58 / 80

58. Services used for temporary installations shall be installed in conformance with which parts of Article 230, as applicable?

59 / 80

59. Where shall the grounded conductor of each separately derived system be bonded to the metal water piping system?

60 / 80

60. If fuses are of the type that can be operated as a disconnecting switch, a set of such fuses shall be permitted to be used as what specific component in the service installation?

61 / 80

61. In a multiple-occupancy building, service and feeder overcurrent protective devices supplying more than one occupancy shall be permitted to be accessible only to authorized management personnel, provided electric service and electrical maintenance are provided by the building management and under what supervision condition?

62 / 80

62. Branch circuits larger than 50 amperes shall supply only what type of outlet loads?

63 / 80

63. A neutral conductor shall not be used for more than one branch circuit, for more than one multiwire branch circuit, or for how many sets of ungrounded feeder conductors?

64 / 80

64. Which rating is NOT required to be shown on a circuit breaker nameplate?

65 / 80

65. What demand factor percentage applies to the portion of general lighting load between 20,001 VA and 100,000 VA in a Hotel or Motel?

66 / 80

66. If a written record of Energy Storage System (ESS) maintenance is required, what must this record specifically include?

67 / 80

67. In dry board applications, heating cable must be installed parallel to the joist, leaving a clear space centered under the joist of what minimum width between centers of adjacent cable runs?

68 / 80

68. For conductors and live parts up to 22 kV or less to ground, what is the minimum horizontal clearance required from building walls, projections, and windows?

69 / 80

69. Conductors tapped to a feeder shall be permitted to be protected by the feeder overcurrent device where that device also protects what other component?

70 / 80

70. Conductors of circuits rated over 1000 volts ac, 1500 volts dc, nominal, shall generally NOT occupy the same enclosure with conductors of circuits rated 1000 volts ac, 1500 volts dc, nominal, or less, unless otherwise permitted. True or False?

71 / 80

71. Adjustment factors shall not apply to conductors installed in raceways having a length not exceeding what maximum distance?

72 / 80

72. When auxiliary equipment for electric-discharge lamps is supplied by the ungrounded conductors of a circuit, the switching device must simultaneously disconnect all which conductors?

73 / 80

73. What type of thread is prohibited from being used on RMC for connection at couplings?

74 / 80

74. When determining the electrical datum plane in land areas subject to storm-driven flooding, how high above the point identified as the prevailing high water mark must the horizontal plane be set?

75 / 80

75. Which two hazards must be considered at a minimum during the Risk Assessment for Critical Operations Power Systems (COPS)?

76 / 80

76. Strut-type channel raceways are permitted as extensions through walls, partitions, and floors under what condition regarding access?

77 / 80

77. Dry-type transformers 1000 Volts, nominal, or less, located in the open on walls, columns, or structures, shall not be required to be what?

78 / 80

78. Motors rated less than 1/8 hp connected to a lighting circuit in a dwelling unit shall be considered part of what load?

79 / 80

79. What size information is required to be marked on all IBP?

80 / 80

80. PVC conduit is permitted for use in which two general types of locations, provided they are not prohibited by 352.12?