“This untimed practice quiz simulates the ICC exam format, giving you full exposure to real-style questions while allowing unlimited time to navigate, learn, and build confidence without time pressure.”

Residential Electrical Inspector Exam Prep (Product Image)

2024 Residential Electrical Inspector (E1) (Untimed)

60 Questions

2 Hours

1 / 60

1. What is the minimum copper equipment grounding conductor size required for a 400-ampere circuit?

2 / 60

2. Flexible cords used for connection of fixed or stationary pool equipment (other than underwater luminaires) shall not exceed ____ ft in length, except for storable pools.

3 / 60

3. In the areas specified in Section E3901.1, what type of receptacles are required for 15- and 20-ampere, 125- and 250-volt nonlocking-type receptacles?

4 / 60

4. What is the allowable ampacity of a No. 8 AWG aluminum conductor with 75°C insulation?

5 / 60

5. When installed within the zone of a tub or shower, a single receptacle for an electronic toilet or personal hygiene device shall be ______ and not be located ______.

6 / 60

6. Where must an overcurrent device be installed to protect ungrounded branch-circuit and feeder conductors?

7 / 60

7. The ballast of a fluorescent luminaire installed indoors must be provided with ______.

8 / 60

8. A 3 × 2 × 3 1/2 device box may contain a maximum of how many 12 AWG conductors?

9 / 60

9. What is the allowable ampacity of a 3 AWG copper conductor with 75°C insulation?

10 / 60

10. What is the allowable ampacity of a 500 kcmil copper conductor with 75°C insulation?

11 / 60

11. Bare aluminum grounding electrode conductors shall **not** be:

12 / 60

12. What is the minimum clearance required for a recessed LED luminaire with a completely enclosed light source in a closet?

13 / 60

13. When calculating feeder loads, what percentage is applied to the first 3,000 VA or less of lighting and receptacle load?

14 / 60

14. Which best defines ‘Service Point’?

15 / 60

15. Where a disconnecting means is required to be lockable, which of the following is true regarding the locking provisions?

16 / 60

16. If separate services supply a building, which is true regarding grounding electrodes?

17 / 60

17. When service conductors serve 100 percent of the dwelling unit load, the load shall be computed in accordance with:

18 / 60

18. What is the maximum overcurrent protection device rating for a 12 AWG copper conductor?

19 / 60

19. When using a disconnect for permanently installed heating equipment with motors rated at not over 1/8 horsepower and provided with supplementary overcurrent protection, it must be within sight of which of the following?

20 / 60

20. What is the minimum length of rebar or conductor required for a concrete-encased electrode?

21 / 60

21. The indoor dedicated space for a panelboard must equal the width and depth of the panelboard and extend from the floor to:

22 / 60

22. If service conductors serve less than 100 percent of the dwelling unit load, how is the load calculated?

23 / 60

23. What color background and text is required for outdoor emergency disconnect labels?

24 / 60

24. Liquid-tight flexible metal conduit is permitted to serve as an equipment grounding conductor (EGC) only if which of the following conditions is met?

25 / 60

25. When determining interrupting ratings, a fault is assumed to occur between which conductors?

26 / 60

26. In an indoor spa or hot tub area, luminaires or ceiling-suspended paddle fans located above the spa or hot tub and not provided with GFCI protection must be installed at a minimum height of how many feet above the maximum water level?

27 / 60

27. Which method is permitted for splicing a grounding electrode conductor?

28 / 60

28. Which of the following is not permitted? A grounded conductor shall not be connected to normally noncurrent-carrying metal parts of equipment, to equipment grounding conductor(s), or be reconnected to ground on the load side of the service disconnecting means.

29 / 60

29. For a 10-amp branch circuit using copper conductors, what is the maximum load in amperes?

30 / 60

30. Which of the following is permitted to be installed in the same raceway or cable as service conductors?

31 / 60

31. Which of the following statements about using an equipment grounding conductor (EGC) as a grounding electrode conductor (GEC) is correct?

32 / 60

32. Overhead service conductors shall have a clearance of not less than how many feet from the sides and bottom of windows that do not open?

33 / 60

33. What is the minimum length required for rod and pipe electrodes used as grounding electrodes?

34 / 60

34. When derating Type SE cable conductors, the final adjusted ampacity must not exceed the ampacity for what temperature rating?

35 / 60

35. What is the minimum size aluminum or copper-clad aluminum conductor permitted for feeders and branch circuits?

36 / 60

36. A 20-ampere receptacle directly connected to aluminum conductors must be marked as which of the following?

37 / 60

37. If a 30-ampere branch circuit operating at 120 volts is supplying cord-and-plug-connected utilization equipment, the rating of any one piece of equipment shall not exceed how many watts?

38 / 60

38. The heating elements of an electric spa or hot tub water heater shall be subdivided into loads not exceeding how many amperes?

39 / 60

39. How many Class B strands are in a 16 AWG copper conductor?

40 / 60

40. What is the demand factor applied to the first 10,000 volt-amperes of calculated load?

41 / 60

41. What is the maximum overcurrent protection device rating for a 14 AWG copper conductor?

42 / 60

42. Which of the following best describes when exposed metal parts of fixed equipment must be connected to the equipment grounding conductor?

43 / 60

43. When conductors are spliced for direct burial, what is required?

44 / 60

44. Outlet boxes mounted in ceilings of habitable rooms in acceptable locations for installation of paddle fans must either be listed for sole support of the fan or:

45 / 60

45. When more than one ampacity could apply to a circuit length, which value must be used?

46 / 60

46. The required small-appliance branch circuits shall serve receptacle outlets in all of the following areas except:

47 / 60

47. A copper grounding electrode conductor for service entrance conductors over 350 kcmil through 600 kcmil shall be no smaller than what size?

48 / 60

48. In addition to the required small-appliance branch circuits in kitchens and dining areas, additional receptacle outlets for specific appliances may be supplied from what minimum branch circuit rating?

49 / 60

49. For circuits supplying loads consisting of motor-operated utilization equipment that is fastened in place and that has a motor larger than 1/8 horsepower in combination with other loads, the total calculated load shall be based on

50 / 60

50. Overhead service conductors shall have a clearance of not less than how many feet from the sides and bottom of windows that open?

51 / 60

51. The clothes-closet storage space extends vertically to what height from the closet floor or highest clothes-hanging rod?

52 / 60

52. At an ambient temperature of 46–50°C, what is the correction factor for a conductor rated at 75°C?

53 / 60

53. What is the minimum ampacity for ungrounded conductors in all other installations?

54 / 60

54. A floor receptacle can only be counted as part of the required receptacle outlets if it is located within how many inches of the wall?

55 / 60

55. The input leads of a Class 2 transformer that are permitted to be smaller than 14 AWG must have insulation rated at not less than how many volts?

56 / 60

56. What condition must be met for conduit bodies to contain splices, taps, or devices?

57 / 60

57. The grounded conductor of a luminaire must be connected to:

58 / 60

58. What is the maximum receptacle rating permitted on a 20-amp branch circuit?

59 / 60

59. When determining required receptacle outlet locations, wall spaces that are at least how wide must be included in the spacing calculation?

60 / 60

60. Service-entrance conductors entering or on the exterior of buildings must be insulated in accordance with which section?