Residential Mechanical Inspector (M1)
60 Questions
2 Hours
1 / 60
1. Which of the following materials is approved for use in a condensate disposal system?
M1411.9.2
2 / 60
2. What is the maximum allowable pressure differential across the door of a mechanical room when return air is taken from it?
M1602.2 (Item 5)
3 / 60
3. What is the minimum vertical termination height above the highest connected appliance draft hood outlet or flue collar for a single-wall metal pipe?
G2427.7.3
4 / 60
4. Zero lateral length applies only when the vent is:
G2428.2.4 (504.2.4)
5 / 60
5. When a combustion air duct terminates in an attic space, which of the following is true?
G2407.11 (304.11) – Combustion Air Ducts
6 / 60
6. Where is air not permitted to be discharged from a mechanical exhaust system?
M1501.1
7 / 60
7. If not specified by the manufacturer, how far must a dryer exhaust duct terminate from openings into the building?
M1502.3
8 / 60
8. Which pipe joint method is permitted for Schedule 40 or heavier pipe?
G2414.9.1 (403.9.1)
9 / 60
9. What is the minimum required open area for a dryer exhaust duct terminal outlet passageway?
M1502.3.1
10 / 60
10. According to the requirements, what should the pressure relief valve on a boiler be set to?
M2002.4
11 / 60
11. What is the maximum allowed length for a 7-inch diameter smooth-wall exhaust duct for ventilation equipment with a fan rated at 250 CFM?
Table M1504.2
12 / 60
12. Which of the following workmanship requirements must be met during gas piping installation?
G2414.6 (403.6)
13 / 60
13. What is the requirement for the location of appliances to ensure proper air supply?
G2407.2 (304.2) – Appliance Location
14 / 60
14. Plastic pipe venting materials listed to UL 1738 must be installed according to which of the following?
G2427.4.1.1
15 / 60
15. Are new under-floor plenums permitted in residential construction?
M1601.5
16 / 60
16. What is the required minimum melting point of brazing material for nonferrous pipe joints?
17 / 60
17. When a single-wall metal pipe connector for an oil-fired appliance passes through a wall, what is required for protection?
M1803.3.1
18 / 60
18. According to the IRC, combustion air ducts may serve:
19 / 60
19. Which of the following standards must packaged oil-fired boilers conform to?
M2001.1.1
20 / 60
20. Plastic piping used in undiluted LP‑gas systems must comply with which standard?
G2414.5.2 (403.5.2)
21 / 60
21. Where must a draft hood be located in relation to combustion air openings?
M1802.1
22 / 60
22. Draft regulators are required for which of the following appliances when connected to a chimney?
M1802.3
23 / 60
23. If not elevated, how far must an exhaust opening be located from a mechanical air intake?
M1504.3(3)
24 / 60
24. What is the required galvanized sheet metal thickness for a rectangular duct measuring 11 to 12 inches at 1/2-inch water gauge?
Table M1601.1.1
25 / 60
25. Which of the following is not an approved listing and labeling standard for refrigeration cooling equipment?
M1404.1
26 / 60
26. Which of the following is not an allowed location for a vented floor furnace?
M1408.3
27 / 60
27. Where are shutoff valves required to be installed in relation to a heat exchanger in a hydronic piping system?
M2101.22.1
28 / 60
28. What is the minimum required vertical distance above finished ground level for an exterior combustion air intake opening?
29 / 60
29. How shall pressure regulators be vented according to G2421.3?
G2421.3 requires pressure regulators that require a vent to be vented directly to the outdoors.
30 / 60
30. What is the minimum free area required for each combustion air opening when combining spaces on the same story?
G2407.5.3.1 (304.5.3.1) – Combining Spaces on the Same Story
31 / 60
31. What is the maximum horizontal hanger spacing allowed for copper or copper-alloy pipe in hydronic piping systems?
Table M2101.9
32 / 60
32. What is the requirement for conduit terminating outdoors in piping installations?
G2415.8.1 (404.8.1)
33 / 60
33. A dwelling with over 7,500 square feet and more than 7 bedrooms requires what minimum airflow for a continuous whole-house mechanical ventilation system?
Table M1505.4.3(1)
34 / 60
34. What is the minimum intermittent exhaust rate required for a bathroom or toilet room in a one- or two-family dwelling?
Table M1505.5
35 / 60
35. What is the minimum required width of solid flooring along the attic passageway to an appliance?
M1305.1.2
36 / 60
36. When installed on noncombustible flooring, how far must the floor extend beyond a vented room heater on all sides?
M1410.2
37 / 60
37. Before accepting a gas piping system for use what inspections must be completed?
G2417.1 (406.1)
38 / 60
38. What is the minimum thickness for a galvanized steel vent connector for a low-heat appliance with a diameter less than 6 inches?
Table G2427.10.2.4
39 / 60
39. Which of the following is considered part of the required indoor air volume for combustion air?
G2407.5 (304.5) – Indoor Combustion Air
40 / 60
40. Protective steel shield plates must extend how far above sole plates to protect dryer exhaust ducts?
M1502.5
41 / 60
41. Which of the following materials is approved for use as a connector on oil or solid fuel-burning appliances?
M1803.2
42 / 60
42. When sizing a vent for a high-altitude installation, what input rating should be used to determine the minimum capacity?
G2428.3.10 (504.3.10)
43 / 60
43. What must happen if a condensate pump located in an attic or crawl space fails?
M1411.10
44 / 60
44. Electric duct heaters must comply with which listing standard?
M1407.1
45 / 60
45. When a chimney formerly used for liquid or solid fuel appliances is repurposed for gas appliances, the cleanout’s upper edge must be located how far below the lowest chimney inlet opening?
G2427.5.8
46 / 60
46. What is required if the pressure drop results in supply pressure lower than the appliance minimum?
G2413.6 (402.6)
47 / 60
47. Which term in venting system tables indicates that a vent configuration is not permitted due to condensate risk or geometric limitations?
G2428.1 (504.1)
48 / 60
48. In what location are individual shutoff valves required for each boiler or modular boiler in multiple boiler installations?
M2001.3
49 / 60
49. What is not permitted when working with load-bearing members of cold-formed steel light-frame construction?
M1308.1
50 / 60
50. When is a sediment trap not required?
G2419.4 (408.4)
51 / 60
51. What must be included on the label of a fuel-burning unit?
M1303.1
52 / 60
52. When vents pass through insulated assemblies, what is the minimum required thickness of the steel used for the insulation shield?
G2426.4
53 / 60
53. Which of the following statements about return air is correct?
G2442.5
54 / 60
54. Which of the following mounting practices is permitted for wall-mounted illuminating appliances?
G2450.2
55 / 60
55. Installation of conversion burners must conform to which standard?
G2443.1
56 / 60
56. What is the maximum horizontal length allowed for a Type B double-wall vent connector, unless part of an engineered system?
G2427.10.9 (503.10.9)
57 / 60
57. What is the required number of threads to be cut on a 1-inch iron pipe according to table G2414.8.2?
Table G2414.8.2 (403.8.2)
58 / 60
58. What must fuel-fired appliances be designed for?
M1304.1
59 / 60
59. For oil-fired or solid fuel-burning appliances, what is the minimum allowable connector size when connected to a natural draft chimney?
M1803.3.3
60 / 60
60. Refrigeration systems using Group A1 refrigerants must be listed in accordance with:
M1411.2