2024 Residential Plans Examiner (R3) (Untimed)

60 Questions

2 Hours

1 / 60

1. A dry vent connecting to a horizontal drain shall connect in which position relative to the centerline of the horizontal drain pipe?

2 / 60

2. If the free area of a metal louver or grille is not known, what percentage of its gross area should be assumed as free area?

3 / 60

3. A Type L vent system used with a solid fuel or oil-fired appliance must conform to which listing requirement?

4 / 60

4. Which of the following would NOT be an acceptable identification method for a 4 AWG or larger insulated grounded conductor?

5 / 60

5. How far must chimney anchorage straps be embedded into the chimney?

6 / 60

6. What is the minimum required lap for horizontal application of No. 15 felt or ASTM E2556-compliant barriers?

7 / 60

7. What is the minimum lap required for fiber-cement lap siding?

8 / 60

8. What is the required fire separation distance for dwellings without sprinklers or fire-rated walls?

9 / 60

9. Combustion air for solid fuel-burning appliances must be provided in accordance with:

10 / 60

10. When installing polyethylene pipe, bends within what distance of any fitting or valve are prohibited?

11 / 60

11. How is a conflict between a referenced code and the IRC resolved?

12 / 60

12. How many fasteners are required per slate shingle during installation?

13 / 60

13. Which of the following is an acceptable bracing element for the bottom flange of roof rafters?

14 / 60

14. What is the maximum allowable span for a 2×6, #3 grade Hem-fir rafter spaced 24 inches apart, with a dead load of 20 psf, ceiling attached, and a roof live load of 50 psf?

15 / 60

15. What is the minimum required height for a parapet wall separating townhouses?

16 / 60

16. Where a storage tank-type water heater is installed in a location where water leakage will cause damage, the pan constructed of galvanized steel or aluminum must have a thickness of not less than what dimension?

17 / 60

17. Which wiring method is not permitted to be run exposed?

18 / 60

18. Which type of metallic piping is permitted to be placed in direct contact with masonry or concrete?

19 / 60

19. The minimum flexible cord length permitted for an in-sink waste disposal is:

20 / 60

20. What is the minimum required size and thickness for header and trimmer joists used in cold-formed steel floor openings?

21 / 60

21. What is the minimum thickness of a solid wood door used to separate a garage and a sleeping room of a dwelling unit?

22 / 60

22. What is the minimum required guard height for a residential balcony?

23 / 60

23. In windborne debris regions, what test standards must impact protective systems comply with for impact resistance?

24 / 60

24. What is the maximum design live load permitted for floor joists supporting areas other than sleeping areas and attics?

25 / 60

25. What is the required minimum depth of a landing for an exterior egress door?

26 / 60

26. What is the minimum required distance between the centerline of a toilet and a sidewall?

27 / 60

27. For hydronic piping systems, copper tubing embedded in concrete must have what type of joints?

28 / 60

28. Fireplace stoves must be tested in accordance with which of the following standards?

29 / 60

29. What is the minimum required thickness for rubble stone masonry foundation walls?

30 / 60

30. Where none of the required conductive surfaces are bonded in direct connection with the pool water, the pool water shall be in contact with an approved corrosion-resistant conductive surface exposing not less than how many square inches of surface area to the water at all times?

31 / 60

31. What is the required type of backwater valve when plumbing fixtures are installed on a floor with a finished floor elevation above the elevation of the next upstream manhole cover?

32 / 60

32. What is the minimum footing size (width × thickness in inches) required for a 1-story cast in-place concrete with crawl space structure with a 50 psf roof live load and 1,500 psf soil bearing capacity?

33 / 60

33. External reflective duct insulation must be labeled at intervals not exceeding:

34 / 60

34. What is the maximum allowable slope for a ramp serving an egress door?

35 / 60

35. If the depth-to-thickness ratio exceeds 6 to 1, how must rafters and ceiling joists be supported laterally?

36 / 60

36. Factory-built chimneys used to vent appliances operating under positive vent pressure must meet which of the following requirements?

37 / 60

37. What is the minimum thickness for a concrete slab-on-grade for habitable spaces?

38 / 60

38. What are the minimum required dimensions for the passageway to access appliances located under floors?

39 / 60

39. Which standard applies to Polyethylene (PE) plastic pipe used for subsoil drains?

40 / 60

40. What is the required minimum net clear opening height for an emergency escape and rescue opening?

41 / 60

41. True or False: Raceways embedded in masonry are not required to be arranged to drain.

42 / 60

42. The standard reference design is a version of the proposed design used to determine which requirement?

43 / 60

43. Domestic cooking appliances with integral downdraft exhaust must be listed and labeled in accordance with:

44 / 60

44. For CSST that is not arc-resistant the bonding jumper shall be connected to which of the following?

45 / 60

45. A 1-2×12 header is supporting a roof, ceiling, and two clear-span floors in a 36-foot-wide building with a 50 psf snow load. What is the maximum allowable span?

46 / 60

46. What type of bracing method is used for continuously sheathed portal frames (CS-PF)?

47 / 60

47. What is the maximum allowable hole diameter in a solid lumber joist, rafter, or beam?

48 / 60

48. Where must renewable energy resources be harvested to be classified as on-site renewable energy?

49 / 60

49. What is the maximum allowable deflection for a residential floor joist under live load?

50 / 60

50. If a laundry tray waste line connects into a standpipe for an automatic clothes washer, the standpipe must extend not less than how far above the standpipe trap weir?

51 / 60

51. What is the minimum thickness of a solid wood door used to separate a garage and a dwelling unit?

52 / 60

52. What is the minimum height of a guardrail required for stairways more than 30 inches above grade?

53 / 60

53. What protection is required for wood columns according to the IRC?

54 / 60

54. A metal underground water pipe must be in direct contact with the earth for a minimum of how many feet to qualify as a grounding electrode?

55 / 60

55. In what condition is solid sheathing required under wood shingles?

56 / 60

56. Which of the following is listed as a prohibited trap design?

57 / 60

57. Ungrounded service conductors for other than dwelling units shall have an ampacity of not less than how many amperes?

58 / 60

58. What is the minimum footing size (width × thickness in inches) required for a 3-story light-frame with brick veneer crawl space structure with a 50 psf roof live load and 2,000 psf soil bearing capacity?

59 / 60

59. What is the allowable ampacity of a No. 2 AWG aluminum conductor with 60°C insulation?

60 / 60

60. At an ambient temperature of 41–45°C, what is the correction factor for a conductor rated at 90°C?