You will have 2 hours to complete your exam.

GOOD LUCK


Residential Building Inspector (B1)

60 Questions

2 Hours

1 / 60

1. What is the minimum thickness of a solid wood door used to separate a garage and a sleeping room of a dwelling unit?

2 / 60

2. What size wood furring strips are permitted over solid backing or framing spaced not more than 24 inches on center?

3 / 60

3. When using stay-in-place forms for concrete walls, what condition allows self-consolidating concrete to be placed without internal vibration?

4 / 60

4. What is the maximum gap allowed between non-contact parallel bars at a lap splice in foundation walls?

5 / 60

5. What requirement applies to concrete foundation stem walls supporting above-grade concrete walls that support above-grade concrete walls when they are not laterally supported at the top?

6 / 60

6. Which of the following is NOT exempt from a permit?

7 / 60

7. What is the minimum square footage required for a habitable room?

8 / 60

8. What is the minimum net clear opening required for an emergency escape and rescue opening located on grade floor?

9 / 60

9. What is the maximum permitted thickness of anchored stone or masonry veneer installed over wood or cold-formed steel framing?

10 / 60

10. What is the maximum allowable span for a 2×10 Douglas Fir-Larch #1 joist at 16-inch spacing with a 10 psf dead load when supporting living areas?

11 / 60

11. What is the required minimum net clear opening width for an emergency escape and rescue opening?

12 / 60

12. What is the maximum allowable span for a 2×6, #2 grade Douglas fir-larch rafter spaced 16 inches apart, with a dead load of 10 psf, ceiling attached, and a roof live load of 20 psf?

13 / 60

13. What is the minimum footing size (width × thickness in inches) required for a 3-story cast in-place concrete with basement structure with a 30 psf roof live load and 1,500 psf soil bearing capacity?

14 / 60

14. For wood foundation walls not designed and installed in accordance with AWC PWF, what is the maximum allowable backfill height?

15 / 60

15. What is the minimum required ventilation area for an attic space?

16 / 60

16. According to the IRC, in nonbearing walls, what is the maximum width for an opening where a single flat 2×4 header can be used?

17 / 60

17. In flood hazard areas, what requirement applies to walls enclosing under-floor spaces?

18 / 60

18. How long does a permit remain valid if work does not commence?

19 / 60

19. What is the definition of ‘Registered Design Professional’ in the IRC?

20 / 60

20. What is the minimum footing size (width × thickness in inches) required for a 2-story plus basement, light-frame slab-on-grade structure with a 30 psf roof live load and 1,500 psf soil bearing capacity?

21 / 60

21. Cold-formed steel roof framing is limited to what maximum ultimate design wind speed under the standard applicability limits?

22 / 60

22. According to the IRC, what design loads must decks be designed for?

23 / 60

23. According to the IRC, when joists, trusses, or rafters are spaced more than 16 inches on center, how close must they bear to the studs beneath when those studs are spaced at 24 inches on center?

24 / 60

24. What information must be included in a stop-work order?

25 / 60

25. Vinyl siding must be certified as conforming to which of the following standards?

26 / 60

26. When is a drainage system NOT required around concrete or masonry foundations?

27 / 60

27. Structural wood structural panel sheathing must conform to which standard?

28 / 60

28. What is the maximum allowable span for a 3-2×8 header supporting a roof, ceiling, and two center-bearing floors in a 24-foot-wide building with a 50 psf ground snow load?

29 / 60

29. How must precast concrete foundation walls be designed?

30 / 60

30. How does the horizontal reinforcement requirement change for concrete basement walls greater than 8 feet in height?

31 / 60

31. What is the minimum required extension distance for a roll brace perpendicular to the edge member?

32 / 60

32. When must truss design drawings be submitted to the building official for approval?

33 / 60

33. What is the required fastener type and spacing for nailing a single-member header in place?

34 / 60

34. What is the maximum allowable span for a 2×8 Southern Pine #2 joist at 12-inch spacing with a 10 psf dead load when supporting sleeping areas?

35 / 60

35. What is required for rooftop-mounted photovoltaic panel systems in terms of fire classification?

36 / 60

36. What is the maximum cantilever distance allowed for wood structural panel roof sheathing beyond the gable endwall without additional support?

37 / 60

37. Cold-formed steel walls constructed must be limited to sites where the ultimate design wind speed is less than?

38 / 60

38. How many No. 4 vertical bars are required for chimneys up to 40 inches wide?

39 / 60

39. For a 40-foot-wide building with a ground snow load of 70 psf, how many No. 10 screws are required at each leg of the clip angle?

40 / 60

40. Under standard conditions, each masonry veneer tie is allowed to support how much wall area?

41 / 60

41. What is the minimum net thickness of lumber roof sheathing required for rafters spaced 24 inches on center?

42 / 60

42. What is the allowable span for a 550S162-43 ceiling joist at 24-inch spacing with third-point bracing for a live load of 10 psf?

43 / 60

43. Anchor bolts securing cold-formed steel framed walls to foundations or floors must be located no more than how many inches from corners or the termination of bottom tracks?

44 / 60

44. When must roof framing members and ceiling joists be provided with lateral support at points of bearing?

45 / 60

45. How must the steel angle be anchored to double wood studs for supporting masonry veneer?

46 / 60

46. For a plain masonry foundation wall with 9 feet of unbalanced backfill, 9 feet of unsupported wall height, and GW soil, what is the minimum wall thickness required?

47 / 60

47. What material must be placed between a concrete slab and the base course or prepared subgrade, unless exempt?

48 / 60

48. For three-story buildings, when the third-floor live load is increased to 40 pounds per square foot (1920 Pa), what adjustment must be made when selecting the stud size?

49 / 60

49. In buildings assigned to Seismic Design Category D0, D1, or D2, what is the minimum nominal thickness required for plain masonry foundation walls?

50 / 60

50. According to the IRC, when is blocking not required for cold-formed steel floor joists at interior bearing supports?

51 / 60

51. What is required when a braced wall panel is installed where floor joists are parallel to it?

52 / 60

52. When plain concrete foundation walls are permitted by Tables R404.1.3.2(2) through R404.1.3.2(8), what is the minimum required vertical reinforcement?

53 / 60

53. What is the required number of No. 10 screws for a 10/12 roof slope with 32-foot building width and 30 psf ground snow load?

54 / 60

54. What is required for the starter course at the eaves when installing wood shakes?

55 / 60

55. What is the responsibility of the contractor regarding code compliance?

56 / 60

56. What is the minimum curing time required before applying the finish coat for a two-coat cement plaster system?

57 / 60

57. In Seismic Design Categories D0, D1, and D2, where must braced wall panels be located?

58 / 60

58. Which of the following bracing methods do NOT require interior finish material opposite the braced wall panel?

59 / 60

59. How must sawn lumber used for load-supporting purposes be identified?

60 / 60

60. What is the minimum net thickness of lumber floor sheathing required for joists spaced 24 inches on center, when installed diagonally to the joists?