“This untimed practice quiz simulates the ICC exam format, giving you full exposure to real-style questions while allowing unlimited time to navigate, learn, and build confidence without time pressure.”

Residential Electrical Inspector Exam Prep (Product Image)

2024 Residential Electrical Inspector (E1) (Untimed)

60 Questions

2 Hours

1 / 60

1. What is the minimum size bare copper conductor permitted for a concrete-encased electrode?

2 / 60

2. Which of the following is permitted within the 6-foot dedicated indoor panelboard space?

3 / 60

3. If separate services supply a building, which is true regarding grounding electrodes?

4 / 60

4. What is the minimum conductor size (AWG) for a 30-amp branch circuit using aluminum or copper-clad aluminum conductors?

5 / 60

5. What is the maximum rating of the next higher standard overcurrent device permitted above the ampacity of the conductors?

6 / 60

6. Receptacle assemblies and GFCI receptacle assemblies installed in work surfaces must be ______.

7 / 60

7. For a panelboard rated at 225 amperes or less and designed to contain not more than 42 overcurrent devices, what is the minimum top or bottom wire-bending space required for two wires per terminal sized 250 kcmil?

8 / 60

8. Which of the following best defines ‘Overcurrent’?

9 / 60

9. Boxes enclosing devices or utilization equipment supplied by 8, 6, or 4 AWG conductors must have a minimum internal depth of:

10 / 60

10. Luminaires, lampholders, and lamps must be installed so that ______.

11 / 60

11. What is the minimum clearance required in any direction to a diving platform for service-drop conductors operating at 20 kV to ground?

12 / 60

12. When cables enter or exit conduit used only for support or protection against physical damage, what is required at the end of the conduit?

13 / 60

13. The minimum size AWG conductor for a 30-amp circuit using copper conductors is:

14 / 60

14. What is the minimum size copper conductor permitted for feeders and branch circuits?

15 / 60

15. Service-entrance conductors entering or on the exterior of buildings must be insulated in accordance with which section?

16 / 60

16. True or False: Raceways embedded in masonry are not required to be arranged to drain.

17 / 60

17. What is the maximum receptacle rating permitted on a 20-amp branch circuit?

18 / 60

18. Can a multiwire branch circuit be considered multiple circuits?

19 / 60

19. What is the allowable ampacity of a 6 AWG copper conductor with 90°C insulation?

20 / 60

20. For circuits supplying loads consisting of motor-operated utilization equipment that is fastened in place and that has a motor larger than 1/8 horsepower in combination with other loads, the total calculated load shall be based on

21 / 60

21. Under what condition are dimmer controls permitted for interior stairway lighting outlets?

22 / 60

22. When calculating feeder loads, which value is used for the heating and cooling portion of the load?

23 / 60

23. Boxes enclosing devices or utilization equipment supplied by 14 AWG or smaller conductors must have a minimum internal depth of:

24 / 60

24. If multiple sets of service-entrance conductors supply a building, how is the size of the grounding electrode conductor determined?

25 / 60

25. Flexible cords are permitted to be installed in raceways:

26 / 60

26. When receptacles are installed in a crawl space at or below grade level, what type of protection is required?

27 / 60

27. Metal components of a concrete-encased electrode shall be encased by at least how many inches of concrete?

28 / 60

28. The point of attachment for overhead service conductors must be located not less than how many feet above finished grade?

29 / 60

29. Which of the following types of switches are not permitted to be reconditioned?

30 / 60

30. Which of the following mounting methods is not permitted for electrical equipment?

31 / 60

31. Where a required receptacle cannot be installed in the wall area directly above a countertop, what does the code allow?

32 / 60

32. What is the minimum conductor size (AWG) for a 20-amp branch circuit using copper conductors?

33 / 60

33. A recessed incandescent luminaire with a completely enclosed light source shall have a minimum clearance of:

34 / 60

34. The ampacity of conductors supplying multimotor and combination load equipment shall be not less than what value?

35 / 60

35. Which of the following luminaires installed directly over an indoor spa at less than 7 feet 6 inches above the maximum water level would be permitted if protected by a GFCI?

36 / 60

36. Color coding of switch connection conductors shall comply with which of the following?

37 / 60

37. A 15- or 20-ampere branch circuit shall be permitted to supply which of the following?

38 / 60

38. Which of the following insulation types is not permitted for individual current-carrying conductors under the IRC?

39 / 60

39. What demand factor applies to electric space-heating units where there are four or more separately controlled units?

40 / 60

40. If reconditioned equipment does not meet the listing or field labeling options specified in the code, the authority having jurisdiction (AHJ) is permitted to:

41 / 60

41. Receptacle assemblies and GFCI receptacle assemblies installed in countertop surfaces must be ______.

42 / 60

42. Branch circuits supplying utilization equipment over 1,440 volt-amperes or 1/4 horsepower and greater shall have a nominal voltage rating of

43 / 60

43. What is the minimum diameter of rebar for a concrete-encased electrode?

44 / 60

44. Service-entrance cable must be equipped with a service head or formed into what in an approved manner?

45 / 60

45. A copper grounding electrode conductor for service entrance conductors over 350 kcmil through 600 kcmil shall be no smaller than what size?

46 / 60

46. Flexible cords and cables are permitted to substitute for the fixed wiring of a structure.

47 / 60

47. What is the allowable ampacity of a 3 AWG copper conductor with 75°C insulation?

48 / 60

48. A service with two to six separate enclosures, each with a single main service disconnect, is:

49 / 60

49. What is the minimum short-circuit current rating service equipment must be suitable for?

50 / 60

50. Screwless conductor push-in terminals on snap switches shall be installed on branch circuits not greater than how many amperes?

51 / 60

51. In an indoor pool location, a luminaire is required to be provided with GFCI protection when installed 10 ft above the maximum water level of the pool.

52 / 60

52. A service with two to six separate panelboards, each with a single main service disconnect, is:

53 / 60

53. When flexibility is necessary after installation, what is the maximum distance in inches from a box or termination for 3-inch trade size Flexible Metal Conduit (FMC)?

54 / 60

54. What is the allowable ampacity of an 8 AWG aluminum conductor with 60°C insulation?

55 / 60

55. What is the minimum ampacity for ungrounded conductors in all other installations?

56 / 60

56. Which of the following is true regarding aluminum electrodes used as grounding electrodes?

57 / 60

57. When liquid-tight flexible metal conduit of trade size 1 inch is used as an equipment grounding conductor (EGC), the maximum rating of the overcurrent device protecting the circuit conductors contained within it shall not exceed:

58 / 60

58. What is the adjustment factor when more than 20 Type MC cables without an overall outer jacket are stacked or bundled longer than 24 inches without spacing, such as 25 cables?

59 / 60

59. Lampholders installed in damp locations must be:

60 / 60

60. Terminals of 15- and 20-ampere receptacles not marked CO/ALR shall be used with which conductors?