“This untimed practice quiz simulates the ICC exam format, giving you full exposure to real-style questions while allowing unlimited time to navigate, learn, and build confidence without time pressure.”

2024 Residential Plans Examiner (R3) (Untimed)

60 Questions

2 Hours

1 / 60

1. Each length of pipe, pipe fitting, trap, and fixture must bear what identification?

2 / 60

2. What is the maximum allowable span for a 2×12, #2 grade Douglas fir-larch rafter spaced 16 inches apart, with a dead load of 10 psf, ceiling attached, and a roof live load of 50 psf?

3 / 60

3. Plumbing fixtures, faucets, and fixture fittings must have smooth impervious surfaces, be free from defects, and meet which other criteria regarding surfaces?

4 / 60

4. Horizontal branches shall connect to the bases of stacks at a point located not less than how many times the diameter of the drainage stack downstream from the stack?

5 / 60

5. What is the minimum height of a guardrail required for decks more than 30 inches above grade?

6 / 60

6. In mechanically ventilated indoor locations for hydrogen-generating appliances, where must equipment with ignition sources be located?

7 / 60

7. Which of the following materials is approved for use in a condensate disposal system?

8 / 60

8. What is the minimum required guard height for a residential balcony?

9 / 60

9. If a space is provided for a clothes dryer but one is not yet installed, what must be done with the exhaust duct in that space?

10 / 60

10. Which of the following fixtures shall NOT be served by a combination waste and vent system?

11 / 60

11. For the Standard Reference Design (SRD) calculation, what solar reflectance and emittance values must be assigned to the roof?

12 / 60

12. What is the vertical reinforcement requirement for an 10-inch plain masonry foundation wall with 9 feet of unsupported wall height, 8 feet of unbalanced backfill, and ML soil?

13 / 60

13. What is the required slope of ground surfaces for site drainage away from a foundation?

14 / 60

14. The device that controls the operation of an electrically operated pool cover must be located so that the operator has which of the following?

15 / 60

15. The outlet of a drain valve installed on a tank-type water heater must be provided with what type of connection?

16 / 60

16. What is the minimum required trap size (diameter) for a clothes washer standpipe?

17 / 60

17. How is a conflict between a referenced code and the IRC resolved?

18 / 60

18. Duct systems must be constructed of materials having a flame spread index of no greater than:

19 / 60

19. Under wind pressures greater than 30 psf, vinyl exterior soffit panels must be fastened at both ends to which of the following?

20 / 60

20. How far must the galvanized metal tie extend beyond the opening when reinforcing a notched or drilled top plate?

21 / 60

21. Where is it prohibited to locate an exterior air intake for combustion air?

22 / 60

22. What is the minimum footing size (width × thickness in inches) required for a 3-story light-frame with brick veneer crawl space structure with a 50 psf roof live load and 2,000 psf soil bearing capacity?

23 / 60

23. Which backflow prevention device is permitted to be installed where subject to continuous pressure conditions but is prohibited if hazardous chemical additives are introduced downstream?

24 / 60

24. What standard must be used to verify the material identification of load-bearing cold-formed steel roof framing members?

25 / 60

25. Which statement is correct regarding the use of structural reinforcing steel for pools, spas, and hot tubs as a grounding electrode?

26 / 60

26. In soils other than Group I, what is the minimum required size of a sump used to drain the porous layer and footings in wood foundations?

27 / 60

27. Which of the following must be listed in accordance with UL 378 and locked into position before use?

28 / 60

28. What is the minimum required bearing length for deck beams on concrete or masonry?

29 / 60

29. What is the minimum required headroom for a stairway?

30 / 60

30. What is the required minimum net clear opening height for an emergency escape and rescue opening?

31 / 60

31. The disconnecting means for a motor-operated appliance rated over 1/8 horsepower shall have an ampere rating of not less than ____ of the motor’s full-load current rating, unless a listed unfused motor-circuit switch with a horsepower rating not less than the motor is used.

32 / 60

32. What is the allowable ampacity of a 10 AWG copper conductor with 75°C insulation?

33 / 60

33. If a building exceeds the applicability limits, which standard can be used for the design and construction of cold-formed steel wall framing?

34 / 60

34. What is the maximum allowable height difference between the threshold of an egress door and the landing inside?

35 / 60

35. When combustion air is supplied entirely by a mechanical system, what is the minimum required rate of outdoor air supply?

36 / 60

36. What must be provided for unsupported edges of sanded plywood combination subfloor underlayment when installed continuously over two or more spans?

37 / 60

37. What is the minimum required width for a stair landing?

38 / 60

38. What is the maximum spacing for intermediate balusters in a guard?

39 / 60

39. Service heads on raceways or service-entrance cables must be located above the point of attachment of the overhead conductors unless impracticable, in which case they may be no more than how many inches from the point of attachment?

40 / 60

40. In a dwelling unit laundry area, what is the minimum number of receptacle outlets required?

41 / 60

41. What modification is prohibited on the flanges and lips of load-bearing cold-formed steel roof framing members?

42 / 60

42. Access or egress from working space is considered impeded if simultaneously opened equipment doors reduce the working space width and height to less than:

43 / 60

43. What is the maximum overcurrent protection device rating for an 8 AWG aluminum conductor?

44 / 60

44. For asphalt shingle underlayment, how far must end laps be offset between courses?

45 / 60

45. Combustion air for solid fuel-burning appliances must be provided in accordance with:

46 / 60

46. What is the maximum allowed plan dimension for buildings constructed with exterior concrete walls under the IRC?

47 / 60

47. What is the minimum required egress width between two handrails for a stairway?

48 / 60

48. What is the minimum depth of a landing at the top and bottom of a stairway?

49 / 60

49. What is the minimum required ventilation area for under-floor spaces unless an exception applies?

50 / 60

50. The sump pump, sump, and discharge piping must conform to the requirements of which set of code specifications?

51 / 60

51. What is the minimum distance required between foundation anchor bolts?

52 / 60

52. Gas piping enclosed within framing members must be protected if located less than 1½ inches from the framing face unless what material is used?

53 / 60

53. A device capable of being operated by personal intervention is defined as what?

54 / 60

54. When an oil tank is abandoned or removed, what must be done with outdoor above-grade fill piping?

55 / 60

55. What is the required minimum headlap for slate shingles on a roof with a slope of 6:12?

56 / 60

56. What is the minimum required landing depth at an exterior door?

57 / 60

57. For single-wall metal pipe connectors measuring over 10 through 16 inches in diameter for oil or solid fuel-burning appliances, what gauge number is required?

58 / 60

58. What is the minimum nominal thickness required for wood structural panel exterior soffits?

59 / 60

59. When must truss design drawings be submitted to the building official for approval?

60 / 60

60. When service conductors serve 100 percent of the dwelling unit load, the load shall be computed in accordance with:

Your score is