Where standby power is connected to elevators, what must also be connected to the standby power source?
3003.1.4
A free-standing object mounted on a post or pylon shall not overhang that post or pylon more than 4 inches (102 mm) where the lowest point of the leading edge is more than 27 inches (686 mm) and less than what distance above the finished floor?
1003.3.2
Buildings housing special industrial processes requiring large areas and unusual building heights (e.g., rolling mills) shall be exempt from the building height, number of stories, and building area limitations specified in which sections?
503.1.1
For public-occupancy temporary structures, where controlled occupancy procedures are implemented due to expected snow, the ground snow load reduction factor is permitted to be modified to what value?
3103.6.1.1 Exception
What must cause each fire door assembly in the occupant evacuation elevator lobby smoke barrier to automatically close?
3008.6.3.2
Where drinking fountains are provided, one drinking fountain shall comply with the requirements for people who use a wheelchair and one shall comply with the requirements for:
1110.7.1
For each selected wind direction, the wind exposure of the building shall be determined for the two upwind sectors extending how many degrees either side of the selected wind direction?
1609.4.1
For buildings in coastal high-hazard areas and coastal A zones, electrical, mechanical and plumbing system components shall not be mounted on or penetrate through exterior walls that are designed to break away under:
1402.1
For a 10-foot container with a nominal height of 8.0 feet (Container Designation 1D), what is the Allowable Shear Value (PLF) for the side wall for wind or seismic loading?
Table 3114.8.5.3
Hearth extensions must extend not less than 16 inches (406 mm) in front of, and not less than what minimum distance beyond, each side of the fireplace opening?
2111.11
For BIPV roof coverings installed in a high wind area (V ≥ 130 mph), mechanically fastened underlayment must be fastened with corrosion-resistant fasteners in a grid pattern of not greater than 12 inches horizontally and vertically between side laps, with what spacing at side and end laps?
1507.1.1
An accessible route is not required to press boxes in bleachers that have a single point of entry from the bleachers, provided that the aggregate area of all press boxes for each playing field is not more than:
1104.3.2 Exception 1
Material other than foam plastic used as interior trim must have a minimum Class C flame spread and smoke-developed index when tested in accordance with:
806.6
Protruding objects are permitted to reduce the height of the ceiling for not more than what percentage of the ceiling area of a means of egress?
1003.3.1
When may the building official issue a temporary certificate of occupancy?
111.3
For interior trim made of foam plastic insulation, what index is not limited by Section 2603.3?
2603.3 Exception
The minimum mechanical exhaust ventilation rate required throughout portions of a Group H-5 fabrication area where HPM are used or stored is not less than:
415.11.1.6
In unvented attics in Climate Zones 5, 6, 7, and 8, any air-impermeable insulation shall be a Class II vapor retarder or shall have a Class II vapor retarder coating in direct contact with the:
1202.3 Item 4
Which of the following occupancy groups is NOT permitted within a covered or open mall building or anchor building utilizing the reduced open space exception?
402.2 Exception
What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group I-4 of Type VA construction?
Table 504.4
The basic wind speed, for use in the design of Risk Category III buildings and structures shall be obtained from which figure?
1609.3
In nonsprinklered buildings of Group I-3 occupancy, what is the required interior finish classification for corridors and enclosures for exit access stairways?
Table 803.13
What is the minimum thickness required for galvanized steel corner beads used in gypsum-protected structural steel columns with sheet steel column covers for fire-resistance ratings of 2 hours or less?
Figure 722.5.1(2) Note 2
Regarding the building official’s interpretations, policies, and procedures to clarify application, they shall not have the effect of:
104.2
Cast-in-place structural concrete internally reinforced with GFRP reinforcement is permitted only for structures assigned to which Seismic Design Category?
1901.2.1
Which of the following structures is specifically included in the Utility and Miscellaneous Group U classification?
312.1
In a Group I-2 care suite containing sleeping rooms, what is the maximum area permitted where an automatic smoke detection system is provided throughout the care suite?
407.4.4.6.1 Exception
Courts more than two stories in height shall be provided with a horizontal air intake at the bottom not less than how many square feet (m2) in area?
1205.3.2
What are the maximum thickness and maximum width limits for foam plastic used as interior trim?
2604.2.2
Perimeter ties in bearing wall structures shall be located within what maximum distance of the edge of each floor and roof?
1616.3.2.3
Exterior openings into the attic space for ventilation must have a least dimension not less than 1/16 inch (1.6 mm) and not more than what maximum least dimension?
1202.2.2
Walls and ceilings of spray rooms shall be constructed of noncombustible materials or the interior surface shall be completely covered with noncombustible materials, and what material is specifically prohibited from use?
416.2.1
For a fire service access elevator, what is the exception regarding its requirement to serve the top floor of a building?
3007.1 Exception 2
If end-jointed lumber is used in an assembly required to have a fire-resistance rating, what designation must be included in its grade mark?
2303.1.1.2
Exterior walls separating an exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from which side?
1009.7.2
For a structure to successfully meet in-situ load test requirements, within 24 hours after removal of the test load, the structure must have recovered not less than what minimum percentage of the maximum deflection?
1708.2.2 Item 2
Metal roof shingles shall not be installed on roof slopes below what minimum units vertical in 12 units horizontal?
1507.5.2
Where pictograms are provided as designations for toilet rooms and bathing rooms, the pictograms shall have visual characters, raised characters and braille complying with which standard?
1112.2
Structural concrete must conform to the durability requirements of ACI 318, except for concrete in basement walls of Group R-2 and R-3 occupancies not more than three stories above grade plane, where the specified compressive strength, must be not less than:
1904.1 Exception
Canopies under which fuels are dispensed at motor fuel-dispensing facilities shall have a clear, unobstructed height of not less than:
406.7.2
What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group R-2 of Type IVB construction?
Table 504.4
What is the minimum required fire-resistance rating in hours for the primary structural frame in a Type IIA building?
Table 601
On exterior stud walls, adhered masonry veneer shall be installed not less than 4 inches above the earth, or not less than 2 inches above paved areas, or not less than what minimum distance above exterior walking surfaces that are supported by the same foundation?
1404.11.1.3
When calculating the estimated value of work for a permit application, the valuation must include the total value of work, including materials and labor, and also include:
109.3
What is the required minimum fire-resistance rating for a smoke barrier?
709.3
Dry-stack masonry is prohibited in structures assigned to which Risk Category?
2114.2
During the demolition of a building with an existing standpipe, how far below the floor being demolished shall the standpipe not be demolished?
3311.2
What are the minimum nominal dimensions required for wood members used for perimeter blocking for horizontal gypsum panel product diaphragm ceilings?
2508.6.3
Structural observations must be provided for structures classified as Risk Category III or:
1704.6.1 Item 1
What is the maximum height or thickness of a marquee if it projects more than two-thirds of the distance from the lot line to the curb line?
3106.2
Existing footings or foundations that can be affected by any excavation shall be underpinned adequately or otherwise protected against settlement and what other type of movement?
3304.1.2
Lightning protection systems must be installed in accordance with NFPA 780 or which UL standard?
2703.2
The design and construction of cold-formed steel floor and roof decks and composite slabs of concrete and steel deck must be in accordance with which standard?
2208.1
Sections of exterior plastic veneer shall not exceed 300 square feet (27.9 m2) in area and shall be separated by not less than what minimum vertical distance?
2605.2
What hardware components are exempt from fire test requirements for elevator hoistway doors?
3002.1.2
Where rooms without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall have an area of not less than 8 percent of the interior room floor area, but not less than how many square feet?
1202.5.1.1
For braced wall panels in the first story of two-story structures using a Portal Frame with Hold-Downs (PFH) (Section 2308.10.5.2), what is the minimum required panel width?
2308.10.5.2
Shower compartments and walls above bathtubs with installed shower heads shall be finished with a smooth, nonabsorbent surface to a height not less than what minimum distance above the drain inlet?
1210.2.4
In recreational boating facilities, where the number of boat slips provided is 75, what is the minimum required number of accessible boat slips?
Table 1111.4.9.1
Fire-retardant-treated wood structural panels must be dried to a moisture content of what maximum percentage before use?
2303.2.9
If only one elevator is installed and standby power is required, how quickly must the elevator automatically transfer to standby power after failure of normal power?
3003.1.2
Flagpoles and similar structures located on rooftops shall not be required to be constructed of noncombustible materials and shall not be limited in:
1511.7.5
In Group E occupancies, an adult changing station is required where a room or space used for assembly purposes requires an aggregate of how many or more male and female water closets for that room or space?
1110.4.1 Item 3
According to Table 1705.3, inspecting the erection of precast concrete members requires which type of inspection?
Table 1705.3 Item 10
Where are laboratory suites specifically NOT permitted according to Table 428.3?
Table 428.3
Where a response modification coefficient, R, in accordance with ASCE 7, Table 12.2-1, is used for the design of cold-formed steel special bolted moment frames, the structures must be designed and detailed in accordance with the requirements of which standard?
2204.2.1
In the horizontal building separation allowance, the building or buildings above the horizontal assembly shall be of which Group occupancies?
510.2
Glass-block assemblies having a fire protection rating of not less than what minimum time shall be permitted as opening protectives in fire barriers, fire partitions, and smoke barriers that have a required fire-resistance rating of 1 hour or less?
2110.1.1 Exception
Play structures must comply with Section 424 if they exceed 10 feet (3048 mm) in height or what area?
424.1
According to Table 1610.1, what is the design lateral soil load for active pressure (psf per foot of depth) for Silty gravels (GM)?
1610.1
Engineering analysis to determine fire protection time for connections in fire-resistance-rated members must demonstrate that the average temperature rise at any portion of the connection is limited to what maximum value?
2304.10.1
A contrasting marking stripe shall be provided on each tread at the nosing or leading edge of a stepped aisle and shall be not less than 1 inch (25 mm) and not more than what maximum width?
1030.14.2.3
Where a standpipe is required in accordance with Section 3311, what is the maximum distance allowed between the fire hydrant used for the water supply and the fire department connection supplying the standpipe?
3313.4
At wide-flanged columns, thickness measurements of SFRM shall be made at how many locations around the column at each end of a 12-inch length?
1705.15.4.8
Gutters and leaders placed on the outside of buildings, other than Group R-3, private garages and buildings of Type V construction, shall be constructed of noncombustible material or:
1502.3
Where a standpipe is required in accordance with Section 3311, what is the required minimum flow of the water supply?
3313.4
Dwelling units and sleeping units required to be Accessible units, Type A units, or Type B units shall comply with the applicable portions of Chapter 11 of:
1108.2
Educational Group E occupancy includes the use of a building by six or more persons at any one time for educational purposes through which grade?
305.1
Not less than what percentage of vehicle spaces on the site served by electrical vehicle charging systems shall be accessible, but not fewer than one for each type of charging system?
1107.2.1
Ballasted low-slope single-ply roof system coverings shall be designed in accordance with which standard?
1504.5
Concrete foundations must be protected from freezing during depositing and for a period of not less than:
1808.8.4
For a Group I-3 occupancy, where the corridor serves all occupants, what is the required fire-resistance rating for the corridor walls in a sprinklered building?
Table 1020.2
Mortar for use with adhered masonry veneer must conform to which section of TMS 402?
2103.2.4
Where required, glazing shall be tested in accordance with CPSC 16 CFR Part 1201 and must comply with the test criteria for which Category, unless otherwise indicated in Table 2406.2(1)?
2406.2
What is the required interior wall and ceiling finish classification for rooms and enclosed spaces in a sprinklered Group R-2 occupancy?
Table 803.13
A building intended for unlimited area use (Section 507) has 90 percent of its perimeter fronting on an open space between 40 feet and less than 45 feet. What is the allowable Frontage Increase Factor?
Table 506.3.3.1
Glass in elevator car enclosures, glass elevator car doors, and glass used for lining walls and ceilings of elevator cars must be laminated glass conforming to Class A of ANSI Z97.1 or which Category of CPSC 16 CFR Part 1201?
2409.4.1
Unbalanced backfill height is the difference in height between the exterior finish ground level and the lower of the interior finish ground level or the:
1807.1.2
Where concrete and clay roof tiles do not satisfy the limitations in Chapter 16 for rigid tile, a wind tunnel test shall be used to determine the wind characteristics of the roof covering in accordance with SBCCI SSTD 11 or:
1504.3.1.2
A structure wherein the shape is attained by air pressure and occupants are within the elevated pressure area is defined as an:
202 [BG] Air-Supported Structure
According to Table 1806.2, what is the presumptive lateral bearing pressure (psf/ft below natural grade) for Sedimentary and foliated rock?
1806.2
Clearance between wood siding and earth on the exterior of a building shall be not less than:
2304.12.1.5
Which item, in addition to reports of special inspections, must the owner or authorized agent submit to the building official?
1704.5 Item 5
What is the required interior wall and ceiling finish classification for corridors and enclosures for exit access stairways in a nonsprinklered Group H occupancy?
Table 803.13
In Type IV-A construction, the interior faces of all mass timber elements must be protected with noncombustible protection contributing a minimum assigned time of not less than:
602.4.1.2.1
Special inspections shall not be required for EIFS applications installed over a water-resistive barrier with a means of draining moisture to the:
1705.17 Exception 1
For covered walkways serving new light-frame construction not exceeding two stories above grade plane (Exception to 3306.7), what is the maximum spacing permitted for posts that are not less than 4 inches by 6 inches?
3306.7 Exception
Emergency power systems provided for means of egress illumination must be capable of powering the required load for a duration of not less than how long?
2702.2.14
In high-rise buildings more than 420 feet (128 m) in height, not fewer than how many standpipes or sprinkler express risers shall supply automatic sprinkler systems within each vertical water supply zone?
403.3.1.2
In Group B and M occupancies, nonpublic aisles serving less than 50 people and not required to be accessible need not exceed what minimum width?
1018.3 Exception
Cleanout openings must be provided within what maximum distance of the base of each flue within every masonry chimney?
2113.18
Air-Impermeable Insulation must have an air permeance equal to or less than what value at 75 pa pressure differential?
202 [BF] Air-Impermeable Insulation
The 60-foot (18 288 mm) public ways or yards required for unlimited area buildings shall be permitted to be reduced to not less than 40 feet (12 192 mm) provided the reduced width is not allowed for more than what percentage of the building’s perimeter?
507.2.1
If a smoke-protective curtain assembly for hoistways is used for elevator hoistway door protection, which UL standard must the control unit be listed to?
3006.3
The test assembly for preconstruction load tests shall be subjected to an increasing superimposed load equal to not less than what factor multiplied by the superimposed design load?
1709.3.1
A passenger loading zone shall be provided at an accessible entrance to licensed medical and long-term care facilities where the period of stay exceeds:
1106.9.2
The landing at an exterior door serving Groups F, H, R-2, and S and where such doors are not part of an accessible route, shall not be more than what distance below the landing on the egress side?
1010.1.4 Exception 2
In buildings requiring an automatic sprinkler system, when is it unlawful to occupy any portion of the building?
3312.1
Where the difference in elevation is 6 inches (152 mm) or less in the means of egress, the ramp shall be equipped with either handrails or:
1003.5
A Basement is defined as a story that is not a:
202 [BG] Basement
To be permitted under Section 803.5.2, textile wall coverings must have a Class A flame spread index and be protected by:
803.5.2
When an automatic sprinkler system is provided in a covered mall building, the sprinkler protection for the mall shall be independent from that provided for:
402.5
Where anchored terra cotta or ceramic veneer units are tied to the backing wall, the space between the facing and the backing wall must be set with not less than a 2-inch space and the space must be filled solidly with:
1404.1
Class A roof assemblies include minimum 16 ounce per square foot copper sheets installed over:
1505.2 Exception 3
Where installed on exterior walls having a fire separation distance of 5 feet or less, combustible exterior wall coverings tested in accordance with NFPA 268 shall not exhibit:
1405.1.1.1.1
Exposed combustible trim or mantels can be placed directly on the masonry fireplace front surrounding the opening, provided such materials are not placed within what minimum distance of the fireplace opening?
2111.12 Exception 4
In under-floor spaces with uncovered earth floors, the net area of ventilation openings shall be not less than 1 square foot for each how many square feet of crawl space area?
1202.4.1.1
The combustion air passageway for masonry fireplaces shall be not less than 6 square inches (3870 mm2) and not more than what maximum area?
2111.14.5
Where seating or standing space is provided at fixed or built-in work surfaces, not less than what percentage of those spaces shall be accessible?
1110.14.2
Sanitary facilities must be provided during construction, remodeling or demolition activities in accordance with which code?
3305.1
In nursing homes (I-2, Condition 1), water closets and roll-in-type showers required to comply with ICC A117.1 are permitted to be substituted with alternate compliance provisions in not more than what percentage of the Accessible units?
1108.5.2.1 Exceptions
Standard calculations contained in ASTM D7158 assume Exposure Category B or C and a building height of what maximum distance or less?
1504.2
Under which six conditions is elevator hoistway door protection required in accordance with Section 3006.3?
3006.2
Where Section 1705.12 specifies special inspection for wind resistance, the statement of special inspections must identify the wind-resisting components and the:
1704.3.3
For smoke-protected assembly seating with a total number of seats of 10,000, what is the required capacity in inches per seat served for level aisles?
Table 1030.6.2
The exterior wall assembly utilizing foam plastic insulation in Type I, II, III, or IV construction must be tested for vertical and lateral fire propagation and must comply with the acceptance criteria of which standard?
2603.5.5
Where an elevator is installed in a single blind hoistway or on the outside of a building, what must be installed in the blind portion of the hoistway or blank face of the building?
3002.5
Where direct access for pedestrians is provided from parking structures to buildings, the entrance shall be accessible, as specified in which section?
1105.1.2
Risers shall be solid, EXCEPT that for stairways not required to comply with Section 1009.3, the opening between treads shall not permit the passage of a sphere with a diameter of what maximum size?
1011.5.5.3 Exception 1
What is the minimum required clearance in front of a water closet, urinal, lavatory, or bidet to any wall, fixture, or door?
2903.1.1
If a hoistway is required to be enclosed, how must it be constructed?
3002.1
Ambulatory care facilities must be separated from adjacent spaces where the potential for how many or more care recipients are to be incapable of self-preservation at any time?
422.2
In Anchorage/Eagle River, Alaska, at an elevation of 500 feet, what is the ground snow load in pounds per square foot required for a Risk Category II building, according to Table 1608.2?
1608.2
In court sports, at least how many accessible routes shall directly connect both sides of the court?
1111.4.4
What is the wind load reduction factor for a public-occupancy temporary structure in Risk Category II with a service life of 10 years?
Table 3103.6.1.2
When an escalator shutter begins to close, what operational requirement must be met?
712.1.3.2
For exterior walls of one-story buildings constructed of insulated metal panels (IMP) with foam plastic insulation cores, a thermal barrier is not required if the building is equipped throughout with an automatic sprinkler system and the foam plastic core thickness is not more than:
2603.4.1.4
An automatic sprinkler system is required for all enclosed Group A-5 accessory use areas in excess of:
903.2.1.5
Bulk shipments of roof-covering materials must be accompanied with the same product information issued in the form of a certificate or on a:
1506.3
What is the required interior wall and ceiling finish classification for corridors in a sprinklered Group I-2 occupancy?
Table 803.13
Exit sign placement shall be such that any point in an exit access corridor or exit passageway is within what maximum distance or the listed viewing distance of the sign, whichever is less, from the nearest visible exit sign?
1013.1
What international symbol must identify the elevator car provided for fire department emergency access?
3002.4
All lightning protection systems on a building or structure must be interconnected in accordance with NFPA 780 or which other standard, as applicable?
2703.3
The separation distance to exit access stairways shall be measured to the closest:
1007.1.1.1
In riverine flood hazard areas where design flood elevations are specified but floodways have not been designated, the proposed work shall not increase the design flood elevation more than what maximum distance?
1612.3.2
Which two occupancy types are generally exempt from Chapter 11 requirements for detached dwellings and their accessory structures?
1103.2.3
The minimum required bearing length on each end of the fireplace opening for a lintel of noncombustible material shall be:
2111.8
Emergency escape and rescue openings shall have a minimum net clear opening of:
1031.3.1
In exterior walls requiring a 2-hour fire-resistance rating, what is the minimum required fire window assembly rating?
Table 716.1(3)
What must happen to an elevator machine room, control room, or control space with openings into a pressurized hoistway upon activation of a heat or smoke detector?
3005.3
Nonstructural projections such as trim and similar decorative features are permitted to project into the required means of egress width not more than what distance on each side?
1005.7.2
Not fewer than one layer of water-resistive barrier material must be attached to the studs or sheathing, and its intersection with fenestration openings shall be flashed and assembled in accordance with the:
1403.2
Special inspection of cold-formed steel trusses over what minimum length must be in accordance with Section 1705.2?
2206.1.3.2
According to Table 716.1(1), the marking “W” on fire-rated glazing indicates that the assembly meets which criterion?
Table 716.1(1)
For the alternate method of application of cement plaster, what percentage of the weight of the Portland cement is permitted to be calcium aluminate cement added to the mix?
2512.8.1
For buildings with a mean roof height less than or equal to 30 feet, Exposure B shall apply where Surface Roughness B prevails in the upwind direction for a distance of not less than:
1609.4.3
In organic coatings manufacturing, storage areas for flammable and combustible liquid tanks inside structures shall be separated from the processing area by not less than:
418.4
Foam plastic up to 10 inches thick in cooler and freezer walls must be covered by corrosion-resistant steel having a minimum base metal thickness of not less than:
2603.4.1.2
The allowable compressive load on any driven deep foundation element determined by an approved driving formula shall not exceed:
1810.3.3.1.1
According to Table 1705.5.3, inspecting the erection of mass timber construction requires which type of inspection?
Table 1705.5.3 Item 2
Wood joists or structural floors that are closer than 18 inches to the exposed ground in crawl spaces, or wood girders that are closer than what minimum distance to the exposed ground, must be of naturally durable wood or preservative-treated wood?
2304.12.1.1
The path of egress travel to an exit shall not pass through more than how many adjacent stories?
1006.3.2
In Type IV-C construction, shafts and elevator hoistway enclosures shall be protected with noncombustible protection having a minimum assigned time of 40 minutes on both the inside of the shaft and the outside of the shaft, as specified in:
602.4.3.6
In vehicle and pedestrian traffic areas of motor-vehicle-related occupancies, the clear height of each floor level shall be not less than:
406.2.2
Metal lath and lath attachments used for cement plaster shall be of what type of material?
2510.4
In office buildings where partition locations are subject to change, the partition load shall be not less than a live load of:
1607.5
Periodic special inspection is required for fastening of wind-resisting components, including exterior wall covering and wall connections to roof and floor:
1705.12.3 Item 2
If a service entrance is the only entrance to a building or a tenant space in a facility, that entrance shall be:
1105.1.6
What is the minimum required vertical clearance from the public right-of-way to the lowest part of any awning (including valances) that projects into the right-of-way below 8 feet in height?
3202.2.3
Where serving technical production areas, the maximum common path of travel permitted where two means of egress are required is:
410.5.3.3
Guards with structural glass balusters must have an attached top rail or handrail supported by not fewer than how many glass balusters, or be otherwise supported to remain in place should one fail?
2407.1.2
For high-rise buildings greater than 420 feet (128 m) in height, the minimum bond strength required for Sprayed Fire-Resistive Materials (SFRM) installed throughout the building shall be:
Table 403.2.3
Combustible kiosks constructed of foam plastics located within a covered mall building shall have a maximum heat release rate not greater than:
402.6.2
Where a column extends through a ceiling and requires protection, the encasement must be continuous from the top of the foundation or floor/ceiling assembly below, through the ceiling space, to the:
704.2
The occupant load of seating booths shall be based on one person for each what minimum length of booth seat measured at the backrest?
1004.6
Fall arrest, lifeline, and rope descent system anchorages shall be designed for a live load of not less than what minimum force for each attached line, in any direction the load can be applied?
1607.12.4
How many exits or exit access doorways shall be provided from any space with an occupant load greater than 1,000?
1006.2.1.1
What is the required minimum fire separation distance (FSD) for an exterior wall projection to be permitted to extend to 24 inches (610 mm) from the line used to determine the FSD?
Table 705.2
According to Table 1507.7.6, what is the minimum required headlap (in inches) for slate shingles installed on a slope of 12:12?
1507.7.6
Under the Simplified Structural Design Procedure for single-unit containers, the intermodal shipping container must be located in which Seismic Design Categories?
3114.8.5.1
For glass walls in racquetball or squash courts, the deflection at the point of impact shall not be greater than 1 1/2 inches (38 mm) for a drop height of:
2408.2.1
According to Table 1806.2, what is the presumptive coefficient of friction for Sand, silty sand, clayey sand, silty gravel and clayey gravel (SW, SP, SM, SC, GM and GC)?
1806.2
Emergency power systems must automatically provide secondary power within what maximum time after primary power is lost, unless specified otherwise in this code?
2702.1.4
If a skylight is not rated separately for positive and negative pressure, the performance grade rating shown on the label shall be the rating determined in accordance with AAMA/WDMA/CSA 101/I.S.2/A440 for:
2405.5
Where dressing rooms, fitting rooms or locker rooms are provided, at least what percentage, but not less than one, of each type of use in each cluster provided shall be accessible?
1110.17
When designing lap splices using Equation 21-1, the length of the lapped splice, shall be not less than:
2107.2.1
According to Table 1808.8.2, what is the minimum concrete cover required for precast nonprestressed deep foundation elements exposed to seawater?
1808.8.2
Special inspections and tests for sprayed fire-resistive materials (SFRM) must be performed during construction with an additional visual inspection after the rough installation of electrical, mechanical, plumbing and:
1705.15
In windborne debris regions, glazing located within 30 feet of grade shall meet the requirements of which test of ASTM E1996?
1609.2
If all or portions of the profiled steel panel elements of an intermodal shipping container are considered the seismic force-resisting system, design and detailing must be in accordance with the AISI S100 and ASCE 7, Table 12.2-1 requirements for which type of steel system?
3114.8.4.2
When calculating the means of egress for the mall, the occupant load factor (OLF) is not required to be less than:
402.8.2.2
Doors through which occupants must pass to complete the exit path shall be identified by a low-location luminous emergency exit symbol complying with NFPA 170. The symbol shall be not less than what minimum height?
1025.2.6.1
What is the maximum number of dwelling units permitted on the second story above grade plane of a Group R-2 occupancy for a single exit to be permitted, provided the building is sprinklered?
Table 1006.3.3
Building-integrated photovoltaic (BIPV) systems used as exterior wall coverings or fenestration must be listed and labeled in accordance with UL 1703 or both:
1411.1
Where walls are set out or ceilings are dropped distances greater than 1 3/4 inches (44 mm) from a fire-resistance-rated surface, which class of interior finish material must be used?
803.15.2
Portable fire extinguishers must be provided at each stairway on all floor levels where what materials have accumulated?
3309.1
For anchor bolts attaching cold-formed steel track to concrete, the anchors must be embedded into concrete a minimum of:
1905.7.2 Exception 2.2
Light-transmitting plastic covers on solar collectors having noncombustible sides and bottoms are permitted on buildings not over three stories above grade plane or 9,000 square feet (836.1 m2) in total floor area, provided the cover does not exceed what maximum percentage of the roof area for CC1 materials?
2606.12
Periodic special inspection is required for the erection and fastening of exterior cladding, interior and exterior nonbearing walls and interior and exterior veneer in structures assigned to which Seismic Design Categories?
1705.13.5
For buildings designed using conventional light-frame construction, the maximum floor-to-floor height shall not exceed:
2308.2.2
For a sprinklered space in Group R-2 occupancy consisting of dwelling units, what is the maximum common path of egress travel distance permitted in feet?
Table 1006.2.1
Two exit access doorways are required in boiler, incinerator and furnace rooms where the area is over 500 square feet (46 m2) and any fuel-fired equipment exceeds what input capacity?
1006.2.2.1
Garage doors and rolling doors shall be labeled with a permanent label identifying the door manufacturer, the door model/series number, the positive and negative design wind pressure rating, the applicable test standard, and the:
1709.5.2.1
Where a lining of firebrick not less than 2 inches (51 mm) thick is provided in a masonry firebox, the minimum thickness of back and sidewalls, including the lining, shall each be:
2111.6
What type of standby power must serve the fire service access elevator equipment, hoistway lighting, ventilation and cooling equipment, and car lighting?
3007.8
According to Table 1404.3(4), in Climate Zone 8, what is the minimum R-value of continuous insulation required over a 2×4 wall for use with a Class I or II responsive vapor retarder?
1404.3
Roof coverings installed on low-slope roofs shall resist impact damage based on the results of tests conducted in accordance with ASTM D3746, ASTM D4272 or:
1504.7
The firebox of a concrete or masonry fireplace shall have a minimum depth of:
2111.7
Where the design wind pressure is 30 pounds per square foot or less, hardboard soffit panels are permitted to be attached to wood framing with siding nails spaced not more than 6 inches on center at panel edges and not more than what maximum distance on center at intermediate supports?
1412.5
Exterior adhered porcelain tile units weighing more than 3.5 pounds per square foot shall not exceed 48 inches in any face dimension nor more than what maximum area in total face area?
1404.11.2
The concentrated live load given in Table 1607.1 shall be assumed to be uniformly distributed over an area of:
1607.4
Swimming pools and tennis courts intended for viewing indoor sporting events and activities with spectator seating are classified as which Assembly Group?
303.5
Special inspections and tests for intumescent fire-resistive materials applied to structural elements and decks shall be performed in accordance with which standard?
1705.16
The bedding coat for exterior surfaces of exposed aggregate plaster shall have a minimum compressive strength of:
2513.3
To qualify for an area factor increase based on frontage, a building shall have not less than what minimum percentage of its perimeter on a public way or open space?
506.3.1
Can the automatic means used to disconnect the main line power supply to an elevator due to sprinkler activation be self-resetting?
3005.5
When the building official issues a permit, how shall the construction documents be formally designated?
107.3.1
Fractional numbers resulting from applying the fixture ratios of Table 2902.1 shall be handled by rounding how?
2902.1.1
What is the tabular allowable area factor (At) for a nonsprinklered (NS) Group A-4 occupancy of Type VA construction?
Table 506.2
For posts embedded in earth and not embedded in poured footings, backfill in the annular space is permitted to be clean sand, thoroughly compacted by tamping in layers not more than what maximum depth?
1807.3.3 Item 2
Where nonseparated occupancies occur in a high-rise building, the most restrictive requirements of which section shall apply throughout the high-rise building?
508.3.1.1
In aircraft manufacturing facilities of Type I or II construction, for a height of 100 feet (30 480 mm) or more and a manufacturing area of 1,000,000 square feet (92 900 m2) or more, what is the maximum exit access travel distance permitted?
Table 412.6
Hydrogen fuel gas rooms not classified as Group H shall be provided with a ventilation system designed to maintain the room at a negative pressure in relation to:
421.3.1
Light-transmitting plastics classified as Class CC2 must have a burning rate of what maximum speed when tested in accordance with ASTM D635?
2606.4
The exit access travel distance in temporary structures shall be what maximum distance?
3103.4
In a high-rise building where stairway doors are locked, a telephone or other two-way communication system connected to an approved constantly attended station shall be provided at not less than every:
403.5.3.1
Where dining surfaces are provided, at least what percentage, but not less than one, of the dining surfaces for seating and standing spaces shall be accessible?
1109.2.9.1
Vertical sandblasted glass (sloped 15 degrees or less from vertical) is designed to resist wind loads based on the nonfactored load (Fge) for what level of sandblasting?
2404.3.5
For fireplaces with chimneys greater than 40 inches (1016 mm) wide, how many additional No. 4 vertical bars must be provided for each additional 40 inches (1016 mm) in width or fraction thereof?
2111.4.1
Structural observations must meet the applicable requirements of this section, in addition to special inspections and tests, statements of special inspections, responsibilities of contractors, and submittals to the:
1704.1
In structures with four or more dwelling units or sleeping units intended to be occupied as a residence, every unit intended to be occupied as a residence shall be a Type B unit for which occupancy group?
1108.5.1.3, 1108.6.1.2, 1108.6.2.2.2, 1108.6.2.3.2, 1108.6.3.2, 1108.6.4.2
According to Table 1807.1.6.3(4) for 12-inch nominal masonry walls (11.63 inches actual thickness), what is the minimum vertical reinforcement required for a 10-foot maximum wall height, 8-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft?
1807.1.6.3
For vegetative and landscaped roofs, the weight of landscaping and hardscaping materials shall be computed considering both fully saturated soil and drainage layer materials and fully dry soil and drainage layer materials in order to determine the:
1606.5
An elevator is required as part of the accessible means of egress where a required accessible floor is how many or more stories above or below a level of exit discharge?
1009.2.1
The required fire-resistance rating in hours for a fire barrier separating a single occupancy into fire areas for Group F-1, H-3, or S-1 is:
Table 707.3.10
A Compressed Gas must be a gas at 68°F (20°C) or less at 14.7 psia (101 kPa) of pressure and have a boiling point of 68°F (20°C) or less at 14.7 psia (101 kPa), except those gases with no other health- or physical-hazard properties are not considered compressed until the pressure in the packaging exceeds:
202 [F] Compressed Gas
In buildings of Type I or II construction for special industrial occupancies, the aggregate area of mezzanines shall be not greater than what fraction of the floor area of the room?
505.2.1 Exception 1
Concrete shall not be placed through water unless a tremie or other method is used that is:
1808.8.3
For a motion picture projection room used for a single machine, the minimum required floor area is:
409.2
The design of cold-formed steel diaphragms must be in accordance with additional provisions of which standard, as applicable?
2204.1
Walls required to be waterproofed shall be of concrete or masonry and waterproofing shall be applied from the bottom of the wall to not less than what minimum distance above the maximum elevation of the ground-water table?
1805.3.2
Fiber-cement siding must conform to the requirements of ASTM C1186, Type A, or:
1403.9
Emergency power systems and standby power systems required by this code or the International Fire Code must be installed in accordance with the International Fire Code, NFPA 70, NFPA 110, and which other NFPA standard?
2702.1.3
What is the Tabular allowable area factor in square feet for a building classified as Group A-1, one story above grade plane (S1) of Type VB construction?
Table 506.2
The NS (nonsprinklered) value in Table 504.3 is provided solely for use in the evaluation of existing building height in accordance with the:
Table 504.3 Footnotes
Special inspections and nondestructive testing of structural stainless steel elements shall be in accordance with the quality assurance inspection requirements of which standard?
1705.2.2
In attics or crawl spaces where entry is only for service of utilities, what is the minimum thickness of gypsum wallboard required to protect foam plastic insulation against ignition?
2603.4.1.6
When is the elevator emergency sign (instructing occupants to use the exit stairways) not required?
3002.3 Exception
Theaters intended for the production and viewing of the performing arts or motion pictures, usually with fixed seating, are classified as which Assembly Group?
303.2
Piping, fixtures, or equipment shall not be located in such a manner as to interfere with the normal operation of which three types of egress openings?
2903.1.3
According to Table 722.2.2.1, what is the minimum required slab thickness in inches for a 3-hour fire-resistance rating when using lightweight concrete?
Table 722.2.2.1
The maximum number of residents permitted in any single smoke compartment in a Group I-3 occupancy is:
408.6.1
Where a building or portion of a building is required to be accessible, at least one accessible route shall be provided to each portion of the building, to accessible building entrances connecting accessible pedestrian walkways and to the:
1104.3
Compartmentation is required for an underground building having a floor level more than what depth below the finished floor of the lowest level of exit discharge?
405.4.1
Where elevators are provided in buildings four or more stories above or four or more stories below grade plane, what is the minimum size of the ambulance stretcher that at least one elevator car must be able to accommodate?
3002.4
Special inspections for seismic resistance are not required for reinforced masonry or reinforced concrete structures where the design spectral response acceleration at short periods, does not exceed 0.5 and the building height does not exceed:
1705.13 Exception 2
Spaces under grandstands or bleachers used for accessory use areas (other than ticket booths or toilet rooms) are limited to 1,000 square feet (92.9 m2) or less in area and must be equipped with an automatic sprinkler system in accordance with:
1030.1.1.1 Exception 3
When tested in accordance with NFPA 286, the peak heat release rate of an interior finish shall not exceed:
803.1.1.1
If a building is equipped throughout with an automatic sprinkler system and Class I materials are required, which materials are permitted instead?
804.4.2 Exception
What minimum fire protection rating is required for each doorway in the smoke barrier separating the occupant evacuation elevator lobby?
3008.6.3
Each private garage shall be classified as a Group U occupancy and shall be not greater than what area?
406.3.1
Reflective plastic core insulation shall have a flame spread index of not more than 25 and a smoke-developed index of not more than 450 when tested in accordance with ASTM E84 or UL 723, and test specimen preparation and mounting must be in accordance with which ASTM standard?
2614.3
According to Table 1705.2.4, is continuous or periodic special inspection required for the installation of end connections (welding or bolted) of open-web steel joists?
Table 1705.2.4 Item 1.a
Gypsum wallboard, gypsum lath, or gypsum plaster shall not be installed until what condition is met?
2508.2.1
What is the maximum size permitted for a glass bottle designed and intended to dispense an aerosol?
202 [F] Aerosol Container
When labeling a product, the approved agency must maintain a record of tests performed that provides sufficient detail to verify compliance with the:
1703.5.1
For a Group R occupancy, where the corridor serves an occupant load greater than 10, what is the required fire-resistance rating for the corridor walls in a sprinklered building?
Table 1020.2
The area of covered and open mall buildings and anchor buildings not exceeding three stories in height that comply with Section 402 shall be:
507.13
Masonry chimneys must have a concrete, metal, or stone cap, sloped to shed water, a drip edge, and a caulked bond break around any flue liners in accordance with which ASTM standard?
2113.9.1
If a building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the maximum allowable quantities of certain hazardous materials (per Note d) shall be increased by what percentage?
Table 307.1(1) Note d
Rooftop mounted photovoltaic (PV) panel systems shall be tested, listed and identified with a fire classification in accordance with which UL standard?
1505.9
A building or tenant space used for assembly purposes with an occupant load of less than 50 persons shall be classified as which occupancy group?
303.1.1
On a site with multiple nonelevator buildings, the required number of Type B units may be reduced to a percentage equal to the percentage of the entire site having grades, prior to development, that are less than 10 percent, provided that not less than what percentage of the required Type B units on the site are still provided?
1108.7.4 Item 1
Where an exterior wall is not required to be fire-resistance rated based on fire separation distance, an exterior wall parapet is:
705.12 Exception 1
Computations to determine the required sizes of wood structural members must be based on which dimensions?
2304.2
What is the maximum distance columns or pilasters (including bases and moldings) are permitted to project into the public right-of-way below 8 feet in height?
3202.2.2
Metal flashing to which bituminous materials are to be adhered during reconstruction must be treated how prior to installation?
1512.5
Which standard applies to the material for Glass mat gypsum backing panel?
Table 2506.2
For roof structures that support photovoltaic panel systems, roof live loads need not be applied to the area covered by the panels where the clear space between the panels and the roof surface is:
1607.22.1
Any person who commences work before obtaining necessary permits shall be subject to a fee established by the building official that shall be:
109.4
What minimum duration must the standby power for an auxiliary inflation system be capable of operating independently?
3102.8.2
In Group I-1, Condition 2 occupancies, at least what percentage, but not less than one, of the dwelling units and sleeping units shall be Accessible units?
1108.5.1.2
According to Table 1412.6, for a wood structural panel soffit (3/8 minimum performance category) with a maximum design pressure of ± 50 psf, what is the maximum fastener spacing permitted for galvanized steel along edges and intermediate supports when using a 6d box nail?
1412.6
Aggregate accessory occupancies shall not occupy more than what percentage of the floor area of the story in which they are located?
508.2.3
Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place, and what materials/conditions must generally be satisfied?
110.3.1
The design, testing, and utilization of steel cantilevered storage racks made of cold-formed or hot-rolled steel structural members must be in accordance with which standard?
2209.1
Foundation walls extending not more than 8 feet below grade and laterally supported at the top by flexible diaphragms are permitted to be designed for what type of lateral soil pressure?
1610.1 Exception
What is the maximum allowable building height in feet for a nonsprinklered (NS) Group E occupancy of Type IIA construction?
Table 504.3
Broken glass retention screens, where required for sloped glazing, shall be capable of supporting what minimum factor multiplied by the weight of the glazing?
2405.3
What is the minimum corridor width (in inches) required in Group I-2 in areas where required for bed movement?
Table 1020.2
For Institutional occupancies classified as “Prisons,” what is the required ratio for showers?
Table 2902.1
The perimeter of a raised-deck system installed above a roof assembly shall be surrounded on all sides by walls or by a noncombustible enclosure approved to prevent fire intrusion and which shall extend at least from the roof assembly to the:
1511.9.1 Item 1
Combustible framing must be not less than 2 inches from flues, chimneys, and fireplaces, and not less than what minimum distance away from flue openings?
2304.5
Emergency power for power-operated doors and locks in Group I-3 occupancies is required by which section?
2702.2.9
Where means of egress from stories above and below converge at an intermediate level, the capacity from the point of convergence shall be not less than the largest minimum width or the sum of the required capacities for the stairways or ramps serving the two adjacent stories, whichever is:
1005.6
Special inspections are not required for cold-formed steel light-frame shear walls where the sheathing is:
1705.13.3 Exception 1
When a geotechnical report is required, it must be submitted to the building official by the permit applicant at the time of:
1803.6
Slate shingles shall only be used on slopes of what minimum units vertical in 12 units horizontal?
1507.7.2
A curb used for edge protection on a ramp run or landing shall be not less than what minimum height?
1012.10.1
For a furnace room incidental use, where the largest piece of equipment is over 400,000 Btu per hour input, what is the required separation and/or protection?
Table 509.1
The design, testing, and utilization of industrial boltless steel shelving must be in accordance with which standard?
2211.1
The vertical leg of drip edges for shingle roofs shall be not less than 11/2 inches in width and shall extend not less than 1/4 inch below sheathing, and the drip edge shall extend back on the roof not less than:
1507.2.8.3
An approved agency must have adequate equipment to perform required tests, and this equipment must be:
1703.1.2
A radiant barrier installed above a deck shall comply with which ASTM standard?
1510.4
The board of appeals shall not have the authority to:
113.2
In required exits or corridors, the area of approved light-transmitting plastic materials used in electrical luminaires shall not exceed what maximum percentage of the aggregate area of the ceiling?
2606.7.5
The specified compressive strength of concrete used for tie beams in adobe construction must be not less than:
2109.2.4.7.1
A fire-resistant pipe-protection system used for generator fuel lines in a high-rise building must have a minimum fire-resistance rating of not less than 2 hours, unless the building is protected throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1, in which case the required rating is reduced to what minimum duration?
2702.1.2
Fuel lines supplying a generator set inside a high-rise building must be separated from other areas of the building by one of three approved methods, including a fire-resistant pipe-protection system tested in accordance with which UL standard?
2702.1.2
Each portion of a building separated by one or more fire walls complying with Section 706 shall be considered to be a separate building for the purpose of determining which of the following?
503.1
According to Table 2304.8(3), for wood structural panel sheathing rated 24/16 and 7/16-inch thick, what is the maximum span permitted (in inches) when edge support is provided?
2304.8(3)
Except for tempered spandrel glass, the permanent identification mark on tempered glass shall be of a type that, once applied, cannot be removed without being:
2403.1
An alternative material, design, or method of construction must be not less than the equivalent of that prescribed in this code with respect to effectiveness, durability, and safety. What other factor is listed as an equivalency criterion?
104.2.3.4
A pipe or outlet, fitted with a suitable quick-opening valve for discharging the contents of a roof tank in an emergency, shall be provided in the bottom or on the side near the:
1511.3.1
Foam plastic in plenums used as interior wall or ceiling finish, or interior trim, must exhibit a flame spread index of 25 or less and a smoke-developed index of 50 or less when tested in accordance with ASTM E84 or UL 723, and shall also be tested in accordance with NFPA 286 and meet the acceptance criteria of which section?
2603.7
Where storm shelters are located outside the building they serve, the distance of travel from the exterior door of the building to a door of the shelter shall not exceed:
423.4.2
Standby power for auxiliary inflation systems in permanent membrane structures shall be provided for a duration of not less than how long?
2702.2.15
Structural tolerances for precast concrete structural elements must be in accordance with which standard?
1901.7.2
The required fire-resistance rating of exterior walls with a fire separation distance of less than or equal to 10 feet (3048 mm) shall be rated for exposure to fire from:
705.5
For steel storage racks that are 8 feet (2438 mm) in height or greater to the top load level and assigned to Seismic Design Category D, E, or F, what document must be submitted at the completion of installation?
2209.3
Fire walls and their supports shall be designed to withstand a minimum horizontal allowable stress load of 5 psf in order to meet the structural stability requirements of:
1607.16.2
The airspace between a masonry chimney and combustibles must not be filled, except to provide fireblocking in accordance with:
2113.19
What type of plaster is permitted to be applied to interior cement plaster base coats after a 48-hour period?
Table 2512.6 Note c
The floor base and foundation perimeter drain must discharge by gravity or mechanical means into an approved drainage system that complies with the:
1805.4.3
Thickness testing of SFRM applied to structural members must be performed on not less than what minimum percentage of the structural members on each floor?
1705.15.4.5
Fire-resistance-rated assemblies tested under ASTM E119 or UL 263 shall not be considered restrained unless evidence satisfactory to the building official is furnished showing that the construction qualifies for a restrained classification in accordance with:
703.2.1.3
If an occupant evacuation elevator lobby serves more than one elevator, what is the minimum number of elevators required to open into that lobby?
3008.1.1
Underpinning must be installed in a sequential manner that protects the neighboring structure and the working construction site, and the sequence of installation must be identified in the:
1804.2.1
Fire-retardant-treated wood roof coverings shall be tested in accordance with ASTM E108 or UL 790 and additionally in accordance with:
1505.1
For Higher education laboratories, what is the required fire-resistance rating for fire barriers separating a laboratory suite located on the third floor above grade plane from other portions of the building?
Table 428.3
Where a covered or open mall building utilizes the reduced open space exception (40 feet), for what maximum percentage of the perimeter is the reduction allowed?
402.2 Exception
In stories containing Group A-1 occupancies, an automatic sprinkler system is required where the fire area exceeds 12,000 square feet (1115 m2), or the fire area has an occupant load of:
903.2.1.1
In determining the fire-resistance rating of exterior bearing walls, compliance with the ASTM E119 criteria for unexposed surface temperature rise and ignition of cotton waste is required only for a period corresponding to the required rating of an:
703.2.1.5
The fireblocking of spaces between wood joists, beams, or headers in fireplaces must be to a depth of 1 inch (25 mm) and placed only on strips of metal or metal lath laid across the spaces between combustible material and the:
2111.13
Where separate central holding cells are provided for adult males, juvenile males, adult females or juvenile females, how many of each type shall be accessible?
1109.4.2.1
For exterior adhered masonry veneer installed with lath and mortar, the masonry veneer units shall be adhered to the scratch coat with a setting bed applied to create a full setting bed for the back of the masonry veneer units, resulting in a nominal:
1404.11.1.4.3
Flashing shall be installed at the perimeters of exterior door and window assemblies, penetrations, and terminations of exterior wall assemblies, exterior wall intersections with roofs, chimneys, porches, decks, balconies, and:
1404.4
For a Type IIA constructed aircraft hangar with a maximum single fire area of 20,000 square feet (1858 m2), what is the minimum required hangar classification for the fire suppression system?
Table 412.3.6
What is the minimum design live load required for walkways provided for pedestrian travel?
3306.2
Standby power systems must automatically provide secondary power within what maximum time after primary power is lost, unless specified otherwise in this code?
2702.1.4
Periodic special inspection is required for nailing, bolting, anchoring and other fastening of elements of the seismic force-resisting system, including wood shear walls, wood diaphragms, drag struts, braces, shear panels and:
1705.13.2 Item 2
In an efficiency dwelling unit (other than Accessible, Type A, or Type B units), the kitchen sink, cooking appliance and refrigerator must each have a clear working space of not less than what minimum distance in front?
1208.5 Item 3
A building, room or space used for assembly purposes with fixed seating with a seating capacity of 501 to 5,000 requires 6 wheelchair spaces, plus one for each how many seats, or fraction thereof, between 501 through 5,000?
Table 1109.2.2.1
For plain concrete footings supporting walls in Seismic Design Category C, D, E or F, the footings must have not fewer than two continuous longitudinal reinforcing bars that are not smaller than:
1905.6.2 Item 3
Incidental uses are limited to those uses specified in which table?
509.1
What is the minimum clear width required for escalators provided in below-grade transportation stations?
3004.2.2
To be classified as Class B material under ASTM E84 or UL 723 testing, an interior wall and ceiling finish must have a flame spread index (FSI) in what range?
803.1.2
The design, detailing, fabrication, and erection of structural steel elements in seismic force-resisting systems must be in accordance with AISC 341 where a response modification coefficient, R, greater than what minimum value in accordance with ASCE 7, Table 12.2-1, is used for the design of the structure assigned to Seismic Design Category B or C?
2202.2.2 Item 2
For any approved product, material, or assembly, a record of approval, including the conditions and limitations, shall be kept on file in the building official’s office and must be available for:
1703.3
Employee work areas less than 300 square feet (30 m2) in area that are located 7 inches (178 mm) or more above or below the ground or finished floor are exempt from all accessibility requirements, provided the change in elevation is:
1103.2.2
For exposed aggregate plaster, the aggregate used shall consist of marble chips, pebbles, or similar durable, moderately hard, nonreactive materials with a minimum Mohs hardness scale rating of:
2513.2
Where interior exit stairways or ramps are interconnected by a 1-hour fire-resistance-rated corridor, the required exit separation distance is permitted to be measured along the shortest direct line of travel within the:
1007.1.1 Exception 1
Access doors for automatic sprinkler system riser rooms and fire pump rooms must be labeled with an approved sign having letters of a minimum height of 2 inches (51 mm) and a minimum stroke of:
902.1.2
Special inspections for wind resistance are required for buildings in wind Exposure Category B where basic wind speed, is what minimum speed?
1705.12 Item 1
Rubble stone shall not be used for foundation walls of structures assigned to which Seismic Design Category or greater?
1807.1.3
According to Table 1404.2, what is the minimum nominal thickness required for adhered masonry veneer?
1404.2
In Group I-2 nursing homes (Condition 1), at least what percentage, but not less than one of each type of the dwelling units and sleeping units shall be Accessible units?
1108.5.2.1
Above-deck thermal insulation shall be permitted provided that such insulation is covered with an approved roof covering and passes the tests of UL 1256 or:
1508.1
Footings for masonry chimneys must extend not less than what minimum distance beyond the face of the foundation or support wall on all sides?
2113.2
What is the minimum clearance required to the lowest portion of the hood or awning for temporary entrance awnings?
3202.4
Ground-mounted photovoltaic (PV) panel systems serving only Group R-3 buildings shall be assigned to which risk category?
1604.5.2
For the alternative separation method using glass, the glass must be protected by an automatic sprinkler system that, when actuated, shall completely wet what area?
3104.5.2.2
What is the term for a wall or surface to which the veneer is secured?
202 [BF] Backing
According to Table 1705.3, what specific action requires continuous special inspection for the welding of reinforcement?
Table 1705.3 Item 2.b
If two or more elevators are controlled by a common operating system, and the standby power source is not of sufficient capacity to operate all elevators at the same time, what must happen after all elevators have returned to the designated level?
3003.1.3
In recreational boating facilities, where the total number of boat slips provided is 1,500, what is the minimum required number of accessible boat slips?
Table 1111.4.9.1
What is the required minimum thickness for an Artificial Barricade designed to shield from explosive materials?
202 [F] Artificial Barricade
Mechanical-access enclosed parking garages shall be separated from other occupancies and accessory uses by not less than:
406.6.4.1
When plastering with cement plaster over metal lath, wire fabric lath, or gypsum board backing for exterior application, how many coats minimum must be applied?
2512.1
In corridors and smoke barriers, a 20-minute fire door assembly required to have a minimum fire protection rating of 20 minutes shall be tested in accordance with NFPA 252 or UL 10C without which test?
716.2.2.1
In two-story, unlimited area buildings, Group H occupancies shall not be located more than one story above grade plane unless permitted by Section 504 height and story limits, and which condition is also required?
507.8.4
In a Two-Span Continuous Pattern for lumber decking, how many supports must all pieces be supported by?
2304.9.2.2
What is the minimum interior finish classification required for lobby areas in Group A-1, A-2, and A-3 occupancies?
Table 803.13 Note e
In Types I and II construction, sloped glazing and skylight frames must be constructed of:
2405.4
Special inspections of compacted fill must be in accordance with which specific section?
3304.1.4
For Group R occupancies, what is the required separation for a hydrogen fuel gas room not classified as Group H?
Table 509.1
For machine rooms, machinery spaces, control rooms, and control spaces that do not abut and do not have openings to the hoistway enclosure they serve, what is the permitted fire-resistance rating reduction for other than fire service access elevators and occupant evacuation elevators?
3005.4 Exception 1
Any fire protection or life safety system installed but not required by this code must still meet the requirements of this code, provided that such system is installed for:
901.2 Exception
The deflection of a blocked wood structural panel diaphragm uniformly fastened throughout with staples is permitted to be calculated using Equation 23-1, where the constant in the third term is:
2305.2
Seismic anchorage for masonry fireplaces is not required where the masonry fireplace is constructed completely within the:
2111.5 Exception
When indicating special requirements on construction documents for steel joists, which of the following is listed as a special load?
2207.2 Item 1.5
A building, room, or space used for assembly purposes that has an occupant load of greater than 300 must be provided with a main exit that is of sufficient capacity to accommodate not less than what fraction of the occupant load?
1030.2
A permit for temporary structures, equipment, or systems shall be limited as to time of service, but shall not be permitted for more than:
108.1
Equipment and appliances having an ignition source and located in a private garage must be elevated such that the source of ignition is not less than what distance above the floor surface?
406.2.9.1
What is the required separation and protection for incinerator rooms classified as an incidental use?
Table 509.1
BIPV shingles shall be listed and labeled in accordance with which UL standard?
1507.16.6
Where more than the minimum number of drinking fountains is provided, what percentage of the total number provided shall comply with the requirements for persons who use a wheelchair?
1110.7.2
For roof live load reduction factor, the value is 1 for a tributary area less than or equal to:
1607.14.1
Where more than three washing machines are provided in accessible spaces, not fewer than how many shall be accessible?
1110.6.1
Where elevator hoistway door protection is required, what is the height measurement requirement for a high rise hoistway?
3006.2
Are elevators permitted in a common shaft enclosure with a stairway?
3002.7
For sensor release of electrically locked egress doors, the manual unlocking device must be clearly identified by a sign that reads:
1010.2.11
Raised areas used primarily for purposes of security, life safety, or fire safety are generally exempt from Chapter 11 requirements, including, but not limited to:
1103.2.6
For plain concrete footings supporting walls that exceed 8 inches in thickness in Seismic Design Category C, D, E or F, not fewer than how many bars must be provided at the top and bottom of the footing?
1905.6.2 Item 3
The edge thickness of plain concrete footings supporting walls of other than light-frame construction shall be not less than:
1809.8
Every required interior exit stairway serving floors more than what height above the lowest level of fire department vehicle access shall be a smokeproof enclosure?
403.5.4
As a general rule, gypsum lath or gypsum wallboard shall not be used as a backing for cement plaster. What is one exception where its use is permitted with a water-resistive barrier and self-furred metal lath or self-furred wire fabric lath?
2510.5.2.1
A Class II interior floor finish material must have a minimum critical radiant flux of:
804.2
According to Table 1504.2, for a maximum allowable stress design wind speed (Vasd) of 90 mph, what is the required ASTM D3161 or UL 7103 classification for steep slope roof shingles?
1504.2
The quality assurance program for masonry construction must comply with the inspection and testing requirements of Chapter 17 and which standard?
2105.1
When tested in accordance with NFPA 286, the total smoke released by the interior finish throughout the test shall not exceed:
803.1.1.1
The allowable compressive stress based on the gross cross-sectional area of adobe shall not exceed:
2109.2.3
For high-pressure decorative exterior-grade compact laminates (HPL) installed on buildings of Types I, II, III and IV construction, the HPL must have a flame spread index of not more than:
1408.10.1
In Group I-2 occupancies, stories shall be divided into smoke compartments with an area of not more than:
407.5.1
The minimum vertical distance from top to top of two successive tiers of beams or finished floor surfaces used to measure a Story is defined as:
202 [BG] Story
Decreases in wind loads shall not be made for the effect of:
1609.1
Where a building is equipped throughout with an automatic sprinkler system, the required separation distance between exits shall be not less than what fraction of the length of the maximum overall diagonal dimension of the area served?
1007.1.1 Exception 2
What is the required interior wall and ceiling finish classification for corridors in a nonsprinklered Group B occupancy?
Table 803.13
Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than:
406.3.2.1
Where accessible parking is provided, how many accessible spaces are required for a parking facility providing 750 total parking spaces?
Table 1106.2
For basic uniform live load reduction, the reduced design live load shall be not less than 0.40 L for members supporting how many floors?
1607.13.1
In Group I-3 occupancies in buildings less than three stories above grade plane, which classification of interior finish is permitted in interior exit stairways for nonsprinklered buildings?
Table 803.13 Note b
A polyethylene vapor retarder placed between the base course or subgrade and the concrete floor slab must be 6-mil minimum thickness with joints lapped not less than:
1907.4
What must dwelling units complying with the air leakage requirements of the International Energy Conservation Code or ASHRAE 90.1 be ventilated by?
1202.1
The fire-resistance rating of penetrations and fire-resistant joint systems shall be determined in accordance with which sections, respectively?
703.2.1
According to Table 1505.1, what is the minimum roof assembly fire classification required for Type IB construction?
1505.1
For floor areas, the uniformly distributed, concentrated, and impact live load used in the design must be indicated, along with whether live load reduction in accordance with Section 1607.13 is used for:
1603.1.1
Special inspections and tests are not required for Group U occupancies that are accessory to a residential occupancy, unless otherwise required by the:
1704.2 Exception 2
Concrete and masonry chimneys for high-heat appliances must extend not less than 20 feet (6096 mm) higher than any portion of any building within what maximum distance?
2113.11.3.3
As an option for smoke removal in high-rise buildings, mechanical air-handling equipment must provide one exhaust air change every:
403.4.7
Encroachments 15 feet (4572 mm) or more above grade shall not be subject to what restriction?
3202.3.3
For wood products impregnated with chemicals by a pressure process to be qualified as fire-retardant-treated wood, the process must be performed under pressures not less than what minimum gauge pressure?
2303.2.2
For address identification, each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of:
502.1
The design, manufacture, and use of open-web steel joists and joist girders must be in accordance with either SJI 100 or what other standard, as applicable?
2207.1
Where two or more buildings are provided above a horizontal assembly separating them from a Group S-2 parking garage below, how shall the upper buildings be regarded?
510.9
For patterned glass, the nonfactored load (Fge) used in design shall be based on what characteristic of the glass?
2404.3.3
Exterior wall assemblies on buildings of Type I, II, III or IV construction greater than 40 feet in height that contain an exterior wall veneer manufactured using a combustible adhesive to laminate a metal core must be tested in accordance with NFPA 285, with the adhesive level at the:
1402.7
Required critical circuits must be protected by electrical circuit protective systems or construction having a minimum fire-resistance rating of not less than how long?
2702.3
In an atrium containing an interior exit stairway, what is the maximum percentage of the total exit stairways permitted to be located in the same atrium?
404.1
According to Table 2607.4, for a fire separation distance of 11 or more feet but less than or equal to 30 feet, what is the maximum percentage area of the exterior wall permitted for CC1 light-transmitting plastic wall panels?
Table 2607.4
Fasteners for wood shingles shall have a minimum penetration of 3/4 inch into the sheathing. For sheathing less than 1/2 inch in thickness, the fasteners shall:
1507.8.6
Casinos (gaming areas) and nightclubs intended for food and/or drink consumption are classified under which Assembly Group?
303.3
When building construction exceeds 40 feet in height above the lowest level of fire department vehicle access, where must a temporary or permanent stairway be provided?
3310.1
Walls and partitions constructed of adobe units must be supported by foundations or footings that extend not less than what minimum distance above adjacent ground surfaces?
2109.2.4.5.1
What is the exception to the rule prohibiting elevators in a common shaft enclosure with a stairway?
3002.7 Exception
The aggregate clear egress width of the mall in a covered or open mall building shall be not less than:
402.8.1.1
What is the minimum required fire-resistance rating in hours for a fire wall separating Group A, B, E, H-4, I, R-1, R-2, or U occupancies?
Table 706.4
Where cladding is attached directly over foam sheathing to 33 mil cold-formed steel framing using a #10 screw, with a cladding weight of 18 psf and a fastener vertical spacing of 6 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.2.1 (assuming 16 inches on center horizontal spacing)?
1404.5.2.1
Where checkout aisles are provided, how many accessible checkout aisles of each function are required where the total number of checkout aisles of that function is 18?
Table 1110.16.1
The uplift capacity of a single deep foundation element determined by an approved method of analysis must be based on a minimum factor of safety of:
1810.3.3.1.5
Where elevators are not a component of the accessible means of egress, what must the emergency sign adjacent to the call station read?
3002.3
In Seismic Design Categories B, C, D and E, where the bottom of the footing is stepped and the required braced wall panel height varies more than 4 feet, metal ties used to splice the cripple stud wall plate to the sill plate must be what minimum galvanized gage?
2308.10.8.3
In buildings with an occupied floor more than 120 feet (36 576 mm) above the lowest level of fire department vehicle access, fire service access elevators shall have a capacity of not less than:
403.6.1
Light-transmitting plastic wall panels are prohibited from being used in exterior walls in which occupancy groups?
2607.1
A Story Above Grade Plane must have the finished surface of the floor next above more than 6 feet (1829 mm) above grade plane or more than 12 feet (3658 mm) above the:
202 [BG] Story Above Grade Plane
At least one accessible route within the site shall be provided from site arrival points (like public transportation stops) to the accessible building entrance, EXCEPT in buildings not containing or serving:
1104.1 Exception
Where masonry chimneys are constructed as part of masonry or concrete walls, combustible materials shall not be in contact with the masonry or concrete wall less than what minimum distance from the inside surface of the nearest flue lining?
2113.19 Exception 2
Where Section 1705.13 or 1705.14 specifies special inspections or tests for seismic resistance, the statement of special inspections must identify the designated seismic systems and:
1704.3.2
Pipes, wires, conduits, ducts, or other service facilities shall NOT be embedded in the required fire protective covering of a structural member that is required to be:
704.7
Tempered spandrel glass shall be provided with what type of identification by the manufacturer?
2403.1
In aircraft manufacturing facilities of Type I or II construction, for a height of 50 feet (15 240 mm) or more and a manufacturing area of 200,000 square feet (18 580 m2) or more, what is the maximum exit access travel distance permitted?
Table 412.6
For projecting windows, balconies, architectural features or mechanical equipment located more than 8 feet (2438 mm) above grade, how is encroachment calculated?
3202.3.2
The load resistance of vertical glass under uniform load shall be determined in accordance with which ASTM standard?
2404.1
What is the required separation in hours between a sprinklered (S) Group F-2, S-2, or U occupancy and a sprinklered (S) Group H-2 occupancy?
Table 508.4
To allow an occupancy on an occupiable roof that is different from the story immediately below it, the building must be equipped throughout with an automatic sprinkler system and what notification system?
503.1.4 Exception
For wood shear walls and diaphragms designed to resist lateral loads of permanent load duration only, the allowable stress design unit shear capacities must be taken as the AWC SDPWS nominal unit shear capacities multiplied by what factor?
2305.1.2
Wood shakes shall only be used on slopes of not less than what minimum units vertical in 12 units horizontal?
1507.9.2
Foam plastic used as interior trim must comply with Sections 2604.2.1 through 2604.2.4. What is the minimum density required for the interior trim?
2604.2.1
The face of an exit sign illuminated from an external source shall have an intensity of not less than:
1013.6.2
For smoke-protected assembly seating with 25,000 or more seats, what is the required capacity in inches per seat served for stepped aisles without handrails within 30 inches?
Table 1030.6.2
In high-rise buildings of Group A, B, E, I-1, M, or R-1 occupancies, a solid and continuous luminous stripe shall be applied to the horizontal leading edge of each step and shall extend for the full length of the step, with a minimum horizontal width of:
1025.2.1
Where exterior wall openings are required to be protected by Section 705.9, a light-transmitting plastic roof panel shall not be installed within what maximum distance of such exterior wall?
2609.3
According to Table 1404.2, what is the minimum nominal thickness required for steel (approved corrosion resistant)?
1404.2
What is the maximum slope permitted for ramped aisles that are not required to be an accessible route?
1030.14.1
Areas of refuge are generally required at stairways except when the building is equipped throughout with an automatic sprinkler system and/or which other occupancy group?
1009.3.3 Exceptions
Connections in intermediate precast structural walls that are designed to yield must be capable of maintaining 80 percent of their design strength at the deformation induced by the design displacement or must use:
1905.3.1
In moist (A) or marine (C) climate zones, if a drainage space or drainage material is required in addition to the layers required in Section 2510.6.1, what is the minimum required depth of that space or material?
2510.6.2
In structures assigned to Seismic Design Category D or E, portions of floors or roofs that do not support braced wall panels above are permitted to extend up to what maximum distance beyond a braced wall line?
2308.10.8.2
In Group E occupancies, enhanced classroom acoustics shall be provided in all classrooms with a volume of what maximum size?
1207.2
For buildings below slopes steeper than one unit vertical in one unit horizontal (100-percent slope), the toe of the slope shall be assumed to be at the intersection of a horizontal plane drawn from the top of the foundation and a plane drawn tangent to the slope at an angle of:
1808.7.1
The finished ground level of an under-floor space such as a crawl space shall not be located below the:
1805.1.2
Which of the following is listed as a special consideration that must be indicated on the construction documents for steel joists?
2207.2 Item 2.2
When using the alternative allowable stress design load combinations that include the counteracting effects of dead and wind loads, only what fraction of the minimum dead load likely to be in place during a design wind event shall be used?
1605.2
The building official is authorized to serve a notice of violation on the person responsible for work in conflict with the code or in violation of a permit or certificate issued, and such order shall direct the discontinuance of the illegal action and the:
114.2
Where equipment replacements and repairs must be performed in an emergency situation, when must the permit application be submitted to the building official?
105.2.1
The exemption for accessible routes in multilevel buildings with less than 3,000 square feet aggregate area does NOT apply to structures with how many or more dwelling units?
1104.4 Exception 1.5
If buildings contain materials representing hazards classified in one or more of Groups H-1, H-2, H-3, and H-4, the buildings and structures must conform to the code requirements for:
307.8
Common use circulation paths within employee work areas shall be accessible routes, EXCEPT where the paths are located within work areas that are less than how many square feet (m2) in size and defined by permanently installed partitions, counters, casework or furnishings?
1104.3.1 Exception 1
According to Table 1807.1.6.3(1) for plain masonry foundation walls, what is the minimum nominal wall thickness required for an 8-foot maximum wall height, 6-foot maximum unbalanced backfill height, and a design lateral soil load of 45 psf/ft?
1807.1.6.3
If an occupiable roof is provided, how shall it be classified?
302.1
Soffits and fascias at roof overhangs must be capable of resisting the component and cladding loads for walls determined in accordance with Chapter 16 using an effective wind area of:
1412.2
Special purpose horizontal sliding, accordion, or folding door assemblies permitted in the means of egress shall open to the minimum required width within what maximum time after activation of the operating device?
1010.3.3 Item 8
Factory industrial uses involving the fabrication of noncombustible materials, such as brick and masonry or glass products, that do not involve a significant fire hazard are classified as which group?
306.3
For anchored stone veneer with wood stud backing, what is the minimum thickness of cement grout that must be placed between the backing and the stone veneer?
1404.8
Doors opening onto a ramp landing shall not reduce the clear width to less than:
1012.5.3
According to Table 903.2.5.2, what is the required Occupancy Hazard Classification for Storage rooms with dispensing in a Group H-5 occupancy?
Table 903.2.5.2
An enclosed parking garage accessory to a one- or two-family dwelling is exempt from which requirement?
406.6.2 Exception
Premixed prepared Portland cement mortars used in ceramic tile installation, requiring only the addition of water, must comply with which ANSI standard?
2103.2.3.1
In Whittier, Alaska, at an elevation of 100 feet, what is the ground snow load in pounds per square foot required for a Risk Category I building, according to Table 1608.2?
1608.2
In conventional light-frame construction, for Seismic Design Categories D and E, what is the maximum spacing permitted for braced wall lines?
2308.10.1
Required design wind pressures determined from ASCE 7 for exterior windows and doors shall be permitted to be converted to allowable stress design by multiplying by which factor?
1709.5
What is the maximum allowable quantity (in cubic feet at NTP) for the use of Highly Toxic gas in open systems per control area?
Table 307.1(2)
In Type IV-A construction, the outside face of exterior walls of mass timber construction must be protected with noncombustible protection contributing a minimum assigned time of:
602.4.1.1
For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required thickness of plain concrete footings is permitted to be 6 inches, provided the footing does not extend more than what maximum distance on either side of the supported wall?
1906.1
Basements need not be included in the total allowable floor area of a building, provided the total area of such basements does not exceed the area permitted for a building with a maximum of:
506.1.3
Continuous special inspections must be performed during the installation of helical pile foundations, and the information recorded must include installation equipment used, pile dimensions, tip elevations, final depth, and:
1705.9
What is the Tabular allowable area factor in square feet for a building classified as Group E, one story above grade plane (S1) of Type VA construction?
Table 506.2
Where a drain tile or perforated pipe is used for a foundation drain, the pipe or tile shall be placed on not less than what minimum thickness of gravel or crushed stone?
1805.4.2
Vestibules and storm enclosures shall not encroach more than 3 feet (914 mm) nor more than what fraction of the width of the sidewalk beyond the street lot line?
3202.4
An adobe unit shall not contain more than three shrinkage cracks, and any single shrinkage crack shall not exceed 3 inches (76 mm) in length or what maximum width?
2109.2.1.4
Broken glass retention screens must be installed within what maximum distance of the glass?
2405.3
Design rainfall intensity (in/hr), and the locations of which roof drainage component must be shown on construction documents, regardless of whether rain loads govern the design?
1603.1.9
Each pane of glass must bear the manufacturer’s mark designating the type and thickness, unless an affidavit is furnished by the glazing contractor certifying that each light is glazed in accordance with:
2403.1
Structural through-fastened metal panel roof systems shall be tested in accordance with ASTM E1592, UL 580 or:
1504.4.2
Masonry design must comply with the provisions of TMS 402, TMS 403, or:
2101.2
What is the maximum allowable number of stories above grade plane for a sprinklered (S) Group F-1 occupancy of Type IVA construction?
Table 504.4
A permit is required for temporary structures that cover an area greater than 120 square feet (11.16 m2) and are intended for the gathering together of how many or more persons?
3103.1.3
When designing wood elements using allowable stress design, the allowable unit stresses for preservative-treated wood are not required to be adjusted for treatment, but load duration factors greater than what maximum value shall not be used in the structural design?
2306.1.3
The area of a single section of thin exterior structural glass veneer shall not exceed 10 square feet where that section is not more than 15 feet above the level of the sidewalk, and shall not exceed what maximum area where it is more than 15 feet above that level?
1404.13
According to Table 2609.4, what is the maximum area of an individual roof panel (in square feet) permitted for Class CC2 plastic?
Table 2609.4
A Flammable Gas Category 1B must have a lower flammability limit of more than 6 percent by volume of air, or a fundamental burning velocity of less than:
202 [F] Category 1B
Joints and voids that create concealed spaces between connected or stacked intermodal shipping containers at fire-resistance-rated assemblies must be protected by what approved system?
3114.7
Unlimited area two-story buildings (Group B, F, M or S) must be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and surrounded by public ways or yards not less than:
507.5
Roof replacement requires the removal of all existing layers of roof assembly materials down to the roof deck, EXCEPT where the existing roof includes two layers of self-adhered underlayment, the second layer may only be installed if the buildup of material at walls, valleys, roof edges, end laps and side laps does not exceed:
1512.2 Exception 3.3
Occupiable spaces, habitable spaces and corridors shall have a minimum ceiling height of:
1208.2
An application for a permit is deemed abandoned how many days after the date of filing, unless pursued in good faith or a permit has been issued?
105.3.2
According to Table 1507.9.8, what is the maximum weather exposure (in inches) permitted for 24-inch, Grade No. 1 taper sawn shakes of naturally durable wood installed on a 4:12 pitch or steeper?
1507.9.8
What types of systems are prohibited from being located in an elevator hoistway enclosure?
3002.9
Where elevator lobby exit access doors are electrically locked (Section 1010.2.14), activation of the building fire alarm system by means other than a manual fire alarm box shall automatically unlock the electric locks, and the electric locks shall remain unlocked until:
1010.2.14 Item 3
In areas likely to have expansive soil, the building official must require soil tests where such soils exist, and soils must be considered expansive if the expansion index determined in accordance with ASTM D4829 is greater than:
1803.5.3
The maximum rise permitted for alternating tread devices used as a means of egress between floor levels or landings is:
1011.14
What type of standpipes (temporary or permanent, with or without water supply) are permitted during construction, provided they conform to Section 905 regarding capacity, outlets, and materials?
3311.3 Exception
For allowable stress design of masonry, the design must comply with Section 2106 and the requirements of Chapters 1 through 8 of TMS 402, except as modified by Sections 2107.2 through:
2107.1
The provisions governing the design and construction of buildings for energy efficiency are found in the:
101.4.6
For an open parking garage beneath Groups A, I, B, M and R, the height, in both feet and stories, of the portion of the building above the open parking garage shall be measured from grade plane and shall include:
510.7
In determining the fire-resistance rating of a shaft enclosure, the number of stories connected shall include any basements but not any:
713.4
For flammable gases in Group H-5 occupancies, the gas detection monitoring threshold level shall be vapor concentrations in excess of what percentage of the lower flammable limit (LFL)?
415.11.8.2
What is the required interior wall and ceiling finish classification for rooms and enclosed spaces in a nonsprinklered Group I-1 occupancy?
Table 803.13
For strength design of masonry, the design must comply with Section 2106 and the requirements of Chapters 1 through 7 and Chapter 9 of TMS 402, except that AAC masonry must comply with Chapters 1 through 7 and Chapter:
2108.1 Exception
For polypropylene siding fasteners, where the nail fully penetrates the sheathing or nailable substrate, the end of the fastener shall extend not less than what minimum distance beyond the opposite face?
1404.18.2
Light-transmitting plastic used for skylight glazing must be mounted on a curb not less than what minimum height above the plane of the roof?
2610.2
Gypsum wallboard or gypsum plaster shall not be used in any exterior surface where such gypsum construction will be exposed directly to the weather, nor shall gypsum wallboard be used where there will be direct exposure to water or continuous:
2508.2
What is the minimum height required for a parapet above the point where the roof surface and the wall intersect?
705.12.1
The minimum interval required between the second coat and the finish coat of exterior cement plaster is:
Table 2512.6
In covered and open mall buildings, what is the maximum path of travel distance to required public and employee toilet facilities?
2902.3.4
Where pass-through openings are provided in smoke partitions in Group I-2, Condition 2 occupancies, the aggregate area of all such openings within a single room shall not exceed:
710.5.3
For exterior walls of buildings of any height, foam plastic insulation tested separately must have a flame spread index of 25 or less and a smoke-developed index of 450 or less, in a thickness not to exceed:
2603.5.4
Where shallow foundations will bear on controlled low-strength material (CLSM), the geotechnical investigation must include specifications for the preparation of the site prior to placement of the CLSM and test methods to determine the compressive strength or:
1803.5.9
Deferred submittal items shall not be installed until the corresponding documents have been:
107.3.4.1
In structures without elevator service, where stories have entrances proximate to arrival points, and the slope of the undisturbed site measured between the entrance and all vehicular or pedestrian arrival points within 50 feet (15 240 mm) is what maximum percentage, all units on that story shall be Type B units?
1108.7.1.2 Item 1
In boxes other than luxury boxes, club boxes and suites, wheelchair spaces shall be located in not less than what percentage of all boxes provided?
1109.2.2.3
Class C interior finish materials are permitted in places of assembly with an occupant load of:
Table 803.13 Note f
Foundation walls and other walls in which horizontal movement is restricted at the top shall be designed for what type of lateral soil pressure?
1610.1
Greenhouses used for the display and sale of plants that provide public access are classified as which occupancy group?
309.1
For combustible core IMP installations greater than 40 feet in height above grade plane on Types I, II, III and IV construction, the system must be tested in accordance with and comply with the acceptance criteria of:
1409.7.3.3
What is the Tabular allowable area factor in square feet for a building classified as Group I-2, one story above grade plane (S1) of Type VB construction?
Table 506.2
In continuous loading zones, one passenger loading zone in every continuous how many linear feet (m) maximum of loading zone space shall be accessible?
1106.9.1
What two essential fire alarm system components must be monitored by the building’s fire alarm system for an automatic sprinkler system serving occupant evacuation elevators?
3008.2.2
Emergency power systems and standby power systems must be designed to provide the required power for a minimum duration of how long without being refueled or recharged, unless specified otherwise in this code?
2702.1.5
What two types of notification appliances must be installed within each occupant evacuation elevator lobby?
3008.9.1
Installation of a skylight without a curb is permitted on roofs with a minimum slope of 14 degrees (three units vertical in 12 units horizontal) in which specific occupancy group?
2405.4
Vehicle barriers in a public parking garage shall be not less than what height?
406.4.2
Steel fireplace units incorporating a steel firebox lining must be constructed with steel not less than what minimum thickness?
2111.6.1
Round chimney flues serving fireplaces must have a minimum net cross-sectional area of not less than what minimum fraction of the fireplace opening?
2113.16.1
Pedestrian walkways shall be designed and constructed in accordance with which sections?
3104.1.1
Emergency and standby power systems must be maintained and tested in accordance with which code?
2702.4
According to Table 716.1(1), the marking “OH” on fire-rated glazing indicates that the assembly meets which criteria?
Table 716.1(1)
For structures assigned to Seismic Design Category D, E or F, deep foundation elements on Site Class E or F sites must be designed and constructed to withstand maximum imposed curvatures from:
1810.2.4.1
At least what percentage, but not less than one, of the total number of aisle seats provided shall be designated aisle seats located closest to accessible routes?
1109.2.5
The capacity, in inches, of means of egress components other than stairways shall be calculated by multiplying the occupant load served by a capacity factor of 0.2 inch (5.1 mm) per occupant, EXCEPT that in sprinklered buildings (other than Group H and I-2), the factor is reduced to:
1005.3.2 Exception 1
Where an airport traffic control tower is provided with only one exit stairway, interior wall and ceiling finishes shall be Class A or:
412.2.2.3.1
Where a maximum one story above grade plane Group S-2 parking garage of Type I construction is provided under a building of Group R, the floor assembly between the parking garage and the Group R above shall provide a fire-resistance rating not less than the mixed occupancy separation required in which section?
510.4
The design, fabrication, and erection of austenitic and duplex structural stainless steel must be in accordance with which standard?
2203.1
Buildings containing Group I-2 occupancies (Hospitals, etc.) are assigned to which risk category?
1604.5
Where requested by the registered design professional, the steel joist manufacturer must submit design calculations with a cover letter bearing the seal and signature of the joist manufacturer’s:
2207.3
A building or structure in which vertical loads from floors and roofs are primarily supported by walls is defined as a:
202 [BS] Bearing Wall Structure
The L Rating for a fire-resistant joint system is tested in accordance with UL 2079, while the L Rating for a through-penetration firestop system is tested in accordance with:
202 [K] L Rating
Where changes in elevation of less than 12 inches (305 mm) exist in the means of egress, sloped surfaces must be used, and ramps complying with Section 1012 must be used where the slope is greater than:
1003.5
Exterior decks, patios or balconies that are part of Type B units are exempt from accessible requirements if they have impervious surfaces and are not more than what maximum distance below the finished floor level of the adjacent interior space of the unit?
1108.3 Exception 3
What must be provided before a horizontal exit can be destroyed?
3303.3
A free-standing building assigned to Risk Category I is excepted from frost protection requirements if the area is 600 square feet or less for light-frame construction OR what maximum area for other than light-frame construction?
1809.5 Exception
According to Table 1507.10.2, which ASTM standard applies to Coal-tar pitch used in roofing?
1507.10.2
Horizontal exits are permitted to comprise two-thirds of the required exits from any building or floor area for which specific occupancy group?
1026.1 Exception 1
In all occupancies, interior floor covering materials must comply with the requirements of the DOC FF-1 “pill test” (CPSC 16 CFR Part 1630) or with:
804.4.1
Where venting only one appliance, two flues are permitted to adjoin each other in the same chimney with only the flue lining separation between them, provided the joints of the adjacent flue linings are staggered not less than:
2113.14 Exception
Glazed areas in hazardous locations must comply with impact requirements, with the exception of mirrors and other glass panels mounted or hung on a surface that provides a:
2406.1
A single fixture is the minimum required for the number of persons indicated or what maximum fraction of the number of persons indicated in Table 2902.1?
2902.1 Note
Light-transmitting plastic diffusers used in a light-diffusing system that is not protected by an automatic sprinkler system shall not be installed in which occupancy groups?
2606.7
The design, fabrication, and erection, including related connections and protective coatings, of steel cables for buildings must be in accordance with which standard?
2214.1
The analysis of deep foundation elements must include group effects on axial behavior where the center-to-center spacing of elements is less than what maximum factor multiplied by the least horizontal dimension of an element?
1810.2.5
To be considered firmly supported, if the glass edge length is greater than 13 feet 6 inches (4115 mm), the deflection of the glass edge perpendicular to the pane shall not exceed 1/240 of the glass edge length plus:
2403.3
Structural standing-seam metal panel roof systems that function as both the roof deck and roof covering shall be tested in accordance with FM 4474 or:
1504.4.2
What minimum horizontal distance must intermodal shipping containers housing or supporting experimental equipment be located from adjacent structures?
3114.1 Exception 4.2
Fire-protection-rated glazing used as vision panels in self-closing swinging fire door assemblies serving as horizontal exits in fire walls shall be limited to what maximum area?
716.2.5.1.2.1
The minimum size for stairway identification signs required at floor landings in interior exit stairways and ramps connecting more than three stories shall be:
1023.9.1
Which occupancy group classification shall live/work units be classified as?
508.5.2
Masonry heaters must comply with the requirements of ASTM E1602 or be listed and labeled in accordance with UL 1482 or:
2112.2
A Low Explosive material is characterized by a rate of reaction that is less than the speed of:
202 [F] Low Explosive
For a pair of fire doors in a storage or equipment room where the inactive leaf is not needed to meet egress capacity, which type of latching device is Permitted on the inactive leaf?
Table 1010.2.4
Where two or more exits are required, not more than what fraction of the total number of exits or total exit minimum width/required capacity shall be horizontal exits?
1026.1
For care recipients confined to bed or a stretcher, the refuge area provided within a smoke compartment shall be not less than:
407.5.3
The installation of replacement glass shall be as required for:
2402.1
Where provided, lightning protection systems must comply with Sections 2703.2 through which other section?
2703.1
What feature of conventional elevators is prohibited from being installed on elevator systems used for fire service access elevators?
3007.4
Unstabilized adobe units must have an average modulus of rupture of what minimum value?
2109.2.1.2
For braced wall panels in conventional light-frame construction assigned to Seismic Design Category D or E, what is the maximum distance a braced wall panel is allowed from each end of the braced wall line?
2308.10.1
For masonry foundation walls designed using the prescriptive method, masonry units shall be laid in running bond and installed with which mortar type or greater in accordance with Section 2103.2.1?
1807.1.6.3 Item 7
What is the maximum exit access travel distance in feet for a sprinklered Group F-2, S-2, or U occupancy?
Table 1017.2
The aggregate area of all equipment platforms within a room shall be not greater than what fraction of the area of the room in which they are located?
505.3.1
Not more than what maximum percentage of the thickness measurements of the SFRM shall be less than the thickness required by the approved fire-resistance design?
1705.15.4
The ground immediately adjacent to the foundation must be sloped away from the building at a slope of not less than 1 unit vertical in 20 units horizontal (5-percent slope) for a minimum distance of:
1804.4
Where more than one exit or exit access doorway is required, dead-end corridors shall not exceed what maximum length?
1020.5
For the purposes of this code, words stated in the masculine gender include the feminine and:
201.2
According to Table 1404.3(5), for walls without a Class I, II, or III interior vapor retarder in Climate Zone 4, what is the minimum required R-value for continuous insulation on the exterior?
1404.3
Where an egress court serving a building is less than 10 feet (3048 mm) in width, the egress court walls shall have not less than 1-hour fire-resistance-rated construction for a distance of how many feet above the floor of the egress court?
1029.3
In Group A-1, A-2, A-3, or A-4 occupancies, if the building occupant load is greater than what threshold, accessible public entrances must have a power-operated door or a low-energy power-operated door?
Table 1105.1.1
According to Table 1405.1.1.1.2, if a combustible exterior wall covering has a tolerable level of incident radiant heat energy of 5.2 kW/m2 without exhibiting sustained flaming, what is the minimum required fire separation distance (in feet)?
1405.1.1.1.2
Where checkout aisles are provided, how many accessible checkout aisles of each function are required where the total number of checkout aisles of that function is 7?
Table 1110.16.1
In Types IV-A, IV-B, and IV-C construction, sealant or adhesive must be provided at abutting edges and intersections of mass timber building elements where those elements are required to be:
703.7
Approved agencies for smoke control testing must have expertise in fire protection engineering, mechanical engineering and certification as:
1705.19.2
Where stepped aisles have seating on one side and the aisle width is 74 inches (1880 mm) or greater, how many handrails are required?
1030.16
If walls and partitions separating sleeping units are field tested for airborne noise in accordance with ASTM E336, they must have a Normalized Noise Isolation Class (NNIC) rating of not less than:
1206.2
What is the minimum required fire-resistance rating in hours for the roof construction in a Type IVC building?
Table 601
Modified bitumen roofing shall have a design slope of not less than what minimum units vertical in 12 units horizontal for drainage?
1507.11.1
An Institutional Group I-2 facility (Condition 1) provides nursing and medical care but does not provide which of the following services?
308.3.1.1
A 4-inch cube cut from a stabilized adobe unit shall not absorb more than what maximum percentage of moisture by weight when placed on a constantly water-saturated, porous surface for seven days?
2109.2.2.2
Where one or more sides of any pane of glass are not firmly supported, or are subjected to unusual load conditions, detailed construction documents, detailed shop drawings and analysis or test data must be prepared by a:
2403.2
At least how many wheelchair spaces shall be provided in team or player seating areas serving areas of sport activity?
1111.4.2
Class A, B and C roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with UL 790 or:
1505.1
Footings for masonry fireplaces and their chimneys must be constructed of concrete or solid masonry not less than how thick?
2111.3
The fire separation distance between a building with polypropylene siding and the adjacent building must be not less than:
1403.11.2
In occupancies other than Groups H and I, which are no more than two stories above grade plane and are equipped throughout with an automatic sprinkler system, a mezzanine having two or more exits or access to exits is:
505.2.3 Exception 5
Fire partitions serving as a corridor wall are permitted to terminate above the lower membrane of a corridor ceiling, provided the corridor ceiling membrane is equivalent to the corridor wall membrane and the building is equipped throughout with an automatic sprinkler system and sprinklers are installed in the space:
708.4 Exception 2
Where an exterior wall intersects a fire wall, the fire-resistance rating of the exterior wall shall extend not less than what distance on each side of the intersection?
706.5.1
According to Table 1705.6, what type of inspection is required during fill placement to verify densities and lift thicknesses during placement and compaction of compacted fill?
Table 1705.6 Item 4
What is the minimum nominal dimension for wood furring strips installed over solid backing?
2504.1.1 Exception
Signage indicating “AREA OF REFUGE” or “EXTERIOR AREA FOR ASSISTED RESCUE” shall comply with ICC A117.1 requirements for visual characters and shall include what specific symbol?
1009.9
Supporting data necessary to assist in the approval of products, materials or assemblies not specifically provided for in this code must consist of valid research reports from:
1703.4.2
The ultimate axial load capacity of a test element, as determined by a registered design professional, must be used to set the resulting allowable load, which shall not be more than what maximum fraction of the ultimate capacity?
1810.3.3.1.2
Structures, sites, and equipment directly associated with the actual processes of construction are not required to comply with Chapter 11, including, but not limited to, scaffolding, bridging, and:
1103.2.5
For cold-formed steel light-frame construction in high wind areas, periodic special inspection is required for welding operations of elements of the:
1705.12.2
Where ultraviolet (UV) germicidal irradiation systems are provided, they shall be listed and labeled in accordance with which standard?
1211.1
The fire command center must be provided with the means to manually initiate which phase of emergency recall for the occupant evacuation elevators?
3008.7.1
Bulkheads used for the shelter of mechanical or electrical equipment or vertical shaft openings in the roof assembly shall comply with Section 1511.2 as:
1511.7.2
Wood members supporting concrete, masonry, or similar materials must be checked for the effects of long-term loading using the provisions of which standard?
2304.13
What is the minimum required fire-resistance rating in hours for the floor construction in a Type IIB building?
Table 601
Where the footboards or walking surface of seating facilities are more than 30 inches (762 mm) above the floor or grade below, perimeter guards are required. Where seatboards are adjacent to the perimeter, the minimum guard height shall be:
1030.17.1
Where interior finish materials are applied to furring strips in noncombustible or fire-resistance-rated construction, the intervening spaces between the furring strips shall be fireblocked at not greater than what distance in every direction?
803.15.1.1
For a nonsprinklered space in Group B occupancy with an occupant load greater than 30, what is the maximum common path of egress travel distance permitted in feet?
Table 1006.2.1
Where required exterior openings for ventilation open into a sunroom with thermal isolation, the openable area between the sunroom addition and the interior room shall have an area of not less than 8 percent of the interior room floor area, but not less than how many square feet?
1202.5.1.1 Exception
What is the minimum required dimension for an enclosed fire service access elevator lobby?
3007.6.4
Unit skylights and tubular daylighting devices must be tested and labeled as complying with which standard?
2405.5
Where a combustible exterior wall covering is furred out from the exterior wall and forms a solid surface, the distance between the back of the exterior wall covering and the exterior wall shall not exceed what maximum distance, unless excepted by Section 718?
1405.1.3
For areas having fixed seating without dividing arms, the occupant load shall be based on one person for each what minimum length of seating?
1004.6
Plastic composite deck boards and stair treads must bear a label indicating compliance with ASTM D7032 and include the allowable load and:
2612.2
What existing dwelling type is specifically exempted from the provisions of Section 3113 governing relocatable buildings?
3113.1 Exception
A claim filed with the board of appeals must be based on a claim that the true intent of this code has been incorrectly interpreted, the provisions of this code do not fully apply, or that:
113.2
Where court-floor holding cells are provided and are not separated by age or sex, courtrooms shall be served by at least how many accessible cells?
1109.4.2.2
For the purposes of this classification, where an accurate boiling point is unavailable for a liquid or mixture, what is used as the boiling point?
202 [F] Boiling Point
For exterior nonbearing walls and partitions, the required fire-resistance rating is based on:
Table 601, Table 705.5
The minimum thickness of hearth extensions shall be:
2111.10.2
For exposed aggregate plaster applied over concrete or masonry surfaces, what is the minimum overall thickness required?
2513.4
In Group I-3, Condition 2, 3, or 4 occupancies, the dead end in a corridor shall not exceed what maximum length?
1020.5 Exception 1
What is the minimum nominal thickness in the least dimension required for wood supports, wood stripping, or furring for lath or gypsum panel products?
2504.1.1
The registered design professional in responsible charge is responsible for reviewing and coordinating submittal documents prepared by others, including:
107.3.4
Periodic special inspection shall be provided for the installation of cold-formed steel special bolted moment frames in structures assigned to which Seismic Design Categories?
1705.13.9
What is the maximum permitted thickness for a surfacing material that has a flame spread index not greater than 50 (when tested to ASTM E84 or UL 723) to be considered noncombustible when applied over a structural noncombustible base?
703.3.1 Exception
For anchored stone veneer with concrete or masonry backing, anchor ties must be placed so that the eyes or loops are 12 inches maximum on center in both directions, and a corrosion-resistant wire tie must be threaded through the exposed loops for every:
1404.8
For high-load diaphragms, the special inspector must verify the nominal size of framing members at adjoining panel edges and the spacing between fasteners in each line and at:
1705.5.1
What means must be provided to automatically disconnect the main line power supply to an affected elevator prior to the application of water from automatic sprinklers?
3005.5
Where standby power is required or furnished to operate an elevator, how must the standby power be transferable to all elevators in each bank?
3003.1.1
Where the total number of parking spaces provided is four or less, identification of accessible parking spaces is not required, EXCEPT for parking spaces required by which section?
1112.1 Item 1 Exception
Openings in exterior walls required to be fire-resistance rated surrounding the perimeter of the pedestrian walkway connection must be equipped with opening protectives providing what minimum fire protection rating?
3104.5.1.2
Where access is by means of a private road and the building address cannot be viewed from the public way, what means shall be used to identify the structure?
502.1
Which standard applies to the installation of gypsum panel products?
Table 2508.1
After a structure has been demolished, how must the vacant lot be maintained?
3303.4
According to Table 1705.5.3, what type of inspection is required for adhesive anchors installed in a horizontal or upwardly inclined orientation to resist sustained tension loads in mass timber construction?
Table 1705.5.3 (Adhesive anchors installed in horizontal or upwardly inclined orientation…)
Where textile wall coverings are tested in accordance with the Method B protocol of NFPA 265, flashover is NOT permitted to occur, and the total smoke release shall not exceed:
803.5.1.1
Continuously operated mechanical ventilation for crawl spaces shall be provided at a rate of 1.0 cubic foot per minute (cfm) for each how many square feet of crawl space ground surface area?
1202.4.3.1
The last portion of the exit access leading to the exit on an exterior egress balcony may increase the total exit access travel distance by an additional amount up to:
1017.2.1
Dampproofing materials for floors installed beneath the slab must consist of not less than 6-mil polyethylene with joints lapped not less than:
1805.2.1
Plaster containing Portland cement is prohibited as a finish over what type of plaster?
2109.2.4.8.9.4
The use of clay plasters is prohibited on weather-exposed:
2109.2.4.8.9.3
In Group R-2, R-3, and R-4 occupancies where recreational facilities serve a single building containing Type A units or Type B units, what percentage, but not less than one, of each type of recreational facility shall be accessible?
1111.2.2
The foundation or superstructure shall be designed to resist the effects of the mislocation of any deep foundation element by not less than:
1810.3.1.3
The refractory brick lining for medium-heat appliance chimneys must start not less than what minimum distance below the lowest chimney connector entrance?
2113.11.2.2
The projection of a single corbeled course in a masonry chimney shall not exceed one-half the unit height or what maximum fraction of the unit bed depth, whichever is less?
2113.5
What must protect openings in pedestrian barriers?
3306.5
For foam plastic interior trim, the flame spread index shall not exceed 75, and the smoke-developed index shall not be limited, unless the material is tested in accordance with which alternative standard?
2604.2.4 Exception
Joint and fastener treatment is generally not required where the gypsum panel product is to receive a decorative finish such as wood paneling, battens, acoustical finishes, or any similar application that would be equivalent to:
2508.5 Exception
Where public restrooms are visually screened from outside entry or exit doorways, visual screening is NOT required if the room is:
1210.3 Exception
Wire backing is not required under which two types of lath?
2510.5.3
Buildings whose primary occupancy is public assembly with an occupant load greater than 300 are assigned to which risk category?
1604.5
Emergency power systems provided for exit signs must be capable of powering the required load for a duration of not less than how long?
2702.2.6
An automatic sprinkler system shall be provided throughout all buildings with a Group R fire area and shall be installed in accordance with:
903.2.8
What is the minimum width required for a walkway provided for pedestrian travel in front of every construction and demolition site?
3306.2
A drain placed around the perimeter of a foundation shall extend not less than what minimum distance beyond the outside edge of the footing?
1805.4.2
What is the minimum thickness required for gypsum board used as a thermal barrier for mass timber elements serving as occupancy fire barriers in Type IV-B or IV-C construction?
508.4.4.1
What is the maximum occupant load permitted for accessory religious educational rooms or religious auditoriums to avoid being considered separate occupancies?
303.1.4
Light-transmitting plastic diffusers must be supported by noncombustible hangers that are not less than what minimum gauge size?
2606.7.1
Stumps and roots must be removed from the soil to a depth of not less than what minimum distance below the surface of the ground in the area to be occupied by the building?
3304.1
Clay and concrete tile shall be installed only over solid sheathing, EXCEPT that spaced lumber sheathing shall be permitted in which Seismic Design Categories?
1507.3.1 Exception
Chimneys located entirely outside the exterior walls of the building, including chimneys that pass through the soffit or cornice, shall have a minimum airspace clearance of:
2113.19
Where only one accessible route is provided, it shall not pass through:
1104.5 Item 3
A marquee must be supported entirely from which structure?
3106.5
Accessible vehicle spaces at electrical vehicle charging stations shall comply with the requirements for a van accessible parking space that is 132 inches (3350 mm) minimum in width with an adjoining access aisle that is what minimum width?
1107.2.2
High-load diaphragms utilizing multiple rows of staples (Table 2306.2(2)) require the minimum nominal depth of framing members to be what minimum thickness?
2306.2(2)
Except in Seismic Design Categories D, E and F, pier and curtain wall foundations are permitted to be used to support light-frame construction not more than how many stories above grade plane?
1809.1
Is wiring and cables to control signals required to be protected if they do not serve Phase II emergency in-car operations for a fire service access elevator?
3007.8.1 Exception
Basements not more than one story below grade plane are permitted in unlimited area buildings of the occupancies and configurations specified in which section?
507.1
Fiber-reinforced polymer (FRP) used on exterior walls must comply with Section 2603.5, unless the FRP does not exceed an aggregate total of 20 percent of the area of the specific wall, and single architectural elements do not exceed what maximum percentage of the specific wall area?
2613.5 Exception 1.1
What is the ground snow load reduction factor for a public-occupancy temporary structure in Risk Category III with a service life of 10 years?
Table 3103.6.1.1
According to Table 1404.3(1), which class of vapor retarder has a perm rating of less than or equal to 0.1?
1404.3
A permit is required for an owner or owner’s authorized agent who intends to perform which of the following activities regarding a building or structure?
105.1
Where deep foundation elements stand unbraced in air, water or fluid soils, they shall be permitted to be considered laterally supported at a point 5 feet into stiff soil or what minimum distance into soft soil, unless otherwise approved?
1810.2.1
For bearing wall structures, longitudinal ties shall be spaced at not greater than what maximum distance on center?
1616.3.2.1
Wall pockets or crevices in which moisture can accumulate must be protected with caps or drips, or other approved means, as required in:
1404.4.2
Chimneys for medium-heat appliances must be constructed of solid masonry units or concrete with walls not less than 8 inches (203 mm) thick, or with stone masonry not less than how thick?
2113.11.2.1
Glass unit masonry construction must comply with Chapter 14 of TMS 402 and:
2110.1
Standby power provided for in-building 2-way emergency responder communication coverage systems must be capable of operating the system at 100-percent system operation capacity for a duration of not less than how long?
2702.2.3
For polypropylene siding, the certification of the flame spread index must be accompanied by a test report stating that all portions of the test specimen ahead of the flame front remained in position during the test in accordance with:
1403.11.1
Polypropylene siding is limited to exterior walls located in areas where the basic wind speed does not exceed 100 miles per hour and the building height is less than or equal to 40 feet in which exposure classification?
1404.18
What is the minimum required separation in hours between a nonsprinklered (NS) Group R occupancy and a nonsprinklered (NS) Group I-4 occupancy?
Table 508.4
A fire watch shall be provided during nonworking hours for construction that exceeds what minimum height above the lowest adjacent grade at any point along the building perimeter?
3314.1
Assembly occupancies with an occupant load of 500 or more located within a covered mall building shall have not less than what proportion of their required means of egress opening directly to the exterior?
402.8.4
The unsupported height of any wall constructed of adobe units shall not exceed what maximum multiple of the wall thickness?
2109.2.4.4
Anchor rods must be set in accordance with the approved construction documents, and the protrusion of the threaded ends through the connected material shall fully engage the threads of the nuts, but shall not be greater than which length?
2201.5
According to Table 1705.2.6, what type of special inspection is required for the installation of X-bracing, tightened to remove any sag?
Table 1705.2.6 Item 4
For awnings and canopies, if the covering material is tested in accordance with NFPA 286, what is the maximum permissible peak heat release rate throughout the test?
3105.3
What fastening condition is permitted to be omitted at the top and bottom plates of vertical assemblies, or edges and ends of horizontal assemblies perpendicular to supports, and at the wall line?
2508.3.1
To be excepted from NFPA 285 testing, a combustible water-resistive barrier (WRB) that is the only combustible component must have a flame spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84 or UL 723, with test specimen preparation and mounting in accordance with:
1402.6 Exception 2.2
Buildings containing corrosives, highly toxic materials, or toxic materials that are health hazards shall be classified as which High-Hazard Group?
307.6
What is the maximum height permitted for Type IIA construction for an airport traffic control tower?
Table 412.2.1.1
Installation of exterior and interior cement plaster and lathing must be in compliance with ASTM C926 and which other standard?
2510.3
For Group H-5 Higher education laboratories, what is the maximum percentage of the maximum allowable quantity permitted per lab suite located on floors 11 through 15 above grade plane?
Table 428.3
In a self-service storage facility with 300 total spaces, what is the minimum number of required accessible self-storage spaces?
Table 1109.3
In Group I-3 occupancies, at least what percentage of the total number of sleeping units in the facility, but not less than one unit in each classification level, shall be Accessible units?
1108.5.5.1
Rooftop-mounted PV panel systems shall be assigned to the same risk category as:
1604.5.2
Projections extending to 5 feet (1524 mm) or less from the line used to determine the fire separation distance shall be constructed of combustible materials of not less than:
705.2.3
Where an HVAC system is fully ducted in Group I-2, a lay-in ceiling system is considered capable of limiting the transfer of smoke if the ceiling tiles weigh not less than:
710.4 Exception
Crawl spaces shall be provided with not less than one access opening that shall be not less than:
1209.1
What is the maximum percentage of maximum allowable quantities of hazardous materials permitted per control area on the third story above grade plane?
Table 414.2.2
What minimum period prior to the scheduled starting date of the excavation must the person making the excavation provide written notice to owners of adjacent property?
3307.1
For cold-formed steel trusses with clear spans 60 feet (18 288 mm) or greater, who must contract with a registered design professional for the design of the temporary installation restraint/bracing and the permanent individual truss member restraint/bracing?
2206.1.3.2
Fire dampers installed in an assembly having a required fire-resistance rating of 3 hours or greater shall have a minimum damper rating of:
Table 717.3.2.1
Float, wired, and patterned glass in louvered windows and jalousies shall be not thinner than nominal 3/16 inch (4.8 mm) and not longer than:
2403.5
What is the required separation in hours between a nonsprinklered (NS) Group F-1 occupancy and a nonsprinklered (NS) Group R occupancy?
Table 508.4
What is the required separation in hours between a sprinklered (S) Group I-2 occupancy and a sprinklered (S) Group A or E occupancy?
Table 508.4
Which concrete element is exempt from special inspections and tests if the effective prestress in the concrete is less than 150 psi (1.03 MPa)?
1705.3 Exception 3
Construction of dry-stack masonry must comply with which ASTM standard?
2114.5
An Accreditation Body is an approved, third-party organization that monitors the competency and performance of a grading or inspection agency and is independent of:
202 [BS] Accreditation Body
Special inspections are not required for wood shear walls where the specified fastener spacing at panel edges is more than what maximum distance on center?
1705.12.1 Exception
Where interior exit stairways are required to be separated in a high-rise building, the separation distance shall be not less than 30 feet (9144 mm) or not less than what fraction of the length of the maximum overall diagonal dimension of the building or area served, whichever is less?
403.5.1
In each story of a separated occupancy building, the building area shall be such that the sum of the ratios of the actual building area of each separated occupancy divided by the allowable building area of each separated occupancy shall not exceed:
508.4.2
In flood hazard areas, prior to further vertical construction, the required elevation certification must be submitted to the building official upon placement of the:
110.3.3
What is the minimum required separation in hours between a nonsprinklered (NS) Group H-2 occupancy and a nonsprinklered (NS) Group H-3 or H-4 occupancy?
Table 508.4
Where weather protection is provided for outdoor hazardous material storage or use areas, walls shall not obstruct more than what portion of the structure’s perimeter?
414.6.1.1 Exception
The walls of one-story adobe buildings must be laterally supported at intervals not exceeding:
2109.2.4.4
According to Table 1405.1.1.1.2, if a combustible exterior wall covering has a tolerable level of incident radiant heat energy of 9.6 kW/m2 without exhibiting sustained flaming, what is the minimum required fire separation distance (in feet)?
1405.1.1.1.2
The design and installation of stairs, ladders, and guarding serving steel storage racks and industrial steel work platforms must be in accordance with which standard?
2213.1
The Gross Floor Area calculation includes the area within the inside perimeter of the exterior walls, without deduction for closets, the thickness of interior walls, columns or other features, but is exclusive of:
202 [BE] Floor Area, Gross
For rows of seating served by aisles or doorways at both ends, where seats have backrests, the row length limit for a minimum 12-inch clear width aisle accessway shall be increased by 0.3 inch (7.6 mm) for every additional seat beyond how many seats?
1030.13.2.1
The maximum allowable area of unprotected (UP, S) openings in a sprinklered building where the fire separation distance is 3 to less than 5 feet is:
Table 705.9
Which condition is listed as a required special inspection and test to demonstrate compliance with the listing and fire-resistance rating of SFRM?
1705.15.1 Item 4
What is the minimum thickness required for vertically erected studless solid plaster partitions made of 3/8-inch or 3/4-inch rib metal lath, 1/2-inch gypsum lath, or gypsum panel product?
2504.1.2
To be considered firmly supported, the deflection of the glass edge perpendicular to the pane must not exceed 1/175 of the glass edge length when the length is not more than:
2403.3
For structures under construction, alteration or demolition, what is the minimum hazard classification required for the sizing of portable fire extinguishers?
3309.1
What type of masonry units must be used for dry-stack masonry?
2114.3
Buildings and other structures, and parts thereof, shall be designed and constructed to support safely the factored loads in load combinations without exceeding the appropriate strength limit states for the materials of construction, which is known as:
1604.2
In flood hazard areas designated as Zone AO where a depth number is not specified on the map, the design flood elevation depth number shall be taken as being equal to:
202 [BS] Design Flood Elevation
Textile wall coverings must comply with Section 803.1.1, 803.5.1, or 803.5.2, and must be tested in the manner intended for use, including:
803.5
Where a lining of firebrick not less than 2 inches (51 mm) thick is provided in the smoke chamber walls, the total minimum thickness of front, back, and sidewalls shall be 6 inches (152 mm) of solid masonry, including the lining, and the firebrick must conform to ASTM C1261 and be laid with refractory mortar conforming to which ASTM standard?
2111.9
For a fire separation distance of 30 feet or greater, what is the allowable area for Unprotected, Nonsprinklered (UP, NS) openings?
Table 705.9
Where the inside surface of the smoke chamber is formed by corbeled masonry, the walls shall not be corbeled more than how many degrees from vertical?
2111.9.1
Which of the following is defined as an extension or increase in floor area, number of stories or height of a building or structure?
202 [A] Addition
A covered mall building or an open mall building shall be provided with emergency power capable of operating the emergency voice/alarm communication system where the total area is greater than:
402.7.3
Projections into the clear opening width of a door between 34 inches (864 mm) and 80 inches (2032 mm) above the floor or ground shall not exceed:
1010.1.1.1
Where terms are not defined in this code but are defined in the International Fire Code, such terms shall have the meanings ascribed to them as in:
201.3
Protruding objects are permitted to extend below the minimum ceiling height where a minimum headroom of what distance is provided over any circulation paths?
1003.3.1
In fire partitions that penetrate corridors where corridor ceilings are permitted, a ceiling radiation damper must be provided where which element is penetrated?
717.5.4.1
To qualify for an area factor increase based on frontage, the public way or open space must have a minimum distance of 20 feet (6096 mm) measured at right angles from the building face to which of the following?
506.3.2
As construction progresses, to within one floor of what point must the temporary or permanent stairway be extended?
3310.1
Grout used in masonry must comply with Article 2.2 of which standard?
2103.3
Institutional Group I-4 Day Care Facilities include buildings occupied by more than five persons of any age who receive custodial care for fewer than:
308.5
The maximum percentage of unprotected and protected openings in Group R-3 occupancies shall be limited to:
Table 705.9 Note d
The net free area of a spark arrestor installed on a masonry chimney shall be not less than what minimum multiple of the net free area of the chimney flue outlet it serves?
2113.9.2 Item 1
The thickness of concrete floor slabs supported directly on the ground shall be not less than:
1907.3
In Seismic Design Categories D and E, openings in floor diaphragms shall not have any dimension exceeding what maximum percentage of the distance between braced wall lines?
2308.8.4.1
What is the maximum encroachment permitted for windows, balconies, architectural features, or mechanical equipment, regardless of the calculation based on increased height above 8 feet?
3202.3.2
What is the minimum required critical radiant flux in watts per square centimeter for exposed insulation materials installed on attic floors?
720.3.1
For Group I-1, Condition 2, Group I-2, or I-3 occupancies, the egress path is permitted to pass through not more than two delayed egress locking systems, provided that the combined delay does not exceed:
1010.2.12.1 Item 5.1
Where the basic wind speed, V, is greater than 130 mph in Exposure B, nails attaching wood structural panel roof sheathing to gable-end roof framing within 48 inches of roof edges must be spaced at what maximum distance on center?
2304.10.2
The minimum width for exit passageways serving an occupant load of less than 50 shall be not less than:
1024.2
For a 40-foot container with a nominal height of 9.5 feet (Container Designation 1AAA), what is the Allowable Shear Value (PLF) for the side wall for wind or seismic loading, based on Table 3114.8.5.3?
Table 3114.8.5.3
The top surface of footings shall be level, and the bottom surface of footings shall be permitted to have a slope not exceeding:
1809.3
What is the minimum critical radiant flux classification required for interior floor finish materials in exit passageways in a Group A occupancy?
804.4.2
Atriums are NOT permitted in buildings or structures classified as:
404.1
Metal roof shingles applied to a solid or closely fitted deck shall be tested in accordance with ASTM D3161, FM 4474, UL 580 or:
1504.4.3
Amusement park structures, bleachers, and grandstands intended for viewing outdoor activities are classified as which Assembly Group?
303.6
Where photoluminescent exit path markings are installed, they shall be provided with not less than 1 footcandle (11 lux) of illumination for not less than what minimum duration prior to periods when the building is occupied?
1025.5
Where the design area of the automatic sprinkler system in a Group H-5 occupancy consists of a corridor protected by one row of sprinklers, the maximum number of sprinklers required to be calculated is:
903.2.5.2
According to Table 2114.4, what is the maximum allowable stress (psi) for compression in dry-stack masonry based on gross cross-sectional area?
2114.4
Masonry chimney walls shall be constructed of concrete, solid masonry units, or hollow masonry units grouted solid with not less than what nominal thickness?
2113.1
Wall sheathing is prohibited from being attached to framing members by which method in conventional light-frame construction?
2308.10.9
For buildings of Type IIIA construction in Groups R-1 and R-2, the maximum allowable height in Table 504.3 shall be increased by 10 feet (3048 mm) and the maximum allowable number of stories in Table 504.4 shall be increased by one, provided the first-floor assembly above the basement has a fire-resistance rating of not less than:
510.5
BIPV roof panels shall be used only on roof slopes of what minimum units vertical in 12 units horizontal or greater?
1507.17.2
Where Table 509.1 permits an automatic sprinkler system without a fire barrier, the walls separating the incidental use must be constructed to resist the passage of:
509.4.2
An uninterrupted source of power must be provided for equipment when required by the manufacturer’s instructions, the listing, this code, or which other applicable items?
2702.1.6
What collected water is prohibited from flowing over a public walking surface?
3201.4
The clear height above and below the mezzanine floor construction shall be not less than:
505.2
Where an occupiable roof is used by persons in addition to the occupants of the building, and the egress path passes through the building, means of egress requirements for the building shall be based on the sum of the occupant loads of the building plus the:
1004.7
Unlimited unprotected openings are permitted in the first story above grade plane where the exterior wall faces an unoccupied space that is not less than what minimum width?
705.9.1 Exception 1
According to Table 722.7.1(2), what is the protection contribution time in minutes provided by 5/8-inch Type X gypsum board used as noncombustible protection for mass timber?
Table 722.7.1(2)
According to Table 2113.16(1), what is the cross-sectional area (square inches) of a round flue with an inside diameter of 10 inches?
2113.16.2
According to Table 1504.8, for an aggregate-surfaced roof using ASTM D1863 (No. 6) aggregate, a mean roof height of 50 ft, and a basic wind speed (V) of 130 mph in Exposure C, what is the minimum required parapet height (in inches)?
1504.8
Where required, fire-resistant joint systems must be tested in accordance with ASTM E1966 or UL 2079. For nonsymmetrical wall joint systems, which side(s) must be exposed to the furnace during testing?
715.3.1
For rain load calculations, the hydraulic head must be based on hydraulic test data or hydraulic calculations assuming a flow rate corresponding to a rainfall intensity equal to or greater than the 15-minute duration storm with return period given in which table?
1611.1
Masonry-unit footings must be laid in Type M or S mortar and the depth shall be not less than what factor multiplied by the projection beyond the wall, pier or column?
1809.9.1
Structural capacities and design provisions for prefabricated wood I-joists must be established and monitored in accordance with which standard?
2303.1.2
Standby power for special purpose horizontal sliding, accordion, or folding doors must have a capacity to operate not fewer than how many closing cycles of the door?
2702.2.18
What term is used for wood products that exhibit reduced surface-burning characteristics and resist propagation of fire after being impregnated with chemicals by a pressure process or other means?
202 [BS] Fire-Retardant-Treated Wood
Towers, spires, domes and cupolas greater than 85 feet in height above grade plane must be constructed of and supported on Type I or II construction if they are either greater than 200 square feet in horizontal area or used for any purpose other than a belfry or an:
1511.5
When combustible building materials are delivered to a site, what is the maximum distance allowed between the fire hydrant used to provide the fire flow supply and the materials, as measured along an approved fire apparatus access lane?
3313.2
A proscenium wall with a minimum 2-hour fire-resistance rating is required where the stage height is greater than:
410.2.4
Smoke control systems shall be tested by a:
1705.19
Where Cross-Laminated Timber (CLT) is used in Type IV-HT exterior wall assemblies (2-hour rating or less), the exterior surface of the CLT must be protected by which of the following materials?
602.4.4.2
The thickness of SFRM applied to floor, roof and wall assemblies must be determined in accordance with ASTM E605, making not less than four measurements for each what size area?
1705.15.4.2
According to Table 1807.1.6.2, for a 10-foot maximum wall height, 10-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft, what is the minimum vertical reinforcement required for an 11.5-inch minimum wall thickness?
1807.1.6.2
In conventional light-frame construction, foundation sill plates must be bolted or anchored to the foundation with bolts spaced not more than what maximum distance on center?
2308.7.1
Awnings installed on detached one- and two-family dwellings are exempt from which specific fire requirements?
3105.3 Exception
What is the minimum corridor width (in inches) required for a facility not otherwise listed in the table?
Table 1020.2
What is the exception regarding elevator car doors and hoistway doors during Phase I Emergency Recall Operation?
3002.1.1 Exception
For footings cast monolithically with a slab-on-ground in Seismic Design Category C, D, E or F, how many No. 4 bars must be provided in the middle third of the footing depth, as an alternative to one bar at the top and bottom?
1905.6.2 Item 3 Exception 3
According to Table 414.2.2, what is the maximum number of control areas permitted on the second story below grade plane?
Table 414.2.2
Group III aircraft hangars containing hazardous operations, such as hot work, require a Group I or Group II fire suppression system if the total fuel capacity of all aircraft within the unsprinklered single fire area is in excess of:
412.3.6.1
Division 1.4 explosive materials, where allowed by code, shall be permitted in which High-Hazard occupancy group?
307.3.1
Unstabilized adobe units must have an average compressive strength of what minimum value when tested in accordance with ASTM C67?
2109.2.1.1
What type of joint treatment must be provided for gypsum panel product fire-resistance-rated assemblies?
2508.5
Penthouses constructed on buildings of other than Type I construction shall not exceed what maximum height above the roof deck as measured to the average height of the roof of the penthouse?
1511.2.1
Where the design wind pressure for aluminum fascia is 30 pounds per square foot or less, the fascia must be attached with one finish nail in the return leg spaced not greater than:
1412.7.1
An emergency escape and rescue opening with the bottom of the clear opening below the adjacent grade shall be provided with an area well having a minimum horizontal area of 9 square feet (0.84 m2) and a horizontal projection and width of not less than:
1031.5.1
An adult changing station shall be located on an accessible route such that a person is not more than two stories above or below the story with the adult changing station and the path of travel to such facility shall not exceed what maximum distance?
1110.4.4
What is the maximum number of seats permitted per row without backrests served by an aisle or doorway at one end only where the assembly seating contains 7,000 to 9,999 total seats?
Table 1030.13.2.1
Special inspections and tests for concrete construction are not required for isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on:
1705.3 Exception 1
The design of dry-stack masonry structures must comply with the requirements of Chapters 1 through 8 of TMS 402, except as modified by Sections 2114.2 through:
2114.1
The design of cold-formed carbon and low-alloy steel structural members not covered in Sections 2206 through 2209 must be in accordance with which standard?
2204.1
Which of the following information is NOT required to be sealed and signed by the joist manufacturer’s registered design professional?
2207.4, 2207.4.1
According to Table 1404.3(3), in Climate Zone 7, what is the minimum R-value of continuous insulation required over a 2×6 wall to permit the use of a Class III vapor retarder?
1404.3
Chimney flues connected to more than one appliance shall be not less than the area of the largest connector plus what minimum percentage of the areas of additional chimney connectors?
2113.15
Where a structure is intended to have forklifts or other movable equipment, the vehicle and wheel loads shall be increased by what percentage to account for impact?
1607.8.4.1
What components are NOT permitted to be used as a component of a required means of egress from any other part of the building?
1003.7
Where the building official issues a stop work order, who must the written order be given to?
115.2
When must an approved water supply for fire protection be made available?
3313.1
Adobe units must be laid with full head and bed joints and in full:
2109.2.4.2.2
Where installed on buildings of Types I, II, III and IV construction, metal composite material (MCM) must have a flame spread index of not more than:
1406.10.1
The emergency control station required in Group H-5 occupancies shall be continuously staffed by:
415.11.10.2
The emergency voice/alarm communication system for a building with occupant evacuation elevators must be accessible to whom?
3008.9
For stepped aisles in assembly seating without smoke protection, where egress requires stepped aisle descent, not less than 0.075 inch (1.9 mm) of additional aisle capacity for each occupant shall be provided on those portions of aisle capacity that do not have a handrail within a horizontal distance of:
1030.6.1
Plastic composite deck boards, stair treads, handrails and guards shall exhibit a flame spread index not exceeding 200 when tested in accordance with ASTM E84 or UL 723 with what condition applying to the test specimen?
2612.3
Stairways shall have intermediate handrails located such that all portions of the stairway minimum width or required capacity are within what distance of a handrail?
1014.1
The number designating the floor level on stairway identification signs shall be not less than how many inches in height and located in the center of the sign?
1023.9.1
Foundation walls of not less than 8-inch nominal width are permitted to support brick-veneered frame walls and 10-inch-wide cavity walls, provided the requirements of Section 1807.1.6.2 or which other section are met?
1807.1.6.1
Balusters, panel fillers, and guard infill components shall be designed to resist a concentrated load of:
1607.9.1.2
Edge protection barriers on ramps shall be constructed so that the barrier prevents the passage of a sphere with a diameter of 4 inches (102 mm) where any portion of the sphere is within what distance of the floor or ground surface?
1012.10.1
What is the maximum period of time in any 1 year that vestibules and storm enclosures shall be erected as temporary encroachments?
3202.4
Conveyors and related equipment connecting successive floors or levels must be enclosed with which type of construction?
3004.3.1
In commercial or industrial buildings, the design live loads must be conspicuously posted using durable signs for each floor or portion thereof designed for live loads exceeding:
106.1
For retaining walls, the design shall be based on 0.7 times nominal earthquake loads, 1.0 times other nominal loads, and investigation with one or more of the variable loads set to zero, to ensure a minimum safety factor of:
1807.2.3
Plaster shall not be applied directly to which type of board?
2511.2
Where spaced sheathing is used for wood shingles, sheathing boards shall be not less than 1-inch by 4-inch nominal dimensions and shall be spaced on centers equal to the weather exposure to coincide with the placement of:
1507.8.1
Mastic cement used to set thin exterior structural glass veneer shall be in sufficient quantity so that not less than 50 percent of the area of each glass unit is directly bonded by mastic not less than 1/4 inch thick and not more than what maximum thickness?
1404.13.3
Type A units and Type B units shall not be required for buildings without elevator service in flood hazard areas where the minimum required floor elevation results in both a difference in elevation and a slope exceeding 10 percent between the minimum required floor elevation and vehicular/pedestrian arrival points within 50 feet (15 240 mm), with the elevation difference exceeding:
1108.7.5 Item 1
Glass sloped 15 degrees (0.26 rad) or less from vertical is considered vertical glass and must be designed to resist wind loads for components and cladding in accordance with which section?
2404.1
Special inspections of welding and qualifications of special inspectors for reinforcing bars must be in accordance with the requirements of AWS D1.4 for special inspection and for:
1705.3.1
In hospitals and rehabilitation facilities (Group I-2) that specialize in treating conditions that affect mobility, what percentage of the dwelling units and sleeping units shall be Accessible units?
1108.5.4
As an alternative uniform live load reduction, for live loads not exceeding 100 psf, the reduction in percent shall not exceed 60 percent for members supporting:
1607.13.2 Item 1.2
Do plumbing fixtures located in single-user toilet facilities (including family or assisted-use) contribute toward the total number of required plumbing fixtures for a building or tenant space?
2902.1.2
Every room or space that is an assembly occupancy shall have the occupant load posted in a conspicuous place, near the main exit or exit access doorway, on a sign that must be maintained by whom?
1004.9
Where geotechnical investigations involve in-situ testing, laboratory testing, or engineering calculations, such investigations must be conducted by a:
1803.1
Gypsum plaster shall not be used on which surfaces?
2512.3
For structures with a maximum plan dimension not more than 50 feet, continuous foundations are required at which locations?
2308.10.8.1
What is the maximum projection permitted for belt courses, lintels, sills, architraves, pediments and similar architectural features below 8 feet in height?
3202.2.2
Special inspections of structural steel in the seismic force-resisting systems in structures assigned to Seismic Design Category B, C, D, E or F must be performed in accordance with the quality assurance requirements of:
1705.13.1.1
Combustible exterior wall coverings constructed of fire-retardant-treated wood complying with Section 2303.2 for exterior installation shall be permitted up to what maximum height above grade plane regardless of the fire separation distance?
1405.1.1
In Group I-2 and I-3 occupancies, an Atrium is a vertical space connecting a minimum of how many stories?
202 [BG] Atrium
For a fire partition (other than corridor walls) with a 1-hour required fire-resistance rating, what is the minimum required fire door assembly rating?
Table 716.1(2)
Whenever there is a reasonable doubt as to the structural integrity of a deep foundation element, an engineering assessment shall be required that includes tests for defects performed in accordance with ASTM D4945, ASTM D5882, ASTM D6760 or:
1705.1
Public-occupancy temporary structures assigned to which Seismic Design Categories are not required to be designed for seismic loads?
3103.6.1.4
Dampproofing materials for walls must be installed on the exterior surface of the wall, and shall extend from the top of the footing to:
1805.2.2
Smoke damper leakage ratings shall be Class I or II, and the elevated temperature ratings shall be not less than:
717.3.2.2
A dash bond coat applied to insufficiently rough masonry or concrete surfaces for proper bond must be mixed in proportions of not more than two parts volume of sand to one part volume of Portland cement or plastic cement and moist cured for not less than:
2510.7
According to Table 722.4.1(5), what is the minimum longitudinal reinforcement cover (in inches) required for a reinforced masonry lintel with a nominal width of 8 inches to achieve a 3-hour fire resistance?
Table 722.4.1(5)
All portions of an unsprinklered refrigeration machinery room shall be within what maximum distance of an exit or exit access doorway?
1006.2.2.2
What is the maximum exit access travel distance in feet for a nonsprinklered Group A, E, F-1, M, R, or S-1 occupancy?
Table 1017.2
For smoke-protected assembly seating, the total exit access travel distance shall be not greater than 400 feet (122 m), and the portion of travel from each seat to the nearest entrance to a vomitory or concourse shall not exceed:
Table 1030.6.2
Fabric partitions that exceed 6 feet in height shall resist a concentrated load of 40 pounds applied to an 8-inch-diameter area at a height of:
1607.16.1
Directional signage indicating the route to the nearest like accessible element shall be provided at which of the following locations?
1112.3
A facility designed to be occupied solely as a storm shelter (dedicated storm shelter) shall be classified as which occupancy group for determinations other than those covered in ICC 500?
423.3.1
For anchor bolts attaching a wood sill plate to concrete, anchor bolts must be located not less than what minimum distance from the edge of the concrete parallel to the length of the wood sill plate?
1905.7.2 Exception 1.4
Where a single cover sheet and truss index sheet are combined and attached to the set of truss design drawings, which document must bear the seal and signature of the truss designer?
2303.4.1.4.1 Exception
Structures and tenant spaces intended for public utilization must provide public toilet facilities for which users?
2902.3
Architectural cast stone must conform to which standard?
2103.1
The truss design drawings for cold-formed steel trusses must conform to the requirements of Section I1 of which standard?
2206.1.3.1
The structural observer must visually observe representative locations of structural systems, details and load paths for general conformance to the:
1704.6
Where compartmentation is required in an underground building, each compartment shall have not fewer than one exit and not fewer than one exit access doorway into the:
405.7.1
What must the fire service access elevator symbol (Figure 3007.6.5) contrast with, and what must the vertical center line be centered on?
3007.6.5
The provisions for underground buildings apply to building spaces having a floor level used for human occupancy more than what depth below the finished floor of the lowest level of exit discharge?
405.1
For water closets designed for assisted toileting, the centerline of the water closet shall be not less than 24 inches (610 mm) and not greater than what maximum distance from one side of the required clearance?
1110.2.2.1
What fire propagation performance criteria must membranes and interior liners meet if they are not noncombustible?
3102.3.1
Wires or cables providing power, control signals, communication, and fire-detecting systems to fire service access elevators must be protected by construction having a minimum fire-resistance rating of how long?
3007.8.1
Structural tolerances for cast-in-place concrete structural elements must be in accordance with ACI 117, with an exception for detached one- or two-family dwellings in which Group?
1901.7.1 Exception
What are the construction classifications for noncombustible membrane structures and noncombustible frame or cable-supported structures covered by an approved membrane?
3102.3
In single-ply application, edges and ends of gypsum panel products shall be in moderate contact except in concealed spaces where which of the following is not required?
2508.3
According to Table 1507.4.3, what is the minimum required thickness for Hard lead metal roof covering?
1507.4.3
According to Table 1412.6, for a wood structural panel soffit (7/16 minimum performance category) with a maximum design pressure of ± 70 psf, what is the maximum fastener spacing permitted for stainless steel along edges and intermediate supports when using an 8d common nail?
1412.6
What is the minimum number of exits or access to exits required for a story or occupiable roof with an occupant load of 501 to 1,000?
Table 1006.3.3
For horizontal building separation allowance, what is the maximum number of stories an enclosure above the horizontal assembly can connect while utilizing the exception for reduced rating (1-hour)?
510.2 Exception
In areas where the probability of termite infestation is very heavy, foam plastics shall not be installed on the exterior face or under interior or exterior foundation walls or slab foundations located below grade, unless exempted by one of three exceptions, including being installed on the interior side of what specific wall?
2603.8 Exceptions
The maximum area permitted for residential aircraft hangars is:
412.4.5
Specific information, such as test reports conducted by an approved agency, must be provided for the building official to determine that the product, material or assembly meets the applicable:
1703.4
Where restricted entrances are provided to a building or facility, at least how many restricted entrances shall be accessible?
1105.1.4
An accessible entrance is not required to which type of facility if the facility is not required to be accessible?
1105.1.7 Exception
Emergency and standby power must be provided in high-rise buildings as required in which section?
2702.2.11
When calculating the Gross Cross-Sectional Area for masonry, the area is delineated by the:
202 [BS] Gross Cross-Sectional
What is the minimum height required for the fire service access elevator symbol?
3007.6.5
Exterior window and door assemblies not covered in Section 1709.5.1 must be tested in accordance with ASTM E330, and each assembly must be tested for 10 seconds at a load equal to what factor multiplied by the design pressure?
1709.5.2
What must the strength of new welds and connections for intermodal shipping containers be relative to the original connections?
3114.8.2
Gift shops in Group I-2 occupancies shall be permitted to be open to the corridor if they and their associated storage are less than what maximum area?
407.2.4
What is the maximum occupant load permitted on a first story above grade plane of a Group H-4, H-5, I, or R-1 occupancy served by a single exit?
Table 1006.3.3
In Group R-1 occupancies, where 76 total dwelling units or sleeping units are provided, what is the total minimum required number of Accessible units?
Table 1108.6.1.1
Where access points for fire and smoke dampers are permanently identified on the exterior, the lettering must be not less than what height?
717.4.2
The design of vertical glazing shall be based on Equation 24-1, where the wind load (Fgw) is factored by:
2404.1, 2404.1
If light-transmitting plastic interior signs exceed the aggregate area limit of 24 square feet, they must be separated from each other by not less than what minimum horizontal distance?
2611.3
The approved agency shall periodically perform an inspection (in-plant if necessary) to verify that the labeled product, material or assembly is representative of the:
1703.5.2
An automatic sprinkler system is required in Group E fire areas greater than 12,000 square feet (1115 m2) in area, or if the Group E fire area has an occupant load of:
903.2.3
The exterior air intake for masonry fireplaces must be covered with a corrosion-resistant screen of what maximum mesh size?
2111.14.3
What plumbing components are permitted at the base of the hoistway enclosure?
3002.9 Exception
Where used to enclose tanks or elevators that travel to the roof level, penthouses shall be permitted to have a maximum height of what distance above the roof deck?
1511.2.1 Exception
An Emergency Escape and Rescue Opening is an operable exterior window, door or similar device that provides for a means of escape and access for:
202 [BE] Emergency Escape and Rescue Opening
Louvers protecting intake and exhaust ventilation ducts located within 30 feet of grade must meet the requirements of which standard?
1609.2.1
An automatic sprinkler system shall be provided in metallic and noncombustible nonmetallic exhaust ducts conveying flammable gases, vapors, or fumes where the largest cross-sectional diameter is equal to or greater than:
415.11.12.1
All conveying systems and their components must comply with applicable design loading criteria in Chapter 16, including which types of loads?
3001.6
Where a platform (wheelchair) lift is used as part of a required accessible route to jury boxes and witness stands, the lift must be installed in accordance with:
1110.11
Inspection of fire-resistant joint systems tested and listed in accordance with Sections 715.3.1 and 715.4 must be conducted by an approved agency in accordance with:
1705.18.2
Where minimum 1x wood furring is used to attach cladding over foam sheathing to a minimum 2x wood stud using a No. 10 wood screw, with a cladding weight of 11 psf and a fastener spacing in the furring of 16 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.2 (assuming 16 inches on center furring)?
1404.5.3.2
For a frame inspection to be made, the rough electrical, plumbing, heating wires, pipes, and ducts must be:
110.3.4
An automatic sprinkler system is required throughout all buildings containing a Group F-1 occupancy where the combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds:
903.2.4
The lettering size for permanent identification signs of fire barriers in concealed spaces must be not less than 3 inches (76 mm) in height with a minimum stroke of:
703.5
For unvented attics in Climate Zone 4A or 4B, what is the minimum R-value of air-impermeable insulation required, expressed as a percentage of the total R-value?
Table 1202.3
A radiant barrier installed above a deck shall be permitted for use where the system consisting of the radiant barrier and the roof covering complies with the requirements of UL 1256 or:
1510.2
Individual light-transmitting plastic roof panels shall be separated from each other by a distance of not less than what minimum distance measured in a horizontal plane?
2609.2
The capacity, in inches, of means of egress stairways shall be calculated by multiplying the occupant load served by a capacity factor of 0.3 inch (7.6 mm) per occupant, EXCEPT that in sprinklered buildings (other than Group H and I-2), the factor is reduced to:
1005.3.1 Exception
Where must the manufacturer’s data plate be permanently attached on or adjacent to each relocatable module?
3113.3
Foundation walls of rough or random rubble stone must be not less than what minimum thickness?
1807.1.3
Vehicle barriers for passenger vehicles shall be designed to resist a concentrated load of:
1607.11
In enclosed attics and enclosed rafter spaces, what is the minimum required airspace between the insulation and the structural roof sheathing?
1202.2.1
Metal suspension systems for acoustical and lay-in panel ceilings must comply with ASTM C635 and which section of ASCE 7 for installation in high seismic areas?
2506.2.1
In Group I-2 occupancies, the corridors in Condition 1 occupancies shall be equipped with an:
407.9
For Type H-5 fabrication areas, the minimum fire protection rating required for self-closing fire door assemblies separating the fabrication area from corridors is:
415.11.1.2 Exception 1
Where hazardous materials having a hazard ranking of 3 or 4 are transported through corridors, a manual alarm station or initiating device must be installed at not more than what interval?
415.5.2
Sprayed polyurethane foam roofs shall have a design slope of not less than what minimum units vertical in 12 units horizontal for drainage?
1507.13.1
Where occupants egress from one room through others, capacity design shall be based on the cumulative portion of occupant loads of all rooms, areas or spaces to that point along which area?
1004.2.1
Plumbing systems shall not be located in which elevator areas?
3005.6
Electrical vehicle charging stations provided to serve Group R-3 and R-4 occupancies are:
1107.2 Exception 1
What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group F-1 of Type IIA construction?
Table 504.4
Regardless of the FSI, the maximum smoke-developed index (SDI) permitted for Class A, B, or C interior wall and ceiling finish materials is:
803.1.2
In Group I-2 occupancies located in flood hazard areas, where new essential electrical system generators are installed, they must be located and installed in accordance with which standard?
2702.1.8
Until what event must the results of each daily fire safety inspection be documented and maintained on-site?
3302.3
For cold-formed steel light-frame construction, the design and installation of nonstructural members and connections must be in accordance with which standard?
2206.2
According to Table 2304.6.1, for an 8d common nail (2.5″ x 0.131″) used with 7/16-inch wood structural panel sheathing, 16-inch stud spacing, 6-inch edge nailing, and 12d field nailing, what is the maximum basic wind speed (V) permitted in Wind Exposure Category C?
2304.6.1, Table 2304.6.1
The design, testing, and utilization of steel storage racks made of cold-formed or hot-rolled steel structural members must be in accordance with which standard?
2209.1
According to Table 1808.8.2, what is the minimum concrete cover required for cast-in-place deep foundation elements not enclosed by a steel pipe, tube or permanent casing?
1808.8.2
For Residential occupancies classified as “Apartment house,” what is the required minimum number of automatic clothes washer connections?
Table 2902.1
At least what percentage of the total, but not fewer than one, of each gaming machine type and gaming table type shall be accessible?
1110.19
Modifications or changes in occupancy or use from that shown on the lease plan for a covered mall building shall not be made without prior approval of the:
402.3
Exit and exit access doorways serving refrigeration machinery rooms shall swing in the direction of egress travel and shall be equipped with panic hardware, regardless of the occupant load served, and shall be tight fitting and:
1006.2.2.2
Where a glass wall forms a smoke partition enclosing an atrium, automatic sprinklers must be located between what range of distances away from the glass?
404.6 Exception 1
What is the maximum aggregate area of all light-transmitting plastics permitted for interior signs?
2611.2
Masonry fireplaces and foundations must be anchored at each floor, ceiling, or roof line more than 6 feet (1829 mm) above grade with how many 3/16-inch by 1-inch (4.8 mm by 25 mm) straps?
2111.5
Where open or spaced wood veneers are used, they shall not project more than what maximum distance from the building wall?
1404.6
For Group R-3 buildings of Type IIB or Type VB construction, the exterior wall is NOT required to have a fire-resistance rating where the fire separation distance is:
Table 705.5 Note i
The length or height of any section of thin exterior structural glass veneer shall not exceed:
1404.13.1
According to Table 1505.1, what is the minimum roof assembly fire classification required for Type IIIB construction?
1505.1
Latex-modified Portland cement thin-set mortars used for ceramic tile installation must comply with which ANSI standard?
2103.2.3.2
Plastic signs shall be located not less than what distance from adjacent tenants?
402.6.4.3
Where handrails are not continuous between flights, the handrails shall extend horizontally not less than what distance beyond the top landing nosing?
1014.7
To resist the effects of mislocation, compressive overload of deep foundation elements is permitted to what maximum percentage of the allowable design load?
1810.3.1.3
The design of cold-formed stainless steel structural members must be in accordance with which standard?
2205.1
In flood hazard areas where design flood elevations are specified but floodways have not been designated, the cumulative effect of proposed encroachment shall not increase the design flood elevation more than:
1804.5 Item 4
Educational occupancies for students above the 12th grade, including higher education laboratories, are classified as which occupancy group?
304.1
For Type VB construction, openings in exterior walls not required to be protected by Section 705 may be glazed with light-transmitting plastic provided it complies with which section?
2608.1
Where approved by the building official, the occupant load for concentrated business use areas (like call centers or trading floors) shall be the actual occupant load, but not less than one occupant per what area?
1004.8
Interior wall and ceiling finishes within the mall of a covered mall building shall have a minimum flame spread index and smoke-developed index of:
402.6.1
In visiting areas in judicial facilities and Group I-3, at least what percentage, but not less than one of the cubicles, shall be accessible on both the visitor and detainee sides?
1110.15.1
In Dillingham, Alaska, what is the ground snow load in pounds per square foot required for a Risk Category IV building, according to Table 1608.2?
1608.2
The maximum allowable quantity for storage of Flammable Liquid Class IA (liquid) per control area is:
Table 307.1(1)
Light-transmitting plastics used as wall panels shall not be installed more than what maximum height above grade plane?
2607.3
What is the minimum required fire-resistance rating in hours for a fire wall separating Group H-1 and H-2 occupancies?
Table 706.4
Periodic special inspections of sealants or adhesives shall be conducted where sealant or adhesive required by Section 703.7 is applied to:
1705.2
What percentage chance of being equaled or exceeded in any given year defines the Base Flood?
202 [BS] Base Flood
Mortar for masonry construction must conform to Articles 2.1 and 2.6 A of which standard?
2103.2.1
For 3-inch and 4-inch sawn tongue-and-groove decking, in addition to toenailing and face-nailing to the supports, courses must be spiked to each other with 8-inch spikes at maximum intervals of:
2304.9.5.2
For mechanically fastened underlayment in high wind areas, the cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than what minimum distance into the roof sheathing?
1507.1.1
According to Table 1504.2, for a maximum basic wind speed (V) of 142 mph, what is the required ASTM D7158 classification for steep slope roof shingles?
1504.2
In Type IV-B construction, unprotected portions of mass timber walls shall be not less than what distance from unprotected portions of other walls measured horizontally along the floor?
602.4.2.2.4
Sites, buildings, structures, facilities, elements and spaces, temporary or permanent, shall be accessible to:
1103.1
Special inspection of minimum clearances in plumbing, mechanical and electrical components is not required where which component is used in sprinkler systems?
1705.13.6 Exception
The deflection of framing members supporting glass, when subjected to 0.6 times the “component and cladding” wind loads, shall not exceed 1/175 of the length of span of the framing member if the length is not more than:
1604.3.7
Insulating concrete form (ICF) material used for forming flat concrete walls must conform to which ASTM standard?
1903.3
What is the Tabular allowable area factor in square feet for a building classified as Group F-2, two or more stories above grade plane (SM) of Type IVA construction?
Table 506.2
Packages and containers of foam plastic insulation must bear the label of an approved agency showing the manufacturer’s name, product listing, product identification, and what other information?
2603.2
Structural observations must be provided for a structure assigned to Seismic Design Category E if the structure is greater than:
1704.6.1 Item 3
In a building designed as separated occupancies, the total building area for a building more than three stories above grade plane that is equipped throughout with an automatic sprinkler system (Section 903.3.1.2) shall not exceed an aggregate sum of the area ratios greater than:
506.2.2 Exception
Where earthquake loads are included in the design of retaining walls, the minimum safety factor for sliding and overturning is permitted to be reduced to:
1807.2.3 Exception
Three or more deep foundation elements connected by a rigid cap shall be considered to be braced, provided that the elements are located in radial directions from the centroid of the group not less than:
1810.2.2
For cold-formed steel light-frame construction, the design and installation of structural framing systems must be in accordance with which standard?
2206.1
What is the maximum allowable building height in feet for a building classified as Group H-4 of Type IVC construction that is equipped throughout with an automatic sprinkler system (S)?
Table 504.3
Where cladding is attached directly over foam sheathing to 43 mil cold-formed steel framing using a #10 screw, with a cladding weight of 25 psf and a fastener vertical spacing of 8 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.2.1 (assuming 24 inches on center horizontal spacing)?
1404.5.2.1
For compliance with Tables 1404.3(3) and 1404.3(4), spray foam with a maximum permeance of 1.5 perms at the installed thickness is deemed to meet the continuous insulation moisture control requirement if the spray foam R-value meets or exceeds the specified continuous insulation R-value, OR if the combined R-value of the spray foam and continuous insulation is equal to or greater than the specified:
1404.3.1
According to Table 722.2.3(2), what is the minimum concrete cover thickness (in inches) for prestressed carbonate aggregate slabs in unrestrained assemblies requiring a 4-hour fire-resistance rating?
Table 722.2.3(2)
A day care facility occupied by more than five children older than 2½ years of age, receiving educational or personal care services for fewer than 24 hours per day, is classified as which group?
305.2
An Automatic Flush Bolt is typically installed on which component of a pair of doors?
202 [BE] Automatic Flush Bolt
The occupant evacuation elevator lobby floor area must accommodate at least one wheelchair space of 30 inches by 52 inches (760 mm by 1320 mm) for each portion of the occupant load served?
3008.6.4
Periodic special inspection for architectural components is not required for interior nonbearing walls weighing what maximum weight?
1705.13.5 Exception 3
In a Group I-3 occupancy, the distance of travel to a door in a smoke barrier from any point in a room shall be not greater than:
408.6.1
Where cladding is installed directly over foam sheathing to wood framing using a 0.162-inch diameter nail, with a cladding weight of 25 psf and a fastener vertical spacing of 12 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.1 (assuming 16 inches on center horizontal spacing)?
1404.5.3.1
In Group I-3 occupancies (Conditions 3 or 4), remote release of locks on required egress doors shall be capable of being released within what maximum time period?
408.4.1
In areas not subjected to freezing, footings for masonry fireplaces must be not less than what minimum distance below finished grade?
2111.3
What is the required minimum clearance between foam plastics installed above grade and exposed earth in areas of heavy termite infestation probability?
2603.8
What is the minimum clear height required for covered walkways?
3306.7
The presumptive vertical foundation pressure for Clay, sandy clay, silty clay, clayey silt, silt and sandy silt (CL, ML, MH and CH) shall not exceed:
1806.2
Steel storage racks 8 feet in height or greater assigned to Seismic Design Category D, E or F require what type of inspection for storage rack anchorage installation?
Table 1705.13.7 Item 3
What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) Group H-1 occupancy of Type I A construction?
Table 504.4
Exposed combustible trim and sheathing may abut masonry chimney sidewalls if the combustible trim or sheathing is not less than 12 inches (305 mm) from the inside surface of the nearest flue lining, and combustible material and trim shall not overlap the corners of the chimney by more than:
2113.19 Exception 3
Where concrete is cast in a steel pipe or where an enlarged base is formed by compacting concrete, the maximum size for coarse aggregate shall be:
1810.3.2.1
Semiconductor fabrication facilities where hazardous production materials (HPM) are used in excess of the Maximum Allowable Quantities shall be classified as which High-Hazard Group?
307.7
An exterior wall assembly must be constructed to prevent water accumulation by providing a water-resistive barrier behind the exterior veneer and a means for draining water that enters the assembly to the:
1402.2
For Asphalt shingles installed on a roof slope between 2:12 and 4:12 where the maximum basic wind speed (V) is less than 130 mph, the two layers of underlayment shall overlap successive sheets half the width of a full sheet plus:
1507.1.1
For horizontal building separation allowance, the horizontal assembly separating the buildings must have a fire-resistance rating of not less than:
510.2
If the building official serves a written notice for an unsafe condition, the notice shall require the notified person to declare immediately to the building official their acceptance or rejection of the terms of the:
116.3
The egress analysis for evacuation of the five consecutive floors with the highest cumulative occupant load must demonstrate that the number of evacuation elevators results in an evacuation time less than what maximum duration?
3008.1.1
For enclosures for shafts, interior exit stairways, and interior exit ramps with a 2-hour required fire-resistance rating, what is the maximum permissible area for a door vision panel in square inches?
Table 716.1(2)
What is the maximum nominal thickness of ice loads permitted to be used for the design of public-occupancy temporary structures for all risk categories?
3103.6.1.5
What is the maximum exit access travel distance in feet for a sprinklered Group H-1 occupancy?
Table 1017.2
Inlets to masonry chimneys must enter from the side and must have a thimble of fireclay, rigid refractory material, or metal that will prevent the connector from pulling out of the inlet or from extending beyond the wall of the:
2113.17
For a fire barrier with a 2-hour required fire-resistance rating, what is the minimum required fire door assembly rating in hours?
Table 716.1(2)
Fire department connections to automatic sprinkler systems or standpipes must have threads that are compatible with the connections used by the:
901.4
The thickness of foam plastic signs used in a mall shall not be greater than:
402.6.4.5.2
What is the maximum allowable building height in feet for a Type IIB construction building classified as Group E that is equipped throughout with an automatic sprinkler system (S)?
Table 504.3
Second-hand masonry units shall not be reused unless they conform to the requirements of new units and:
2103.1.1
Vertical and lateral flame propagation requirements apply to exterior walls on buildings of Type I, II, III and IV construction that contain a combustible exterior wall covering, combustible insulation or a combustible:
1402.5
For roof planking that uses end-matched or splined 2-inch tongue-and-groove planking with randomly spaced joints, the system must be applied to not less than how many continuous spans?
2308.11.11
Intermediate nailing strips are required for vinyl and aluminum soffit panels where the unsupported span is greater than 16 inches and the design wind pressure is:
1412.3
The total area of one or more vision panels in any elevator hoistway door shall be not more than:
2409.3
Greenhouses that are occupied for growing or maintaining plants, without public access, are exempt from the area limitations of Table 2609.4 provided they have a minimum fire separation distance of:
2609.4 Exception
An automatic sprinkler system protecting a Group H occupancy must be monitored by an approved supervising station in accordance with:
901.6.1
For concrete foundation walls designed using Table 1807.1.6.2 in Seismic Design Categories A and B, not less than one No. 5 bar must be provided around window, door and similar sized openings, and the bar shall be anchored to develop fy in tension at the:
1807.1.6.2.1
Nondestructive testing of structural steel in the seismic force-resisting systems in structures assigned to Seismic Design Category B, C, D, E or F must be performed in accordance with the quality assurance requirements of:
1705.14.1.1
For air-supported and air-inflated structures required to have a support system in the event of deflation, what is the minimum height the support system must maintain the membrane above the floor, seating area, or surface of the water, for membranes other than those used as a roof for Type I construction?
3102.8.3
At least what percentage, but not less than one, of care recipient and visitor parking spaces serving rehabilitation facilities specializing in treating conditions that affect mobility shall be accessible?
1106.5
According to Table 1507.4.3, what is the minimum thickness required for Aluminum used for roll-formed metal roof panels?
1507.4.3
Plaster applied to adobe masonry must be not less than 7/8 inch (22 mm) and not greater than what maximum thickness?
2109.2.4.8.3
Exposure D shall apply where Surface Roughness D prevails in the upwind direction for a distance of not less than 5,000 feet or:
1609.4.3
Appliances located in public garages or repair garages shall be installed not less than what height above the floor?
406.2.9.2
According to Table 1507.9.8, what is the maximum weather exposure (in inches) permitted for 18-inch, Grade No. 2 preservative-treated taper sawn shakes of Southern yellow pine installed on a 4:12 pitch or steeper?
1507.9.8
In repair garages used for vehicles fueled by nonodorized gases, activation of a gas detection alarm shall result in the deactivation of all:
406.8.2.1
Stabilized adobe units must be used in adobe walls for the first what minimum distance above the finished first-floor elevation?
2109.2.4.5.2
Rectangular tread depths shall be what minimum distance measured horizontally between the vertical planes of the foremost projection of adjacent treads?
1011.5.2
Fasteners for asphalt shingles shall have a minimum 12-gage shank, a minimum 3/8-inch-diameter head, and be of a length to penetrate through the roofing materials and not less than what minimum distance into the roof sheathing?
1507.2.5
In Type IV-B construction, unprotected portions of mass timber walls are limited to an area less than or equal to what percentage of the floor area in any dwelling unit or fire area within a story?
602.4.2.2.2 Exception 1.2
Where stadiums, arenas and grandstands have how many fixed seats or more and provide audible public announcements, they shall also provide captions of those announcements?
1109.2.7.3
According to Table 1705.3, what type of special inspection is required to inspect reinforcement, including prestressing tendons, and verify placement?
Table 1705.3 Item 1
For structures assigned to Seismic Design Category D, E or F, the geotechnical investigation must include the determination of dynamic seismic lateral earth pressures on foundation walls and retaining walls supporting more than what minimum height of backfill due to design earthquake ground motions?
1803.5.12 Item 1
Raised thresholds and floor level changes greater than 1/4 inch (6.4 mm) at doorways shall be beveled with a slope not greater than:
1010.1.6
Where plumbing fixtures are required, separate facilities must be provided for each sex, unless what maximum total occupant load exists in the structures or tenant spaces (including both employees and customers)?
2902.2 Exception
Where excavation will reduce support from any foundation, who must prepare an assessment of the structure?
1803.5.7
For an interior exit stairway and ramp connecting less than four stories, the minimum fire-resistance rating shall be not less than:
1023.2
Gypsum panel products and accessories must be stored to protect such materials from the:
2506.1
The required fire-resistance rating in hours for a fire barrier separating a single occupancy into fire areas for Group A, B, E, F-2, H-4, H-5, I, M, R, or S-2 is:
Table 707.3.10
Where must the fire service access elevator be continuously monitored?
3007.7
If a room in a building has a sloped ceiling, any portion of the room measuring less than what distance from the finished floor to the ceiling shall not be included in any computation of the minimum area?
1208.2 Exception 2
Structural concrete slabs-on-ground are considered structural concrete where required by ACI 318 or where designed to transmit vertical loads or lateral forces from other parts of the structure to the soil or to:
1907.1
In general occupancies, public drinking fountains shall be located within a distance of travel of 500 feet (152 m) of the most remote location in the tenant space and not more than how many stories above or below the tenant space?
2902.5
Floor-ceiling assemblies between dwelling units or sleeping units shall have an Impact Insulation Class (IIC) rating of not less than what value when tested in accordance with ASTM E492?
1206.3
The path of egress travel measured from the most remote point of each room to the point where occupants have separate and distinct access to two exits is the:
202 [BE] Common Path of Egress Travel
In a safe dispersal area required because access to a public way cannot be provided, the area shall be of a size to accommodate not less than what minimum area for each person?
1028.5 Exception 1
A sign notifying patrons of the availability of assistive listening systems shall include which specific symbol?
1112.4 Item 1
Sprinkler protection is NOT required at the ceiling of an atrium where the ceiling of the atrium is more than what height above the floor?
404.3 Exception
According to Table 1509.2, which ASTM standard applies to Aluminum-pigmented asphalt coating?
1509.2
According to Table 1705.7, for steel driven deep foundation elements, additional special inspections must be performed in accordance with which section?
Table 1705.7 Item 5
The contractor’s written statement of responsibility, submitted prior to the commencement of work, must contain acknowledgement of awareness of the special requirements contained in the:
1704.4
According to Table 2114.4, what is the maximum allowable stress (psi) for flexural tension in the horizontal span of dry-stack masonry?
2114.4
In determining dead loads, the weight of fixed service equipment, including the maximum weight of the contents, shall be included. Components that are variable, such as liquid contents, shall not be used to counteract forces causing overturning, sliding, and:
1606.3
Buildings for more than 16 persons, excluding staff, who reside on a 24-hour basis in a supervised environment and receive custodial care (such as assisted living facilities), are classified as which Institutional Group?
308.2
What is the required interior wall and ceiling finish classification for rooms and enclosed spaces in a sprinklered Group H occupancy?
Table 803.13
In Group R-3 occupancies and dwelling units in Group R-2, where an incline platform lift or stairway chairlift is installed, a clear passage width not less than what distance shall be provided?
1011.2 Exception 3
Emergency or standby power is required for gas detection systems in accordance with which code?
2702.2.7
For siding backer board, foam plastic insulation is permitted without a thermal barrier if its heat potential does not exceed 2,000 Btu/sq. ft. (22.7 mJ/m2), the maximum thickness is 1/2 inch, and it is separated from the interior by not less than:
2603.4.1.10
Vinyl siding must be certified and labeled as conforming to the requirements of:
1403.8
What material is accepted as an approved thermal barrier, having a thickness of 1/2 inch (12.7 mm)?
2603.4
On buildings of Type I construction, the exterior walls and roofs of penthouses with a fire separation distance greater than 5 feet and less than 20 feet shall be permitted to have not less than what minimum fire-resistance rating?
1511.2.4 Exception 1
For a stage requiring emergency ventilation via roof vents, the aggregate clear opening area of the vents must be not less than what percentage of the area of the stage?
410.2.7.1
Detached one- and two-family dwellings are excepted from comprehensive seismic design requirements if they are assigned to which Seismic Design Categories?
1613.1 Exception 1
Who is responsible for the development, implementation and maintenance of an approved, written site safety plan?
3302.1
Nosings shall have a curvature or bevel of not less than 1/16 inch (1.6 mm) but not more than what maximum distance from the foremost projection of the tread?
1011.5.5
Built-up, modified bitumen, single-ply roof systems, metal panel roof systems applied to a solid deck, and other membrane roof coverings shall be tested in accordance with FM 4474, UL 580 or:
1504.4.1
Where four or more elevator cars serve the same portion of a building, into how many separate fire-resistance-rated hoistways must the elevators be located?
3002.2
What is the minimum required clearance from the curb line for stanchions or columns that support awnings, canopies, marquees and signs?
3202.3.1
What is the minimum vertical attachment flange required for a corrosion-resistant weep screed?
2512.1.2
Adobe construction is limited to buildings not exceeding one story, except that two-story construction is allowed where designed by a:
2109.2.4.1
The minimum thickness of exterior walls in one-story adobe buildings shall be:
2109.2.4.4
When the sprinkler protection is being regularly turned off and on to facilitate connection of newly completed segments, when must the sprinkler control valves be checked?
3312.2
For design thicknesses 1 inch or greater, the minimum allowable individual SFRM thickness shall be the design thickness minus:
1705.15.4.1
For manual revolving doors with a maximum nominal diameter of 8 feet, what is the maximum allowable revolving door speed in RPM?
Table 1010.3.1(1)
A child day care facility providing care for more than five but not more than 100 children 2½ years or less of age, where rooms have an exit door directly to the exterior, shall be classified as which group?
308.5.1
For foam plastic insulation used as part of a roof-covering assembly, the assembly must be a Class A, B or C roofing assembly when tested in accordance with ASTM E108 or which other standard?
2603.6
What is the required minimum width for public ways or yards surrounding a one-story aircraft hangar provided with an automatic fire-extinguishing system to qualify for unlimited building height?
504.1 Exception
Interior walls and partitions that exceed 6 feet in height shall resist a horizontal load of not less than:
1607.16
Where required, the automatic secondary on-site water supply for high-rise buildings shall have a duration of not less than:
403.3.3
BIPV shingles shall be installed on roof slopes of not less than what minimum units vertical in 12 units horizontal?
1507.16.2
Which standard governs the material for Nonasbestos fiber-cement backer board?
Table 2509.2
Which class of combustible liquid has a closed cup flash point at or above 140°F (60°C) and below 200°F (93°C)?
202 [F] Class IIIA
Ground-mounted photovoltaic (PV) panel systems are not required to accommodate which type of load?
1607.22.4
Nails used for framing and sheathing connections with shank diameters between 0.099 inch and 0.142 inch must have a minimum average bending yield strength of:
2303.6
Glass used in a handrail or a guard must be laminated glass constructed of fully tempered or heat-strengthened glass and shall have a minimum nominal thickness of:
2407.1
For a pair of doors required to comply with Section 716 (fire doors) in a Group B, F, or S occupancy serving less than 50 people, which type of latching device is Permitted on the inactive leaf?
Table 1010.2.4
When combustible building materials are delivered to a site, what is the minimum required fire flow?
3313.2
Self-adhered membranes used as flashings of fenestration in exterior wall assemblies must comply with which standard?
1404.4
Structural plain concrete walls below the base in dwellings assigned to Seismic Design Category D or E shall have a thickness of not less than:
1905.6.2 Item 1
At beams and girders, thickness measurements of SFRM shall be made at how many locations around the beam or girder at each end of a 12-inch length?
1705.15.4.6
What is the maximum size permitted for a steel box used to terminate an electrical raceway serving the interior exit stairway and ramp as a permitted penetration?
1023.5
Joints in wood tie beams for adobe construction must be spliced not less than 6 inches (152 mm), and splices shall not be allowed within what minimum distance of an opening?
2109.2.4.7.2
In Group I-2 occupancies, a laundry room over 100 square feet requires what separation and/or protection?
Table 509.1
Means of egress ramps shall have a minimum headroom clearance of not less than what distance above the finished floor of the ramp run?
1012.5.2
Detached one- and two-family dwellings and townhouses, less than or equal to three stories above grade plane, are permitted to be constructed in accordance with which standard, subject to the limitations therein?
2206.1.2
Glazing adjacent to a door is considered hazardous if the nearest vertical edge is within a 24-inch (610 mm) arc of the door edge, and the bottom exposed edge is less than what maximum height above the walking surface?
2406.4.2
A water-resistive barrier material complying with ASTM E2556, Type I or II, shall be permitted as one of the required layers, provided the material complies with Section 1403.2 or is an:
1403.2
If foam plastic insulation is granted special approval based on large-scale tests such as FM 4880 or UL 1040, what requirement is it exempted from complying with?
2603.9
According to Table 414.5.1, what specialized safety measure is required for Division 1.2 explosives?
Table 414.5.1
Curtains, draperies, fabric hangings and similar combustible decorative materials required to exhibit improved fire performance must meet the flame propagation performance criteria of Test 1 or 2 of NFPA 701, or exhibit a maximum heat release rate of:
806.4
The path of egress travel within and from technical production areas shall be not less than:
410.5.3.5
Insulated Vinyl Siding must have a thermal resistance of the cladding product not less than:
202 [BF] Insulated Vinyl Siding
In under-floor spaces with the ground surface covered with a Class I vapor retarder, the net area of ventilation openings shall be not less than 1 square foot for each how many square feet of crawl space area?
1202.4.1.2
Special inspections are not required for wood shear walls in the seismic force-resisting system where the specified fastener spacing at the panel edges is more than what maximum distance on center?
1705.13.2 Exception
In multipane glazed assemblies, individual panes not exceeding 1 square foot (0.09 m2) in exposed area must have one pane or more marked per Section 2406.3, and other panes must be marked “CPSC 16 CFR Part 1201” or:
2406.3.1
Which standard governs belt manlifts?
Table 3001.3
Dead-end corridors in sprinklered Groups B, E, F, I-1, M, R-1, R-2, S, and U shall not exceed what maximum length?
1020.5 Exception 2
According to Table 1404.15.2, for an ultimate design wind speed of 115 MPH (Case 1, with interior gypsum wallboard), what is the adjusted minimum design wind pressure (ASD) in psf required for vinyl siding installed over foam plastic sheathing alone in Exposure C?
1404.15.2
For Group H occupancies, the supervision and monitoring of emergency alarm, detection and automatic fire-extinguishing systems shall be in accordance with the:
901.6.3
At each separate-sex toilet and bathing room, directional signage indicating the location of the nearest family/assisted use toilet or bathing room shall be provided where the family/assisted use room is provided in accordance with which section?
1112.3 Item 4
For reinforced gypsum concrete, the minimum required thickness shall be 2 inches (51 mm), but is permitted to be reduced to 1 1/2 inches (38 mm), provided the clear span between supports does not exceed 33 inches, diaphragm action is not required, and the design live load does not exceed:
2514.2
Periodic special inspection shall be provided for seismic isolation systems during the fabrication and installation of isolator units and:
1705.13.8
The required development length of reinforcement need not be greater than what maximum multiple of the bar diameter?
2108.2
Special inspections of the steel fabrication process are not required where the fabrication process for the entire building does not include any welding, thermal cutting or:
1705.2 Exception
Loads and load combinations on storm shelters shall be determined in accordance with which standard?
1604.1
Construction materials and equipment shall not be placed or stored so as to obstruct access to fire hydrants, standpipes, or within what maximum distance of a street intersection?
3308.1.1
In Group R-3 occupancies (and R-2 dwelling units not required to be accessible), the maximum stair riser height shall be:
1011.5.2 Exception 3
What is the maximum distance steps are permitted to project into the public right-of-way if they are guarded by approved devices not less than 3 feet (914 mm) in height or located between columns or pilasters?
3202.2.1
Interior wall and ceiling finish materials having a thickness less than 0.036 inch (0.9 mm) applied directly to the surface of walls or ceilings are exempt from what requirement?
803.2
What is the maximum allowable building height in feet for a building classified as Group R (new) of Type IIIA construction that is equipped throughout with an automatic sprinkler system (S)?
Table 504.3
Which type of glass, if used in louvered windows or jalousies, shall not have wire exposed on longitudinal edges?
2403.5
Where doors serving rooms with electrical equipment rated 800 amperes or more are less than 25 feet (7620 mm) from the equipment working space, they shall not be provided with a latch or lock other than:
1010.2.8.2
For library stack rooms designed using the load specified in Table 1607.1, the nominal shelf depth shall not exceed what maximum dimension for each face?
1607.17
According to Table 414.2.2, what is the required fire-resistance rating for fire barriers separating control areas on the sixth story above grade plane?
Table 414.2.2
For chimneys up to 40 inches (1016 mm) wide in Seismic Design Category C or D, how many continuous No. 4 vertical bars must be provided?
2113.3.1
For structural steel frame structures designed using Allowable Stress Design (ASD), end connections of all beams and girders must have a minimum nominal axial tensile strength equal to the required vertical shear strength but not less than:
1616.2.2.2
Group S-1 Moderate-Hazard Storage includes, but is not limited to, the storage of which of the following items?
311.2
Mechanical equipment screens shall not exceed what maximum height above the roof deck, as measured to the highest point on the screen?
1511.6.1
In cooler and freezer walls, foam plastic up to 10 inches thick must have flash ignition and self-ignition temperatures of not less than what minimum temperatures, respectively?
2603.4.1.2
For glass handrails and guards, calculated stresses for specified loads shall be less than or equal to 3,000 pounds per square inch (20.7 MPa) for heat-strengthened glass and less than or equal to what maximum value for fully tempered glass?
2407.1.1
Where open parking garages are constructed to heights less than the table maximum, allowable tier areas may be increased, provided not fewer than how many sides of each such larger tier have continuous horizontal openings?
406.5.5
In Group A occupancies having an occupant load of 300 or less, key-operated locking devices are permitted on the main exterior doors provided a sign is posted on the egress side stating “THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED.” What is the minimum required letter height for this sign?
1010.2.4 Item 3.3
According to Table 1404.15.2, for an ultimate design wind speed of 105 MPH (Case 2, without interior gypsum wallboard), what is the adjusted minimum design wind pressure (ASD) in psf required for vinyl siding installed over foam plastic sheathing alone in Exposure B?
1404.15.2
The means of egress shall have a ceiling height of not less than what distance above the finished floor?
1003.2
In Group B, M, or R-1 occupancies, if the building occupant load is greater than what threshold, accessible public entrances must have a power-operated door or a low-energy power-operated door?
Table 1105.1.1
How shall waste materials be removed?
3301.5
The maximum area permitted for each kiosk or similar structure or groupings thereof located within a mall is:
402.6.2
The weep screed shall be placed not less than 4 inches (102 mm) above earth or what minimum distance above paved areas?
2512.1.2
In Group I-1, Condition 1 occupancies, at least what percentage, but not less than one, of the dwelling units and sleeping units shall be Accessible units?
1108.5.1.1
For buildings two stories or less above grade plane, what is the minimum required width of a yard?
1205.2
Emergency escape and rescue openings shall be provided in basements and sleeping rooms below which story above grade plane?
1031.2
Empirical design requirements for adobe masonry shall not apply to the design or construction of masonry where the Allowable Stress Design wind speed, exceeds what maximum speed?
2109.1.1
In Group R-2 college dormitories, which domestic cooking appliance shall NOT be installed or used in sleeping rooms?
420.11.2
When a flue is relined with a material not complying with Section 2113.11.1, the chimney must be plainly and permanently identified by a label attached to a wall, ceiling, or other conspicuous location adjacent to where the connector enters the chimney, which includes notice of the specific type or category of appliance and:
2113.11.1.5
For pedestrian walkways with open sides connecting the third or lower story of each building (and not protected by sprinklers), what is the maximum height the roof of the walkway can be above grade plane?
3104.5.3
A Computer Room is a room used primarily to house information technology equipment (ITE) and serving an ITE load less than or equal to 10 kW or what conditioned floor area load?
202 [BG] Computer Room
The aggregate area of a mezzanine or mezzanines within a room shall be not greater than what fraction of the floor area of that room or space?
505.2.1
Sheet metal clamps, ties, or clips used to ensure a continuous load path where wall framing members are not continuous must be formed of galvanized steel or other corrosion-resistant material not less than what minimum base metal thickness?
2304.10.7
An accessible route shall connect each accessible story, mezzanine, and occupiable roofs in multilevel buildings and facilities, EXCEPT where these areas have an aggregate area of not more than:
1104.4 Exception 1
Dwelling units shall have a minimum of how many square feet of habitable space?
1208.3
Surface Roughness C, for the purpose of assigning an exposure category, is defined as open terrain with scattered obstructions having heights generally less than:
1609.4.2
Concrete and clay roof tiles shall be tested to determine their resistance to overturning due to wind in accordance with Chapter 15 and either SBCCI SSTD 11 or which ASTM standard?
1504.3.1.1
The special inspection of masonry must be as defined in Chapter 17, or an itemized testing and inspection program must be provided that meets or exceeds the requirements of:
2101.3
Ambulatory Care Facility refers to a building used to provide care on a less than 24-hour basis to persons who are rendered incapable of self-preservation by the services provided or staff has accepted responsibility for:
202 [BG] Ambulatory Care Facility
Openings between anchor buildings of Type IA construction and the mall need not be protected, except for the separation between Group R-1 sleeping units and the:
402.4.2.2.1
Each required area of refuge shall be sized to accommodate one wheelchair space (30 inches by 52 inches) for each how many occupants or portion thereof, based on the occupant load?
1009.6.3
Within each individual tenant space in a covered or open mall building, the distance of travel from any point to an exit or entrance to the mall shall be not greater than:
402.8.5
According to Table 1705.3, inspecting single-pass fillet welds up to 5/16-inch maximum requires which type of inspection?
Table 1705.3 Item 2.e
For a through penetration firestop system in a fire-resistance-rated wall, the system must have an F rating of not less than:
714.4.1.2
When exterior wall assemblies are required to comply with the acceptance criteria of NFPA 285, compliance shall be established by testing, an approved design listed by an approved agency, or an approved analysis based on an assembly or condition tested in accordance with NFPA 285, as specified in:
1402.8
Swales used for diverting water away from the foundation must be sloped not less than 2 percent where located within what maximum distance of the building foundation?
1804.4
For membrane-covered frame structures, what element shall not be considered to provide lateral restraint when calculating the capacities of the frame members?
3102.7.1
In buildings required to have standpipes by Section 905.3.1, when must they be installed prior to construction?
3311.1
Structural clay tile for nonstructural use in fireproofing structural members and wall furring is excepted from meeting which requirement?
2103.1 Exception
Glass fiber-reinforced concrete (GFRC) and its materials must be in accordance with which standard?
1903.2
What is the maximum Frontage Increase Factor when a building that does not meet Section 507 requirements has 80 percent of its perimeter on an open space of 35 feet?
Table 506.3.3
Wood structural panels used for opening protection in R-3 or R-4 occupancies shall have a minimum thickness of:
1609.2 Exception 1
According to Table 1404.2, what is the minimum nominal thickness required for vinyl siding?
1404.2
Pedestrian walkways separated from the interior of the building by fire barriers must have those fire barriers constructed with what minimum fire-resistance rating?
3104.5.1
Uplift connection requirements listed in Table 2308.11.4 for the corner of the building are permitted to be reduced for connections located 20 percent or more of the least horizontal dimension from the corner by multiplying the table value by what factor?
2308.11.4
Fasteners for lath used on adobe masonry walls must be corrosion resistant and spaced at a maximum of 16 inches (406 mm) on center with a minimum penetration into the adobe wall of:
2109.2.4.8.5
Where accessible parking is provided, how many accessible spaces are required for a parking facility providing 350 total parking spaces?
Table 1106.2
For alternating tread devices, the minimum tread depth shall be 5 inches (127 mm), and the maximum riser height shall be:
1011.14.2
On buildings of Type I, II, III or IV construction, mechanical equipment screens constructed of combustible materials are permitted if the fire separation distance is not less than 20 feet and the height of the screen above the roof deck shall not exceed:
1511.6.2
Which alternative allowable stress load combination is represented by 0.9D + E/1.4?
1605.2
A change in use of an elevator (e.g., from freight to passenger, or between freight classes) must comply with which standard and section?
3001.5
According to Table 1507.8.7, what is the maximum weather exposure (in inches) permitted for 18-inch, Grade No. 1 wood shingles of naturally durable wood installed on a 4:12 pitch or steeper slope?
1507.8.7
What is the minimum required fire-resistance rating in hours for exterior bearing walls in a Type IIIA building?
Table 601
What is the minimum required net free ventilating area for enclosed attics and enclosed rafter spaces?
1202.2.1
Unlisted combustion air ducts for masonry fireplaces must be installed with a minimum 1-inch (25 mm) clearance to combustibles for all parts of the duct within what maximum distance of the duct outlet?
2111.14.4
For glazing in windows to be a hazardous location (Section 2406.4.3), one or more walking surface(s) must be within what maximum horizontal distance of the plane of the glazing?
2406.4.3
For business and mercantile classifications, a service sink is not required if the occupant load is what maximum number?
2902.1 Note
When are existing means of egress systems not required to be maintained during construction, demolition, remodeling, alterations, or additions?
3310.2 Exception
In Climate Zones 6, 7, and 8, upper ventilators that provide the reduced net free cross-ventilation area must be located not more than what distance below the ridge?
1202.2.1 Exception
For a chemical to be classified as Highly Toxic via oral administration, it must have a median lethal dose (LD50) of how many milligrams or less per kilogram of body weight to albino rats?
202 [F] Highly Toxic
The scope of the geotechnical investigation, including the number and types of borings, must be determined by a:
1803.3.1
Plaster and finish assemblies applied to adobe walls must have a vapor permeance of not less than:
2109.2.4.8.2
Vehicular gates intended for automation must be designed, constructed, and installed to comply with which standard?
3110.2
For water closets designed for assisted toileting, the clearance around the water closet shall be not less than 78 inches (1980 mm) in depth, measured perpendicularly from:
1110.2.2.2.2
A fire watch shall be provided for new multistory construction with an aggregate area exceeding what maximum size per story?
4645 m2
At least one of each type of exercise machine and equipment shall be on an:
1111.4.10
Clay flue liners must extend from a point not less than 8 inches (203 mm) below the lowest inlet or, in the case of fireplaces, from the top of the smoke chamber to a point above the:
2113.12
Where the fire separation distance is 5 feet or less, the area of high-pressure decorative exterior-grade compact laminates (HPL) installed up to 40 feet in height above grade plane shall not exceed what maximum percentage of the exterior wall surface?
1408.11.1.1
A “cast-in-place concrete equivalent diaphragm” is defined as a cast-in-place noncomposite topping slab diaphragm, or a diaphragm constructed with precast concrete components that uses closure strips between precast components with detailing that meets the requirements of ACI 318 for the:
1905.2
Where the ratio of the depth of embedment of a deep foundation element to its least horizontal dimension is less than or equal to six, it shall be permitted to assume the element is:
1810.2.4
In Climate Zones 6, 7, and 8, the net free cross-ventilation area is permitted to be reduced to 1/300, provided at least what minimum percentage of the required venting area is provided by upper ventilators?
1202.2.1 Exception
The building area of a covered mall building shall not be limited provided that the construction type is Type I, II, III, or IV and the building does not exceed:
402.4.1.1
Where multiple single-user toilet rooms or bathing rooms are clustered at a single location, at least what percentage, but not less than one room for each use at each cluster, shall be accessible?
1110.2 Exception 3
Signs identifying accessible toilet or bathing rooms where not all such rooms are accessible shall include the:
1112.1 Item 4
In Type IV-C construction, the exterior side of walls of combustible construction must be protected with noncombustible protection having a minimum assigned time of:
602.4.3.1
Which type of power system is an acceptable alternative for installations that require standby power systems?
2702.1.7
A live/work unit is permitted to be not greater than what maximum area?
508.5.1
Where deep foundations are used, the geotechnical investigation must include all of the items listed in Section 1803.5.5, including recommended center-to-center spacing of deep foundation elements and:
1803.5.5
Where accessible parking is provided for a parking facility providing 1,500 total parking spaces, how many accessible spaces are required?
Table 1106.2
Fiber-cement siding attached to wood studs must have nails long enough to penetrate the studs not less than:
1404.17
Walls and floor-ceiling assemblies separating dwelling units from each other shall have a Sound Transmission Class (STC) of not less than:
1206.2
The aggregate width of openings at any floor level through a fire wall shall not exceed what percentage of the length of the wall?
706.8
What is the maximum interval (in days) between follow-up inspections by a qualified person after initial occupancy of a public-occupancy temporary structure granted an extended period of service time?
3103.1.1
Clay flue liners must be laid in medium-duty nonwater-soluble refractory mortar conforming to ASTM C199 with tight mortar joints left smooth on the inside and installed to maintain an airspace or insulation not to exceed the thickness of the flue liner separating the flue liners from the interior face of the:
2113.12
An engineering analysis and load test of construction, when required by the building official, shall be conducted in accordance with which section?
1604.6
For exterior walls of buildings of Type I, II, III or IV construction, the potential heat of foam plastic insulation in any portion of the wall must not exceed the potential heat of the foam plastic insulation contained in the wall assembly tested in accordance with which section?
2603.5.3
A vertical plastic sign affixed to a storefront facing a mall shall be not greater than 96 inches (2438 mm) in height and the width shall be not greater than:
402.6.4.2
Supplemental information submitted for a relocatable building must include, at a minimum, what information regarding site-built attachments?
3113.2
What is the maximum number of stories an unconcealed vertical opening totally within an individual residential dwelling unit can connect without requiring a shaft enclosure?
712.1.2
Exposed portions of building elements complying with the requirements for heavy timber construction are NOT subject to interior finish requirements, EXCEPT in:
803.3
Excluding noncombustible membrane structures serving as roofs only, what is the maximum height limitation for membrane structures?
3102.5, 3102.5 Exception
Where minimum 1x wood furring is used to attach cladding over foam sheathing to a minimum 2x wood stud using a 0.131-inch diameter nail, with a cladding weight of 18 psf and a fastener spacing in the furring of 8 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.2 (assuming 16 inches on center furring)?
1404.5.3.2
A Flammable Liquid Class IA must have a flash point below 73°F (23°C) and a boiling point below:
202 [F] Class IA
Where a structure is proposed for a purpose that is not specified, it shall be classified in the occupancy it most nearly resembles based on the fire safety and:
302.1
Special inspections and tests are not required for masonry fireplaces installed or constructed in accordance with which section?
1705.4 Exception 3
The ends of wood girders entering exterior masonry or concrete walls must be provided with a minimum airspace of:
2304.12.2.1
According to Table 1507.12.2, which material standard applies to Thermoplastic polyolefin (TPO) single-ply roof coverings?
1507.12.2
Where multiple-user facilities are designed to serve all genders, the minimum fixture count shall be calculated based on what percentage of the total occupant load?
2902.1.1 Exception
An opening shall be provided to any attic area having a clear height of over 30 inches (762 mm). What is the minimum size of this opening?
1209.2
Ground-mounted photovoltaic panel systems are required to be designed and installed in accordance with Chapter 16 and which other code?
3111.3.6
Deep foundation elements standing unbraced in air, water or fluid soils must be classified as columns and designed as such down to the point where adequate lateral support is provided in accordance with:
1810.1.3
Any material, appliance, equipment, system or method of construction meeting the requirements of this code shall be approved in writing after satisfactory completion of required tests and submission of:
1703.2
According to Table 3306.1, if the construction height is 8 feet or less and the distance to the lot line is 5 feet or more, what type of protection is required?
Table 3306.1
Continuous special inspection is required during field gluing operations of elements of the:
1705.12.1
The design, fabrication, and erection of structural steel elements and composite structural steel and concrete elements in buildings must be in accordance with which standard?
2202.1
Insulated metal panel (IMP) systems used as exterior wall covering systems shall be designed and constructed to resist wind loads as required by which section?
1409.2.2
For trusses spanning 60 feet or greater, who must contract a registered design professional for the design of the temporary installation restraint/bracing and the PITMR and PITMDB?
2303.4.1.3
For buildings more than two stories above grade plane, the minimum width of the yard must be increased at the rate of 1 foot (305 mm) for each additional story, up to a maximum number of stories based on:
1205.2
The minimum depth of footings below the undisturbed ground surface shall be:
1809.4
Fire testing of a raised-deck system is not required where the decking or pavers of the system consists of brick, masonry, concrete or other:
1511.9.2.1 Exception
For helicopter landing areas less than 2,000 square feet (186 m2) in area on the roof of a building, the second means of egress is permitted to be a fire escape, an alternating tread device, or a:
412.7.3
A water-resistive barrier coating complying with ASTM E2570 requires special inspection where installed over a:
1705.17.1
In an exterior room used for the storage of medical gases, the room must be provided with at least two vents, one of which must be within what maximum distance of the floor?
427.2.1
Test methods and loads for glazed areas in racquetball and squash courts subject to impact loads require impacts to be applied at what height above the playing surface?
2408.2.1
Openings in the fire barrier separating an interior exit stairway or ramp from an exit passageway are prohibited, EXCEPT for the fire door assembly required to provide a means of egress from the interior exit stairway and ramp to the:
1023.3.1
For statically loaded components where load test procedures are not specified, the test load shall be left in place for a period of:
1708.2.2
Where the ground-water table is lowered and maintained at an elevation not less than 6 inches below the bottom of the lowest floor, the floor and walls shall be:
1805.1.3
What is the required fire-resistance rating for electrical circuit protective systems providing power and control signals to occupant evacuation elevators outside the machine room?
3008.8.2
Special inspections for fire-resistant penetrations and joints are required in fire areas containing Group R occupancies with an occupant load greater than:
1705.18
Who must the owner designate to ensure compliance with the site safety plan and enforce its provisions?
3302.2
Where Group R-2 facilities are without elevator service, at least how many stories containing units intended to be occupied as a residence must be provided with an accessible entrance from the exterior, and all units on that story must be Type B units?
1108.7.1.1
Gypsum panel products used in a horizontal diaphragm ceiling must be installed in what orientation relative to the ceiling framing members?
2508.6.2
In lieu of a grade mark on the material, a certificate of inspection is permitted to be accepted for precut, remanufactured, or rough-sawn lumber and for sizes larger than what nominal thickness?
2303.1.1.1
If an enclosed elevator lobby is used to provide hoistway door protection using smoke partitions, what smoke and draft control requirements must the doors comply with?
3006.3
The lift coefficient for concrete and clay tile shall be 0.2 or shall be determined in accordance with SBCCI SSTD 11 or which ASTM standard?
1504.3.1.3
The aggregate floor area of Group H occupancies located in an unlimited area building shall not exceed what maximum percentage of the area of the building?
507.8.1
The construction and utilization of vaults and other enclosed spaces below grade are subject to the terms and conditions of which entity?
3202.1.2
The provisions governing the repair, alteration, change of occupancy, addition to and relocation of existing buildings are found in the:
101.4.7
Emergency lighting shall be arranged to provide initial illumination that is not less than an average of 1 footcandle (11 lux) and a minimum at any point of:
1008.3.2
Structures assigned to Seismic Design Category D, E or F must be designed and detailed in accordance with which standard, except as permitted in ASCE 7, Table 15.4-1?
2202.2.1.2
Special amusement areas having an occupant load of less than 50 shall comply with the requirements for which occupancy group?
411.1
When designing sloped glazing using Equation 24-4, the allowable resistance (Fga) must be based on the:
2404.2
What is the tabular allowable area factor (At) for a Group S-1 occupancy of Type IIA construction that is two or more stories above grade plane and equipped throughout with an automatic sprinkler system (SM)?
Table 506.2
An interior wall or ceiling finish material that is not more than 1/4 inch (6.4 mm) thick must be applied directly onto the wall, ceiling, or structural element without the use of furring strips and shall not be:
803.15.4
According to Table 1404.3(5), for walls without a Class I, II, or III interior vapor retarder in Climate Zone 8, what is the minimum required R-value for continuous insulation on the exterior?
1404.3
Retaining walls are exempt from a building permit requirement, provided the height measured from the bottom of the footing to the top of the wall is not over:
105.2
In Type IV-HT construction, fire-retardant-treated wood framing and sheathing are permitted within exterior wall assemblies with a maximum rating of:
602.4.4.1
Where more than one exit is required, the loss of any one exit or access to one exit shall not reduce the available capacity or width to less than what percentage of the required capacity or width?
1005.5
In a courtroom, a wheelchair space shall be provided within the jury box, but adjacent:
1109.4.1.1
Encroachments into the public right-of-way above grade and below 8 feet (2438 mm) in height are generally prohibited, but which components are specifically required not to open or project into the public right-of-way?
3202.2
What is the maximum number of tiers allowed for a Type IIB open parking garage utilizing ramp access?
Table 406.5.4
Individual unstabilized adobe units are not permitted to have a compressive strength of less than:
2109.2.1.1
What is the Live Load Element Factor required for interior beams?
1607.13.1
The firebox floor of a masonry heater must be a minimum thickness of what minimum thickness of noncombustible material?
2112.3
Portland cement grouts used for ceramic tile installation must comply with which ANSI standard?
2103.2.3.7
Drinking fountains shall not be required for an occupant load of what maximum number?
2902.6
Which ASTM standard applies to adhesives used for fastening gypsum board to wood framing?
Table 2506.2
When a Group S-2 enclosed parking garage (maximum one story above grade plane) is located below a Group S-2 open parking garage, the height and number of tiers of the open parking garage shall be limited as specified in which table?
510.3
Slate shingles shall be secured to the roof with how many fasteners per slate?
1507.7.6
Foam plastic spray applied to a sill plate, joist header, and rim joist in Type V construction is permitted without a thermal barrier provided the maximum thickness does not exceed:
2603.4.1.13
Where HPM gases or liquids are carried in pressurized piping above 15 pounds per square inch gauge (psig), what device must be provided?
415.11.7.3
For natural ventilation purposes in an open parking garage, the area of openings in exterior walls on a tier shall be not less than what percentage of the total perimeter wall area of each tier?
406.5.2
For conditions not addressed by the fenestration manufacturer’s instructions, flashing of fenestration to the wall assembly shall comply with the instructions of the water-resistive barrier manufacturer, the flashing manufacturer, or one of two other approved methods, including:
1404.4.1
If sufficient technical data is submitted to the building official for research and investigation, the costs, reports and investigations required under these provisions must be paid by the owner or the:
1703.4.1
Special inspections and qualification of welding special inspectors for cold-formed steel floor and roof deck must be in accordance with the quality assurance inspection requirements of:
1705.2.3
The maximum allowable area of protected (P) openings in an exterior wall where the fire separation distance is 15 to less than 20 feet is:
Table 705.9
Where fire doors are required to be automatic-closing due to smoke detection, the door shall not have more than what maximum delay before the door starts to close after the smoke detector is actuated?
716.2.6.6
In auditoriums in Group A occupancies that are equipped throughout with an approved automatic sprinkler system, the permissible amount of combustible decorative materials suspended from walls shall not exceed what percentage of the aggregate wall area?
806.2 Exception 1
Where the gradient of stepped aisles is to be the same as the gradient of adjoining seating areas, the riser height shall be not less than 4 inches (102 mm) nor more than:
1030.14.2.2
Handrails are permitted to protrude not more than what distance from the wall or guard into the circulation path?
1003.3.3 Exception
Beam-to-column moment connections in structural steel special moment frames and intermediate moment frames must be prequalified in accordance with AISC 341, Section K1, qualified by testing in accordance with AISC 341, Section K2, or shall be prequalified in accordance with which standard?
2202.2.1.1, 2202.2.1.2
Plastic signs affixed to the storefront of a tenant space facing a mall shall be limited to not more than what percentage of the wall area facing the mall?
402.6.4.1
For soils to be considered expansive, they must have a Plasticity Index (PI) of 15 or greater, and more than what minimum percentage of the soil particles must pass a No. 200 sieve (75 µm)?
1803.5.3 Item 2
What minimum fire protection rating is required for each door in the smoke barrier separating the fire service access elevator lobby from the floor (excluding doors to control rooms)?
3007.6.3
Under what condition are separate toilet facilities not required to be designated by sex?
2902.2 Exception
Urinal partitions shall extend from the wall surface at each side of the urinal not less than 18 inches (457 mm) or to a point not less than what minimum distance beyond the outermost front lip of the urinal?
1210.3.2
What action must an elevator emergency two-way communication system enable authorized personnel to verify?
3001.2
If unidentified reinforcement is approved for use, not less than how many tension tests must be made on representative specimens from each shipment and grade of reinforcing steel proposed for use?
2103.4
For designs outside the scope of Section 2404, who must prepare an analysis or test data for the specific installation?
2404.4
The base course under floors in basements must be not less than 4 inches in thickness and consist of gravel or crushed stone containing not more than what maximum percentage of material that passes through a No. 4 sieve?
1805.4.1
The proportion of lime in cement plaster coats applied to adobe masonry walls shall be not less than:
2109.2.4.8.6
Where shallow foundations will bear on compacted fill material more than 12 inches in depth, the geotechnical investigation must include test methods to be used to determine the maximum dry density and optimum moisture content of the material to be used as:
1803.5.8 Item 3
Doors opening onto a stairway landing shall not reduce the landing to less than what proportion of the required width?
1011.6
A Data Center is used primarily to house information technology equipment (ITE) and serves a total ITE load greater than 10 kW and:
202 [BG] Data Center
For seating at tables, the measurement of required clear width of the aisle or aisle accessway shall be made to a line what distance away from and parallel to the edge of the table or counter?
1030.13.1
According to Table 1705.7, what type of inspection is required to verify element materials, sizes and lengths comply with the requirements for driven deep foundation elements?
Table 1705.7 Item 1
Exterior walls and openings adjacent to an exterior egress balcony must be protected in accordance with Section 705 based on fire separation distance if the fire separation distance is less than:
1021.4
Interior exit stairways and ramps shall have a fire-resistance rating of not less than 2 hours where connecting how many stories or more?
1023.2
For Business occupancies, what is the required ratio for lavatories for the first 80 occupants?
Table 2902.1
A High-Rise Building is defined as a building with an occupied floor or occupiable roof located more than 75 feet (22 860 mm) above the:
202 [BG] High-Rise Building
Mortar for adobe units must be in accordance with Section 2103.2.1, or be composed of adobe soil of the same composition and stabilization as the:
2109.2.4.2.1
The fire service access elevator lobby must be separated from each floor with which type of fire barrier, except that lobby doorways must comply with Section 3007.6.3?
3007.6.2
When using the Simplified Structural Design Procedure, the total linear length of all openings in any individual side wall or end wall designated as part of the lateral force-resisting system shall be limited to not more than what maximum percentage of the length of that side wall or end wall?
3114.8.5.3
Where provided in transportation facilities, variable message signs conveying transportation-related information shall comply with Section 1112.5 and:
1112.5.1
The presumptive load-bearing capacity is permitted to be used where the building official deems the capacity is adequate for the support of lightweight or:
1806.2 Exception
What is the minimum required height for barriers placed on the side of the walkway nearest the construction?
3306.5
The combined thickness of cement plaster coats applied to adobe masonry shall not exceed:
2109.2.4.8.6
Door closers, overhead doorstops, frame stops, power door operators, and electromagnetic door locks shall project into the door opening height not lower than what distance above the floor?
1010.1.1.1 Exception
Rooms containing bathtubs, showers, spas and similar bathing fixtures shall be mechanically ventilated in accordance with:
1202.5.2.1
For floor joists, holes bored in members shall not be within what minimum distance of the top or bottom of the member?
2308.6.1
Where a Type III, IV or V building has a fire separation distance of 30 feet up to 60 feet from property lot lines, what is the required minimum water supply for vertical construction?
3313.3.2
The walls and soffits within enclosed usable spaces under enclosed and unenclosed stairways must be protected by construction having a rating of 1-hour or the fire-resistance rating of the stairway enclosure, whichever is:
1011.7.3
Walls separating dwelling units in the same building in Group R occupancies shall be constructed as:
420.2
What is the maximum allowable building height in feet for a nonsprinklered (NS) building classified as Group I-1 Condition 2 of Type IIIB construction?
Table 504.3
Guards are required at retaining walls located within 36 inches of walking surfaces where the walking surface is located more than what minimum vertical distance to the surface or grade below?
1807.2.5.1
According to Table 1504.8, for an aggregate-surfaced roof using ASTM D1863 (No. 7 or No. 67) aggregate, a mean roof height of 100 ft, and a basic wind speed (V) of 150 mph in Exposure B, what is the minimum required parapet height (in inches)?
1504.8
Special inspection of railing systems composed of structural steel elements is limited to welding inspection of welds at the base of:
1705.2.1 Exception
For conventional light-frame construction, average dead loads shall not exceed what maximum value for combined roof and ceiling, exterior walls, floors and partitions?
2308.2.3
The building official is authorized to grant extensions of time for a permit application abandonment period for additional periods not exceeding:
105.3.2
For Group M and S occupancies, the maximum allowable quantity of low burning velocity Category 1B flammable gas (gaseous) in a sprinklered control area is:
Table 414.2.5.4
Standby or emergency power must be provided in laboratory suites located above the sixth story above grade plane or located in a story below grade plane in accordance with which section of the International Fire Code?
2702.2.13
In standard roll-in-type shower compartments designed for assisted bathing, the clear inside dimension shall be not less than 60 inches (1525 mm) in width and what minimum depth?
1110.2.3.1
For a space in Group A, E, or M occupancies, what is the maximum occupant load allowed for a single exit or exit access doorway?
Table 1006.2.1
A stairway considered part of an accessible means of egress must have a clear width of what minimum distance between handrails?
1009.3.2
Doors or horizontal sliding/vertical security grilles shall not be brought to the closed position when there are 50 or more persons occupying spaces served by:
402.8.8
For buildings of construction types other than Type VB, light-transmitting plastics shall not be installed more than what maximum height above grade level?
2608.2
According to Table 2406.2(2), for glazed panels regulated by Section 2406.4.2 (glazing adjacent to doors) with an exposed surface area of 9 square feet or less, what is the minimum ANSI Z97.1 Category class required?
2406.2
Insulated metal panels (IMP) with a combustible core must be separated from the interior of a building by an approved thermal barrier consisting of 1/2-inch gypsum wallboard or a material complying with the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of:
1409.7.2
For Assembly occupancies (Nightclubs, bars, taverns, dance halls, etc.), what is the required ratio for lavatories?
Table 2902.1
For steel frame structures designed using Load and Resistance Factor Design (LRFD), end connections of all beams and girders must have a minimum nominal axial tensile strength equal to what portion of the required shear strength, but not less than 10 kips?
1616.2.2.2
The means of egress illumination level shall be not less than 1 footcandle (11 lux) at the walking surface. Along exit access stairways, exit stairways, and their required landings, the illumination level shall not be less than:
1008.2.1
Compliance with drainage requirements is not necessary for an exterior wall assembly tested to resist wind-driven rain if the test is conducted in accordance with ASTM E331 at a minimum differential pressure of:
1402.2
The design effects of treatment and redrying on the flexure properties of fire-retardant-treated softwood plywood must be determined in accordance with which ASTM standard?
2303.2.6.1
Foam plastic interior trim shall not constitute more than what maximum percentage of the specific wall or ceiling areas to which it is attached?
2604.2.3
Apartment houses and dormitories where occupants are primarily permanent in nature and containing more than two dwelling units are classified as which Residential Group?
310.3
Glazing not in doors or enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers shall be permitted to be tested in accordance with which standard?
2406.2
For stadiums and arenas with fixed seats, the design shall include horizontal swaying forces of 24 pounds per linear foot of seat applied in which direction?
1607.18.1
Buildings and other structures that represent a low hazard to human life in the event of failure, such as agricultural facilities or minor storage facilities, are assigned to which risk category?
1604.5
In buildings equipped throughout with an automatic sprinkler system, plastic light-diffusing systems shall be protected both above and below unless the system is specifically approved for installation only above the system, or the light-diffusing system is listed and labeled in accordance with which standard?
2606.7.4
Where an automatic sprinkler system is provided, vertical openings for escalators protected by automatic shutters must have a fire-resistance rating of not less than:
712.1.3.2
For special purpose roofs, an underlayment of 5/8-inch Type X water-resistant gypsum backing board or gypsum sheathing shall be placed under minimum nominal 1/2-inch-thick wood structural panel solid sheathing or:
1505.7
According to Table 1611.1, what is the minimum design storm return period required for Risk Category IV buildings?
1611.1
Interlayment for wood shakes shall comply with which ASTM standard?
1507.9.5
According to Table 1507.1.1(1), for Metal roof shingles installed in an area with a maximum basic wind speed (V) of 130 mph (Hurricane-Prone Regions), which underlayment type is required?
1507.1.1
In other than dwelling units, the smooth, hard, nonabsorbent vertical base at the intersection of toilet room floors and walls shall extend upward onto the walls not less than:
1210.2.1
Light-transmitting plastic roof panels shall not be installed in which occupancy groups?
2609.1
For discontinuous mid-aisle handrails in stepped aisles serving seating on both sides, gaps or breaks must be provided at intervals not exceeding how many rows?
1030.16.1
Gutters that are used to secure the perimeter edge of the roof membrane on low-slope built-up, modified bitumen, and single-ply roofs must be tested in accordance with Test Methods G-1 and G-2 of which standard?
1504.6.1
Urinal partitions utilized by the public or employees shall begin at a height not more than 12 inches (305 mm) from the finished floor and extend not less than what minimum height above the finished floor surface?
1210.3.2
In unvented attics in Climate Zones 1, 2, and 3 where only air-permeable insulation is used, a vapor diffusion port shall be installed not more than what distance from the highest point of the roof, measured vertically?
1202.3 Item 5.2.1
Unit masonry walls must be parged on the exterior surface below ground level with not less than what minimum thickness of Portland cement mortar prior to dampproofing material application?
1805.2.2.1
What is the maximum number of seats permitted per row with backrests served by an aisle or doorway at both ends where the assembly seating contains less than 4,000 total seats?
Table 1030.13.2.1
Nonstructural concrete with a freeze-thaw exposure Class F0 must have a minimum specified compressive strength, of not less than:
1904.2
The setback between pools regulated by this code and slopes shall be equal to what fraction of the building footing setback distance required by Section 1808.7?
1808.7.3
As an alternative to surface-burning characteristics testing, reflective plastic core insulation must comply with the acceptance criteria of Section 803.1.1.1 when tested in accordance with NFPA 286 or which other standard?
2614.4
The maximum allowable diaphragm proportions for horizontal gypsum panel product diaphragm ceilings shall be what ratio between shear resisting elements?
2508.6.1
In nonsprinklered buildings, foam plastic is permitted in walk-in coolers or freezer units without a thermal barrier if the foam plastic thickness does not exceed 4 inches, the maximum flame spread index is 75, and the aggregate floor area does not exceed what maximum size?
2603.4.1.3
Copies of necessary test and special inspection records must be filed with the:
1703.6.2
Foundations for buildings and structures founded on expansive soils must be designed in accordance with Section 1808.6.1 or 1808.6.2, UNLESS the building official approves stabilization of the soil in accordance with:
1808.6 Exception 2
A Mezzanine must be in accordance with which section of the code?
202 [BG] Mezzanine
Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads, and such attachment shall not be accomplished by the use of:
1604.8.3
A shaft enclosure connecting four stories or more must have a fire-resistance rating of not less than:
713.4
For unstabilized adobe walls finished with unstabilized clay plaster, what installation component is explicitly stated as not being required?
2109.2.4.8.9.5
Special inspections for wind resistance are required for buildings in wind Exposure Category C or D where basic wind speed, is what minimum speed?
1705.12 Item 2
Where mirrors or mazes disguise the path of egress travel in a special amusement area, low-level exit signs shall be located not more than what distance above the walking surface?
411.4
Glazing facing a swimming pool is considered hazardous if the bottom exposed edge is less than 60 inches (1524 mm) measured vertically above the standing surface, UNLESS the glazing is more than what minimum distance horizontally from the water’s edge?
2406.4.5
Exterior walls required to be of heavy timber construction are permitted to be cross-laminated timber not less than what minimum thickness?
2304.11.2.1
The glass in glass elevator car doors shall be not less than what minimum percentage of the total visible door panel surface area as seen from the car side of the doors?
2409.4.2
In the test procedure for modulus of rupture of adobe units, a vertical load must be applied to the cylinder at the rate of 500 pounds per minute (37 N/s) until:
2109.2.1.2.3
For fire-resistant joint systems protecting joints in smoke barriers, the L rating of the system must not exceed what value per linear foot of joint at 0.30 inch of water (74.7 Pa) for both ambient and elevated temperature tests?
715.9
For the foam plastic spray applied in Type V construction (sill plate, joist header, and rim joist), the density of the foam plastic must be in what range?
2603.4.1.13
Terra cotta and metal cornices must be provided with a structural frame of approved noncombustible material anchored in an:
2104.1.2
If 3/8 inch wood structural panels are used for barriers, what is the maximum stud spacing permitted?
3306.6
Letters on externally illuminated exit signs shall be not less than 6 inches (152 mm) high with the principal strokes of the letters not less than what minimum width?
1013.6.1
As an exception to the hazardous location requirement for windows, a horizontal rail installed 34 to 38 inches (864 to 965 mm) above the walking surface must be not less than what minimum cross-sectional height?
2406.4.3
The F Rating of a through-penetration firestop system or perimeter fire containment system limits the spread of fire through the penetration or void in terms of:
202 [BF] F Rating
The construction documents for structural concrete must include the specified compressive strength of concrete at the stated ages or stages of construction for which each concrete element is designed, and the specified strength or grade of:
1901.5
A roof recover shall NOT be permitted where the existing roof has what maximum number of applications of any type of roof covering?
1512.3 Exception 3
Where panic or fire exit hardware is installed, the actuating portion of the releasing device shall extend not less than what proportion of the door leaf width?
1010.2.8.3
Rectangular chimney flues serving fireplaces with an aspect ratio of 2 to 1 or more shall have a minimum net cross-sectional area of not less than what minimum fraction of the fireplace opening?
2113.16.1
Where security barriers incorporate elements that cannot comply with accessible route requirements, the accessible route shall be permitted to be provided adjacent to security screening devices, allowing persons with disabilities to maintain visual contact with their personal items to the same extent provided:
1104.6 Exception
What is the maximum nominal diameter permitted for penetrating steel, ferrous, or copper pipes where concrete, grout, or mortar is used to protect the annular space in a concrete or masonry wall without requiring a through-penetration firestop system?
714.4.1 Exception
Required preconstruction load tests must be conducted or witnessed by an:
1709.7
Prior to the start of construction, the approved agencies must provide written documentation to the building official demonstrating the competence and relevant experience or training of the:
1704.2.1
Exterior exit stairways shall not be used as an element of a required means of egress for buildings exceeding how many stories above grade plane or that are high-rise buildings?
1027.2
Where provided, fire pump rooms and automatic sprinkler system riser rooms must be designed with sufficient working room to allow inspection, service, repair or replacement without removing:
902.1
The response modification coefficient, R, designated for “Steel systems not specifically detailed for seismic resistance, excluding cantilever column systems” in ASCE 7, Table 12.2-1, shall be permitted for structural steel systems designed and detailed in accordance with which standard?
2202.2.1.1 Exception
Where special inspections or tests are required by Section 1705, the statement of special inspections shall be prepared by the registered design professional in responsible charge, EXCEPT it may be prepared by a qualified person approved by the building official for construction not designed by a:
1704.3 Exception
What is the maximum allowable building height in feet for a nonsprinklered (NS) building classified as Group F, M, S, or U of Type IVB construction?
Table 504.3
Pedestrian walkways connecting balconies in an open mall shall be located not less than what distance from any other pedestrian walkway?
402.4.3.1
Standby power is required for common exhaust systems for domestic kitchens located in multistory structures as required in which section of the International Mechanical Code?
2702.2.5
Awnings, canopies, marquees and signs with less than 15 feet (4572 mm) of clearance above the sidewalk shall not extend into or occupy more than what fraction of the width of the sidewalk measured from the building?
3202.3.1
On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge not less than 12 inches plus:
1808.7.4
For anchor bolts attaching a wood sill plate to concrete, the allowable in-plane shear strength is determined in accordance with ANSI/AWC NDS Table 12E for what type of lateral design value?
1905.7.2 Exception 1.1
An automatic sprinkler system is required throughout all buildings containing a Group S-1 fire area used for the storage of commercial motor vehicles where the fire area exceeds:
903.2.9
Where the path of egress travel is not at the level of exit discharge from an atrium, that portion of the total permitted exit access travel distance that occurs within the atrium shall be not greater than:
1017.3.2.3
The second coat of exterior cement plaster shall not have variations greater than 1/4 inch (6.4 mm) in any direction under what maximum length straight edge?
2512.5
The aggregate area limitations for light-transmitting plastic skylights can be increased by 100 percent if the building is equipped throughout with an automatic sprinkler system or if the building is equipped with what other life safety system?
2610.5 Exception
For buildings of construction types other than Type VB, what is the maximum area of a single pane of light-transmitting plastic glazing permitted to be installed above the first story above grade plane?
2608.2
Where required, an ice barrier shall extend from the lowest edges of all roof surfaces to a point not less than what minimum distance inside the exterior wall line of the building?
1507.1.2
Kitchens shall have a clear passageway of not less than what distance between counter fronts and appliances or counter fronts and walls?
1208.1
Adobe units shall have a moisture content not exceeding what maximum percentage by weight?
2109.2.1.3
In Group I-2 occupancies, failure of a single lamp in a luminaire shall not reduce the illumination level under emergency power to less than:
1008.3.2
Residential Group R-4 occupancy is defined as housing more than five but not more than how many persons, excluding staff, receiving custodial care on a 24-hour basis?
310.5
The minimum slope for lapped, nonsoldered seam metal roof panels without applied lap sealant shall be:
1507.4.2
Unless otherwise indicated, foam plastic insulation must have a flame spread index of not more than 75 and a smoke-developed index of not more than what maximum value when tested in accordance with ASTM E84 or UL 723?
2603.3
For breakaway walls in coastal high hazard areas designed for ultimate load, documentation is required if the resistance is more than what maximum value?
1612.4
Artificial light shall be provided to achieve an average illumination of 10 footcandles (107 lux) over the area of the room at a height of what distance above the floor level?
1204.3
What is the minimum design live load required for the entire structure of covered walkways?
3306.7
For a Solid Masonry Unit, the net cross-sectional area in every plane parallel to the load-bearing surface must be what percentage or more of its gross cross-sectional area?
202 [BS] Solid
What action is the building official authorized to take upon the third offense of failing to properly conduct, document, and maintain documentation required by Section 3302.3?
3302.3.1
Water-resistant gypsum backing board shall not be used in which of the following locations?
2509.3
Service sinks shall not be required to be located in individual tenant spaces in a covered mall provided they are located within what maximum distance of travel of the most remote location in the tenant space?
2902.7
In Seismic Design Category D, E or F, where wood shear wall design values exceed 350 pounds per linear foot, framing members receiving edge fastening from abutting panels must be not less than what minimum assembly?
2306.3(1)
What is the allowable number of stories above grade plane for a nonsprinklered (NS) building classified as Group A-5 of Type IIA construction?
Table 504.4
Concrete masonry units, clay or shale masonry units, stone masonry units, glass unit masonry, and AAC masonry units must comply with Article 2.3 of:
2103.1
The common path of egress travel for a room or space used for assembly purposes having fixed seating shall not exceed what maximum distance from any seat to a point where an occupant has a choice of two paths of egress travel to two exits?
1030.8
According to Table 2103.2.3, what is the composition requirement for the scratchcoat mortar used for ceramic tile walls?
2103.2.3
Water-resistant organic adhesives used for ceramic tile installation must comply with ANSI A136.1, and the shear bond strength after water immersion must be not less than 40 psi (275 kPa) for what adhesive type?
2103.2.3.6
For a cast-in-place deep foundation element, if the unsupported height to least horizontal dimension does not exceed three, it is permitted to design and construct the element as a:
1810.1.3 Exception
The net free area under a masonry or metal rain cap installed on a masonry chimney shall be not less than what minimum multiple of the net free area of the chimney flue outlet it serves?
2113.9.3
Means of egress for the upper occupancy (above an open parking garage) shall be separated from the parking occupancy by fire barriers having not less than a:
510.7.1
Institutional Group I-2 occupancy is characterized by providing medical care on a 24-hour basis for more than how many persons who are incapable of self-preservation?
308.3
Wood tie beams in adobe construction must have a minimum width of not less than:
2109.2.4.7.2
Exterior walls of aircraft hangars located less than 30 feet (9144 mm) from lot lines or a public way shall have a fire-resistance rating of not less than:
412.3.1
For a sprinklered space in Group R-2 occupancy, what is the maximum occupant load allowed for a single exit or exit access doorway?
Table 1006.2.1
The fireplace throat or damper must be located not less than what minimum distance above the top of the fireplace opening?
2111.8
Where a toilet facility is provided for the use of multiple occupants, shall the egress door for the room be lockable from the inside (excluding family or assisted-use toilet facilities)?
2902.3.6
Freestanding parking garages not providing means of egress for buildings or structures assigned to a higher risk category shall be assigned to which risk category?
1604.5 Exception 2
According to Table 1809.7, what is the minimum width and thickness required for a prescriptive concrete footing supporting light-frame construction with three supported floors?
1809.7
For unvented attic assemblies, Section 1202.3 does not apply to enclosures in Climate Zones 5 through 8 that are humidified beyond what maximum percentage during the three coldest months?
1202.3 Exceptions
Glazing adjacent to stairways and ramps is a hazardous location if the bottom exposed edge of the glazing is less than what maximum height above the plane of the adjacent walking surface?
2406.4.6
A museum, library, or place of religious worship is generally classified as which Assembly Group?
303.4
In a safe dispersal area, the area shall be located on the same lot not less than what minimum distance away from the building requiring egress?
1028.5 Exception 2
The continuous vertical bar required beside an opening in a detailed plain concrete structural wall is permitted to substitute for one of the two No. 5 bars required by which section of ACI 318?
1905.5.1
What is the maximum thickness of decorative materials (in inches) that, when applied directly to and adhering tightly to a substrate, are not considered decorative materials?
202 [F] Decorative Materials
Food processing establishments and commercial kitchens not associated with restaurants and similar dining facilities are classified as Group B if they are not more than what area?
304.1
For installations greater than 40 feet above grade plane on Types I, II, III and IV construction, the metal composite material (MCM) system must be tested in accordance with and comply with the acceptance criteria of:
1406.10.3
Accessible units are permitted to be designed and constructed as:
1108.2
Glass in glazed curtain walls, glazed storefronts, and glazed partitions must meet the seismic requirements of which section of ASCE 7?
2404.1
Special inspections and tests shall be required for proposed work that is, in the opinion of the building official, unusual in its nature, such as construction materials and systems that are alternatives to materials and systems prescribed by:
1705.1.1
An anchor building adjoining the perimeter line of an open mall building shall be separated on all sides by a permanent open space of not less than:
402.2
Asphalt shingles shall only be used on roof slopes of what minimum units vertical in 12 units horizontal?
1507.2.2
Where two or more flues are located in the same chimney, masonry wythes shall be built between adjacent flue linings with a minimum thickness of:
2113.14
Group A-1 and A-2 occupancies located in mixed occupancy buildings of unlimited area (Section 507.4) shall have their exit doors discharge to where?
507.4.1
Openings providing access to attic or concealed spaces used for storage of combustible materials shall be protected by assemblies that are self-closing and of solid wood core not less than:
413.2
At least how many companion seats shall be provided for each wheelchair space required by Sections 1109.2.2.1 through 1109.2.2.3?
1109.2.3
The top of a foundation drain must be covered with an:
1805.4.2
What is the Frontage Increase Factor when a building that does not meet Section 507 requirements has 60 percent of its perimeter on an open space of 23 feet?
Table 506.3.3
For a fire separation distance of 5 feet or greater, the minimum distance that an exterior wall projection must be kept from the line used to determine the FSD is:
Table 705.2
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finished floor shall not project horizontally more than what distance into the circulation path?
1003.3.3
Protection of joints and penetrations in fire-resistance-rated assemblies, smoke barriers, and smoke partitions shall not be concealed from view until inspected and:
110.3.8
Miniature golf courses shall be configured so that the accessible holes are consecutive, EXCEPT that one break in the sequence of consecutive holes shall be permitted provided that:
1111.4.12.2 Exception
UL 96A shall not be utilized for buildings used for the production, handling, or storage of ammunition, explosives, flammable liquids, flammable gases, or what other materials?
2703.2
For an automatic or power-operated revolving door with a maximum nominal diameter of 12 feet, what is the maximum allowable revolving door speed in RPM?
Table 1010.3.1(1)
According to Table 1808.8.1, what is the minimum specified compressive strength (*f’*c) required for foundations for structures assigned to Seismic Design Category D, E or F, other than Group R or U of light-frame construction two stories or less?
1808.8.1
Compacted fill material 12 inches or less in depth is exempted from complying with an approved geotechnical report, provided that the in-place dry density is not less than 90 percent of the maximum dry density at optimum moisture content determined in accordance with:
1804.6 Exception
From a height of 36 inches (914 mm) to 42 inches (1067 mm), guards shall not have openings that allow passage of a sphere of what maximum diameter?
1015.4 Exception 1
What is the required protection type for pedestrians when the height of construction is more than 8 feet and the distance from construction to the lot line is less than 5 feet?
Table 3306.1
For pivoted or side-hinged doors not required to have a fire protection rating, the foam plastic insulation core must have a flame spread index of 75 or less, a smoke-developed index of 450 or less, and the door facing must be of steel having a minimum base metal thickness of:
2603.4.1.7
In cold storage buildings equipped throughout with an automatic sprinkler system, foam plastic insulation up to 10 inches thick is permitted, provided that when tested in a thickness of 4 inches (102 mm), it has a maximum flame spread index of 75 and a maximum smoke-developed index of 450. The sprinkler system must be provided in both the room and what other area of the building?
2603.3 Exception
Handrails with a circular cross section shall have an outside diameter of not less than 1 1/4 inches (32 mm) and not greater than:
1014.4.1
Where interior glazing is installed adjacent to a walking surface, the differential deflection of two adjacent unsupported edges shall be not greater than the thickness of the panels when a force of 50 plf (730 N/m) is applied horizontally at any point up to:
2403.4
In Group R-2 dormitories, within sleeping units and dwelling units that are equipped throughout with an automatic sprinkler system, the permissible amount of combustible decorative materials suspended from walls shall not exceed what percentage of the aggregate wall areas?
806.2 Exception 2
In cold-formed steel light-frame construction assigned to Seismic Design Category D, E or F, the seismic force-resisting system must be designed and detailed in accordance with which standard?
2206.1.1.2
Extruded Polystyrene (XPS) used as foam plastic insulating sheathing must comply with which ASTM standard?
Table 2603.1.2
Which criterion must be met for an existing structure to continue its legal occupancy after the adoption date of this code?
202 [A] Approved
The enclosed fire service access elevator lobby must have direct access to which other means of egress component?
3007.6.1
In a 0.5-hour fire partition, what is the minimum required fire window assembly rating in hours?
Table 716.1(3)
For Group R and U occupancies, the required 1-hour fire-resistance-rated exterior walls terminating at the underside of the roof must ensure that parallel roof/ceiling framing is not less than 1-hour rated for a width of:
705.12 Exception 4.1
Public toilet facilities are not required for structures and tenant spaces intended for quick transactions (takeout, pickup, drop-off), provided the public access area is less than or equal to what maximum size?
2902.3 Exception
What is the Live Load Element Factor required for interior columns?
1607.13.1
According to Table 1507.13.3, which material standard applies to Silicone protective coating used for sprayed polyurethane foam roofing?
1507.13.3
Where required by Section 2304.12, plastic composite materials containing wood, cellulosic, or other biodegradable materials must be termite and decay resistant as determined in accordance with which standard?
2612.4
A Level 2 Aerosol Product has a total chemical heat of combustion greater than 8,600 Btu/lb (20 kJ/g) but less than or equal to:
202 [F] Level 2 Aerosol Products
Where two or more toilet facilities are provided for each sex, how must the required number of lavatories be distributed?
2902.1.3
Area wells with a vertical depth of more than 44 inches (1118 mm) shall be equipped with an approved permanently affixed ladder or steps. The ladders or rungs shall be spaced not more than what distance on center (o.c.) vertically for the full height of the area well?
1031.5.2.1
Ramps with a rise greater than what distance shall have handrails on both sides?
1012.8
The breakout force of a revolving door not used as a component of a means of egress shall not be more than what maximum weight?
1010.3.1.2
Fire protection of structural members in roof construction shall NOT be required (even if Table 601 specifies a rating) where every part of the roof construction is 20 feet or more above any floor or mezzanine immediately below, EXCEPT in which occupancy groups?
Table 601, Footnote c
Walls less than what maximum length constructed of adobe units are considered isolated piers or columns and cannot be used in a load-bearing capacity?
2109.2.4.7
Where a metal-plate-connected wood truss clear span is 60 feet or greater, the special inspector must verify that the temporary installation restraint/bracing and the permanent individual truss member restraint/bracing are installed in accordance with the:
1705.5.2
A partition live load is not required where the minimum specified live load is equal to or greater than:
1607.5 Exception
A cricket or saddle shall be installed on the ridge side of any chimney or penetration greater than what maximum width as measured perpendicular to the slope?
1503.5
Penthouses shall not be used for purposes other than the shelter of mechanical or electrical equipment, tanks, elevators and related machinery, stairways or:
1511.2.2
For glass sloped 30 degrees (0.52 rad) or less from horizontal, the glass dead load (D) in psf is calculated as:
2404.2
Where required for aggregate-surfaced roofs, the minimum parapet height shall be determined based on each roof surface elevation, and at no point shall the parapet height be less than that required by:
1504.8
In concrete frame structures, the reinforcing steel passing through the longitudinal column reinforcement shall have a minimum nominal tensile strength equal to two-thirds of the required one-way vertical strength of the connection of the floor or roof system to the column in each direction, unless the slabs have continuous reinforcement having an area not less than what factor multiplied by the concrete area?
1616.2.1 Exception
What type of room/space containing the operation or motion controller for elevator operation must be provided with an independent ventilation or air-conditioning system?
3005.2
It shall be the duty of the owner or the owner’s authorized agent to cause the work to remain visible and able to be accessed for inspection purposes until:
110.1
A care facility that provides accommodations for five or fewer persons receiving care is classified as which Residential Group?
310.4
Reports of mill tests are required for reinforcing bars complying with ASTM A615 and used to resist earthquake-induced forces in seismic force-resisting systems in structures assigned to which Seismic Design Categories?
1704.5 Item 7
For exit access stairways and ramps in sprinklered buildings (Groups R-1, R-2, R-3) where the opening is protected by a draft curtain and closely spaced sprinklers, this provision is limited to openings that do not connect more than how many stories?
1019.3 Item 4
At least what percentage of holes on miniature golf courses shall be accessible?
1111.4.12.1
Type III construction is defined as having exterior walls of noncombustible materials and interior building elements made of:
602.3
In employee and public toilet rooms, where must the required lavatory be located relative to the required water closet?
2903.1.2
Chimneys for high-heat appliances must be constructed with double walls of solid masonry units or concrete, each wall to be not less than 8 inches (203 mm) thick with a minimum airspace between the walls of:
2113.11.3.1
According to Table 1705.3, what type of special inspection is required to verify the use of required concrete design mix?
Table 1705.3 Item 5
Openings in a spark arrestor screen shall not permit the passage of spheres having a diameter greater than 1/2 inch (12.7 mm) nor block the passage of spheres having a diameter less than:
2113.9.2 Item 3
Door handles, pulls, latches, locks and other operating devices shall be installed 34 inches (864 mm) minimum and what maximum distance above the finished floor?
1010.2.3
A minimum clearance of 4 inches (102 mm) must be provided between the exterior surfaces of a concrete or masonry chimney for medium-heat appliances and what other material?
2113.11.2.5
Flat or corrugated light-transmitting plastic skylights must slope not less than what minimum slope?
2610.3
Anchorage of roof to walls and columns, and of walls and columns to foundations, shall be provided to resist the uplift and sliding forces that result from the application of the:
1604.8.1
Covered or open mall buildings shall not exceed three floor levels at any point nor more than how many stories above grade plane?
402.1
What is the Tabular allowable area factor in square feet for a nonsprinklered (NS) building classified as Group B of Type IIIB construction?
Table 506.2
An approved agency must employ experienced personnel educated in conducting, supervising and evaluating tests and:
1703.1.3
Where water closet compartments and urinals provided in a toilet room or bathing room totals six or more, at least what percentage of the total number of compartments shall be ambulatory accessible?
1110.2.4
What is the maximum exit access travel distance permitted from a first story above grade plane with a Group B occupancy (other than R-2) served by a single exit?
Table 1006.3.3
The 1/4-inch (6.4 mm) ties or equivalent reinforcement for vertical bars in masonry fireplaces must be spaced not to exceed what maximum distance on center in concrete?
2111.4.2
For every six or fraction of six accessible parking spaces, at least how many shall be a van-accessible parking space?
1106.6
Standby power for emergency voice/alarm communication systems must be provided in accordance with which NFPA standard?
2702.2.4
What is the required separation and protection for a laundry room over 100 square feet that is located within a Group E occupancy?
Table 509.1
The storage of gypsum board, electrical motors, and foods in noncombustible containers is classified as which Storage Group?
311.3
What is the maximum permitted area in square feet for each opening through a fire wall?
706.8
Where mid-aisle handrails are provided in stepped aisles, there shall be an additional rail located approximately what distance below the handrail?
1030.16.4
The interior finish of walls and ceilings of the atrium shall be not less than:
404.8
The thickness of thin exterior structural glass veneer must be not less than:
1404.13.2
Emergency ventilation shall be provided for stages larger than 1,000 square feet (93 m2) in floor area, or with a stage height greater than:
410.2.7
According to Table 2607.4, for a fire separation distance of over 30 feet, what is the minimum vertical separation required between CC2 light-transmitting plastic wall panels?
Table 2607.4
Private garages or carports that contain required accessible parking are required to comply with Chapter 11, even though they are classified as which occupancy type?
1103.2.4
Masonry chimneys shall not be corbeled more than what maximum fraction of the chimney’s wall thickness from a wall or foundation?
2113.5
Experience or training of special inspectors is considered relevant where the documented experience or training is related in complexity to the same type of special inspection or testing activities for projects of:
1704.2.1
A bonding agent approved by the SFRM manufacturer must be applied to a primed, painted or encapsulated surface where the bond strengths are found to be:
1705.15.6.3
In-situ load tests shall be conducted in accordance with Section 1708.2.1 or 1708.2.2 and shall be supervised by a:
1708.2
Ballasted, unattached PV panel systems shall be designed and installed only on roofs with slopes not more than:
1613.4
Vehicle ramps used for vertical circulation as well as parking shall not exceed a slope of:
406.4.3
Walls or portions thereof that retain earth and enclose interior spaces and floors below grade must be waterproofed and dampproofed, with the exception of those spaces containing groups other than residential and institutional where such omission is not detrimental to the building or:
1805.1
For a sprinklered space in Group H-4 or H-5 occupancy, what is the maximum common path of egress travel distance permitted in feet?
Table 1006.2.1
What is the minimum required length of a court unless bounded on one end by a public way or yard?
1205.3
Exterior windows and sliding doors must be tested and labeled as conforming to which standard?
1709.5.1
According to Table 2109.2.3.1, what is the allowable shear load (pounds) for a 3/4-inch-diameter bolt embedded 15 inches in adobe masonry?
2109.2.3.1
What is the required separation in hours between a sprinklered (S) Group H-5 occupancy and a sprinklered (S) Group F-1 occupancy?
Table 508.4
An automatic sprinkler system is required throughout a Group F-1 fire area used for the manufacture of upholstered furniture or mattresses that exceeds:
903.2.4.3
For structures assigned to Seismic Design Category C, D, E or F, the ends of hoops, spirals and ties used in concrete deep foundation elements must be terminated with seismic hooks and shall be turned into the:
1810.3.2.1.1
Guards are required along open-sided walking surfaces that are located more than what distance measured vertically to the floor or grade below?
1015.2
According to Table 1507.3.7 for Interlocking Clay or Concrete Roof Tile (with anchor lugs, solid sheathing without battens) on all roof slopes, what is the attachment requirement for a maximum Allowable Stress Design Wind Speed (Vasd) of 85 mph and a mean roof height of 0–60 feet?
1507.3.7
A building intended for unlimited area use (Section 507) has 65 percent of its perimeter fronting on an open space of 55 feet or greater. What is the allowable Frontage Increase Factor?
Table 506.3.3.1
For prescriptive concrete foundation walls, vertical reinforcement with a minimum yield strength of 40,000 psi is permitted, provided that the same size bar is used and the spacing shown in Table 1807.1.6.2 is reduced by multiplying the spacing by:
1807.1.6.2 Item 2
What is the maximum slope considered to be a Low-Slope roof?
202 [BS] Low-Slope
For horizontal vinyl siding installed on cold-formed steel light-frame construction, screw fasteners shall penetrate through the steel with not fewer than:
1404.15.1.2
Automatic sprinkler system riser rooms and fire pump rooms must be maintained at a temperature of not less than:
902.1.3
Wood veneers on exterior walls of Types I, II, III and IV construction shall not exceed 40 feet in height above grade, unless fire-retardant-treated wood is used, in which case the height shall not exceed:
1404.6
Which occupancy group is exempt from the requirement for space heating systems?
1203.1 Exceptions
What is the required fire-resistance rating for enclosures of machine rooms, control rooms, control spaces, and machinery spaces outside of the hoistway enclosure?
3005.4
Turnstiles serving an occupant load greater than 300 that are not portable shall have a side-hinged swinging door that conforms to Section 1010.1 within what maximum distance?
1010.5.4
For anchor bolts attaching a wood sill plate to concrete, anchor bolts must be embedded into concrete not less than:
1905.7.2 Exception 1.3
The design, testing, and utilization of industrial steel work platforms must be in accordance with which standard?
2212.1
An open side of an exterior exit stairway must have not less than what minimum aggregate open area adjacent to each floor level and intermediate landing?
1027.3
The line established by law, beyond which a building shall not extend, except as specifically provided by law, is the:
202 [BG] Building Line
Asphalt shingles shall have the minimum number of fasteners required by the manufacturer, but not less than how many fasteners per strip shingle?
1507.2.6
The aggregate area of penthouses and other enclosed rooftop structures shall not exceed what fraction of the area of the supporting roof deck?
1511.1.1
Site safety plans must include the name and contact information for which role?
3302.1.1
Structural concrete reinforced with Glass Fiber Reinforced Polymer (GFRP) reinforcement is permitted only where fire-resistance ratings are:
1901.2.1
For noncombustible membranes used as a roof or skylight of any building, what is the minimum height required above any floor, balcony, or gallery?
3102.6.1
Where a cold-formed steel truss clear span is 60 feet or greater, the special inspector must verify that the temporary installation restraint/bracing and permanent individual truss member restraint/bracing are installed in accordance with the:
1705.2.5
In Group R-2 apartment houses containing more than 20 dwelling units or sleeping units, at least what percentage but not less than one of the units shall be a Type A unit?
1108.6.2.2.1
An exterior wall on a building of Type I, II, III or IV construction, greater than 40 feet in height above grade plane, containing a combustible water-resistive barrier must be tested in accordance with and comply with the acceptance criteria of:
1402.6
Factory industrial uses that are not classified as F-2 Low Hazard, such as the manufacturing of furniture or appliances, shall be classified as which group?
306.2
The common path of egress travel shall not exceed 30 feet (9144 mm) from any point in a Group M merchandise pad, EXCEPT for areas serving not more than 50 occupants, where it shall not exceed:
1018.4 Exception
Operable parts that are intended for use only by service or maintenance personnel are:
1110.18 Exception 1
For masonry foundation walls, alternative reinforcing bar sizes are permitted, provided the spacing of reinforcement does not exceed:
1807.1.6.3.1
What is the minimum required fire-resistance rating for an exterior wall of a nonsprinklered Group A, B, E, F-2, I, R, S-2, or U occupancy where the fire separation distance is 10 feet or greater and less than 30 feet, and the construction type is IA, IB, IVA, or IVB?
Table 705.5 Note c
For high-rise buildings not greater than 420 feet (128 m) in height, the fire-resistance rating of columns supporting floors in Type IA construction shall be reduced to:
403.2.1.1 Exception
Prior to commencement of vertical construction of Type III, IV or V buildings utilizing combustible materials, and having a fire separation distance less than 30 feet from property lot lines, what is the required minimum water supply?
3313.3.1
For plain concrete footings supporting walls in Seismic Design Category C, D, E or F, the reinforcing bars must have a total area of not less than what factor multiplied by the gross cross-sectional area of the footing?
1905.6.2 Item 3
A masonry heater must be designed to route exhaust gases through internal heat exchange channels where the flow path downstream of the firebox includes flow in either a horizontal or downward direction before entering the:
2112.1
Anchored slab-type veneer units shall not exceed 2 inches in thickness, 48 inches in length or height, or what maximum area?
1404.9
Each light-transmitting plastic skylight must have a maximum area within the curb of:
2610.4
Where uplift is due to wind or seismic loading, the minimum factor of safety is permitted to be reduced to one and one-half where capacity is determined by:
1810.3.3.1.5 Exception
Curtains, draperies, fabric hangings and similar combustible decorative materials suspended from walls or ceilings in Group A, B, E, I, M, R-1 and R-2 dormitories shall not exceed what maximum percentage of the specific wall or ceiling area?
806.2
Surface-bonding mortar for concrete masonry units shall comply with which ASTM standard?
2103.2.2
Foundations placed below the active zone of expansive soil shall be designed to prevent uplift of the supported structure, and foundations penetrating expansive soils shall be designed to resist forces exerted on the foundation due to:
1808.6.1 Item 2
For structures assigned to Seismic Design Category D, E or F, the construction documents must include a statement if which element is designed as a structural diaphragm?
1901.5
Fasteners for horizontal gypsum panel product diaphragm ceilings must be spaced not more than what maximum distance on center at all supports, including perimeter blocking?
2508.6.4
According to Table 1404.2, what is the minimum nominal thickness required for marble slabs?
1404.2
According to Table 1610.1, what is the design lateral soil load for at-rest pressure (psf per foot of depth) for Inorganic clays of low to medium plasticity (CL)?
1610.1
Information required to be permanently identified on the product, material or assembly must be of a type that, once applied, cannot be removed without being:
1703.5.4
In Group I-2 occupancies, any change in elevation in portions of the means of egress that serve nonambulatory persons shall be by means of a ramp or sloped walkway, throughout which area?
1003.5
An accessory room or space used for assembly purposes that is less than 750 square feet (70 m2) in area shall be classified as a Group B occupancy or:
303.1.2
Light-transmitting plastics classified as Class CC1 must have a burning extent of what maximum distance when tested in accordance with ASTM D635?
2606.4
In buildings four or more stories above grade plane, one stairway shall extend to the roof surface unless the roof has a slope steeper than:
1011.12
Where an interior exit stairway or ramp is extended by an exit passageway, the fire barrier separating the two components must have a fire-resistance rating not less than that required for the:
1023.3.1
What special feature must be installed in each fire door assembly in the smoke barrier of an occupant evacuation elevator lobby?
3008.6.3.1
Swimming pools, wading pools, cold baths, hot tubs and spas shall be accessible and be on an accessible route, EXCEPT that where spas, cold baths or hot tubs are clustered at a single location, at least 5 percent, but not less than one of each type in each cluster, shall be:
1111.4.14 Exception 2
Approval of a fabricator to perform work without special inspection must be based on review of the fabricator’s written fabrication procedures and quality control manuals, with periodic auditing by an approved agency or the:
1704.2.5.1
A spiral stairway used for egress must have a minimum clear tread depth of 6 3/4 inches (171 mm) at a point 12 inches (305 mm) from the narrow edge, and the maximum riser height shall be:
1011.1
In structures assigned to Seismic Design Category A or B, what is the seismic reinforcement requirement for masonry chimneys?
2113.3
Balconies on upper levels of an open mall shall not project into the required open space width of not less than:
402.4.3
In Group R-1 occupancies, where 350 total dwelling units or sleeping units are provided, what is the minimum required number of Accessible units with roll-in showers?
Table 1108.6.1.1
According to Table 1404.3(3), in Climate Zone 5, what is the minimum R-value of continuous insulation required over a 2×4 wall to permit the use of a Class III vapor retarder?
1404.3
What is the minimum required horizontal separation between a play structure and building walls, partitions, or elements of the means of egress?
424.4
In Group I-2 occupancies, a timer shall be provided that automatically deactivates domestic cooking appliances within a period of not more than:
407.2.7
Dome-shaped light-transmitting plastic skylights must rise above the mounting flange a minimum distance equal to 10 percent of the maximum width of the dome but not less than:
2610.3
Special inspections and tests for glass unit masonry or masonry veneer in a structure classified as Risk Category IV shall be performed in accordance with:
1705.4.1
If a greenhouse is not classified as another occupancy (such as Group A-3 or Group M), how shall it be classified?
312.1.1
When must demolition construction documents and a schedule be submitted?
3303.1
If a room contains both a mezzanine and an equipment platform, the aggregate area of the two raised floor levels shall be not greater than what fraction of the floor area of the room?
505.2.1.1
In Types III and V construction, what material is permitted for use as hangers and assembly members of dropped ceilings that are below a horizontal fire-resistance-rated floor or roof assembly?
803.15.2.1 Exception
What information must be continuously displayed at the fire command center (or approved alternate location) for occupant evacuation elevators?
3008.7
A building, room or space used for assembly purposes with fixed seating with a seating capacity of 51 to 100 requires what minimum number of wheelchair spaces?
Table 1109.2.2.1
For aggregate-surfaced roofs in Exposure D, the required parapet height shall be determined by adding what minimum distance (in inches) to the parapet height required for Exposure C?
1504.8
On buildings of Types I, II, III and IV-HT construction, combustible exterior wall coverings shall not exceed 10 percent of an exterior wall surface area where the fire separation distance is:
1405.1.1
What is the minimum critical radiant flux classification required for interior floor finish materials in corridors in a Group I-2 occupancy?
804.4.2
The roof structure supporting a raised-deck system must be designed to support any standing water resulting from the installation of the raised-deck system, as required by Section 1502 and the:
1511.9.5
Where cladding is installed directly over foam sheathing to wood framing using a 0.131-inch diameter nail, with a cladding weight of 18 psf and a fastener vertical spacing of 6 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.3.1 (assuming 16 inches on center horizontal spacing)?
1404.5.3.1
According to Table 1404.3(1), vapor retarder paint applied to yield a perm rating greater than 1.0 and less than or equal to 10 is considered which class of vapor retarder?
1404.3
Coordination of terminology used in ACI 318 and ASCE 7 must be in accordance with which section?
1902.1
Glazing in an individual fixed or operable panel is considered a hazardous location (Section 2406.4.3) if the bottom edge is less than 18 inches (457 mm) above the floor and the top edge is greater than:
2406.4.3
For structures assigned to Seismic Design Category B or C, if a response modification coefficient, R, in accordance with ASCE 7, Table 12.2-1, is used, the structures must be designed and detailed in accordance with the requirements of which standard?
2202.2.1.1
Stationary emergency and standby power systems generators required by this code shall be listed in accordance with which UL standard?
2702.1.1
The minimum ambient and substrate temperature to be maintained during and for not fewer than 24 hours after the application of SFRM is:
704.12.4
The formula for determining the depth of embedment required to resist lateral loads for nonconstrained embedded posts is subject to a maximum embedment depth for the purpose of computing lateral pressure of:
1807.3.2.1
Fiber-cement lap siding having a maximum width of 12 inches must be lapped not less than:
1404.17.2
Doors in smoke partitions that are required to meet the requirements for a smoke and draft control door assembly must have an air leakage rate not exceeding what value at 0.10 inch of water (25 Pa) for both the ambient and elevated temperature tests?
710.5.2.2
Where structural steel members require fire protection, any additional structural steel members having direct connection to the primary structural frame shall be protected with the same fire-resistive material and thickness for a distance of not less than:
704.5.1
A permit issued shall become invalid if the work authorized on the site is suspended or abandoned for a period of how many days after the time the work is commenced?
105.5
Liquid storage rooms and rooms for flammable or combustible liquid use in closed systems having a floor area of not more than what size need NOT be located on the outer perimeter of an unlimited area building?
507.8.1.1.2
A Class I standpipe hose connection must be provided in the interior exit stairway and ramp having direct access from where?
3007.9
For passenger vehicle garages accommodating not more than nine passengers, the concentrated load of 3,000 pounds shall act on an area of:
1607.7
According to Table 1705.3, what inspection is required prior to concrete placement?
Table 1705.3 Item 6
The area of a Group F-2 or S-2 building of any construction type not more than one story above grade plane shall not be limited if surrounded by public ways or yards not less than what width?
507.3
Exterior Insulation and Finish Systems (EIFS) with drainage must have an average minimum drainage efficiency of what minimum percentage when tested in accordance with the requirements of ASTM E2273?
1407.4.1
In Type IV-A construction, the floor assembly must contain a noncombustible material above the mass timber not less than what thickness?
602.4.1.3
For sloped wired glass designed using Equation 24-4, the total load (Fg) must be less than what multiple of the nonfactored load (Fge)?
2404.3.2
For buildings of construction types other than Type VB, the aggregate area of light-transmitting plastic glazing shall not exceed what maximum percentage of the area of any wall face of the story in which it is installed?
2608.2
When firefighters’ emergency operation is active, what is the minimum required illumination level for the entire height of the fire service access elevator hoistway?
3007.5.2
A thermal barrier is not required for a high-pressure decorative exterior-grade compact laminate (HPL) system where the system is specifically approved based on tests conducted in accordance with NFPA 286, UL 1040 or:
1408.10.3
An Alternating Tread Device has a series of steps between 50 and 70 degrees from horizontal, which corresponds to what range in radians?
202 [BE] Alternating Tread Device
Thresholds at doorways shall not exceed 1/2 inch (12.7 mm) in height above the finished floor or landing for non-sliding doors, or what maximum height for sliding doors serving dwelling units?
1010.1.6
In separated occupancies, the required separation between Group A, E (sprinklered) and Group H-2 (sprinklered) is:
Table 508.4
Special inspections are not required for cold-formed steel light-frame shear walls where the sheathing is wood structural panel on only one side and the specified fastener spacing at the sheet edges is more than what maximum distance on center?
1705.12.2 Exception 2
Which standard governs the design, construction, installation, alteration, repair, and maintenance of elevators, escalators, dumbwaiters, moving walks, and material lifts?
Table 3001.3
Glazed openings in doors are not considered hazardous locations if the opening size is unable to pass a sphere of what diameter?
2406.4.1
Walls and partitions within 2 feet (610 mm) of service sinks, urinals and water closets must have a smooth, hard, nonabsorbent surface to a height of not less than what minimum distance above the floor?
1210.2.2
In an accessible toilet room, where a floor level is not required to be connected by an accessible route, the only toilet rooms or bathing rooms provided within the facility shall not be located:
1110.2
The underground portion of an underground building shall be of which type of construction?
405.2
If a multiple occupant toilet room egress door is permitted to be lockable from inside by authorized personnel, the door must also be capable of being unlocked from outside with a key or what other means?
2902.3.6 Exception
The route to the required public toilet facilities shall not pass through which three specific types of rooms?
2902.3.1
If an alternative material, design, or method of construction is not approved by the building official, how must the building official respond?
104.2.3.2
Buildings containing materials that pose a detonation hazard, such as Class 4 oxidizers or Division 1.1 explosives, shall be classified as which High-Hazard Group?
307.3
For insulated metal panel (IMP) systems with a combustible core insulation of 4 inches or less in thickness, the core must have a flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in accordance with:
1409.7.1
What is the required interior wall and ceiling finish classification for interior exit stairways and ramps in a nonsprinklered Group R-2 occupancy?
Table 803.13
Where pay toilet facilities are installed, must they be counted toward the required minimum toilet facilities?
2902.3.5
In a self-service storage facility with 10 total spaces, what is the minimum number of required accessible self-storage spaces?
Table 1109.3
To determine the occupant load of each sex, the total occupant load shall be divided in half, but an exception applies where approved statistical data indicates a distribution of the sexes of other than what specific percentage of each sex?
2902.1.1 Exception
Where required, waterproofing for concrete floors shall be accomplished by placing a membrane of rubberized asphalt, butyl rubber, fully adhered/fully bonded HDPE or polyolefin composite membrane or not less than 6-mil polyvinyl chloride with joints lapped not less than:
1805.3.1
The suitability of clay subsoil for use in clay plaster must be determined in accordance with the Figure 2 Ribbon Test and the Figure 3 Ball Test in the appendix of which ASTM standard?
2109.2.4.8.9.2
When can elements of an excavation retention system be removed or decommissioned?
3307.2.2
Incidental uses shall not occupy more than what percentage of the building area of the story in which they are located?
509.3
What is the maximum allowable building height in feet for a sprinklered (S) building classified as Group A, B, E, F, M, S, or U of Type VB construction?
Table 504.3
In ambulatory care facilities requiring smoke compartmentation, the area of any one smoke compartment shall be not greater than:
422.3
Solid or hollow approved glass block shall not be used in fire walls, party walls, fire barriers, fire partitions, smoke barriers, or for:
2110.1.1
For ambulatory care facilities, an automatic sprinkler system is required throughout the entire floor where four or more care recipients are:
903.2.2.1
An accessible children’s water closet is permitted to be set not closer than what minimum distance from its center to the required partition or to the wall on one side?
2903.1.1 Exception
Fire apparatus access roads required by the International Fire Code must be maintained clear of obstructions that reduce the width of the usable roadway to less than what minimum width?
3302.3
What material must fully encase the backs of wall-mounted signs and non-illuminated portions of all interior signs regulated by Section 2611?
2611.4
Structural elements that support hoists for façade access and building maintenance equipment shall be designed for a live load of 2.5 times the rated load of the hoist or the:
1607.12.3
For a building containing accessory occupancies, the allowable building height and number of stories shall be based on the limitations for which occupancy?
508.2.2
What is the minimum vertical clearance required from the public right-of-way to the lowest part of a pedestrian walkway?
3202.3.4
For cold-formed steel light-frame construction seismic force-resisting systems in Seismic Design Category C, D, E or F, periodic special inspection is required for welding operations and:
1705.13.3
For shakes and taper sawn shakes of naturally durable wood, the spacing between shakes in the same course shall be what maximum distance?
1507.9.8
At what vertical distance above the finished floor must the fire service access elevator symbol be installed?
3007.6.5
Where provided, saunas and steam rooms are required to be accessible, EXCEPT where they are clustered at a single location, at least what percentage, but not less than one, of each type in each cluster shall be accessible?
1110.9 Exception
For driven deep foundation elements where allowable loads exceed 40 tons, the wave equation method of analysis must be used, and the allowable loads must be verified by load tests in accordance with:
1810.3.3.1.1
At least what percentage, but not less than one, of care recipient and visitor parking spaces provided to serve hospital outpatient facilities shall be accessible?
1106.4
What is the maximum horizontal area permitted between draftstops in combustible attic spaces in occupancies other than Group R?
718.4
What is the maximum number of years required for the building official to retain official records, unless otherwise provided by other regulations?
104.7
Fire-retardant-treated wood tested in accordance with ASTM E84 or UL 723 must have a listed flame spread index of 25 or less, and the flame front shall not progress more than what maximum distance beyond the centerline of the burners during the additional 20-minute test period?
2303.2
One-story detached accessory structures used as tool and storage sheds are exempt from a building permit provided the floor area is not greater than:
105.2
Stair riser heights shall be 7 inches (178 mm) maximum and what minimum height?
1011.5.2
The fire-resistance rating of primary structural frame and bearing walls is permitted to be reduced by 1 hour where supporting only a:
Table 601, Footnote a
What are the five acceptable methods for providing required elevator hoistway door protection?
3006.3
No. 15 asphalt felt and water-resistive barriers complying with ASTM E2556 shall be applied horizontally with the upper layer lapped over the lower layer not less than:
1403.2
For skylights rated for separate performance grades (PG_Pos and PG_Neg), if 0.6 times the outward wind force (Wo) is less than the dead weight of the glazing (D), what is the maximum required outward design load (Fgo) (Equation 24-15)?
2405.5.2
What is the maximum allowable quantity (in gallons) for storage of Corrosive liquids per control area in Group M and S occupancies, where the building is equipped with an automatic sprinkler system? (Use Note b)
Table 414.2.5.1 Note b
The maximum allowable quantity for storage of Cryogenic Flammable (liquid) per control area is:
Table 307.1(1)
An attached top rail is not required for guards with structural glass balusters if the baluster panels are laminated glass meeting certain conditions and tested to remain in place as a barrier following impact or glass breakage in accordance with which ASTM standard?
2407.1.2
Where reinstallation of materials is permitted, which existing components shall NOT be reinstalled where rusted, damaged or deteriorated?
1512.4
According to Table 1705.2.6, what type of special inspection is required for the installation of rafter/beam flange braces and column flange braces in metal building systems?
Table 1705.2.6 Item 1
Adjacent combustible members entering into a concrete or masonry fire wall from opposite sides must have a distance between embedded ends of not less than:
706.7
For Hospital (Visitor facilities), what is the required ratio for water closets per care recipient sleeping units or treatment room?
Table 2902.1
Where a lining is not provided in a masonry firebox, the total minimum thickness of back and sidewalls shall be:
2111.6
Elements or structures enclosing occupiable roof areas shall not extend more than what maximum distance above the surface of the occupiable roof?
503.1.4.1
Soil classification for geotechnical investigations must be based on observation and any necessary tests of materials disclosed by borings, test pits, or other subsurface exploration, and rock must be classified in accordance with which ASTM standard?
1803.3
What is the maximum encroachment permitted for vestibules and storm enclosures?
3202.4
Handrails and guards shall be designed to resist a concentrated load of not less than:
1607.9.1
Detectable warnings are required on passenger transit platform edges bordering a drop-off and not protected by platform screens or guards, EXCEPT that they are not required at:
1110.13 Exception
In occupancies other than covered and open mall buildings, the path of travel to required public and employee toilet facilities shall not exceed what maximum distance?
2902.3.3
Expansion joints not less than 1/4 inch wide shall be provided where thin exterior structural glass veneer abuts nonresilient material at sides or top, and horizontal joints shall be held to not less than what minimum distance by an approved nonrigid substance or device?
1404.13.5
For structures assigned to Seismic Design Category C, D, E or F, the special inspector must examine designated seismic systems requiring seismic qualification and verify that the label, anchorage and mounting conform to the:
1705.13.4
A flight of stairs shall not have a vertical rise greater than what maximum distance between floor levels or landings?
1011.8
Rooftop structures like towers or spires that are constructed of noncombustible materials are permitted to be:
504.3 Exception
Insulated metal panel (IMP) installations shall not exhibit sustained flaming where tested in accordance with NFPA 268, unless protected on the outside with concrete or masonry not less than:
1409.7.3.4 Exception 2
Aluminum fascia must be not less than what minimum thickness?
1412.7
An Institutional Group I-1 facility housing not fewer than six and not more than 16 persons receiving custodial care shall be classified as which occupancy group?
308.2.3
Submittal documents, including construction documents, geotechnical report, and statement of special inspections, must be submitted in a minimum of how many sets (unless digital format is allowed)?
107.1
Which of the following conditions is specifically deemed an unsafe condition?
116.1
Walls and partitions around an adult changing table shall have a smooth, hard, nonabsorbent surface to a height of not less than what minimum distance above the floor?
1210.2.3
Where two or more exits or access to exits are required, not more than what fraction of the exits or exit access doorways shall be equipped with horizontal sliding or vertical security grilles?
1010.3.4
Chimneys must extend not less than 2 feet (610 mm) higher than any portion of the building within what maximum distance?
2113.9
Footings for masonry fireplaces and their chimneys must extend not less than what minimum distance beyond the face of the fireplace or foundation wall on all sides?
2111.3
In Group M occupancies, egress through stockrooms is permitted provided there is a demarcated, minimum 44-inch-wide (1118 mm) aisle defined by full- or partial-height fixed walls that leads directly from the retail area to the exit without:
1016.2 Item 2.4
The height limitation for buildings of Type IIA construction in Groups R-1 and R-2 shall be increased to nine stories and 100 feet (30 480 mm) where the building is separated by not less than what minimum distance from any other building on the lot and from lot lines?
510.6
Any full-height wall length, or portion thereof, less than what minimum length shall not be considered as a portion of the lateral force-resisting system under the Simplified Structural Design Procedure?
3114.8.5.3
Fire areas used to avoid exceeding the limits for requiring a fire protection system must be separated by fire walls, fire barriers, or horizontal assemblies having a minimum fire-resistance rating determined by which section?
901.7
According to Table 1705.8, inspecting drilling operations and maintaining complete and accurate records for each cast-in-place deep foundation element requires which type of inspection?
Table 1705.8 Item 1
In floodways, grading or fill shall not be approved unless it has been demonstrated that the proposed work will not result in any increase in flood levels during the occurrence of the design flood through hydrologic and hydraulic analyses performed by a:
1804.5 Item 2
Which of the following load combinations for sloped glass includes the smallest factor applied to the inward wind force (Wi)?
2404.2
For open valleys (valley lining exposed) lined with metal for asphalt shingles, the valley lining shall be not less than what minimum width?
1507.2.8.2
For rigid tile roof coverings, the single lapped interlocking tile must have a minimum head lap of not less than:
1609.6.3.1
Required public toilet facilities shall be provided with signs that indicate whether the facility is to be used by males, by females, or by whom else?
2902.4
Where parking is provided beneath a building, accessible parking spaces shall be provided:
1106.7.1
Where openings below grade provide required natural ventilation, the outside horizontal clear space measured perpendicular to the opening shall be what minimum ratio of the depth of the opening?
1202.5.1.2
The chimney wall or chimney flue lining shall not change in size or shape within what maximum distance above or below where the chimney passes through floor, ceiling, or roof components?
2113.6
In ambulatory care facilities, the required refuge area shall provide not less than what net square footage for each nonambulatory care recipient?
422.3.2
Interior floor finish materials of a traditional type, such as wood, vinyl, linoleum or terrazzo, are exempt from which general requirement?
804.1 Exception
Religious educational rooms and religious auditoriums accessory to places of religious worship with occupant loads of less than 100 per room shall be classified as which occupancy group?
305.1.1
Escalators and moving walks must be constructed of which materials, with exceptions for certain components?
3004.2
The cohesive/adhesive bond strength of the cured SFRM applied to floor, roof and wall assemblies and structural members must be not less than:
1705.15.6
What is the maximum number of elevator cars permitted in any single fire-resistance-rated hoistway enclosure?
3002.2
In addition to the primary inflation system, an auxiliary inflation system must be provided in air-supported and air-inflated structures larger than what minimum area?
3102.8.1.1
Single- and multiple-component spray-applied foam plastic insulation must comply with the provisions of Section 2603 and which standard?
2603.1.1
Where must directional signage indicating the route to the required public toilet facilities be posted?
2902.4.1
The design, detailing, fabrication, and erection of structural steel elements in seismic force-resisting systems other than those covered in Section 2202.2.1 must be in accordance with AISC 341 where the structure is assigned to Seismic Design Category D, E or F, except as permitted in which table?
2202.2.2 Item 1
Toilet facilities shall not open directly into a room used for what purpose?
2902.3.2
Asphalt shingles not included in the scope of ASTM D7158 must be tested and labeled in accordance with which standard?
1504.2 Exception
Unless otherwise specified, metal composite material (MCM) must have a flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in accordance with:
1406.9
Where lath on vertical surfaces extends between rafters or other similar projecting members, what must be installed to provide support for lath and attachments?
2510.5.1
For machinery, the weight of reciprocating machinery or power-driven units shall be increased by what percentage to allow for impact?
1607.12.2
What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) Group A-2 occupancy of Type IIIB construction?
Table 504.4
What is the Tabular allowable area factor in square feet for a nonsprinklered (NS) building classified as Group H-4 of Type IVC construction?
Table 506.2
Photovoltaic panels installed over open-grid framing or a noncombustible deck in elevated PV support structures must be tested, listed and labeled with a fire type rating in accordance with UL 1703 or with both UL 61730-1 and which other standard?
3111.3.5.1
The accessible route from any separate-sex toilet room to a family or assisted-use toilet room shall not exceed what maximum distance?
1110.2.1.4
Stairways within dwelling units shall have an illumination level on tread runs of not less than:
1204.4
In other than Group H occupancies, the force required to set a power-operated door in motion manually shall not exceed:
1010.3.2
All elevators must be equipped to operate with a standardized fire service elevator key in accordance with which code?
3003.3
In unlimited area Group A-4 occupancies used for participant sports areas where the automatic sprinkler system is not required in the sports area, what must be provided in storage rooms, press boxes, and concession booths ancillary to the sport activity space?
507.4 Exception 2
If a building has 50 percent of its perimeter fronting on an open space of 25 feet, what is the frontage increase factor?
506.3.3
For moist (A) or marine (C) climate zones, drainage on the exterior side of the water-resistive barrier must have a minimum drainage efficiency of what maximum percentage as measured in accordance with ASTM E2273 or Annex A2 of ASTM E2925?
2510.6.2
For preconstruction load tests, the test load shall be left in place for a period of:
1709.3.1
Concrete and masonry chimneys for medium-heat appliances must extend not less than 10 feet (3048 mm) higher than any portion of any building within what maximum distance?
2113.11.2.4
When using the Simplified Structural Design Procedure for single-unit containers, what is the value specified for the Overstrength factor?
3114.8.5.2
A mezzanine is NOT required to be open to the room where the aggregate occupant load of the enclosed space is not greater than:
505.2.3 Exception 1
For basic uniform live load reduction, the reduced design live load shall be not less than 0.50 L for members supporting how many floors?
1607.13.1
For a helipad, the takeoff weight limitation must be indicated in units of thousands of pounds and placed in a box that is located in the bottom right corner of the landing area, and this box shall be not less than what minimum height?
1607.6
Where controlled occupancy procedures are implemented, the emergency action plan must document the criteria for initiating occupant evacuation procedures for which environmental events, where applicable?
3103.8
For exterior exit stairways and ramps serving individual dwelling units of Group R-3, the minimum fire separation distance shall be not less than:
1027.5 Exception
Mineral-surfaced roll roofing shall not be applied on roof slopes below what minimum units vertical in 12 units horizontal?
1507.6.2
What is the Tabular allowable area factor in square feet for a building classified as Group M, two or more stories above grade plane (SM) of Type IIA construction?
Table 506.2
Test samples for determining SFRM density must be selected from each floor, roof and wall assembly at a rate of not less than one sample for every what minimum area?
1705.15.5 Item 1
Exterior metal veneer shall be securely attached to the supporting masonry or framing members, with the spacing of the fastenings or ties not exceeding 24 inches either vertically or horizontally, but where units exceed 4 square feet in area there shall be not less than:
1404.12.1
What is the maximum allowable quantity (in pounds) for storage of Corrosive materials (solid) per control area?
Table 307.1(2)
Continuous concrete footings supporting light-frame construction walls of buildings three stories or less above grade plane are exempt from special inspections if the specified compressive strength is not more than:
1705.3 Exception 2.3
The minimum size of combustible dust defined in the code is material that is 420 microns or less in diameter and which passes through a:
202 [F] Combustible Dust
According to Table 1705.3, what type of inspection is required for adhesive anchors installed in horizontally or upwardly inclined orientations to resist sustained tension loads?
Table 1705.3 Item 4.a
For metal roof shingles valley flashing, the splash diverter rib at the flow line formed as part of the flashing shall be not less than what minimum height?
1507.5.7
Rooftop-mounted photovoltaic (PV) panel systems and solar thermal collectors must be designed in accordance with which section regarding wind resistance?
3111.1.1
In Group R-2, R-3, and R-4 occupancies required to have Accessible, Type A, or Type B dwelling units, at least what percentage, but not less than one, of each type of parking space provided shall be accessible?
1106.3 Item 1
Shotcrete must be in accordance with the requirements of which standard?
1908.1
An accessible route shall be provided to at least 5 percent, but not less than one, of each type of:
1111.4.3
Each revolving door used as a component of a means of egress shall be credited with a capacity based on not more than a maximum occupant load of:
1010.3.1.1
For prescriptive concrete foundation walls, the specified compressive strength, f’c, shall be not less than:
1807.1.6.2 Item 6
Who must design excavation retention systems used to support an excavation for protection of adjacent property?
3307.2.1
Residential Group R-1 occupancies contain sleeping units where the occupants are primarily what nature?
310.2
Plaster applied to adobe masonry must be applied in not less than how many coats?
2109.2.4.8.3
According to Table 1508.2, which ASTM standard applies to High-density polyisocyanurate board used for roof insulation?
1508.2
An assistive listening system is not required where there is no audio amplification system, EXCEPT in which location?
1109.2.7 Exception
What classification applies to heavy timber frame-supported structures covered by an approved membrane in accordance with Section 3102.3.1?
3102.3
The minimum width for stairways serving an occupant load of less than 50 shall be not less than:
1011.2 Exception 1
Staples used in contact with preservative-treated wood must be made of which material?
2304.10.6.1
What is the maximum time allowed for a required standby power-generating system for an auxiliary inflation system to automatically start and transfer all required electrical functions at full power after normal electrical service failure?
3102.8.2
Where HPM piping is installed in corridors, the required ventilation shall be not less than:
415.11.7.4
Structural plain concrete basement, foundation or other walls below the base are permitted in detached one- and two-family dwellings assigned to Seismic Design Category D or E, provided the height of the wall does not exceed 8 feet and the wall retains not more than what maximum height of unbalanced fill?
1905.6.2 Item 1
For a horizontal wood-frame gypsum panel product diaphragm ceiling made of 1/2-inch material spaced at 16 inches on center, what is the maximum shear value permitted in plf of ceiling?
Table 2508.6
Cables listed in accordance with UL 2196 for survivability of required critical circuits serving fire service access elevators must have a minimum fire-resistance rating of how long?
3007.8.1
Parapet walls required by Section 705.12 must be coped or covered with weatherproof materials of a width not less than the thickness of the parapet wall such that the wall’s fire-resistance rating is not:
1503.3.1
If a notice of violation is not complied with promptly, the building official is authorized to request the legal counsel of the jurisdiction to institute proceedings to restrain, correct, or:
114.3
Where repairs, alterations, or additions are made during the restoration of a structure deemed unsafe, those actions must comply with the requirements of the:
116.5
Grab bars, shower seats, and accessible benches shall be designed to resist a single concentrated load of:
1607.9.2
Where the steel grade is not readily identifiable from marking and test records, what action must be taken to verify conformity to such standards?
2201.2
Vertical reinforcement in masonry chimneys must be enclosed within 1/4-inch (6.4 mm) ties or equivalent reinforcing spaced not to exceed what maximum distance on center in concrete?
2113.3.2
For exterior walls of buildings of Type I, II, III or IV construction of any height, if the wall is required to have a fire-resistance rating, what test standard must be used to substantiate that the fire-resistance rating is maintained?
2603.5.1
Tanks having a capacity of more than what maximum volume located on the roof deck of a building shall be supported on masonry, reinforced concrete, steel or heavy timber construction?
1511.3
Gypsum panel products shall not be used in diaphragm ceilings to resist lateral forces imposed by which types of construction?
2508.6.5
Who must contract a registered design professional for the design of the temporary installation restraint/bracing and the PITMR and PITMDB for wood trusses spanning 60 feet or greater?
2303.4.1.3
According to Table 2109.2.3.1, what is the minimum embedment (inches) required for a 7/8-inch-diameter bolt in adobe masonry?
2109.2.3.1
Aerial supports not greater than what maximum height as measured from the roof deck to the highest point on the aerial supports shall be permitted to be constructed of combustible materials?
1511.7.1 Exception
Nonclassified roof coverings shall be permitted on buildings of Group U occupancies where there is a minimum fire-separation distance of what minimum distance measured from the leading edge of the roof?
1505.1
Every stairway landing shall have a minimum depth, measured parallel to the direction of travel, equal to the width of the stairway or what maximum distance, whichever is less?
1011.6
In structures assigned to Seismic Design Category C or D, masonry fireplaces must be reinforced and anchored in accordance with Sections 2111.4.1, 2111.4.2, and:
2111.4
Recovering or replacing an existing roof covering shall not be required to meet the minimum design slope requirement of 1/4 unit vertical in 12 units horizontal for low-slope roof coverings if the roofs provide positive roof drainage and meet the requirements of Section 1608.3 and:
1512.1 Exception 1
An incidental use classified as a Furnace room where any piece of equipment is over 400,000 Btu per hour input requires which minimum protection?
Table 509.1
What is the minimum required fire-resistance rating for an exterior wall of a nonsprinklered Group F-1, M, or S-1 occupancy where the fire separation distance is 10 feet or greater and less than 30 feet, and the construction type is IIB or VB?
Table 705.5
Spiral stairways are permitted to be used as a component in the means of egress only within dwelling units or from a space not more than what maximum area?
1011.1
The primary purpose of these regulations is to establish minimum requirements to provide a reasonable level of safety, health and general welfare through all the following aspects EXCEPT:
101.3
What are the projection limitations for footings of street walls or their supports that are located not less than 8 feet (2438 mm) below grade?
3202.1.1
Combustible material directly above and within 12 inches (305 mm) of the fireplace opening shall not project more than what maximum distance for each 1-inch (25 mm) distance from such opening?
2111.12 Exception 4
Power-operated conveyors, belts, and other material-moving devices must be equipped with what automatic mechanism?
3004.3.2
Allowable shear values for wood structural panel diaphragms utilizing staples (Tables 2306.2(1) and 2306.2(2)) are permitted to be increased by what percentage for wind design?
2306.2
Masonry structures and components must comply with the seismic design requirements in Chapter 7 of TMS 402 depending on the structure’s:
2106.1
Mobile or portable amusement rides are:
1111.4.8 Exception
Intermodal shipping containers housing or supporting experimental equipment are exempt from the requirements of Section 3114, provided they are single stand-alone units supported at grade level and used only for occupancies under which Risk Category?
3114.1 Exception 4.1
Concrete and masonry chimneys containing more than one passageway must have the liners separated by a minimum what thickness of concrete or solid masonry wall?
2113.11.2.3
For an unlimited area building, where Section 507.2 requires yards to be measured, how is the distance determined?
507.2
Where Section 1803 does not require reporting of materials and procedures for fill placement, the special inspector must verify that the in-place dry density of the compacted fill is not less than what minimum percentage of the maximum dry density at optimum moisture content?
1705.6 Exception
Structural floor sheathing constructed of lumber placed perpendicular to supports (surfaced dry) must have a minimum net thickness of 3/4 inch when the maximum span is:
2304.8(1)
What type of barrier must separate the occupant evacuation elevator lobby from each floor?
3008.6.2
The shear values listed in Table 2508.6 shall be reduced by what percentage in Seismic Design Categories D, E, and F?
Table 2508.6 Note b
Cooling towers located on the roof deck of a building must be constructed of noncombustible materials if they are greater than 250 square feet in base area or greater than what maximum height above the roof deck, provided the roof is greater than 50 feet in height above grade plane?
1511.4
According to Table 1705.6, verifying materials below shallow foundations are adequate to achieve the design bearing capacity requires which type of inspection?
Table 1705.6 Item 1
In accordance with procedures, the official in charge of the enforcement agency shall be known as the:
103.1
For detailed plain concrete structural walls, horizontal reinforcement must be provided at a maximum spacing of:
1905.5.1
The provisions of Section 3103 apply to structures erected for a period of less than how many days?
3103.1
Class B materials shall be permitted as wainscotting extending not more than what distance above the finished floor in corridors and exit access stairways and ramps?
Table 803.13 Note j
Combustible materials shall not be placed within 36 inches (914 mm) of the outside surface of a masonry heater in accordance with NFPA 211, Section:
2112.5
Where a Type III, IV or V building has a fire separation distance of 60 feet or greater from a property lot line, what minimum water supply shall be provided?
3313.3.3
What must be discontinued and capped in accordance with the approved rules and requirements of the applicable governing authority during demolition?
3303.6
Nonstructural concrete with a freeze-thaw exposure Class F2 or F3 must have a minimum specified compressive strength, of not less than:
1904.2
Where more than one exit is required from a mall, the width of an exit passageway or corridor from the mall shall be not less than:
402.8.6
In a courtroom, the judge’s bench, clerk’s station, bailiff’s station, deputy clerk’s station and court reporter’s station shall be located on an accessible route, and vertical access to elevated work stations is not required at initial construction provided a ramp, lift or elevator can be installed without requiring reconfiguration or extension of the courtroom or:
1109.4.1.4
Isolated poles not adversely affected by a 1/2-inch motion at the ground surface due to short-term lateral loads shall be permitted to be designed using lateral bearing pressures equal to what factor multiplied by the tabular values in Table 1806.2?
1806.3.4
If an entrapment is verified, what must the elevator emergency two-way communication system enable authorized personnel to communicate?
3001.2
For slab-on-ground foundations on expansive soils, it is permitted to analyze and design such slabs by methods that account for soil-structure interaction, provided such alternative methods are rational and the basis for all aspects and parameters of the method shall be available for:
1808.6.2
Where required, the emergency power system for illumination shall provide power for a duration of not less than:
1008.3.1
If a fire assembly serves multiple purposes in a building, it must comply with:
702.1
An automatic sprinkler system is required throughout stories containing Group A-2 occupancies where the fire area exceeds:
903.2.1.2
For detailed plain concrete structural walls, continuous vertical reinforcement must be provided at each corner, at each side of each opening, and at the ends of walls, with a cross-sectional area of not less than:
1905.5.1
Any portion of a masonry fireplace located in the interior of a building or within the exterior wall must have a clearance to combustibles of not less than 2 inches (51 mm) from the front faces and sides, and not less than what minimum distance from the back faces?
2111.12
Design strengths and permissible stresses of structural material must conform to the specifications and methods of design of accepted engineering practice or the approved rules in the absence of:
1706.1
What is the maximum allowable building height in feet for a sprinklered (S) Group B occupancy of Type IV construction?
Table 504.3
Unless structural support and anchorage are provided, the center of gravity of projecting masonry or molded cornices must lie within what portion of the supporting wall?
2104.1.2
For structures assigned to Seismic Design Category D, E or F, individual spread footings founded on Site Class E or F shall be interconnected by ties, unless equivalent restraint is provided by reinforced concrete beams within slabs on grade or:
1809.13
Which of the following is an example of an Anchored Masonry Veneer?
202 [BS] Anchored Masonry Veneer
In high-rise buildings not classified as Group R-2 and more than 420 feet (128 m) in height, which of the following is prohibited from being considered the additional interior exit stairway required?
403.5.2
For conventional light-frame construction in Seismic Design Category C, the structure is limited to what maximum height?
2308.2.1
Impact protective systems must be tested for impact resistance for compliance with ASTM E1886 and ASTM E1996 and for design wind pressure for compliance with:
1709.5.3.1
Which professionals are permitted to act as special inspectors for the work designed by them, provided they qualify as special inspectors?
1704.2.1
Where a shaft terminates below the roof assembly, the top enclosure must have the same fire-resistance rating as the topmost floor penetrated by the shaft, but not less than the rating required for the:
713.12
Lateral force-resisting systems shall meet seismic detailing requirements and limitations prescribed in this code and ASCE 7 even where what other load effects are greater than seismic load effects?
1604.9
The concentrated load indicated in Table 1607.1 for stair treads shall be applied on an area of:
1607.2
What is the maximum allowable building height in feet for a Type IIA construction building classified as Group I-2 that is equipped throughout with an automatic sprinkler system (S)?
Table 504.3
Screens used for broken glass retention shall be constructed of a noncombustible material not thinner than No. 12 B&S gage (0.0808 inch) with mesh not larger than:
2405.3
According to Table 1607.1, what is the minimum uniformly distributed live load required for sidewalks and yards subject to trucking?
1607.1
The cost of all tests and other investigations required under the provisions of this code shall be borne by the owner or the:
1707.1
When different provisions specify different materials, methods of construction, or other requirements for a specific case, which requirement shall govern?
102.1
For a building with occupant evacuation elevators, building areas shall not contain hazardous materials exceeding the maximum allowable quantities per what defined space?
3008.1
If a fire wall separates Group F-2, S-2, R-3, or R-4 occupancies, what is the minimum required fire-resistance rating in hours?
Table 706.4
The lateral bearing pressures specified in Table 1806.2 shall be permitted to be increased by the tabular value for each additional foot of depth up to a value that is not greater than what factor multiplied by the tabular value?
1806.3.3
Live loads that exceed 100 psf shall not be reduced, except for members supporting two or more floors, where the reduction shall not be greater than:
1607.13.1.2
The egress analysis for full-building occupant evacuation must demonstrate that the number of evacuation elevators results in an evacuation time less than what maximum duration?
3008.1.1
What type of communication system is required in each elevator car?
3001.2
Doors to resident sleeping units in Group I-3 occupancies shall have a clear width of not less than:
408.3.1
According to Table 1507.3.7 for General Clay or Concrete Roof Tile on a roof slope of 3:12 and over, what is the attachment requirement for a maximum Allowable Stress Design Wind Speed (Vasd) of 85 mph and a mean roof height of 0–60 feet?
1507.3.7
Corridors, toilet rooms, kitchenettes and break rooms are specifically excluded from the definition of an:
202 [BE] Employee Work Area
Backfill placed outside the foundation must be free of organic material, construction debris, cobbles and boulders, or must be a:
1804.3
What is the maximum allowable number of stories above grade plane for a sprinklered (S) building classified as Group M of Type IIIB construction?
Table 504.4
The upward pressure of water on basement floors, slabs on ground, and foundations shall be taken as the full hydrostatic pressure applied over the entire area, with the hydrostatic load measured from the:
1610.2
Building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening in an interior exit stairway or ramp shall have a fire-resistance rating of not less than:
1023.7.1
Fire-retardant-treated wood shakes and shingles shall be treated by impregnation with chemicals by the full-cell vacuum-pressure process, in accordance with:
1505.6
Glass in elevator enclosures must comply with which section?
3002.8
What is the minimum required depth for a water closet compartment utilizing a floor-mounted water closet?
2903.1.1
What is the minimum required fire-resistance rating in hours for exterior bearing walls in Type IV-C construction?
Table 601
In auditoriums, theaters, concert or opera halls, the illumination at the walking surface is permitted to be reduced during performances by one of two methods, provided that the required illumination is automatically restored upon activation of a premises’:
1008.2.1 Exception
Base flashing for asphalt shingles shall be of corrosion-resistant metal of minimum nominal 0.019-inch thickness or mineral-surfaced roll roofing weighing not less than what minimum weight per 100 square feet?
1507.2.8.1
Ambulatory care facilities and Group I-2 occupancies must be ventilated by mechanical means in accordance with which section of the International Mechanical Code?
1202.1
According to Table 1607.1, what is the minimum uniformly distributed live load required for a dance hall or ballroom?
1607.1
The inside height of the smoke chamber from the fireplace throat to the beginning of the flue shall be not greater than the:
2111.9.1
Where the fireplace opening is 6 square feet (0.557 m2) or larger, the hearth extension shall extend not less than 20 inches (508 mm) in front of, and not less than what minimum distance beyond, each side of the fireplace opening?
2111.11
The aggregate area of openings for projection equipment shall not exceed what percentage of the area of the wall between the projection room and the auditorium?
409.2
Where a building is equipped throughout with an automatic sprinkler system, the maximum percentage area of exterior wall in light-transmitting plastic wall panels given in Table 2607.4 can be increased by what percentage?
2607.5
Impervious surfaces within 10 feet of the building foundation shall be sloped not less than what minimum percentage away from the building?
1804.4
Separate toilet facilities shall not be required in mercantile occupancies where the maximum occupant load is what number or fewer?
2902.2 Exception
Flashing, where made of metal, must be corrosion resistant with a thickness of not less than:
1503.2.1
A Class I interior floor finish material must have a minimum critical radiant flux of:
804.2
Where plastic cement or masonry cement is used in exterior plaster, what restriction applies regarding additional lime or plasticizers?
2512.2
A liquid-applied protective coating shall be applied to polyurethane foam roofs not less than 2 hours nor more than what maximum duration following the application of the foam?
1507.13.3
Vegetative roofs shall be installed in accordance with which standard?
1505.1
Inspections of penetration firestop systems tested and listed in accordance with Sections 714.4.1.2 and 714.5.1.2 must be conducted by an approved agency in accordance with:
1705.18.1
Family or assisted-use toilet rooms shall be located not more than how many story above or below separate-sex toilet rooms?
1110.2.1.4
The water-resistive barrier for EIFS with drainage shall comply with Section 1403.2 or:
1407.4.1.1
What must the label contain, in addition to the manufacturer’s identification and definitive performance characteristics?
1703.5.3
Emergency and standby power must be provided in underground buildings as required in which section?
2702.2.19
According to Table 903.2.5.2, what is the required Occupancy Hazard Classification for Fabrication areas in a Group H-5 occupancy?
Table 903.2.5.2
High-rise buildings assigned to Risk Category III or IV shall comply with the requirements of Section 1616.2 if they are frame structures, or Section 1616.3 if they are:
1616.1
The applicant must submit a statement of special inspections in accordance with Section 107.1 as a condition for:
1704.2.3
Towers are required to be noncombustible, but what is the maximum height permitted for single free-standing poles used to support antennas that are not required to be noncombustible?
3108.1 Exception
The design displacement shall be the Design Earthquake Displacement, defined in which section of ASCE 7?
1902.1.1
Exterior Insulation and Finish Systems (EIFS) with drainage is required on framed walls of Type V construction serving which occupancy groups?
1407.4.1
Where an occupiable roof has an assembly occupancy, automatic sprinkler system protection is required on all floors between the occupiable roof and the level of exit discharge if the occupant load exceeds 100 for Group A-2 and how many persons for other Group A occupancies?
903.2.1.5
Wood poles embedded in earth shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B) for sawn timber posts and (Commodity Specification B, Use Category 4B) for:
1807.3.1
Metal composite material (MCM) systems used as exterior wall covering or as elements of balconies and similar projections to provide cladding or weather resistance must comply with which sections?
1406.2
Which fastener material is acceptable for all types of metal roofs?
1507.4.4
For exterior adhered masonry veneer installed with lath and mortar, the scratch coat is created by scoring the surface horizontally of a nominal 1/2-inch-thick layer of mortar that is applied encapsulating the:
1404.11.1.4.2
The total thickness of base coat plaster applied to concrete ceilings shall be as set forth in ASTM C842 or ASTM C926. If the ceiling surfaces require more than the maximum permitted thickness, what additional step must be taken before plastering?
2511.4
Underlayment installed for BIPV roof panels where the allowable stress design wind speed (Vasd) is not less than 120 mph must comply with ASTM D226, Type III, ASTM D4869, Type IV or:
1507.17.4.1
Passenger elevators required to be accessible or serve as part of an accessible means of egress must comply with which sections?
3001.4
Essential electrical systems for Group I-2 occupancies shall be in accordance with which section?
2702.2.8
Inverters used in photovoltaic solar energy systems connected to the utility grid must be listed and labeled in accordance with which UL standard?
3111.3.1
According to Table 1507.2.8.2, what is the minimum required weight for Cold-rolled copper valley lining material?
1507.2.8.2
An open parking garage of Type II construction with all sides open shall be unlimited in allowable area where the building height does not exceed:
406.5.5
Where a diaphragm is not permitted to be idealized as either flexible or rigid, the structure shall be analyzed and designed utilizing an envelope analysis of the structure using a flexible and rigid diaphragm analysis separately and designing each component for the:
1604.4
If a conflict occurs between provisions of this code and a referenced code or standard, which provision shall apply?
102.4.1
For fireplaces with chimneys up to 40 inches (1016 mm) wide in Seismic Design Category C or D, how many continuous vertical bars must be provided?
2111.4.1
The Building Area is the area included within surrounding exterior walls, or exterior walls and fire walls, exclusive of vent shafts and:
202 [BG] Area, Building
Buildings containing materials that pose a deflagration hazard, such as Class I flammable liquids stored in normally open containers, shall be classified as which High-Hazard Group?
307.4
At least what percentage, but not less than one, of each type of firing position at shooting facilities shall be accessible?
1111.4.15
Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses and company names and logos are:
1112.6 Exceptions
Which building component is designated in Table 601 and may or may not be of fire-resistance-rated construction, with materials based on the building type of construction?
202 [BG] Building Element
The openable area of openings to the outdoors for natural ventilation of an occupied space shall be not less than what minimum percentage of the floor area being ventilated?
1202.5.1
For structures assigned to Seismic Design Category C, D, E or F, the geotechnical investigation must include an evaluation of all of the following potential geologic and seismic hazards EXCEPT:
1803.5.11
What is the minimum required fire-resistance rating in hours for interior bearing walls in a Type VA building?
Table 601
The reference plane representing the average of finished ground level adjoining the building at exterior walls is the:
202 [BG] Grade Plane
The required sample size for SFRM inspection shall not exceed what maximum percentage of that specified by the referenced standards in Sections 1705.15.4.1 through 1705.15.4.9?
1705.15
For seismic force-resisting systems of structures assigned to Seismic Design Category C, D, E or F, continuous special inspection is required during:
1705.13.2 Item 1
To qualify for the exemption allowance for corrosive consumer products in retail display, individual containers shall not exceed:
Table 307.1.1
Where 10d common nails (3″ x 0.148″) are substituted for 16d common nails (3 1/2″ x 0.162″) in rafter tie heel joint connections, the required number of 10d nails must be what factor multiplied by the required number of 16d common nails, rounded up?
2308.11.3.1
The response modification coefficient, R, designated for “Steel systems not specifically detailed for seismic resistance, excluding cantilever column systems” shall be permitted for cold-formed steel systems designed and detailed in accordance with AISI S100, and such systems need not be designed and detailed in accordance with which other standard?
2204.2.2
When testing the ignition characteristics of exterior walls in accordance with NFPA 268, assemblies protected on the outside with a minimum 7/8-inch (22.2 mm) thickness of stucco complying with Section 2510 are exempt from sustained flaming requirements, as are assemblies protected with minimum 1-inch thickness of concrete or:
2603.5.7 Exception
Where structural components of a prefabricated assembly are not visible for inspection, the owner or authorized agent must submit a report that must be approved by the:
1703.6
The triangular openings at the open sides of a stair shall not allow passage of a sphere of what maximum diameter?
1015.4 Exception 2
The thermal barrier is required on the underside of a structural floor system containing foam plastic insulation if the underside of the structural floor system is exposed to:
2603.4.1.14
Who is responsible for conducting a daily fire safety inspection at the project site?
3302.3
According to Table 1607.1, what is the minimum uniformly distributed live load required for a library reading room?
1607.1
What is the defined maximum size for a metal can or plastic container designed and intended to dispense an aerosol?
202 [F] Aerosol Container
What is the maximum permitted classification for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby?
Table 803.13 Note d
The shear values listed in Table 2508.6 shall be reduced by what percentage for normal loading?
Table 2508.6 Note a
The maximum allowable quantity of Class IA flammable liquid in wholesale and retail sales occupancies per control area in a nonsprinklered building is:
Table 414.2.5.2
For horizontal building separation allowance, what type of construction must the building below the horizontal assembly be?
510.2
Plaster shall be applied when the ambient temperature is higher than what minimum temperature, unless provisions are made to keep cement plaster work above this temperature during application and 48 hours thereafter?
2512.4
Who must employ one or more approved agencies to provide special inspections and tests during construction when application is made for construction?
1704.2
Low-level exit signs required in Group R-1 occupancies must have the bottom of the sign located not less than 10 inches (254 mm) nor more than what maximum distance above the floor level?
1013.2
For clay and concrete tile valley flashing, the valley flashing shall extend not less than what minimum distance from the centerline each way?
1507.3.9
To qualify for unlimited area in a one-story Group E building of Type II, IIIA or IV construction, each classroom must have not less than two means of egress, with one being a direct exit to the outside complying with which section?
507.11
Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed what maximum weight?
1010.1.3
Unless otherwise specified by the approved manufacturer’s instructions, fasteners for vertical vinyl siding shall be spaced not greater than:
1404.15.1.3
Doors or other devices at the point of access to an elevator car are prohibited, unless they are readily openable from inside the car without which items?
3002.6
Unless otherwise specified, high-pressure decorative exterior-grade compact laminates (HPL) shall have a flame spread index of 75 or less and a smoke-developed index of 450 or less when tested in accordance with:
1408.9
Where stairways serve more than one story, or more than one story and an occupiable roof, which factor shall be used when calculating the required number of exits or access to exits serving that story?
1006.3.1
Factory-built or masonry fireplaces must be equipped with an exterior air supply unless the room is mechanically ventilated and controlled so that the indoor pressure is:
2111.14
What defines an Exterior Wall in terms of slope with the horizontal plane?
202 [BF] Exterior Wall
The building official is authorized to disconnect utility service in case of emergency where necessary to eliminate an immediate hazard to life or property, or when the utility connection:
112.3
Continuous Insulation (CI) is insulating material that is continuous across all structural members without thermal bridges other than fasteners and:
202 [BF] Continuous Insulation (CI)
What is the maximum exit access travel distance permitted on a pedestrian walkway that is constructed with both sides not less than 50 percent open, and equipped throughout with an automatic sprinkler system?
3104.9 Exception 3
Built-up roofs shall have a design slope of not less than 1/4 unit vertical in 12 units horizontal for drainage, except for coal-tar built-up roofs that shall have a design slope of not less than:
1507.10.1
Load-bearing wall and partition assemblies must sustain the test load both with and without:
1709.4
The first coat of exterior cement plaster must be moist cured for a minimum period of how long?
Table 2512.6
Accessible parking spaces shall be located on the shortest accessible route of travel from adjacent parking to an accessible building entrance, except in multilevel parking structures where van-accessible parking spaces are permitted on:
1106.7 Exception 1
Interior adhered masonry veneers shall have a maximum weight of 20 pounds per square foot, and where supported by wood construction, the supporting members shall be designed to limit deflection to what maximum fraction of the span?
1404.11.3
The deflection of reinforced concrete structural members shall not exceed that permitted by which referenced standard?
1604.3.2
What is the maximum time period, in days, that occupancy of a dwelling unit or sleeping unit is classified as Transient?
202 [BG] Transient
A day care facility within a dwelling unit having five or fewer children receiving day care shall be classified as which occupancy group?
305.2.3
Screens are required to be installed below the full area of the glazing material for monolithic systems using heat-strengthened glass and:
2405.3.1
The required fire-resistance rating for a fire barrier separating dressing rooms from a stage with a height greater than 50 feet (15 240 mm) is not less than:
410.4.1
In assembly areas with a seating capacity of 1,001 to 2,000, the minimum number of receivers required to be hearing-aid compatible is what fraction of the total required receivers?
Table 1109.2.7.1
Seismic reinforcing is not required within the body of a masonry heater if the height is equal to or less than what maximum multiple of its body width?
2112.4
Standby power systems shall be provided for elevators and platform lifts as required in Sections 1009.4.1, 1009.5, 3003.1, 3007.8 and which other section?
2702.2.2
What is the Tabular allowable area factor in square feet for a building classified as Group S-1, two or more stories above grade plane (SM) of Type IIIB construction?
Table 506.2
What is the minimum required floor area for an enclosed fire service access elevator lobby, regardless of the number of elevators served?
3007.6.4
Where an elevation change of 30 inches (762 mm) or less occurs between a cross aisle and the adjacent floor or grade below, guards not less than what distance above the aisle floor shall be provided?
1030.17.2
When seismic loads are required, which seismic design parameter must be indicated on the construction documents?
1603.1.5
Plastering gypsum plaster or cement plaster shall be not less than three coats where applied over metal lath or wire fabric lath, and not less than how many coats where applied over other permitted bases?
2511.1
Glass in vision panels in elevator hoistway doors must be any transparent glazing material not less than what minimum thickness?
2409.3
A geotechnical investigation is required to determine if groundwater is above or within what maximum distance below the elevation of the lowest floor level, where such floor is located below the finished ground level adjacent to the foundation?
1803.5.4 Item 1
Luminous egress path demarcation lines on stair landings and other floor areas shall be placed on the wall with the bottom edge of the stripe not more than what distance above the finished floor?
1025.2.4.2
Glass and glazing used in greenhouses shall comply with which section?
3112.4
According to Table 415.6.5, for Class 2 Oxidizer, liquids and solids, a detached building is required where the quantity of material exceeds:
Table 415.6.5
According to Table 2406.2(1), what is the minimum CPSC Category class required for glazing in doors if the exposed surface area is more than 9 square feet?
2406.2
What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) building classified as Group E of Type VA construction?
Table 504.4
According to Table 1807.1.6.2, for a 7-foot maximum wall height, 7-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft, what is the minimum vertical reinforcement required for a 7.5-inch minimum wall thickness?
1807.1.6.2
Chemical-resistant furan mortar and grout used for ceramic tile installation must comply with which ANSI standard?
2103.2.3.4
Welded splices are prohibited in what specific zones of intermediate or special reinforced masonry walls?
2108.3
What must be provided for utility fixtures during the progress of the work?
3308.2
According to Table 1507.2.8.2, what is the minimum required thickness for Aluminum valley lining material?
1507.2.8.2
The width of joints between firebricks in a masonry firebox shall be not greater than:
2111.6
How must areaways below grade be protected?
3202.1.3
Emergency alarm initiating devices shall be installed outside of each interior exit or exit access doorway of rooms used for the storage of:
415.5.1
At least one accessible route shall connect accessible buildings, facilities, elements and spaces that are:
1104.2
Combustible trim, excluding handrails and guardrails, shall not exceed what maximum percentage of the specific wall or ceiling area to which it is attached?
806.6
Special inspections and nondestructive testing of structural steel elements must be in accordance with the quality assurance inspection requirements of:
1705.2.1
When a Group B or M building below a horizontal assembly is of Type IB or II construction, but not less than the type of construction required for the Group S-2 open parking garage above, what is the maximum height permitted for the lower building?
510.8 Exception
What is the minimum required fire-resistance rating in hours for the primary structural frame in a Type IB building?
Table 601
Single-ply membrane roofs shall have a design slope of not less than what minimum units vertical in 12 units horizontal for drainage?
1507.12.1
Ramped aisles having a slope exceeding one unit vertical in 15 units horizontal (6.7-percent slope) and stepped aisles shall be provided with handrails located either at one or both sides of the aisle or:
1030.16
Which alternative allowable stress load combination is represented by D + L + 0.6W?
1605.2
The tolerance between the largest and smallest riser height or between the largest and smallest tread depth shall not exceed what maximum distance in any flight of stairs?
1011.5.4
The legal occupancy of a structure existing on the date of adoption shall be permitted to continue without change, except as otherwise specifically provided in the code, the International Existing Building Code, the International Fire Code, or the:
102.6
A water closet, urinal, lavatory, or bidet shall not be set closer than what minimum distance from its center to any side wall, partition, vanity, or other obstruction?
2903.1.1
The fire-resistance rating of supporting structural members and assemblies shall be not less than the rating required for the fire-resistance-rated assemblies supported, EXCEPT for supports of fire partitions as provided in which section?
704.1.1
Where the allowable stress design load combinations of ASCE 7, Section 2.4 are used, and flat roof snow loads exceed 45 pounds per square foot, what percentage of the snow load shall be combined with seismic loads?
1605.1 Exception 2
Clear space between a handrail and a wall or other surface shall be not less than:
1014.8
Side-hinged swinging doors, pivoted doors, and balanced doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of how many or more persons?
1010.1.2.1
A parapet wall must have noncombustible faces for the uppermost minimum of:
705.12.1
In buildings of Type I or II construction, partitions dividing portions of stores occupied by one tenant only and that do not establish a corridor serving an occupant load of 30 or more are permitted to be constructed of wood panels or similar light construction up to what maximum height?
603.1
In general-purpose hospitals, psychiatric facilities, and detoxification facilities (Group I-2), at least what percentage, but not less than one, of the dwelling units and sleeping units shall be Accessible units?
1108.5.3.1
The exterior air outlet for a masonry fireplace is permitted to be located in the back or sides of the firebox chamber or within what maximum distance of the firebox opening on or near the floor?
2111.14.6
A vapor retarder is not required for unheated storage rooms having an area of less than:
1907.4 Exception 2
The permanent open space of 60 feet (18 288 mm) for a covered mall building is permitted to be reduced to not less than 40 feet (12 192 mm) provided the exterior wall facing the reduced open space has a fire-resistance rating of not less than:
402.2 Exception
The minimum slope for standing-seam metal roof panel systems shall be:
1507.4.2
What is required documentation for the site safety director and fire watch personnel?
3302.1.1
Anchor buildings of not more than three stories above grade plane with the same occupancy as mall tenants shall be separated from the mall building by:
402.4.2.2 Exception
According to Table 1808.8.1, what is the minimum specified compressive strength (*f’*c) required for precast prestressed driven piles?
1808.8.1
For vinyl siding attached to wood construction, nails used to fasten the siding and accessories must be corrosion resistant, and penetration into nailable substrate shall be not less than:
1404.15.1.1
Fire-retardant-treated wood exposed to weather, damp, or wet locations must be identified as “Exterior” to indicate there is no increase in the listed flame spread index when subjected to which test standard?
2303.2.7
Cross-laminated timbers must be manufactured and identified in accordance with which standard?
2303.1.4
An approved agency must disclose possible conflicts of interest to the building official and the registered design professional in responsible charge so that:
1703.1.1
What is the minimum thickness of masonry or concrete required to cover foam plastic insulation on each face when installed in a masonry or concrete wall, floor, or roof system to exempt it from thermal barrier requirements?
2603.4.1.1
Where a building contains more than one occupancy group, it shall comply with the applicable provisions of Section 508.2, 508.3, 508.4, 508.5, or a combination of these sections, but NOT with:
508.1 Exception 1
In assembly areas with a seating capacity of 51 to 200, the minimum required number of receivers for the assistive listening system is 2, plus one receiver for every how many seats over 50 seats?
Table 1109.2.7.1
In Climate Zone 4 (except Marine), use of a Class III vapor retarder is permitted only where the frame wall assembly complies with:
1404.3
The landing length for means of egress ramps shall be what minimum distance?
1012.6.3
What is the required construction type for pedestrian walkways?
3104.3
What is the minimum required fire-resistance rating in hours for interior bearing walls in Type IV-HT construction when supporting more than two floors or more than a floor and a roof?
Table 601, Footnote g
What is the maximum allowable number of stories above grade plane for a nonsprinklered (NS) building classified as Group H-2 of Type IIB construction?
Table 504.4
An Institutional Group I-3 facility (Condition 1) is characterized by allowing free movement to the exterior via means of egress without:
308.4.1
In dining and drinking areas, an accessible route to dining and drinking areas in a mezzanine is not required, provided that the mezzanine contains less than what percentage of the total combined area for dining and drinking and the same services are provided in the accessible area?
1109.2.9 Exception 2
Construction work requiring special inspection or testing must remain accessible and exposed until:
1704.2.2
Telecommunication and broadcast towers shall be designed and constructed in accordance with which standard?
3108.1
In Group M occupancies, egress through stockrooms is permitted provided not more than what maximum percentage of the exit access is through the stockroom?
1016.2 Item 2.2
The minimum nominal tensile strength for vertical ties within a bearing wall shall be equal to the weight of the wall within that story plus the weight of the diaphragm tributary to the wall in which story?
1616.3.2.4
Concrete tie beams for adobe exterior walls and interior load-bearing walls must be continuously reinforced with not fewer than how many No. 4 reinforcing bars?
2109.2.4.7.1
Where furring and furring attachments penetrate foam sheathing to connect to masonry or concrete construction, the fasteners used must be approved for application into masonry or concrete material and shall be installed in accordance with the:
1404.5.1
Where High-Density Polyethylene (HDPE) or Polypropylene (PP) is used as an interior finish, it must comply with which specific section?
803.9
Where lockers constructed of combustible materials are used, the lockers must be considered to be interior finish and must comply with which section?
806.8
Metal composite material (MCM) must be separated from the interior of a building by an approved thermal barrier consisting of 1/2-inch gypsum wallboard or material tested in accordance with and meeting the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of:
1406.10.2
For pier and curtain wall foundations, the unsupported height of the masonry piers shall not exceed what maximum factor multiplied by their least dimension?
1809.10 Item 3.1
Soil materials for geotechnical investigations must be classified in accordance with which ASTM standard?
1803.5.1
Flue lining systems for residential-type appliances are permitted to comply with clay flue lining requirements, listed chimney lining systems complying with UL 1777, or:
2113.11.1
Fire department glass access panels must be constructed of:
2406.5
Skylights set at an angle of less than 45 degrees (0.79 rad) from the horizontal plane shall be mounted not less than 4 inches (102 mm) above the plane of the roof on a:
2405.4
Periodic special inspection is required for the anchorage of electrical equipment for emergency and standby power systems in structures assigned to which Seismic Design Categories?
1705.13.6 Item 1
For Group R-4 occupancies protected by an automatic sprinkler system installed in accordance with Section 903.3.1.3, the exit access travel distance shall be not more than what distance?
1006.2.2.6
Special inspections of mass timber elements in Types IV-A, IV-B and IV-C construction shall be in accordance with which table?
1705.5.3
For unvented attics in Climate Zone 7, what is the minimum R-value of air-impermeable insulation required, expressed as a percentage of the total R-value, for condensation control?
Table 1202.3
For vertical patterned glass (sloped 15 degrees or less from vertical), the design equation (Equation 24-9) requires the wind load (Fgw) to be less than what multiple of the nonfactored load (Fge)?
2404.3.3
According to Table 1507.1.1(1), for Clay and concrete tiles installed outside hurricane-prone regions where the maximum basic wind speed (V) is 140 mph, which underlayment standard is NOT listed as compliant?
1507.1.1
Reinforcement larger than what size must be spliced using mechanical connections in accordance with Section 6.1.7.2 of TMS 402?
2107.3
Prescriptive concrete and masonry foundation walls must be designed and constructed in accordance with Section 1807.1.6 and must be laterally supported at the top and:
1807.1.6
Construction documents for buildings constructed using conventional light-frame provisions must include which wind design speed in accordance with Section 1609.3.1?
1603.1 Exception
Fire partitions used for dwelling unit and sleeping unit separations in buildings of Types IIB, IIIB, and VB construction shall have a minimum fire-resistance rating of 1/2 hour, provided the building is equipped throughout with an:
708.3 Exception 2
Handrails and guards shall be designed to resist a linear load of what minimum value in accordance with Section 4.5.1.1 of ASCE 7?
1607.9.1.1
Clay and concrete roof tile shall be installed on roof slopes of what minimum units vertical in 12 units horizontal?
1507.3.2
According to Table 1609.2 for windborne debris protection, what is the maximum fastener spacing required for a No. 10 wood-screw-based anchor used on a panel span between 4 feet and 6 feet?
1609.2
A Building or structure is deemed to have sustained Substantial Damage if the cost of restoring it to its before-damaged condition would equal or exceed what percentage of the structure’s market value before the damage occurred?
202 [BS] Substantial Damage
Flammable Vapors or Fumes are defined by a concentration of flammable constituents in air that exceeds what percentage of their lower flammable limit (LFL)?
202 [F] Flammable Vapors or Fumes
Openings in a fire barrier shall be limited to a maximum aggregate width of 25 percent of the length of the wall, and the maximum area of any single opening shall not exceed 156 square feet, EXCEPT where the opening protective has been tested to ASTM E119 or UL 263 and has a minimum fire-resistance rating of:
707.6 Exception 3
According to Table 1705.2.4, which type of special inspection is required for standard bridging of open-web steel joists?
Table 1705.2.4 Item 1.b.1
If an excavation is located 5 feet or less from the street lot line, what is the minimum required height of the barrier enclosing it?
3306.9
In Group H-2 and H-3 occupancies, not less than what percentage of the perimeter wall of the occupancy shall be an exterior wall?
415.6
Where food service lines are provided, and self-service shelves are present, at least what percentage, but not less than one, of each type of self-service shelf provided shall be accessible?
1110.16.3
Where the design wind pressure for vinyl siding or insulated vinyl siding exceeds 30 pounds per square foot, compliance with Chapter 16 must be demonstrated by:
1404.15
For fire service access elevators, in which specific locations are automatic sprinklers prohibited?
3007.2.1
Ventilation (other than the percentage of openings required in Section 406.5.2) shall be required for an open parking garage:
406.5.10
The design and installation of steel connections must be in accordance with the applicable referenced standards within this chapter, and for special inspection of welding or installation of high-strength bolts, which section applies?
2201.4
Access to exits is permitted by way of a dead-end mall that does not exceed a length equal to:
402.8.6 Exception
For water closets designed for assisted toileting, the clearance around the water closet shall be not less than what minimum width?
1110.2.2.2.1
In multilevel assembly seating areas utilized for worship services, if the second floor or mezzanine level contains 25 percent or less of the total seating capacity, wheelchair spaces are permitted to all be located where?
1109.2.4 Exception 1
Where a roof hatch or trap door provides access to an unoccupiable roof, the minimum area shall be not less than:
1011.12.2 Exception
The maximum allowable quantity for use in closed systems of Flammable Solid (solid) per control area is:
Table 307.1(1)
If the 60-foot (18 288 mm) public ways or yards are reduced to 40 feet (12 192 mm), what is the minimum required fire protection rating for the opening protectives in the exterior walls facing the reduced width?
507.2.1
The screen or chimney cap of a spark arrestor must be removable to allow for:
2113.9.2 Item 4
What is the maximum horizontal floor area permitted between draftstops in combustible floor/ceiling assemblies in occupancies other than Group R?
718.3
Interior stairway means of egress doors shall be openable from both sides without the use of a key or special knowledge or effort, EXCEPT that stairway discharge doors shall be openable from the egress side and shall only be locked from which side?
1010.2.6 Exception 1
The actual time that a person is an occupant within a facility for the purpose of receiving care is known as:
202 [BG] 24-Hour Basis
The minimum clear width of a means of egress ramp between handrails or other permissible projections shall be:
1012.5.1
Where accessible parking is provided, how many accessible spaces are required for a parking facility providing 101 total parking spaces?
Table 1106.2
For delayed egress systems (Section 1010.2.12), an attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds, EXCEPT where approved, a delay of not more than what maximum duration is permitted?
1010.2.12.1 Item 4 Exception
Where minimum 1x wood furring is used to attach cladding over foam sheathing to a 33 mil cold-formed steel stud using a #10 screw, with a cladding weight of 11 psf and a fastener spacing in the furring of 12 inches, what is the maximum thickness of foam sheathing permitted (in inches) according to Table 1404.5.2.2 (assuming 16 inches on center furring)?
1404.5.2.2
What is the maximum number of tiers allowed for a Type IB mechanical-access open parking garage that is NOT equipped with an automatic sprinkler system?
Table 406.5.4
Where the design wind pressure for aluminum fascia exceeds 30 pounds per square foot, the top edge of the fascia is permitted to be secured using utility trim installed beneath the drip edge with snap locks punched into the fascia spaced not greater than:
1412.7.2
For roofing assemblies, a thermal barrier is not required if the roof assembly with foam plastic insulation passes which standard test?
2603.4.1.5
Where adult changing stations are required in assembly and mercantile occupancies, it is based on the requirement of family or assisted-use toilet or bathing rooms, which is triggered when an aggregate of how many or more male and female water closets are required?
1110.4.1 Item 1, 1110.2.1
The upper edge of the cleanout opening in a masonry chimney shall be located not less than 6 inches (152 mm) below the:
2113.18
For a constructed covered walkway (Exception to 3306.7), what are the minimum dimensions required for members used to knee brace the posts to joists and stringers?
3306.7 Exception
Two or more buildings on the same lot shall be regulated as separate buildings unless which condition is met?
503.1.2
What is the minimum thickness required for particleboard floor underlayment conforming to Type PBU of ANSI A208.1?
2303.1.8.1
A Water-Reactive Material Class 3 reacts explosively with water without requiring:
202 [F] Class 3
Where a technical opinion and report is required by the building official to determine compliance, who must provide the report without charge to the jurisdiction?
104.2.2.1
An automatic sprinkler system is required throughout a Group M fire area used for the display and sale of upholstered furniture or mattresses where the area exceeds:
903.2.7.2
Deflagration is an exothermic reaction in which the reaction progresses through the unburned material at a rate less than the velocity of:
202 [F] Deflagration
Which standard governs cold-formed steel studs and track that are nonstructural?
Table 2506.2
A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than how many stories?
1023.9
For natural lighting purposes, an opening between an interior room and an adjoining room must be unobstructed and open across not less than what fraction of the common wall area?
1204.2.1
Type 1 mechanical splices are prohibited from being used within a plastic hinge zone or within a beam-column joint of intermediate or special reinforced masonry shear walls, but what type of mechanical splice is permitted in any location within a member?
2108.3
According to Table 722.2.2.1, what is the minimum required slab thickness in inches for a 2-hour fire-resistance rating when using siliceous aggregate concrete?
Table 722.2.2.1
For closed valleys (valleys covered with shingles) used with asphalt shingles, valley lining of one ply of smooth roll roofing complying with ASTM D6380 shall be permitted, and must be not less than what minimum width?
1507.2.8.2
The nonresidential area function within a live/work unit shall be limited to which floor level(s)?
508.5.1
The minimum thickness of fireplace hearths shall be:
2111.10.1
According to Table 1607.1, what is the minimum uniformly distributed live load required for uninhabitable attics with storage in one- and two-family dwellings?
1607.1
When must the site safety plan be submitted and approved?
3302.1
Metal edge systems, except gutters and counterflashing, installed on low-slope built-up, modified bitumen, and single-ply roof systems shall be tested for resistance in accordance with Test Methods RE-1, RE-2 and RE-3 of:
1504.6
Special inspections and tests of masonry construction shall be performed in accordance with the quality assurance program requirements of which standards?
1705.4
What is the required interior wall and ceiling finish classification for interior exit stairways and ramps in a nonsprinklered Group A-2 occupancy?
Table 803.13
If discrepancies noted during inspection are not corrected, they must be brought to the attention of the building official and the registered design professional in responsible charge prior to the completion of:
1704.2.4
In Group I-3 occupancies, door openings to resident sleeping units that are not required to be an Accessible unit shall have a minimum clear opening width of what distance?
1010.1.1 Exception 2
For determining deflection limits in Table 1604.3, the snow load is permitted to be taken as what factor multiplied by the design snow load determined in accordance with Section 1608.1?
1604.3
The registered design professional must have a fully qualified representative on site during all:
1803.4
Where gypsum sheathing is used as a backing for metal or wire fabric lath and cement plaster on walls, what must be provided in accordance with Section 2510.6?
2510.5.2.2
Foam plastic insulation complying with ASTM C578 and ASTM C1289 and used as exterior wall sheathing on framed wall assemblies must comply with ANSI/SBCA FS 100 for:
2603.1
Two-way communication systems at elevator landings shall provide communication between each required location and the fire command center or a central control point location approved by the fire department. If the central control point is not a constantly attended location, the system must have timed, automatic telephone dial-out capability to an approved supervising station or:
1009.8.1
Group A-3 buildings of Type II construction, one story above grade plane, used as a place of religious worship or gymnasium, are permitted unlimited area provided they do not have a stage other than a:
507.6
Wood walls and bearing partitions shall not support more than two floors and a roof unless an analysis satisfactory to the building official demonstrates that the resulting wood shrinkage will not have adverse effects on the structure or associated systems.
2304.3.3
If a building has 75 percent of its perimeter fronting on an open space of 40 feet, what is the frontage increase factor?
506.3.3
Equipment platforms shall NOT serve as part of the means of egress from the building, and their area shall NOT be included in determining the:
505.3
The prepared surface of structural members to be sprayed with SFRM must be inspected by the special inspector before the application of the:
1705.15.2
In buildings of Type I or II construction, thermal and acoustical insulation, other than foam plastics, must have a maximum flame spread index of:
603.1
Slopes for permanent fill shall be not steeper than what ratio?
3304.1.1
In separated occupancies, the required separation between Group R and Group F-1 (nonsprinklered) is:
Table 508.4
Is elevator hoistway door protection required at the levels of exit discharge if that level is equipped with an automatic sprinkler system?
3006.2 Exception 2
Flashing and weep holes in anchored veneer must be located not more than what maximum distance above finished ground level above the foundation wall or slab?
1404.4.3
Whenever there is reasonable doubt as to the stability or load-bearing capacity of a completed structure, an engineering assessment shall be required, involving either a structural analysis or an:
1708.1
In structures assigned to Seismic Design Category A or B, detached one- and two-family dwellings three stories or less in height constructed with stud-bearing walls are permitted to have plain concrete footings without:
1905.6.1
According to Table 2609.4, what is the maximum aggregate area of roof panels permitted as a percentage of the floor area when using Class CC1 plastic?
Table 2609.4
A correctional center or jail inhabited by more than five persons who are under restraint or security is classified as which Institutional Group?
308.4
Fire-retardant-treated wood is NOT permitted in roof construction in buildings of Type IA construction exceeding two stories above grade plane where the vertical distance from the upper floor to the roof is less than:
603.1 Exception
Masonry chimneys and foundations must be anchored at each floor, ceiling, or roof line more than 6 feet (1829 mm) above grade with two 3/16-inch by 1-inch (4.8 mm by 25 mm) straps embedded not less than how deep into the chimney?
2113.4
High-hazard Group H occupancy is required when the quantities of hazardous materials exceed those allowed in control areas complying with:
307.1
For a smaller tenant space to pass through a larger adjoining tenant space, the rooms or spaces of the smaller tenant must occupy less than what maximum percentage of the area of the larger tenant space?
1016.2.1 Exception
Where fixed or built-in storage elements are provided in required accessible spaces, at least what percentage, but not less than one of each type, shall be accessible?
1110.12
For Factory and Industrial structures (fabricating, assembly, or processing), what is the required ratio for drinking fountains?
Table 2902.1
An anchor building shall be separated from the covered or open mall building by:
402.4.2.2
Before portions of a structure can be occupied, the required fire protection systems within that portion must be tested and approved in the presence of whom, if required?
901.5
Sleeping units and other habitable rooms of a dwelling unit shall have a net floor area of not less than:
1208.4
Where preservative-treated wood is used in enclosed locations where drying in service cannot readily occur, the wood must be at what maximum moisture content before being covered with insulation, interior finish, or other materials?
2303.1.9.2
If a structure is located in a flood hazard area, what documentation must be submitted to the building official prior to the final inspection?
110.3.12.1
For materials not specifically provided for in this code, the design strengths and permissible stresses must be established by tests as provided for in which section?
1706.2
For buildings located in whole or in part in flood hazard areas, the flood documentation must include the elevation of the proposed lowest floor, referenced to the datum on the community’s Flood Insurance Rate Map (FIRM), for which areas?
1603.1.7
Fasteners for clay or concrete tile shall be of sufficient length to penetrate the deck not less than 3/4 inch or through the thickness of the deck, whichever is:
1507.3.6
The identification signs or stenciling for fire walls in accessible concealed spaces must be located within 15 feet (4572 mm) of the end of each wall and at intervals not exceeding what maximum distance measured horizontally along the wall?
703.5
According to Table 1705.3, what type of special inspection is required to inspect concrete and shotcrete placement for proper application techniques?
Table 1705.3 Item 7
In standard roll-in-type showers designed for assisted bathing, wall-mounted folding seats shall:
1110.2.3.4
Interior floor-wall base that is 6 inches (152 mm) or less in height shall be tested in accordance with Section 804.2 and shall be not less than:
806.7
In heavy timber construction (Type IV-HT), minimum dimensions of columns shall be in accordance with Table 2304.11, and columns must be continuous or aligned vertically from floor to floor in all stories of which type of construction?
2304.11.1.1
What is the assumed maximum presumptive load-bearing value (in pounds per square foot) for public-occupancy temporary structures supported on a pavement, slab on grade, or other collapsible or controlled low-strength substrate soils?
3103.6.2
What is the minimum required fire-resistance rating for an exterior wall of a nonsprinklered Group H occupancy where the fire separation distance is greater than 5 feet and less 10 feet, and the construction type is Other than IA or IVA?
Table 705.5
Sloped glass is defined as glass sloped more than what minimum degree from vertical in applications like skylights and sloped roofs?
2404.2
Fiber-reinforced polymer (FRP) packages and containers delivered to the job site must bear the label of an approved agency showing the manufacturer’s name, product listing, product identification, and what other information?
2613.2
Exterior plastic veneer, other than plastic siding, shall not be attached to any exterior wall to a height greater than what maximum height above grade?
2605.2
According to Table 1507.8.7, what is the maximum weather exposure (in inches) permitted for 24-inch, Grade No. 3 wood shingles of naturally durable wood installed on a 3:12 pitch to less than 4:12 pitch?
1507.8.7
A building that has not been previously occupied or used for its intended purpose must comply with the provisions of this code or the:
102.6.1
In Group B and M occupancies, corridors in ambulatory care facilities shall be provided with interior wall and ceiling finish materials of which classification?
Table 803.13 Note m
Where lightning protection systems are installed, what other protective devices must also be installed in accordance with NFPA 70 and either NFPA 780 or UL 96A, as applicable?
2703.2.1
Where boarding piers are provided at boat launch ramps, at least what percentage, but not less than one, of the boarding piers shall be accessible?
1111.4.9.3
Fiber-mat reinforced cementitious backer units used as an exterior substrate for the application of exterior finish materials must comply with:
1403.13
What is the minimum required fire-resistance rating in hours for interior nonbearing walls and partitions in a Type IA building?
Table 601
In assembly and mercantile occupancies, an accessible family or assisted-use toilet room shall be provided where an aggregate of how many or more male and female water closets is required?
1110.2.1
For clay, sandy clay, silty clay, clayey silt, silt and sandy silt, the lateral sliding resistance shall not exceed what maximum fraction of the dead load?
1806.3.2
According to Table 1607.1, what is the minimum concentrated live load required at any point along primary structural members supporting roofs over manufacturing, storage warehouses, and repair garages?
1607.1
The maximum distance of travel permitted between any point in a Group I-2 occupancy sleeping room (not in a care suite) and an exit access door in that room is:
407.4.2
An attached garage for storage of passenger vehicles must be separated from the covered or open mall building or anchor building by not less than:
402.4.2.3
Habitable spaces, other than a kitchen, shall be not less than what minimum dimension in any plan dimension?
1208.1
Required anchors in masonry walls of hollow units or cavity walls shall be embedded in a:
1604.8.2
In Group I-1, Condition 2 occupancies, the required refuge area shall provide not less than what net square footage for each care recipient?
420.6.1
For individual dwelling units in Groups R-2, R-3, and R-4, fully tempered glass used as single or multiple glazing does not require screening if each pane is 16 square feet (1.5 m2) or less, and the glass thickness is what maximum thickness?
2405.3.3
The design and construction of buildings and structures located in flood hazard areas shall be in accordance with Chapter 5 of ASCE 7 and which other standard?
1612.2
Anchors designed to resist wall out-of-plane forces with design strengths equal to or greater than the force determined in accordance with ASCE/SEI 7 Equation 12.11-1 or 12.14-10 shall be deemed to satisfy which section of ACI 318?
1905.7.1 Exception
Wood shingles shall be laid with a side lap of not less than 1.5 inches between joints in courses, and no two joints in any how many adjacent courses shall be in direct alignment?
1507.8
When tested in accordance with ASTM E331 to demonstrate resistance to wind-driven rain, exterior wall test assemblies must be subjected to a minimum test exposure duration of:
1402.2
Unstabilized adobe masonry walls must receive a weather protective exterior finish in accordance with which section?
2109.2.4.8.1
When the building official grants modifications due to practical difficulties, the modification must not lessen structural requirements, life and fire safety, health, or:
104.2.4
For uninhabitable attics with storage, the attic area is accessed from an opening not less than 20 inches in width by 30 inches in length that is located where the clear height in the attic is not less than:
1607.21.2
According to Table 1807.1.6.3(2) for 8-inch nominal masonry walls (7.63 inches actual thickness), what is the minimum vertical reinforcement required for a 9-foot, 4-inch maximum wall height, 6-foot maximum unbalanced backfill height, and a design lateral soil load of 60 psf/ft?
1807.1.6.3
In Group I-3 guard towers, a hatch or trap door used for means of egress shall be not less than 16 square feet (610 m2) in area and have dimensions of not less than what distance in any direction?
408.3.3
Refrigeration machinery rooms larger than 1,000 square feet (93 m2) require not less than two exits or exit access doorways. Where two are required, one is permitted to be served by a fixed ladder or an:
1006.2.2.2
Food processing establishments and commercial kitchens that are not associated with dining facilities and have an area greater than 2,500 square feet (232 m2) are classified as which occupancy group?
306.2
Required critical circuits must be protected using one of three listed methods, including cables listed in accordance with UL 2196 having a minimum fire-resistance rating of how long?
2702.3
For greenhouses where special scaffolding is used, the minimum roof live load shall be not less than:
1607.14.1
What type of latching hardware is required on corridor doors in Group I-2 occupancies that are not required to have a fire protection rating?
407.3.1
Special inspections for seismic resistance are not required for light-frame construction structures where the design spectral response acceleration at short periods, does not exceed 0.5 and the building height does not exceed:
1705.13 Exception 1
Each tenant space within a mall is required to be separated from other tenant spaces by a:
402.4.2.1
Where through penetrations in a horizontal assembly are protected by a through-penetration firestop system, the system must have an F rating / T rating of not less than:
714.5.1.2
Group H-1 occupancies shall be set back not less than what distance?
415.6.4.1
Where partitions or other obstructions do not separate adjacent water closets, urinals, or bidets, what is the minimum required center-to-center distance between adjacent fixtures?
2903.1.1
The application of a new protective roof coating over an existing protective roof coating is permitted without tear off of existing roof coverings, provided the new coating is applied in accordance with the:
1512.3 Item 4
What two phases of emergency operation must elevators be provided with, in accordance with ASME A17.1/CSA B44?
3003.2
Where exterior wall openings are required to be protected in accordance with Section 705, a light-transmitting plastic skylight shall not be installed within what maximum distance of such exterior wall?
2610.7
What is the required separation and protection for waste and linen collection rooms in Group I-2 occupancies where containers have an aggregate volume of 8.67 cubic feet or greater?
Table 509.1
If a mass timber building element requires a 2-hour fire-resistance rating, what is the minimum protection time required from the noncombustible protection in minutes?
Table 722.7.1(1)
For 2-inch sawn tongue-and-groove decking, each piece must be toenailed at each support with one 16d common nail through the tongue and face-nailed with how many 16d common nails?
2304.9.4.2
Fully tempered glass glazed between intervening floors at a slope of 30 degrees (0.52 rad) or less from vertical does not require screening if the highest point of the glass is what maximum height above the walking surface?
2405.3.3
The minimum net glazed area providing natural light shall be not less than what percentage of the floor area of the room served?
1204.2
What is the maximum unobstructed width permitted for pedestrian walkways?
3104.8
What is the maximum allowable building height in feet for a nonsprinklered (NS) building classified as Group H-1 of Type IB construction?
Table 504.3
When shall the owner or owner’s authorized agent immediately remove walkways, debris, and other obstructions from public property?
3306.8
In a building with occupant evacuation elevators, when is an additional exit stairway not required, even if Section 403.5.2 mandates it?
3008.1.2
What is the tabular allowable area factor (At) for a Group H-2 occupancy of Type VB construction that is nonsprinklered (NS)?
Table 506.2
In Type IV construction, the maximum building height permitted for grain elevators and similar structures is:
426.1.1